Plan Review Details - Permit 22070773
Plan Review Stops For Permit 22070773
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status P Date 2022-09-14 Cont ID  
Sent By scwelter Date 2022-09-06 Time 15:10 Rev Time 0.00
Received By swelter Date 2022-09-14 Time 14:51 Sent To  
Notes
2022-09-06 15:10:57TOTAL CONSTRUCTION COSTS OF THIS DEVELOPMENT ARE OVER
 $500,000 IT IS SUBJECT TO THE PUBLIC ART REQUIREMENT AS
 PER CITY ORDINANCE.
 SECTION 78-129: ALL PRIVATE DEVELOPMENT PROJECTS,
 INCLUDING NEW CONSTRUCTION, OR THE RENOVATION OR
 IMPROVEMENT OF AN EXISTING BUILDING, WHERE TOTAL
 CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN
 $500,000 ARE SUBJECT TO THE PUBLIC ART REQUIREMENT.
 OPTION 1: INSTALL ARTWORK ON THE DEVELOPMENT SITE
 VALUED IN AN AMOUNT NOT LESS THAN ONE PERCENT OF THE
 TOTAL CONSTRUCTION COSTS.
 FOR SITE PLAN APPROVAL PUBLIC ART NEEDS TO BE
 IDENTIFIED ON THE SITE PLAN.
 OPTION 2: CONTRIBUTE AN AMOUNT EQUAL TO 75 PERCENT OF
 ONE PERCENT OF THE TOTAL CONSTRUCTION COSTS FOR DEPOSIT
 TO THE PUBLIC ART ACCOUNT.
  
 FOR EITHER OPTION A COMPLETED PUBLIC ART ASSESSMENT
 APPLICATION ALONG WITH EITHER THE ESCROW OF THE 1% OR
 IF CHOSEN OPTION 2 CONTRIBUTION INTO THE PUBLIC ART
 FUND IS REQUIRED AT TIME OF BUILDING PERMIT SUBMITTAL.
  
 CONTACT SYBILLE WELTER, ADMINISTRATOR OF PUBLIC ART &
 CULTURE AT [email protected] WITH FURTHER QUESTIONS.
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2022-08-17 Cont ID  
Sent By rmcphers Date 2022-08-17 Time 13:33 Rev Time 0.00
Received By rmcphers Date 2022-08-17 Time 13:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-12-15 Cont ID  
Sent By rmcphers Date 2022-12-15 Time 10:52 Rev Time 0.00
Received By rmcphers Date 2022-12-15 Time 10:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-12-02 Cont ID  
Sent By rmcphers Date 2022-12-02 Time 15:18 Rev Time 0.00
Received By rmcphers Date 2022-12-02 Time 15:18 Sent To  
Notes
2022-12-02 15:21:12HOTEL ADDITION/REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS A.100, A.300, A.601, A.700, A.800 DO NOT
 SHOW AS DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-10-25 Cont ID  
Sent By rmcphers Date 2022-10-25 Time 12:43 Rev Time 0.00
Received By rmcphers Date 2022-10-25 Time 12:37 Sent To  
Notes
2022-10-25 12:43:28HOTEL ADDITION/REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) REVISED DRAWING S0.1 HAS BEEN UP LOADED TO
 PROJECTDOX ON TOP OF DRAWING S-1.0 PLEASE CORRECT.
  
 2) REVISED STRUCTURAL DRAWINGS SHOW THE ROOFS FOR THE
 GRILL AND BAR CANOPIES AS LOW SLOPE ROOFS - DRAWING
 A300 STILL SHOWS HIP ROOFS.
  
 3) SEPARATE PERMITS WILL BE REQUIRED FOR - SITE WALLS,
 FENCES - PLEASE ACKNOWLEDGE THIS.
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-08-17 Cont ID  
Sent By rmcphers Date 2022-08-17 Time 15:18 Rev Time 0.00
Received By rmcphers Date 2022-08-17 Time 10:07 Sent To  
Notes
2022-08-17 14:27:52HOTEL ADDITION/REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A700 - WALL P4 SHOULD BE SHOWN AS 1HR FIRE
 RATED - AS P4 IS THE DESIGNATION SHOWN ON THE FLOOR
 PLAN FOR THE 1HR FIRE RATED WALLS.
  
 2) WALLS SEPARATING UNITS FROM UNITS AND UNITS FROM
 STORAGE ROOM SHOULD BE SHOWN AS 1 HR FIRE RATED FOR NON
 SPRINKLERED R1 BUILDINGS - FBC 420.2 - - - 708.3
  
 3) WALLS SEPARATING UNIT FROM PUBLIC SERVICE AREA
 (KITCHEN, PUBLIC RESTROOM ETC.) SHOULD BE SHOWN WITH AN
 STC RATING - FBC 1207.2
  
 4) SHOW 2ND FLOOR DECK AREA CEILING SYSTEM TO HAVE AN
 IIC RATING OF 50 OR HIGHER - FBC 1207.3
  
 5) SHOW THE ROOF OVERFLOW SCUPPER DIMENSION FROM THE
 FINISHED ROOF TO THE BOTTOM OF THE SCUPPER - FBC
 1503.4.2.1 OVERFLOW SCUPPERS.
 WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT
 PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR
 PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4
 INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING
  
 6) PLEASE SHOW THE ACCESSIBLE LIFT TO COMPLY WITH ASME
 A18.1 FBC A 410.1
  
 7) PLEASE SHOW THE ACCESSIBLE BAR SEATING AREA - SHOW
 COUNTER HEIGHT AND KNEE AND TOE CLEARANCES FBC A 226.2
  
 8) PLEASE SHOW THE ACCESSIBLE GRILL SEATING AREA - SHOW
 COUNTER HEIGHT AND KNEE AND TOE CLEARANCES FBC A 226.2
  
 9) PLEASE SHOW THE ACCESSIBLE GUEST ROOMS TO COMPLY
 WITH FBC A 224.1.1
  
 10) PLEASE PROVIDE THE SOIL REPORT LISTED ON THE
 DRAWINGS.
  
 11) PLEASE PROVIDE A COMPLETE PRODUCT APPROVAL FOR THE
 ROOFING - REVIEWED AND MARKED APPROVED BY THE DESIGNER
 OF RECORD - FBC WPB 107.3.4
  
 12) ROOFING SYSTEMS PRODUCT APPROVALS MAY BE DEFERRED
 SUBMITTALS BY LISTING ITEMS TO BE DEFERRED ON THE
 CONSTRUCTION DOCUMENTS - FBC WPB 107.3.4.1
  
 13) PLEASE SHOW THE ACCESSIBLE ROUTE FROM THE PARKING
 TO THE ACCESSIBLE ENTRY (SHOW THAT THE ENTRY IS
 ACCESSIBLE) FBC A 206.2.1 - - 206.2.5 RESTAURANTS AND
 CAFETERIAS.
 IN RESTAURANTS AND CAFETERIAS, AN ACCESSIBLE ROUTE
 SHALL BE PROVIDED TO ALL DINING AREAS, INCLUDING RAISED
 OR SUNKEN DINING AREAS, AND OUTDOOR DINING AREAS.
  
 14) FBC 508.4 SEPARATED OCCUPANCIES. - - WALLS
 SEPARATING R1 FROM A2 SHOULD BE 2 HR FIRE RATED - FBC
 508.4.4 SEPARATION.
 INDIVIDUAL OCCUPANCIES SHALL BE SEPARATED FROM ADJACENT
 OCCUPANCIES IN ACCORDANCE WITH TABLE 508.4.
  
