| Plan Review Stops For Permit 22070859 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-17 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-17 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-10-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-15 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-14 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2022-10-15 07:49:15 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | BU1635 BN4338 | | | ASFPM CFM US-21-11935 | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.PROVIDE A COPY OF THE MOST RECENT BOUNDARY LINE | | | SURVEY. (2ND REQUEST) | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 (2ND | | | REQUEST) | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | FBC R401.3 SITE DRAINAGE | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-08-22 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-08-22 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2022-08-22 15:29:34 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | BU1635 BN4338 | | | ASFPM CFM US-21-11935 | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.PROVIDE A COPY OF THE MOST RECENT BOUNDARY LINE | | | SURVEY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | FBC R401.3 SITE DRAINAGE | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | | | | 3.PROVIDE THE DESIGN PRESSURES FOR NEW ROOFING PER | | | FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES | | | R301.2.1.1WIND DESIGN REQUIRED. | | | | | | 4.PROVIDE A ROOF SHEATHING FASTENER SCHEDULE PER THE | | | CALCULATED DESIGN PRESSURES. | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-09-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-29 |
Time |
17:55 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-29 |
Time |
17:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-08-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-15 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-15 |
Time |
11:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2023-02-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-28 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-02-28 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2023-02-28 16:24:33 | PHONE, DATA, TV, ALARM JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-10-16 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-10-16 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-09-07 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-08-22 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-29 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-10-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-10-24 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-10-17 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2022-10-24 09:22:26 | RECEIPT MU-2022-047866 - $22.46 PAID | | 2022-10-17 15:32:11 | 10/17/22 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-08-22 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-08-22 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2022-08-22 15:01:56 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-09-08 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-08 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-08 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-09 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-09 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2022-08-09 09:36:17 | 1ST REVIEW FMC | | | PERMIT: 22070859 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A MECHANICAL DRAWING THAT SHOWS ALL THE | | | DOORS ON THE DRAWING. FBC 107.2.1 | | | | | | 2) THE ENERGY CALCULATIONS SUBMITTED ARE LABELED FOR A | | | NEW ADDITION OF 1474 SQ. FT. PLEASE LABEL THIS ON THE | | | MECHANICAL DRAWING. FBC 107.2.1 | | | | | | 3) PROVIDE THE ANCHORAGE DETAILS FOR THE CONDENSING | | | UNITS. FRC M1307.2 | | | | | | 4) SHOW THE CONDENSATE PIPING AND TERMINATION | | | LOCATIONS. FRC M1411.3 | | | | | | 5) THE DESIGNER OF THE MECHANICAL DRAWING MUST SIGN | | | THEIR NAME ON THE DRAWING. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-09-15 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-09-15 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-08-01 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-08-01 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2022-08-09 09:30:21 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. BATH NO. 2 - 2020 FRC P3108.1 - THE WATER CLOSET AND | | | SHOWER ARE NOT VENTED CORRECTLY. THE WASHING MACHINE | | | CANNOT BE INCLUDED IN THE WET VENT FOR BATHROOM GROUP | | | FIXTURES. THE WASHING MACHINE WOULD NEED TO DISCHARGE | | | DOWNSTREAM OF THE LAST BATHROOM GROUP FIXTURE. | | | | | | 2. REMODELED MASTER BATH - 2020 FRC P3108.2.1 - THE TUB | | | AND SHOWER ARE NOT VENTED. ONLY ONE FIXTURE TRAP IS | | | ALLOWED UPSTREAM OF THE VENTED FIXTURE'S CONNECTION. | | | CURRENTLY, THERE ARE TWO TRAPS UPSTREAM. | | | | | | 3. REMODELED KITCHEN - YOU'VE MISLABELED THE KITCHEN | | | SINK AND VEG. SINK AS LAVS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-10-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-15 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-14 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-08-22 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-08-22 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2022-08-22 15:03:27 | PLAN REVIEW ROOFING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: A ROOFING SUB-PERMIT REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR SECONDARY WATER | | | BARRIER PER FBC R905.1.1. | | | UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL | | | CONFORM TO THE APPLICABLE STANDARDS? AND SHALL BE | | | APPLIED AND ATTACHED IN ACCORDANCE WITH SECTION | | | R905.1.1.1, R905.1.1.2 OR R905.1.1.3, AS APPLICABLE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-10-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-15 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-14 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-08-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-09 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-09 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-09-20 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-09-20 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-10 |
|
|
Cont ID |
|
| Sent By |
vbrogila |
Date |
2022-08-10 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-08-10 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2022-08-10 15:29:05 | 8/10/2022 FAILED | | | | | | PLEASE APPLY FOR A LANDSCAPE PERMIT: | | | | | | THE VALUE OF THE CONSTRUCTION ($1,114,869) EXCEEDS 50% | | | OF THE STRUCTURE'S VALUE ($447,622) ACCORDING TO THE | | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | | TO SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE | | | IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | | ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO | | | ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN | | | DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE | | | PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO | | | ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS | | | PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION | | | PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE | | | SITE INTO CONFORMITY. | | | | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | |
|
|