| Plan Review Stops For Permit 22070809 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-08-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-31 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-30 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-08-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-30 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-26 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-08-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-18 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-17 |
Time |
06:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-08-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-12 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-08 |
Time |
09:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-25 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-22 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2022-08-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-31 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-31 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2022-08-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-30 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-30 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2022-08-30 10:18:42 | THERE ARE 2 SHEETS LABELED M7- WALK IN COOLER DETAILS, | | | THE DRAWING HAS THE UNIT #1 LABEL. THEY ARE NOT THE | | | SAME DRAWING AS EACH HAS DIFFERNET INFORMATION ON THE. | | | THE SHEET WITH THE 13 DETAILS IS NOT DIGITALLY SIGNED | | | BY THE DESIGNER. PLEASE RENAME ONE. FBC 107.3.5 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-08-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-18 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-18 |
Time |
08:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-08-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-12 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-12 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-25 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-25 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2022-07-25 07:29:21 | 1) PROVIDE THE MAXIMUM ALLOWABLE QUANTITY OF | | | REFRIGERANT AND PROVIDE THE AMOUNT FOR THIS SYSTEM. FMC | | | 1102.1; 3 | | | | | | 2) IT APPERAS THAT THE REFRIGERATION UNIT IS LESS THAN | | | 4 FEET FROM THE ROOFS EDGE. SHOW THE REQUIRED GUARDS | | | FOR THE SAFETY OF THE SERVICE TECH. FMC 304.11 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-08-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-31 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-31 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2022-08-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-30 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-30 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2022-08-30 10:19:23 | THERE ARE 2 SHEETS LABELED M7- WALK IN COOLER DETAILS, | | | THE DRAWING HAS THE UNIT #1 LABEL. THEY ARE NOT THE | | | SAME DRAWING AS EACH HAS DIFFERNET INFORMATION ON THE. | | | THE SHEET WITH THE 13 DETAILS IS NOT DIGITALLY SIGNED | | | BY THE DESIGNER. PLEASE RENAME ONE. FBC 107.3.5 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-08-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-18 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-18 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2022-08-18 08:46:07 | SHEETS NAMED M1, DRAWING IS NAMED R1: AND SHEET M7, | | | DRAWING IS NAMED UNIT NUMBER 1: THESE DRAWINGS APPEAR | | | TO HAVE A COPY OF THE DESIGNERS DIGITAL SIGNATURE. | | | PLEASE PROVIDE THE ORIGINAL DRAWINGS WITH THE DESIGNERS | | | ORIGINAL DIGITAL SIGNATIRE. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-08-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-12 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-12 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2022-08-12 10:04:37 | THE ENGINEERS DIGITAL SIGNATURES ON SHEETS M AND M6 ARE | | | COPIES OF THE ORIGINAL SIGNATURES. PROVIDE THE ORIGINAL | | | DIGITALLY SIGNED DRAWINGS. FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-07-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-25 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-25 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2022-07-25 07:31:45 | THE PLANS APPEAR TO BE COPIES OF THE ORIGINAL DIGITALLY | | | STAMPED DOCUMENTS. PROVIDE THE ORIGINAL DIGITALLY | | | SIGNED DOCUMENTS. FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|