 15) FBC 508.3NONSEPARATED OCCUPANCIES. - - THE BUILDING
 WILL NEED TO BE SPRINKLERED - FBC EXISTING BUILDING
 1012.1.1.1 CHANGE OF OCCUPANCY CLASSIFICATION WITHOUT
 SEPARATION.
 WHERE A PORTION OF AN EXISTING BUILDING IS CHANGED TO A
 NEW OCCUPANCY CLASSIFICATION OR WHERE THERE IS A CHANGE
 OF OCCUPANCY WITHIN A SPACE WHERE THERE IS A DIFFERENT
 FIRE PROTECTION SYSTEM THRESHOLD REQUIREMENT IN CHAPTER
 9 OF THE FLORIDA BUILDING CODE, BUILDING, AND THAT
 PORTION IS NOT SEPARATED FROM THE REMAINDER OF THE
 BUILDING WITH FIRE BARRIERS HAVING A FIRE-RESISTANCE
 RATING AS REQUIRED IN THE FLORIDA BUILDING CODE,
 BUILDING FOR THE SEPARATE OCCUPANCY, THE ENTIRE
 BUILDING SHALL COMPLY WITH ALL OF THE REQUIREMENTS OF
 CHAPTER 9 APPLIED THROUGHOUT THE BUILDING FOR THE MOST
 RESTRICTIVE OCCUPANCY CLASSIFICATION IN THE BUILDING
 AND WITH THE REQUIREMENTS OF THIS CHAPTER.
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-11-21 Cont ID  
Sent By fgiaquin Date 2022-11-21 Time 20:29 Rev Time 0.00
Received By fgiaquin Date 2022-11-21 Time 19:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-10-20 Cont ID  
Sent By fgiaquin Date 2022-10-20 Time 21:31 Rev Time 0.00
Received By fgiaquin Date 2022-10-20 Time 20:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-08-19 Cont ID  
Sent By fgiaquin Date 2022-08-19 Time 21:12 Rev Time 0.00
Received By fgiaquin Date 2022-08-18 Time 22:16 Sent To  
Notes
2022-08-19 21:12:21ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH
 PANEL INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE.
 NEC 110.9, 110.10
  
 2. PROVIDE NOTE THAT THE SERVICE EQUIPMENT SHALL BE
 MARKED WITH THE MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT
 AVAILABLE PER NEC 110.24.
  
 3. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF
 SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND
 AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24
  
 4. PERMITTED ADDRESS IS 320 BELVEDERE BUT 310 IS SHOWN
 ON PLANS. PROVIDE CORRECTION. FBC 107.2.1
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-805-6744
  

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2022-11-18 Cont ID  
Sent By rrossano Date 2022-11-18 Time   Rev Time 0.00
Received By rrossano Date 2022-11-18 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2022-10-13 Cont ID  
Sent By rrossano Date 2022-10-13 Time   Rev Time 0.00
Received By rrossano Date 2022-10-13 Time   Sent To  
Notes
2022-10-13 12:19:23UNDER FORMAL ENGINEERING SUBMITTAL REVIEW.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-07-25 Cont ID  
Sent By rrossano Date 2022-07-25 Time   Rev Time  
Received By rrossano Date 2022-07-25 Time   Sent To  
Notes
2022-07-25 16:40:30A FORMAL ENGINEERING SUBMITTAL IS REQUIRED.
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORDINATOR,
 CITY OF WPB ENGINEERING SERVICES DEPARTMENT
 DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE:
 (561) 246-9525
 EMAIL: [email protected]
 HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING-
 STANDARDS-DETAILS
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-10-17 Cont ID  
Sent By   Date 2022-10-17 Time   Rev Time 0.00
Received By bdolan Date 2022-10-11 Time 10:33 Sent To  
Notes
2022-10-17 10:34:06THE FOLLOWING PROVISO COMMENTS WERE SUBMITTED BY LT.
 BRIAN DOLAN, DIVISION OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER THE
 APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY
 ENGINEERED SYSTEM, I.E FIRE SPRINKLER, HOOD/SUPPRESSION
 SYSTEM AND FIRE ALARM, ENSURE THEY COMPLY WITH THE
 REQUIREMENTS OF FS 61G AND SUBMITTED WITH THE MASTER
 PERMIT.
  
 ANY L WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE BY A
 FIRE ALARM CONTRACTOR. A SEPARATE SHOP DRAWING
 COMPLIANT WITH NFPA 72 IS REQUIRED TO BE SUBMITTED,
 REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU
 PRIOR TO ANY INSTALLATION.
  
 ANY WORK ON FIRE SPRINKLER/SUPPRESSION SYSTEMS THAT MAY
 BE REQUIRED, SHALL BE COMPLETED BY A CERTIFIED
 CONTRACTOR AND SHALL COMPLY WITH APPLICABLE NFPA
 STANDARD. SEPARATE SHOP DRAWINGS, ARE REQUIRED TO BE
 SUBMITTED, REVIEWED AND APPROVED BY THE FIRE PREVENTION
 BUREAU PRIOR TO ANY WORK ON THE SYSTEMS.
  
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-09-06 Cont ID  
Sent By   Date 2022-09-06 Time   Rev Time 0.00
Received By bdolan Date 2022-08-08 Time 12:26 Sent To  
Notes
2022-09-06 12:35:56THE FOLLOWING COMMENTS WERE SUBMITTED BY LT. BRIAN
 DOLAN, DIVISION OF FIRE PREVENTION, WEST PALM BEACH
 FIRE RESCUE.
  
 PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER THE
 APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY
 ENGINEERED SYSTEM, I.E FIRE SPRINKLER, HOOD/SUPPRESSION
 SYSTEM AND FIRE ALARM, ENSURE THEY COMPLY WITH THE
 REQUIREMENTS OF FS 61G AND SUBMITTED WITH THE MASTER
 PERMIT.
  
 COMPLETE LIFE SAFETY PLANS FOR THE OCCUPANCY SHALL BE
 PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS,
 EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A
 PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE
 SAFETY FEATURES AND EQUIPMENT.
  
 ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE
 BY A FIRE ALARM CONTRACTOR. A SEPARATE SHOP DRAWING
 COMPLIANT WITH NFPA 72 IS REQUIRED TO BE SUBMITTED,
 REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU
 PRIOR TO ANY INSTALLATION.
  
 ALL WORK ON THE FIRE SPRINKLER/SUPPRESSION SYSTEMS
 REQUIRED TO BE COMPLETED BY A CERTIFIED CONTRACTOR AND
 SHALL COMPLY WITH APPLICABLE NFPA STANDARD. SEPARATE
 SHOP DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED
 AND APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY
 WORK ON THE SYSTEMS.
  
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2022-12-07 Cont ID  
Sent By jesmith Date 2022-12-07 Time 16:12 Rev Time 0.00
Received By jesmith Date 2022-12-07 Time 14:00 Sent To  
Notes
2022-12-07 16:12:10PROVISO: ABOVE GROUND PIPING IN 2 PSI SYSTEM SHALL
 COMPLY WITH FGC TABLE 402.4(5)
  
 PER WPB FBC 107.2.1, 107.3.5.1.5, FBC FG 305.1 AND FBC
 RES G2408.1, MANUFACTURER'S SPECIFICATION/INSTALLATION
 MANUAL(S) FOR ALL GAS EQUIPMENT SHALL BE ON SITE AT THE
 TIME OF INSPECTION.
  
 CITY OF WEST PALM BEACH GAS PIPING AFFIDAVIT OR
 MANOMETER TEST DOCUMENT REQUIRED AT JOBSITE FOR FINAL
 GAS INSPECTION. CALL 561-805-6692 FOR ADDITIONAL
 INFORMATION
  

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-11-02 Cont ID  
Sent By jesmith Date 2022-10-12 Time 12:03 Rev Time 0.00
Received By jesmith Date 2022-10-10 Time 16:15 Sent To  
Notes
2022-10-12 12:00:35CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROL AND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22070773 320 BELVEDERE RD
  
 2ND REVIEW
  
 PROVISO: PER FBC FG 305.1, THE INSTALLATION MANUALS FOR
 ALL GAS APPLIANCES/EQUIPMENT SHALL BE ONSITE AT THE
 TIME OF INSPECTION.
  
 NOTE: A RESPONSE LETTER ADDRESSING EACH ITEM WAS NOT
 PROVIDED WITH THIS SUBMITTAL.
  
  
 GAS COMMENTS: DENIED
  
 NEW COMMENTS:
 1.PD-1.01 CALLS FOR REMOVAL OF EXISTING GAS METER
 REGULATOR. P-2.01 CALLS FOR NEW 1-14 INCH GAS SUPPLY
 FROM CITY AND A NEW METER/REGULATOR TO DELIVER 2 PSI TO
 THE FACILITY. P-3.01 B PLAN AND RISER DIAGRAM SHOWS
 EXISTING GAS FROM CITY WITH EXISTING METER
 METER/REGULATOR SET AT 11 INCHES WATER COLUMN TO
 SERVICE THE FACILITY.
 PER WPB FBC 107.2.1 AND 107.3.5.1.5, PLEASE CLARIFY AND
 RECONCILE DRAWINGS.
  
 2. PER WPB FBC 107.2.1 AND 107.3.5.1.5, PLEASE PROVIDE
 TABLE FOR SIZING OF 2 PSI PIPING. SPECIFY LONGEST
 DEVELOPED LENGTH FOR 2PSI SYSTEM AND FOR EACH SYSTEM
 LESS THAN 2 PSI.
  
