| Plan Review Stops For Permit 22070849 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-08-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-08-15 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-08-15 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-08-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-08-06 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-08-06 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2022-08-06 08:50:05 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | SCOPE NOT CLEAR. APPLICATION IS FOR KITCHEN AND BATHS, | | | PLAN ONLY SHOWS A KITCHEN. EITHER REVISE THE PLAN TO | | | INCLUDE ALL WORK OR SUBMIT A NEW APPLICATION AND THE | | | PERMIT DESCRIPTION WILL BE CHANGED TO KITCHEN ONLY. | | | | | | FBC 107 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-28 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-28 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2022-07-28 07:37:58 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC 107 PLAN SHOULD BE CLEAR AS TO SCOPE AND NATURE | | | OF WORK. PROVIDE AN EXISTING/DEMO PLAN, PROPOSED NEW | | | PLAN. | | | | | | 2. FBC 107 THE PLAN SHOULD INCLUDE THE PRINTED NAME AND | | | SIGNATURE OF THE INDIVIDUAL TAKING RESPONSIBILITY FOR | | | THE DESIGN. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2022-08-16 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-16 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-16 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2022-08-16 13:00:06 | NO ELECTRIC WORK SHOWN, REVIEWED OR APPROVED. MP |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-04 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-04 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-01 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-01 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2022-08-01 13:18:18 | ELECTRIC REVIEW FAILED | | | 1)PLEASE PROVIDE A FLOOR PLAN DETAILING ALL ELECTRICAL | | | WIRING TO BE REMOVED, MODIFIED OR ADDED. INCLUDE | | | ELECTRIC PANEL LOCATION. FBC 107.2 | | | 2) PLEASE PROVIDE ELECTRICAL SERVICE SPECIFICATIONS AND | | | LOAD CALCULATIONS IF ANY ADDITIONAL ELECTRIC LOADS ARE | | | TO BE ADDED. NEC 215.5 | | | 3) PLEASE DETAIL ON PLANS COMPLIANCE WITH ALL | | | APPLICABLE FLORIDA BUILDING AND NATIONAL ELECTRIC | | | CODES. FBC 107.2 | | | 4) PLEASE HAVE DESIGNER OF ALL PLANS SIGN THEM AS | | | REQUIRED. SECTION 107.2.1 WPB | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-08-16 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-16 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-11 |
Time |
06:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-08-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-08-06 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-08-03 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-01 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-07-21 |
Time |
06:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-08-12 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-08-12 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-08-12 |
Time |
10:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-08-05 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-08-05 |
Time |
12:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-07-25 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-25 |
Time |
07:06 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-07-25 |
Time |
07:04 |
Sent To |
|
|
| Notes |
| 2022-07-25 07:09:03 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMENDS 107.2.1 - CLARIFY SCOPE - EITHER | | | PROVIDE AN EXISTING AND PROPOSED FLOOR PLAN TO INDICATE | | | THE CHANGES IN LAYOUT, OR NOTE ON YOUR EXISTING PLAN | | | DETAILING "PLUMBING TO BE REPLACED IN EXISTING | | | LOCATION". IF LOCATION CHANGES ARE MADE, A DETAIL | | | SHOWING THE CHANGES TO THE DRAIN, WASTE AND VENTS IS | | | REQUIRED. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-04 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-04 |
Time |
14:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-01 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-01 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2022-08-01 13:24:23 | SIGNATURE REVIEW FAILED | | | | | | THE DESIGNER OF RECORD WHO PREPARED DRAWINGS SHALL | | | PROVIDE HIS/HER SIGNATURE ON IT- SECTION 107.2.1 WPB, | | | AND FLORIDA STATUTES 471.003(2)(H) & 471.025. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|