Plan Review Details - Permit 22070823
Plan Review Stops For Permit 22070823
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2022-09-06 Cont ID  
Sent By jwitmer Date 2022-09-06 Time 15:12 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-09-06 15:12:29NEW HIGHRISE SHELL BUILDING, SUITE 201 1ST TENANT
 FIT-UP CONSIDERED NEW CONSTRUCTION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-09-22 Cont ID  
Sent By jwitmer Date 2022-09-22 Time 16:12 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-06 Cont ID  
Sent By jwitmer Date 2022-09-06 Time 16:09 Rev Time 0.00
Received By jwitmer Date 2022-09-06 Time 15:15 Sent To  
Notes
2022-09-06 16:09:29WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22070823
 ADD: 360 S ROSEMARY AVE # 201
 CONT: TBD/ TO BE DETERMINED
 TEL:
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
 1ST REVIEW
 DATE: TUES. SEPT. 06TH/ 2022
 ACTION: DENIED
  
 1) THE LIFE SAFETY SHEET INDICATES THIS IS A 21 STORY
 HIGHRISE AN SHOWS AN ELEVATOR AND NO ELEVATOR LOBBY IN
 ACCORDANCE WITH 3006.3. THERE ARE OTHER MEANS OF
 PROTECTION, BUT THE LIFE SAFETY PLAN DOES NOT INDICATE
 COMPLIANCE. THIS PORTION OF THE BUILDING MAY NOT HAVE
 TO MEET THIS REQUIREMENT, IF SO, PLEASE NOTE ON THE
 LIFE SAFETY SHEET THIS ELEVATOR HOISTWAY ONLY TRAVEL
 (HOW MANY STORIES) NOT REQUIRED TO MEET THE HIGHRISE
 ELEVATOR LOBBY REQUIREMENT.
  
  
 2) THE LIFE SAFETY SHEET SHOWS A HIGH/LOW ACCESSIBLE
 DRINKING FOUNTAIN IN CORRIDOR 403. SHEET A0.04
 ACCESSIBILITY STANDARDS SHOWS A SINGLE DRINKING
 FOUNTAIN WITH THE BOTTOM OF THE DRINKING BOWEL AT A
 HEIGHT OF 2 FEET 3 INCHES OR 27 INCHES ABOVE THE FLOOR
 LEVEL. WHERE IT DOES MEET THE LIMITATIONS FOR HEIGHT IT
 DOES NOT MEET THE PROTRUDING LIMITATION OF 4 INCHES.
 SHEET A4.21 DETAIL 8 SHOWS BOTH THE HIGH/ LOW DRINKING
 FOUNTAIN, THEY BOTH PROTRUDE 19 INCHES AWAY FROM THE
 WALL AS WELL AS THE UPPER DRINKING FOUNTAIN THE BOTTOM
 IS 34 INCHES FROM FINISH FLOOR. BOTH DRINKING FOUNTAINS
 NEED TO SHOW COMPLIANCE WITH THE 2020 FBC-ACCESSIBILITY
 CODE SECTION 307.2 AND FIGURE 307.2 LIMITS OF
 PROTRUDING OBJECTS.
  
 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-10-27 Cont ID  
Sent By fgiaquin Date 2022-08-29 Time 22:41 Rev Time 0.00
Received By fgiaquin Date 2022-08-29 Time 20:09 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2023-02-07 Cont ID  
Sent By fgiaquin Date 2023-02-07 Time 10:48 Rev Time 0.00
Received By fgiaquin Date 2023-02-07 Time 10:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-07-29 Cont ID  
Sent By pleduc Date 2022-07-29 Time   Rev Time 0.00
Received By pleduc Date 2022-07-29 Time 12:08 Sent To  
Notes
2022-07-29 12:08:42FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 ENSURE EXIT SIGN IS INSTALLED AT THE CAFE LEADING TO
 THE EXIT STAIR AS PER ELECTRICAL PLAN(IT IS MISSING ON
 THE LIFE SAFETY PLAN.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-10-04 Time   Rev Time 0.00
Received By aoliver Date 2022-09-20 Time 07:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-06 Cont ID  
Sent By jwitmer Date 2022-09-06 Time 16:10 Rev Time 0.00
Received By jwitmer Date 2022-07-28 Time 06:46 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-09-06 Cont ID  
Sent By jwitmer Date 2022-09-06 Time 15:10 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-07-29 Cont ID  
Sent By medwards Date 2022-07-29 Time 13:48 Rev Time 0.00
Received By medwards Date 2022-07-29 Time 13:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-10-04 Cont ID  
Sent By ccole Date 2022-10-04 Time 15:40 Rev Time 0.00
Received By ccole Date 2022-10-04 Time 15:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-08-22 Cont ID  
Sent By ccole Date 2022-08-22 Time 15:19 Rev Time 0.00
Received By ccole Date 2022-08-22 Time 14:21 Sent To  
Notes
2022-08-22 15:22:231ST REVIEW FBC-2020 PLUMBING
 PERMIT-22070823
 8/22/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS A.02 & P0.1: PROVIDE PLUMBING FIXTURE
 CALCULATIONS IN COMPLIANCE WITH TABLE 403.1 FBC P. IT
 APPEARS THE REQUIRED SERVICE SINK IS MISSING FROM THE
 PLANS.
  
 2) P0.1 & P2.1: A MAXIMUM OF ONE FIXTURE DRAIN SHALL
 MAKE CONNECTION TO THE HORIZONTAL WET VENT UPSTREAM OF
 THE DRY VENTED FIXTURE DRAIN CONNECTION- SEC. 912.2.1
 FBC P. PLEASE RELOCATE ONE OF THE TWO WATER CLOSET
 FIXTURE DRAINS SHOWN UPSTREAM OF THE LAVATORY DRAIN.
  
 3) P0.1 & P2.1: THE KITCHEN SINK FIXTURE DRAIN SHALL
 NOT CONNECT TO THE HORIZONTAL WET VENT- SEC. 912.1 FBC
 P.
  
 4) A4.21: PROVIDE THE FOLLOWING DETAILS PER THE FBC
 ACC.
 A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 WATER CLOSETS- SEC. 604.3.
 B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 LAVATORIES- SEC. 606.2.
 C) TURNING SPACE DIAMETERS- SEC. 304.3.
 D) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO
 THE REFLECTIVE SURFACES- SEC. 603.3.
  
 5) A0.02 & 4.21: THE DRINKING FOUNTAINS ARE PROTRUDING
 INTO THE CIRCULATION PATH. THE MAXIMUM ALLOWABLE
 PROTRUSION IS 4-INCHES- SEC. 307.2 FBC ACC.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-09-22 Cont ID  
Sent By jwitmer Date 2022-09-22 Time 16:13 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-09-06 Cont ID  
Sent By jwitmer Date 2022-09-06 Time 16:09 Rev Time 0.00
Received By jwitmer Date 2022-09-06 Time 15:15 Sent To  
Notes
2022-07-29 13:50:15MECHANICAL DIGITAL SIGNATURES APPROVED ME
  