 3. SPECIFY REGULATOR(S) AND SHOW LOCATION(S) AS
 REQUIRED FOR SYSTEM(S) LESS THAN 2PSI.
  
 REVIEW 1 COMMENTS:
  
 1. SECOND REQUEST: P-3.01B/GAS RISER DIAGRAM/GAS SIZES
 CHART: PER WPB FBC 107.2.1 AND 107.3.5.1.5, PROVIDE
 DIMENSION OF "ALL" PIPE SEGMENTS BETWEEN THE SERVICE
 REGULATOR AND THE NEW SCHEDULED GAS WATER HEATER TO
 RECONCILE LONGEST DEVELOPED LENGTH(S) OF SYSTEM(S) AND
 TO SHOW COMPLIANCE WITH PIPE SIZING TABLES IN
 ACCORDANCE WITH FBC FG 402.4.
  
 2. COMPLIED
  
 3. SECOND REQUEST: P-3.01B/KEY NOTE 8/GAS SIZES CHART:
 KEY NOTE 8 STATES SERVICE REGULATOR IS SET AT 11 INCHES
 W.C. PRESSURE WHICH IS COVERED BY FBC FG TABLE
 402.4(4). GAS SIZE CHART REFERS TO FBC FG TABLE
 402.4(2) WHICH HAS A PRESSURE DROP OF 0.5 INCHES W.C.
 BUT CALLS OUT A PRESSURE DROP OF 3.0 INCHES OF W.C.
 WHICH WOULD BE COVERED BY FBC FG TABLE 402.4(3). PER
 WPB FBC 107.2.1, PLEASE CLARIFY.
  
 4. SECOND REQUEST: P-3.01B/GAS RISER DIAGRAM/KEY NOTE
 3: THERE APPEARS TO BE AN APPLIANCE REGULATOR AT THE
 WATER HEATER BUT THERE IS NO KEY NOTE APPLIED TO IT.
 KEY NOTE 3 IS APPLIED TO COOKING LINE EQUIPMENT BUT NOT
 THE WATER HEATER. PER WPB FBC 107.2.1, PLEASE CLARIFY.
 ADDITIONALLY, PROVIDE SYSTEM PRESSURE DOWNSTREAM OF THE
 APPLIANCE REGULATOR(S).
 TO BE CLEAR, PLEASE CLEARL INDICATE ALL 2ND STAGE
 REGULATORS FOR ALL EQUIPMENT INCLUDING NEW WATER
 HEATER, KITCHEN LINE AND RELOCATED EXISTING IWHS
  
 5. SECOND REQUEST: PER WPB FBC 107.2.1, PROVIDE A CHART
 LISTING ALL NEW EQUIPMENT AND EXISTING IWHS (TO BE
 NOTED AS SUCH) GAS FIXTURES AND APPLIANCES (INCLUDE
 QUANTITIES) WITH BTU DEMAND REQUIREMENTS FOR EACH.
 PROVIDE TOTAL BTU DEMAND (NEW AND EXISTING) ON THE
 SYSTEM.
  
 6. SECOND REQUESTP-2.01/KEY NOTE 28 AND PD-1.01/ KEY
 NOTE 4: RELOCATED IWHS; PER WPB FBC 107.2.1, PROVIDE
 THE FOLLOWING:
 ***A) NOTE DISTANCES FROM EXHAUST OUTLET TO NEAREST
 VENT OPENINGS INCLUDING WINDOWS AND DOORS.
 ***B) PROVIDE RISER DIAGRAM, INCLUDE VALVES, REGULATORS
 AND SIZING OF PIPE SEGMENTS.
 ***C) NOT REQUIRED
  
 7. SECOND REQUEST: P-2.01/KEY NOTE 29: PER WPB FBC
 107.2.1, PROVIDE MATERIAL SPECIFICATION FOR GAS SERVICE
 UNDERGROUND CONDUIT INCLUDING METHOD FOR PROTECTION
 AGAINST CORROSION; PROVIDE DETAILS FOR CONDUIT
 TERMINATION; INCLUDE VENTING DETAILS
  
 8. SECOND REQUEST: PER WPB FBC 107.2.1, PROVIDE A
 MANUFACTURER'S SPECIFICATION/INSTALLATION MANUAL AND
 VENT DETAIL FOR THE SCHEDULED RHEEM UNIVERSAL G100-200A
 WATER HEATER. DETAIL SHALL PROVIDE THROUGH THE
 WALL/ROOF DETAIL WITH ANCHORING. ADDITIONALLY, SHOW THE
 EXHAUST ROUTING AND TERMINATION ON P-3.01B/PLAN VIEW.
 NEW COMMENT: P4.01 WATER HEATER SCHEDULE NOTES STANDARD
 POWER VENT. P-4.03 SHOWS OPTION FOR POWER VENT AND
 POWER DIRECT VENT. IF THIS IS A POWER DIRECT VENT,
 NOTE, PROVIDE INLET/OUTLET SIZES, MAXIMUM LENGTHS AND
 PROVIDE DETAILS AS NOTED ABOVE.
  
 9. SECOND REQUEST: PER WPB FBC 107.2.1 AND FBC FG
 304.1, PROVIDE CALCULATIONS FOR COMBUSTION AIR FOR THE
 WATER HEATER AND PROVISION TO PROVIDE SAID COMBUSTION
 AIR.
 NEW COMMENT: P4.01 WATER HEATER SCHEDULE NOTES STANDARD
 POWER VENT. P-4.03 SHOWS OPTION FOR POWER VENT AND
 POWER DIRECT VENT. IF THIS IS A POWER DIRECT VENT, THEN
 CALCULATIONS ARE NOT REQUIRED. IF POWER VENT, PROVIDE
 CALCULATIONS AND PROVISION TO PROVIDE SAID COMBUSTION
 AIR
  
 10. SECOND REQUEST: PER WPB FBC 107.2.1 AND FBC FG
 304.1, PROVIDE CALCULATIONS FOR COMBUSTION AIR FOR THE
 COOKING LINE EQUIPMENT AND PROVISION TO PROVIDE SAID
 COMBUSTION AIR.
  
 11. SECOND REQUEST: PER NFPA 96 SECTIONS 10.4 AND 10.5,
 AN EMERGENCY HOOD SHUT OFF VALVE SHALL BE INSTALLED FOR
 THE COOKING LINE EQUIPMENT BELOW THE CEILING. THE
 MANUAL SHUTOFF VALVE SHALL BE UPSTREAM. A UNION SHALL
 BE INSTALLED DOWNSTREAM OF THE MANUAL VALVE. PER WPB
 FBC 107.2.1, PROVIDE A DETAIL.
  
 12. NOT REQUIRED
  
 13. SEE PROVISO
  
 14. COMPLIED
  
  
 END OF COMMENTS.
 PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH ITEM
 WHEN RESUBMITTING.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 PLUMBING INSPECTOR BN2148
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-08-09 Cont ID  
Sent By jesmith Date 2022-08-09 Time 14:29 Rev Time 0.00
Received By jesmith Date 2022-08-04 Time 16:47 Sent To  
Notes
2022-08-09 14:29:22CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROL AND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22070773 320 BELVEDERE RD
  
 1ST REVIEW
  
 GAS COMMENTS: DENIED
  
 1. P-3.01B/GAS RISER DIAGRAM/GAS SIZES CHART: PER WPB
 FBC 107.2.1, PROVIDE DIMENSION OF ?ALL? PIPE SEGMENTS
 BETWEEN THE SERVICE REGULATOR AND THE NEW SCHEDULED GAS
 WATER HEATER TO RECONCILE WITH NOTED LONGEST DEVELOPED
 LENGTH OF 165 FEET AND TO SHOW COMPLIANCE WITH PIPE
 SIZING TABLES IN ACCORDANCE WITH FBC FG 402.4.
  
 2. P-3.01B/GAS RISER DIAGRAM: PER WPB FBC 107.2.1, NOTE
 THE MATERIAL TYPE OF THE GAS PIPING.
  
 3. P-3.01B/KEY NOTE 8/GAS SIZES CHART: KEY NOTE 8
 STATES SERVICE REGULATOR IS SET AT 11 INCHES W.C.
 PRESSURE WHICH IS COVERED BY FBC FG TABLE 402.4(4). GAS
 SIZE CHART REFERS TO FBC FG TABLE 402.4(2) WHICH HAS A
 PRESSURE DROP OF 0.5 INCHES W.C. BUT CALLS OUT A
 PRESSURE DROP OF 3.0 INCHES OF W.C. WHICH WOULD BE
 COVERED BY FBC FG TABLE 402.4(3). PER WPB FBC 107.2.1,
 PLEASE CLARIFY.
  
 4. P-3.01B/GAS RISER DIAGRAM/KEY NOTE 3: THERE APPEARS
 TO BE AN APPLIANCE REGULATOR AT THE WATER HEATER BUT
 THERE IS NO KEY NOTE APPLIED TO IT. KEY NOTE 3 IS
 APPLIED TO COOKING LINE EQUIPMENT BUT NOT THE WATER
 HEATER. PER WPB FBC 107.2.1, PLEASE CLARIFY.
 ADDITIONALLY, PROVIDE SYSTEM PRESSURE DOWNSTREAM OF THE
 APPLIANCE REGULATOR(S).
  
 5. PER WPB FBC 107.2.1, PROVIDE A CHART LISTING ALL NEW
 AND EXISTING (TO BE NOTED AS SUCH) GAS FIXTURES AND
 APPLIANCES (INCLUDE QUANTITIES) WITH BTU DEMAND
 REQUIREMENTS FOR EACH. PROVIDE TOTAL BTU DEMAND (NEW
 AND EXISTING) ON THE SYSTEM.
  
 6. P-2.01/KEY NOTE 28 AND PD-1.01/ KEY NOTE 4:
 RELOCATED IWHS; PER WPB FBC 107.2.1, PROVIDE THE
 FOLLOWING:
 ***A) NOTE DISTANCES FROM EXHAUST OUTLET TO NEAREST
 VENT OPENINGS INCLUDING WINDOWS AND DOORS.
 ***B) PROVIDE RISER DIAGRAM, INCLUDE VALVES, REGULATORS
 AND SIZING OF PIPE SEGMENTS.
 ***C) PROVIDE DETAIL FOR STRUCTURAL SUPPORT SYSTEM.
  
 7. P-2.01/KEY NOTE 29: PER WPB FBC 107.2.1, PROVIDE
 MATERIAL SPECIFICATION FOR GAS SERVICE UNDERGROUND
 CONDUIT INCLUDING METHOD FOR PROTECTION AGAINST
 CORROSION; PROVIDE DETAILS FOR CONDUIT TERMINATION;
 INCLUDE VENTING DETAILS
  
 8. PER WPB FBC 107.2.1, PROVIDE A MANUFACTURER'S
 SPECIFICATION/INSTALLATION MANUAL AND VENT DETAIL FOR
 THE SCHEDULED RHEEM UNIVERSAL G100-200A WATER HEATER.
 DETAIL SHALL PROVIDE THROUGH THE WALL/ROOF DETAIL WITH
 ANCHORING. ADDITIONALLY, SHOW THE EXHAUST ROUTING AND
 TERMINATION ON P-3.01B/PLAN VIEW.
  
 9. PER WPB FBC 107.2.1 AND FBC FG 304.1, PROVIDE
 CALCULATIONS FOR COMBUSTION AIR FOR THE WATER HEATER
 AND PROVISION TO PROVIDE SAID COMBUSTION AIR.
  
 10. PER WPB FBC 107.2.1 AND FBC FG 304.1, PROVIDE
 CALCULATIONS FOR COMBUSTION AIR FOR THE COOKING LINE
 EQUIPMENT AND PROVISION TO PROVIDE SAID COMBUSTION AIR.
  
 11. PER NFPA 96 SECTIONS 10.4 AND 10.5, AN EMERGENCY
 HOOD SHUT OFF VALVE SHALL BE INSTALLED FOR THE COOKING
 LINE EQUIPMENT BELOW THE CEILING. THE MANUAL SHUTOFF
 VALVE SHALL BE UPSTREAM. A UNION SHALL BE INSTALLED
 DOWNSTREAM OF THE MANUAL VALVE. PER WPB FBC 107.2.1,
 PROVIDE A DETAIL.
  
 12. SUBMIT MANUFACTURER'S SPECIFICATION/INSTALLATION
 MANUAL FOR ALL GAS EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND FBC FG 402.2, AND
 301.3. GAS APPLIANCES SHALL BE LISTED AND LABELED.
  
 13. PER FBC FG 305.1, THE INSTALLATION MANUALS FOR ALL
 GAS APPLIANCES/EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION.
  
 14. P-3.01B/KEY NOTE 8 STATES EXISTING SERVICE
 REGULATOR IS SET AT 11 INCHES W.C. PRESSURE. P-2.01/KEY
 NOTE 27 STATES SERVICE REGULATOR IS EXISTING AND THAT
 THE CONTRACTOR SHALL VERIFY THAT IT HAS THE CAPACITY TO
 COMPLY WITH THE NEW GAS DEMAND REQUIREMENTS. TO BE
 CLEAR, PLEASE INDICATE THAT THE 11 INCHES OF WATER
 COLUMN SYSTEM WILL COMPLY WITH THE PROJECT GAS DEMAND
 REQUIREMENTS OR PROVIDE A SERVICE REGULATOR THAT WILL
 COMPLY WITH THE PROJECT GAS DEMAND REQUIREMENTS.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 PLUMBING INSPECTOR BN2148
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2022-11-08 Cont ID  
Sent By fmittner Date 2022-11-08 Time 13:40 Rev Time 0.00
Received By fmittner Date 2022-11-08 Time 13:40 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2022-08-05 Cont ID  
Sent By fmittner Date 2022-08-05 Time 15:26 Rev Time 0.00
Received By fmittner Date 2022-08-05 Time 15:26 Sent To  
Notes
2022-08-05 15:32:48NEED TO SEE FLAT ROOF OPTION FOR BARS

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-12-16 Cont ID  
Sent By medwards Date 2022-12-16 Time 10:49 Rev Time 0.00
Received By medwards Date 2022-12-14 Time 09:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-12-08 Cont ID  
Sent By shill Date 2022-12-08 Time 14:03 Rev Time 0.00
Received By shill Date 2022-11-17 Time 08:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-11-15 Cont ID  
Sent By lmarchan Date 2022-11-15 Time 07:47 Rev Time 0.00
Received By lmarchan Date 2022-10-03 Time 16:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-07 Cont ID  
Sent By aoliver Date 2022-09-07 Time 07:59 Rev Time 0.00
Received By aoliver Date 2022-07-20 Time 08:15 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-12-14 Cont ID  
Sent By aoliver Date 2022-12-14 Time 14:52 Rev Time 0.00
Received By aoliver Date 2022-12-07 Time 08:30 Sent To  
Notes
2022-12-07 08:31:10EMAILED IMPACT FOR REVIEW PER SH -AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-08-17 Cont ID  
Sent By rmcphers Date 2022-08-17 Time 14:58 Rev Time 0.00
Received By rmcphers Date 2022-08-17 Time 14:57 Sent To  
Notes
2022-08-17 14:58:31PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2022-12-16 Cont ID  
Sent By medwards Date 2022-12-16 Time 10:48 Rev Time 0.00
Received By medwards Date 2022-12-16 Time 10:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-11-30 Cont ID  
Sent By medwards Date 2022-11-30 Time 17:19 Rev Time 0.00
Received By medwards Date 2022-11-30 Time 17:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-10-28 Cont ID  
Sent By medwards Date 2022-10-28 Time 15:05 Rev Time 0.00
Received By medwards Date 2022-10-28 Time 15:05 Sent To  
Notes
2022-10-28 15:06:132ND REVIEW FMC
 PERMIT: 22070773
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-0.01: PLEASE PROVIDE THE ZONE AIR EFFECTIVE
 RATE FOR EACH SPACE IN THE OUTDOOR AIR CALCULATIONS.
 FMC TABLE 403.3.1.1.1.2
  
 2) PLEASE EXPLAIN THE KITCHEN AIR BALANCE TABULATION,
 THE DINING ROOM REQUIRES 522 CFM???S OF OUTDOOR AIR IF
 THE ZONE AIR EFFECTIVE RATE IS 1. IT COULD BE MORE IF
 THE ZONE AIR EFFECTIVE RATE IS .8. HOW IS 230 CFM???S
 OF DINING ROOM OUTDOOR AIR BEING TRANSFERRED INTO THE
 KITCHEN? FBC 107.3.5
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-07-28 Cont ID  
Sent By medwards Date 2022-07-28 Time 14:12 Rev Time 0.00
Received By medwards Date 2022-07-28 Time 14:12 Sent To  
Notes
2022-07-28 14:12:251ST REVIEW FMC
 PERMIT: 22070773
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) ADD A NOTE ON THE MECHANICAL DRAWING INDICATING THAT
 THE REFRIGERATION AND KITCHEN HOODS WILL REQUIRE
 SEPARATE PERMITS AND REVIEWS.
  
 2) PROVIDE OUTDOOR AIR CALCULATIONS FOR THE DINING AND
 RETAIL SPACES BASED ON THE OCCUPANT LOAD FROM FMC TABLE
 403.3.1.1. FMC 403.3.1.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2022-12-15 Cont ID  
Sent By rwbrown Date 2022-12-15 Time 06:56 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
2022-12-15 06:57:23PREVIOUSLY PASSED AND STAMPED BY JERRY SMITH.

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-12-07 Cont ID  
Sent By jesmith Date 2022-12-07 Time 16:10 Rev Time 0.00
Received By jesmith Date 2022-12-07 Time 14:00 Sent To  
Notes
2022-12-07 16:10:41ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
  
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  
 PROVISO: PROVIDE CANE APRON FOR DRINKING FOUNTAIN. SEE
 A-601, DRINKING FOUNTAIN DETAIL, NOTE 6 AND FBC ACC
 307.2
  
 PROVISO: EEMAX EMT1.0 AND EEMAX EMT2.5 NOT SERVICING
 PUBLIC LAVATORIES SHALL BE PROVIDED WITH A TEMPERATURE
 ACTUATED MIXING VALVE CONFORMING TO ASSE 1017 PER FBC
 PL 607.1.1, 613.1
 THOSE SERVICING PUBLIC LAVATORIES SHALL BE PROVIDED
 WITH A WATER TEMPERATURE LIMITING DEVICE CONFORMING TO
 ASSE 1070 PER FBC PL FPC 419.5, 607.1.2
  
 PROVISO: THE REVERSE OSMOSIS SYSTEM IN THE KITCHEN
 SHALL BE PROVIDED WITH AN INDIRECT WASTE TO THE FLOOR
 SINK WITH AN AIR GAP. FPC 802.1.1
 THE WATER SUPPLY TO THE REVERSE OSMOSIS SYSTEM SHALL BE
 PROVIDED WITH A BACKFLOW PREVENTER. FPC 608.1
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-11-02 Cont ID  
Sent By jesmith Date 2022-10-10 Time 16:51 Rev Time 0.00
Received By jesmith Date 2022-10-10 Time 11:44 Sent To  
Notes
2022-10-10 16:51:13CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROL AND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22070773 320 BELVEDERE RD
  
  
 2ND REVIEW
  
 NOTE: A RESPONSE LETTER ADDRESSING EACH ITEM WAS NOT
 PROVIDED WITH THIS SUBMITTAL.
  
 PROVISO #1: P-2.01/KEYNOTES 20/21: A 3 INCH SANITARY
 DRAIN IS NOTED FOR THE DRY STORAGE ROOM; CONNECTION TO
 EXISTING SANITARY. A PLAN REVISION WILL BE REQUIRED
 SHOWING THE CONNECTION TO EXISTING. REVISION SHALL BE
 SUBMITTED, APPROVED AND IN PLACE AT TIME OF FINAL
 INSPECTION. DRAINS ARE REMOVED FROM DRY STORAGE PER
 ENGINEER; REVISION STILL REQUIRED TO SHOW NO DRAINS.
 SEE P-3.05.
  
 PROVISO #2: MANUFACTURER'S SPECIFICATION/INSTALLATION
 MANUAL FOR THE FOLLOWING SHALL BE ON SITE PRIOR TO
 FINAL INSPECTION:
 ***A) WATER HEATER(S)
 ***B) BACKFLOW PREVENTER DEVICES
 ***C) THERMOSTATIC MIXING VALVES
 ***D) KITCHEN EQUIPMENT
  
 PROVISO #3: RMS 128/129 AND 130/131 ARE RECONFIGURED TO
 ELIMINATE ONE BATHROOM IN EACH CONFIGURATION; REMAINING
 BATHROOMS ARE RECONFIGURED. ROOM 127 BATHROOM IS
 RECONFIGURED. A PLAN REVISION WILL BE REQUIRED SHOWING
 THE REVISED WATER AND SANITARY. REVISION SHALL BE
 SUBMITTED, APPROVED AND IN PLACE AT TIME OF INSPECTION.
  
 PROVISO #4: P-2.01/KEY NOTE 28 AND PD-1.01/ KEY NOTE 4:
 RELOCATED IWHS; PER WPB FBC 107.2.1, PROVIDE THE
 FOLLOWING:
 ***A) A WATER RISER DIAGRAM TO INCLUDE ALL COMPONENTS
 AND SIZING OF THE HOT AND COLD WATER PIPING INTEGRATED
 WITH EXISTING
 ***B) A DETAIL FOR INSTALLATION OF UNITS TO INCLUDE ALL
 DOMESTIC WATER PIPING AND GAS PIPING.
 ***C) A DETAIL FOR STRUCTURAL SUPPORT SYSTEM.
 A PLAN REVISION WILL BE REQUIRED SHOWING THE ABOVE.
 REVISION SHALL BE SUBMITTED, APPROVED AND IN PLACE AT
 TIME OF INSPECTION.
  
  
 PLUMBING COMMENTS: DENIED
  
 1. THE BACKFLOW PERMIT AND INTERCEPTOR PERMITS ARE
 REQUIRED TO BE SUBMITTED PRIOR TO ISSUANCE OF THE
 PRIMARY PERMIT. YOU CAN SUBMIT AN APPLICATION "TBD" (TO
 BE DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED
 BY EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected] . YOU WILL RECEIVE INSTRUCTIONS
 TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND
 PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS
 REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES
 AND UPLOAD PLANS AT THE SAME TIME. SO THAT APPROPRIATE
 ACTION CAN BE TAKEN BY PLAN REVIEWER, PLEASE ADVISE
 (CONTACT SAMANTHA HILL, CHIEF PLANS EXAMINER,
 [email protected] OR RYAN BROWN, CHIEF PLUMBING INSPECTOR,
 [email protected])WHEN THE APPLICATIONS HAVE BEEN MADE.
 PROVIDE THE PERMIT NUMBERS.
 A SEPARATE PERMIT IS REQUIRED FOR EACH, HOWEVER A
 REVIEW OF THE SYSTEMS UNDER THE MAIN PERMIT IS ALSO
 REQUIRED.
 NOTE: THE CIVIL DRAWINGS SUBMITTED ON 9/29 (C-1.00,
 C-2.00, C-3.00, C-4.00) DO NOT SHOW ANY INDICATION OF A
 GREASE INTERCEPTOR
  
 2. COMPLIED
  
 3. COMPLIED
  
 4. A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS (SEE FBC PL 404.1) BUT IS TYPICALLY ADDRESSED
 ON THE ARCHITECTURAL PLANS. ANY COMMENTS CONCERNING
 THESE REQUIREMENTS MUST BE SATISFACTORILY ADDRESSED
 PRIOR TO A PLUMBING REVIEW APPROVAL.
 PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC ACC
 CHAPTERS 2, 3 AND 6 PROVIDE PLAN AND ELEVATION DETAILS
 FOR NEW TOILET ROOM INDICATING THE FOLLOWING:
 ***B) SECOND REQUEST: A.602/ KEYNOTE 3: PLUMBING
 FIXTURE SCHEDULE CALL FOR FLOOR MOUNTED WATER CLOSET.
 PER FBC ACC 604.8.1.1., PROVIDE A 60 INCH BY 59 INCH
 CLEAR FLOOR SPACE FOR THE WATER CLOSET. RECONCILE WITH
 A.601/WATER CLOSET DETAIL. PROVISO: A-602/KEYNOTE 3;
 CLEAR FLOOR SPACE FOR WATER CLOSET SHALL BE 60 INCHES
 BY 59 INCHES
 ***F) SECOND REQUEST: PER FBC ACC 604.8, TOILET PAPER
 DISPENSERS SHALL COMPLY WITH 309.4 AND SHALL BE 7
 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE
 WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE 15
 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB BARS.
 ***J) COMPLIED
 ***K) COMPLIED
 ***L) SECOND REQUEST: MIRRORS LOCATED ABOVE LAVATORIES
 OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE
 OF THE REFLECTING SURFACE40 INCHES (1015 MM) MAXIMUM
 ABOVE THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED
 ABOVE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH
 THE BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES
 (890 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER
 FBC ACC 603.3.
 ***M) SECOND REQUEST: PROVIDE ELEVATION DETAIL FOR THE
 DRINKING FOUNTAIN SHOWING COMPLIANCE WITH FBC ACC
 602.2, 602.3, 602.4, 602.5 AND 602.7
 NEW COMMENT: THE DRINKING FOUNTAIN SHALL COMPLY WITH
 FBC ACC 307.2. OBJECTS WITH LEADING EDGES MORE THAN 27
 INCHES AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR
 SHALL NOT PROTRUDE MORE THAN 4 INCHES HORIZONTALLY INTO
 THE CIRCULATION PATH.
  
 5.N/A
  
 6.P-2.01/KEYNOTE 2, A.101B/KEYNOTE 15 AND
 A.101C/KEYNOTE 15, D.101/KEYNOTE 27: ALL NOTE REMOVAL
 OF EXISTING PLUMBING FIXTURES AND REPLACE WITH NEW. RMS
 128/129 AND 130/131 ARE RECONFIGURED TO ELIMINATE ONE
 BATHROOM IN EACH CONFIGURATION.
 PER WPB FBC 107.2.1., PROVIDE THE FOLLOWING:
 ***A) SECOND REQUEST: PER FBC ACC 809.4, PLEASE
 IDENTIFY THE ACCESSIBLE GUEST ROOMS AND PROVIDE
 ELEVATION AND PLAN DETAILS FOR ACCESSIBLE BATHING
 ROOM(S) SHOWING COMPLIANCE WITH FBC ACC 603 THROUGH
 610.
 ***B) COMPLIED
 ***C) COMPLIED
 ***D) RMS 128/129 AND 130/131 ARE RECONFIGURED TO
 ELIMINATE ONE BATHROOM IN EACH CONFIGURATION. SEE
 PROVISO: A PLAN REVISION
 WILL BE REQUIRED SHOWING THE REVISED WATER AND
 SANITARY. REVISION SHALL BE SUBMITTED, APPROVED AND IN
 PLACE AT TIME OF INSPECTION.
  
 7. SECOND REQUEST: P-3.01/KITCHEN: ITEMS 1.1, 1.3 AND
 90, EVAPORATOR COIL DRAINS SHALL NOT DISCHARGE TO THE
 GREASY WASTE (FBC PL 1003.2), OR TO SANITARY (WPB CODE
 OF ORDINANCE CHAPTER 90, ARTICLE 3, SECTION 90-12B5).
 PER WPB FBC 107.2.1, DISCHARGE TO STORM OR TO DRYWELL.
 PROVIDE ROUTING AND A DETAIL.
  
 8. P-3.01/KITCHEN: ITEMS 84, 85, 88 AND FLOOR DRAINS
 NOT RECEIVING GREASY WASTE SHALL NOT DISCHARGE TO THE
 GREASY WASTE (FBC PL 1003.2). DISCHARGE TO SANITARY.
 NEW COMMENT: ITEM 65 HAND SINK SHALL NOT DISCHARGE TO
 THE GREASE (FBC PL 1003.2)
 NEW COMMENT: ITEMS 1.1 AND 1.3 EVAPORATOR COILS SHALL
 NOT DISCHARGE TO THE GREASY WASTE (FBC PL 1003.2) OR TO
 SANITARY (WPB CODE OF ORDINANCE CAPTER (), ARTICLE 3,
 SECTION 90-12B5) DISCHARGE TO STORM OR DRYWELL. PROVIDE
 ROUTING AND A DETAIL.
  
 9. P-3.01/KITCHEN: PER FBC PL 708.1.3, PROVIDE AN
 IN-LINE/TWO-WAY CLEANOUT AT THE JUNCTION OF THE
 BUILDING DRAIN AND BUILDING SEWER. SHOW ON P-2.01 AS
 WELL.
  
 10. SECOND REQUEST: P-3.02/BAR: UNDERCOUNTER
 REFRIGERATION COIL AND BACK BAR COOLER SHALL NOT
 DISCHARGE TO THE GREASY WASTE (FBC PL 1003.2), OR TO
 SANITARY (WPB CODE OF ORDINANCE CHAPTER 90, ARTICLE 3,
 SECTION 90-12B5). PER WPB FBC 107.2.1, DISCHARGE TO
 STORM OR TO DRYWELL. PROVIDE ROUTING AND A DETAIL.
  
 11. SECOND REQUEST: P-3.02/BAR: BAR EQUIPMENT SHALL NOT
 DISCHARGE TO THE GREASY WASTE (FBC PL 1003.2).
 DISCHARGE TO SANITARY.
  
 12. SECOND REQUEST: P-3.02/BAR: PER FBC PL 901.2,
 901.2.1 AND 909.1, PROVIDE A VENT(S) FOR THE SYSTEM.
 COMPLY WITH ONE OR MORE OF THE METHODS LAID OUT IN FBC
 PL CHAPTER 9. TO BE CLEAR, THERE SHALL BE AT LEAST ONE
 VENT TO THE OUTSIDE OF THE BUILDING PER FBC PL 904.1
  
 13. SECOND REQUEST: P-3.02/BAR: PER FBC PL 708.1.3,
 PROVIDE AN IN-LINE/TWO-WAY CLEANOUT AT THE JUNCTION OF
 THE BUILDING DRAIN AND BUILDING SEWER. SHOW ON P-2.01
 AS WELL.
  
 14.THIS COMMENT IS NOT APPLICABLE: P3.03/GRILL: BAR
 EQUIPMENT SHALL NOT DISCHARGE TO THE GREASY WASTE (FBC
 PL 1003.2). DISCHARGE TO SANITARY.
 NEW COMMENT: P3.03/GRILL- HAND SINK SHALL NOT DISCHARGE
 TO THE GREASE (FBC PL 1003.2)
  
 15. SECOND REQUEST: P3.03/GRILL: PROVIDE INDIVIDUAL
 VENT TO THE OUTDOORS PER FBC PL 904.1.
 TO BE CLEAR, THERE SHALL BE AT LEAST ONE VENT TO THE
 OUTSIDE OF THE BUILDING PER FBC PL 904.1
  
 16. SECOND REQUEST: P3.03/GRILL: PER FBC PL 708.1.3,
 PROVIDE AN IN-LINE/TWO-WAY CLEANOUT AT THE JUNCTION OF
 THE BUILDING DRAIN AND BUILDING SEWER. SHOW ON P-2.01
 AS WELL.
  
 17. COMPLIED
  
 18. SECOND REQUEST: P-3.04/WOMEN'S RESTROOM: PER FBC PL
 909.1, PROVIDE A VENT(S) FOR WC-2 WATER CLOSET.
  
 19. SECOND REQUEST: P-3.04/MEN'S RESTROOM: PER FBC PL
 909.1, PROVIDE VENT(S) FOR THE UR URINALS.
  
 20. SECOND REQUEST: P-3.04/MEN'S RESTROOM: PER FBC PL
 909.1, PROVIDE A VENT FOR THE 3 INCH FLOOR DRAIN.
  
 21. P-3.04/COMMON RESTROOMS: PER FBC PL 708.1.3,
 PROVIDE AN IN-LINE/TWO-WAY CLEANOUT AT THE JUNCTION OF
 THE BUILDING DRAIN AND BUILDING SEWER. SHOW ON P-2.01
 AS WELL.
  
 22. P-3.05/DRY STORAGE: PER FBC PL 708.1.3, PROVIDE AN
 IN-LINE/TWO-WAY CLEANOUT AT THE JUNCTION OF THE
 BUILDING DRAIN AND BUILDING SEWER. SHOW ON P-2.01 AS
 WELL.
 NEW COMMENT: IF PLUMBING IS NO LONGER REQUIRED FOR DRY
 STORAGE THEN REMOVE THE PLUMBING PLAN P3.05 OR EDIT IT
 TO REFLECT THE FACT.
  
 23. COMPLIED
 24. SECOND REQUEST: PER WPB FBC 107.2.1, PROVIDE PIPING
 MATERIAL SPEC FOR SANITARY SOIL, WASTE AND VENT PIPING.
 NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE PIPING
 MATERIAL SPEC FOR WATER DISTRIBUTION. FBC PL 605.4
 NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE PIPING
 MATERIAL SPEC FOR HOT WATER PIPE INSULATION. FBC EC
 C404.4 (A-E) AND TABLE C403.2.10
  
 25. SECOND REQUEST: ALL COMPONENTS IN THE DOMESTIC
 WATER SYSTEM SHALL BE LEAD FREE IN ACCORDANCE WITH FBC
 PL 605.2 AND 605.2.1. PER WPB FBC 107.2.1, PROVIDE NOTE
 ON PLANS STATING THE SAME.
  
 26. COMPLIED
  
 27. COMPLIED
  
 28. COMPLIED
 NEW COMMENT: WATER HEATER DETAIL HAS BEEN REMOVED;
 PROVIDE A NEW DETAIL SHOWING THE PIPING ARRANGEMENT FOR
 THE SCHEDULED WATER HEATER, EXPANSION TANK, RELIEF
 VALVE, LEONARD MEGATRON PNV-100-LF DIGITAL TEMPERATURE
 CONTROL STATION WITH MIXING VALVE, RECIRCULATING PUMP
 AND ASSOCIATED VALVES/APPURTENANCES. THE CONTROL
 STATION CAN BE INDICATED BY A TAGGED SQUARE; REFERENCE
 LEONARD SUBMITTAL DATA SHEET S-PNV-100-LF-M JUNE, 2021
 WHICH SHALL BE PART OF YOUR SUBMITTAL FOR DETAIL. SHOW
 PIPING IN AND OUT OF THE STATION. INCLUDE TEMPERATURE
 OF HOT WATER OUT OF STATION. SUBMIT LEONARD SUBMITTAL
 DATA SHEET S-PNV-100-LF-M JUNE, 2021.
  
 29. SECOND REQUEST: P-4.01/WATER HEATER SCHEDULE: EEMAX
 EMT1.0 AND EEMAX EMT2.5 ARE STORAGE TANK TYPE WATER
 HEATERS. PER WPB FBC 107.2.1, PROVIDE A DETAIL OF WATER
 HEATER SHOWING HEATER W/STORAGE CAPACITY, PIPING
 INCLUDING CW, HW, VALVES, THERMAL EXPANSION CONTROL
 DEVICE (INCLUDING SIZE), T&P DISCHARGE (INCLUDING
 TERMINATION) AND WATER HEATER PAN AND DRAIN INCLUDING
 TERMINATION IF IN A LOCATION THAT CAN CAUSE WATER
 DAMAGE; COMPLY WITH FBC PL 607.3, 503.1, 504.1, 504.4,
 504.4.1, 504.5, 504.6, 504.7, 504.7.1 AND 504.7.2.
 PROVIDE TEMPERATURE OF HOT WATER AT OUTLET.
  
 30.COMPLIED
  
 31. COMPLIED
  
 32. P-3.05/DRY STORAGE: PER FBC PL 1002.4.1, PLEASE
 PROVIDE A TRAP SEAL PROTECTION DEVICE FOR THE FLOOR
 TROUGH.
 NEW COMMENT: IF PLUMBING IS NO LONGER REQUIRED FOR DRY
 STORAGE THEN REMOVE THE PLUMBING PLAN P3.05 OR EDIT IT
 TO REFLECT THE FACT.
  
 33. P-3.05/DRY STORAGE: PER WPB FBC 107.2.1, PLEASE
 PROVIDE A SCHEDULE AND SPECIFICATION FOR FLOOR DRAINS,
 FLOOR SINKS AND TROUGH DRAINS.
 NEW COMMENT: IF PLUMBING IS NO LONGER REQUIRED FOR DRY
 STORAGE THEN REMOVE THE PLUMBING PLAN P3.05 OR EDIT IT
 TO REFLECT THE FACT.
  
 34.P-3.05 & P-4.02/DETAIL 4: PER WPB FBC 107.2.1, SHOW
 THE INSTALLATION OF THE BACKFLOW PREVENTER(S) AND
 BACKFLOW PREVENTER SPECIFICATION. THE BACKFLOW
 PREVENTER IN P-3.05 IS NOT IN-LINE. CLARIFY AND
 RECONCILE THE DRAWINGS.
 NEW COMMENT: IF PLUMBING IS NO LONGER REQUIRED FOR DRY
 STORAGE THEN REMOVE THE PLUMBING PLAN P3.05 OR EDIT IT
 TO REFLECT THE FACT. IF P-4.02/DETAIL 4 IS NO LONGER
 REQUIRED THEN PLEASE REMOVE IT. OTHERWISE, SPECIFY AND
 PROVIDE A BACKFLOW PREVENTER ON THE OUTLET TO THE
 ICEMAKER. FBC PL 608.1
  
 35.SECOND REQUEST: PER WPB FBC 107.2.1, PROVIDE A SLAB
 REPAIR DETAIL ON THE PLANS. SHOW THE WIDTH OF THE
 REPAIR, THE MINIMUM THICKNESS AND PSI OF THE CONCRETE
 TO BE REPLACED. SHOW SIZE, LENGTH, SPACING (ON CENTER),
 MINIMUM EMBEDMENT AND ANCHORING/ADHESIVE MATERIAL FOR
 DOWELS. THE REPAIR SHALL ALSO INCLUDE TERMITE TREATMENT
 OF THE SOIL AS WELL AS THE REQUIRED VAPOR BARRIER OVER
 WELL COMPACTED SOIL. A COPY OF THE TERMITE CERTIFICATE
 SHALL BE ONSITE FOR FINAL INSPECTION.
  
 36. SECOND REQUEST: PER WPB FBC 107.2.1, TO SHOW
 COMPLIANCE WITH FBC PL 704.1, PROVIDE NOTE STATING
 "HORIZONTAL DRAINAGE PIPING LESS THAN 3 INCH DIAMETER
 SHALL HAVE A MINIMUM SLOPE OF 1/4 INCH PER FOOT. 3 INCH
 TO 6 INCH DIAMETER SHALL HAVE A MINIMUM SLOPE OF 1/8
 INCH PER FOOT."
  
 37. SEE PROVISO #4
  
  
 END OF COMMENTS.
  
 PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH ITEM
 WHEN RESUBMITTING.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 PLUMBING INSPECTOR BN2148
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-08-04 Cont ID  
Sent By jesmith Date 2022-08-04 Time 16:47 Rev Time 0.00
Received By jesmith Date 2022-08-02 Time 11:29 Sent To  
Notes
2022-08-04 16:47:13CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROL AND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22070773 320 BELVEDERE RD
  
  
 1ST REVIEW
  
 PROVISO: P-4.01/PLUMBING FIXTURE SCHEDULE CALLS FOR
 SELECTION OF FIXTURES BY OWNER/ARCHITECT. A PLAN
 REVISION WILL BE REQUIRED SHOWING THE MANUFACTURER,
 MODEL. REVISION SHALL BE SUBMITTED, APPROVED AND IN
 PLACE AT TIME OF FINAL INSPECTION.
  
 PROVISO: P-2.01/KEYNOTES 20/21: A 3 INCH SANITARY DRAIN
 IS NOTED FOR THE DRY STORAGE ROOM; CONNECTION TO
 EXISTING SANITARY. A PLAN REVISION WILL BE REQUIRED
 SHOWING THE CONNECTION TO EXISTING. REVISION SHALL BE
 SUBMITTED, APPROVED AND IN PLACE AT TIME OF FINAL
 INSPECTION.
  
 PROVISO: RMS 128/129 AND 130/131 ARE RECONFIGURED TO
 ELIMINATE ONE BATHROOM IN EACH CONFIGURATION. A PLAN
 REVISION WILL BE REQUIRED SHOWING THE REVISED WATER AND
 SANITARY. REVISION SHALL BE SUBMITTED, APPROVED AND IN
 PLACE AT TIME OF FINAL INSPECTION.
  
 PLUMBING COMMENTS: DENIED
  
 1. THE BACKFLOW PERMIT AND INTERCEPTOR PERMITS ARE
 REQUIRED TO BE SUBMITTED PRIOR TO ISSUANCE OF THE
 PRIMARY PERMIT. YOU CAN SUBMIT AN APPLICATION "TBD" (TO
 BE DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED
 BY EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected] . YOU WILL RECEIVE INSTRUCTIONS
 TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND
 PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS
 REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES
 AND UPLOAD PLANS AT THE SAME TIME.
 A SEPARATE PERMIT IS REQUIRED FOR EACH, HOWEVER A
 REVIEW OF THE SYSTEMS UNDER THE MAIN PERMIT IS ALSO
 REQUIRED.
  
 2. GREASE INTERCEPTOR: P-1.00 CALLS FOR A GB-500
 INTERCEPTOR; P-4.04 CALLS FOR A GB-250 INTERCEPTOR.
 ADDITIONALLY P-1.00 REFERS TO P-4.02 AND SHOULD REFER
 TO P-4.04. PER WPB FBC 107.2.1, PLEASE CLARIFY AND
 RECONCILE THE TWO PLANS.
  
 3. GREASE INTERCEPTOR: PROVIDE AN ENLARGED PIPING
 DIAGRAM SHOWING THE LOCATIONS OF CLEANOUTS, SAMPLING
 POINT AND VENTS AS REQUIRED BY THE MANUFACTURER AND FBC
 PL 1003.9. COORDINATE AND RECONCILE WITH P-1.00
  
 4.PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC ACC
 CHAPTERS 2, 3 AND 6 PROVIDE PLAN AND ELEVATION DETAILS
 FOR NEW TOILET ROOM INDICATING THE FOLLOWING:
 ***B) A.602/ KEYNOTE 3: PLUMBING FIXTURE SCHEDULE CALL
 FOR FLOOR MOUNTED WATER CLOSET. PER FBC ACC 604.8.1.1.,
 PROVIDE A 60 INCH BY 59 INCH CLEAR FLOOR SPACE FOR THE
 WATER CLOSET. RECONCILE WITH A.601/WATER CLOSET DETAIL.
 ***F) PER FBC ACC 604.8, TOILET PAPER DISPENSERS SHALL
 COMPLY WITH 309.4 AND SHALL BE 7 INCHES MINIMUM AND 9
 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE
 DISPENSER SHALL BE 15 INCHES MINIMUM AND 48 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR AND SHALL NOT BE LOCATED
 BEHIND GRAB BARS.
 ***J) A.602; CLEAR FLOOR SPACE FOR URINAL DOES NOT
 MATCH THE ELEVATION. PER WPB FBC 107.2.1, PLEASE
 CLARIFY AND RECONCILE.
 ***K) PER FBC 606.5 EXPOSED PIPES AND SURFACES. WATER
 SUPPLY & DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE
 INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST
 CONTACT.
 ***L) MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS
 SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE
 REFLECTING SURFACE40 INCHES (1015 MM) MAXIMUM ABOVE THE
 FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE
 LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE
 BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES (890
 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC
 ACC 603.3.
 ***M) PROVIDE ELEVATION DETAIL FOR THE DRINKING
 FOUNTAIN SHOWING COMPLIANCE WITH FBC ACC 602.2, 602.3,
 602.4, 602.5 AND 602.7
  
 5.MANUFACTURER'S SPECIFICATION/INSTALLATION MANUAL FOR
 THE FOLLOWING SHALL BE PROVIDED FOR THE FOLLOWING:
 ***A) WATER HEATER(S)
 ***B) BACKFLOW PREVENTER DEVICES
 ***C) THERMOSTATIC MIXING VALVES
 ***D) KITCHEN EQUIPMENT
  
 6.P-2.01/KEYNOTE 2, A.101B/KEYNOTE 15 AND
 A.101C/KEYNOTE 15, D.101/KEYNOTE 27: ALL NOTE REMOVAL
 OF EXISTING PLUMBING FIXTURES AND REPLACE WITH NEW. RMS
 128/129 AND 130/131 ARE RECONFIGURED TO ELIMINATE ONE
 BATHROOM IN EACH CONFIGURATION.
 PER WPB FBC 107.2.1., PROVIDE THE FOLLOWING:
 ***A) PER FBC ACC 809.4, PLEASE IDENTIFY THE ACCESSIBLE
 GUEST ROOMS AND PROVIDE ELEVATION AND PLAN DETAILS FOR
 ACCESSIBLE BATHING ROOM(S) SHOWING COMPLIANCE WITH FBC
 ACC 603 THROUGH 610.
 ***B) REGARDING THE SHOWERS; WILL THEY BE TILE FLOOR
 WITH LINER OR A MANUFACTURED COMPARTMENT OR BASE?
 IF MANUFACTURED, PROVIDE A MANUFACTURER'S
 SPECIFICATION/INSTALLATION MANUAL. SHOW COMPLIANCE WITH
 FBC PL 421.1. ASME A112.19.2/CSA B45.1 OR CSA
 B45.5/IAPMO Z124.
 IN ALL CASES, PER FBC PL 421.4.1, BATHTUB FLOORS,
 SHOWER FLOORS, WALL AREAS ABOVE BUILT-IN TUBS THAT HAVE
 INSTALLED SHOWER HEADS AND WALLS IN SHOWER COMPARTMENTS
 SHALL BE CONSTRUCTED OF SMOOTH, CORROSION-RESISTANT AND
 NONABSORBENT WATERPROOF MATERIALS. WALL MATERIALS SHALL
 EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET (1829 MM)
 ABOVE THE ROOM FLOOR LEVEL, AND NOT LESS THAN 70 INCHES
 (1778 MM) ABOVE THE DRAIN OF THE TUB OR SHOWER. SUCH
 WALLS SHALL FORM A WATER-TIGHT JOINT WITH EACH OTHER
 AND WITH EITHER THE TUB OR SHOWER FLOOR.
 IF TILE FLOOR, PROVIDE A CROSS-SECTION SHOWER
 WALL/FLOOR/DRAIN AND THRESHOLD DETAIL
 DETAIL SHALL INCLUDE ALL COMPONENTS OF FBC PL 421.5.2
 AS FOLLOWS
 LINERS SHALL TURN UP ON ALL SIDES NOT LESS THAN 2
 INCHES ABOVE THE FINISHED THRESHOLD LEVEL
 LINERS SHALL BE RECESSED AND FASTENED TO AN APPROVED
 BACKING
 LINERS SHALL NOT BE NAILED OR PERFORATED AT ANY POINT
 LESS THAN 1 INCH ABOVE THE FINISHED THRESHOLD
 LINERS SHALL BE PITCHED ONE-FOURTH UNIT VERTICAL IN 12
 UNITS HORIZONTAL (2-PERCENT SLOPE) AND SHALL BE SLOPED
 TOWARD THE FIXTURE DRAIN
 LINERS SHALL BE SECURELY FASTENED TO THE WASTE OUTLET
 AT THE SEEPAGE ENTRANCE, MAKING A WATER-TIGHT JOINT
 BETWEEN THE LINER AND THE OUTLET
 FLOORS OR RECEPTORS UNDER SHOWER COMPARTMENTS SHALL BE
 LAID ON, AND SUPPORTED BY, A SMOOTH AND STRUCTURALLY
 SOUND BASE.
 LINER MATERIAL (SPECIFY LINER MATERIAL COMPLYING WITH
 ONE OF THE FOLLOWING FBC PL SECTIONS-421.5.2.1,
 421.5.2.2, 421.5.2.3, 421.5.2.4, 421.5.2.5 OR
 421.5.2.6.) NOTE THAT FBC PL 421.5.2.1 PLASTICIZED
 POLYVINYL CHLORIDE (PVC) SHEETS MEETING THE
 REQUIREMENTS OF ASTM D4551 IS A COMMON LINER USED.
 ***C) PROVIDE A SPECIFICATION FOR THE SHOWER CONTROL
 VALVE SHOWING COMPLIANCE WITH FBC PL 412.3. INDIVIDUAL
 SHOWER AND TUB-SHOWER COMBINATION VALVES SHALL BE
 BALANCED-PRESSURE, THERMOSTATIC OR COMBINATION
 BALANCED-PRESSURE/THERMOSTATIC VALVES THAT CONFORM TO
 THE REQUIREMENTS OF ASSE 1016/ASME A112.1016/CSA
 B125.16 OR ASME A112.18.1/CSA B125.1
 ***D) RMS 128/129 AND 130/131 ARE RECONFIGURED TO
 ELIMINATE ONE BATHROOM IN EACH CONFIGURATION. A PLAN
 REVISION WILL BE REQUIRED SHOWING THE REVISED WATER AND
 SANITARY. REVISION SHALL BE SUBMITTED, APPROVED AND IN
 PLACE AT TIME OF FINAL INSPECTION.
  
  
 7.P-3.01/KITCHEN: ITEMS 1.1, 1.3 AND 90, EVAPORATOR
 COIL DRAINS SHALL NOT DISCHARGE TO THE GREASY WASTE
 (FBC PL 1003.2), OR TO SANITARY (WPB CODE OF ORDINANCE
 CHAPTER 90, ARTICLE 3, SECTION 90-12B5). PER WPB FBC
 107.2.1, DISCHARGE TO STORM OR TO DRYWELL. PROVIDE
 ROUTING AND A DETAIL.
  
 8. P-3.01/KITCHEN: ITEMS 84, 85, 88 AND FLOOR DRAINS
 NOT RECEIVING GREASY WASTE SHALL NOT DISCHARGE TO THE
 GREASY WASTE (FBC PL 1003.2). DISCHARGE TO SANITARY.
  
 9. P-3.01/KITCHEN: PER FBC PL 708.1.3, PROVIDE AN
 IN-LINE/TWO-WAY CLEANOUT AT THE JUNCTION OF THE
 BUILDING DRAIN AND BUILDING SEWER. SHOW ON P-2.01 AS
 WELL.
  
 10. P-3.02/BAR: UNDERCOUNTER REFRIGERATION COIL AND
 BACK BAR COOLER SHALL NOT DISCHARGE TO THE GREASY WASTE
 (FBC PL 1003.2), OR TO SANITARY (WPB CODE OF ORDINANCE
 CHAPTER 90, ARTICLE 3, SECTION 90-12B5). PER WPB FBC
 107.2.1, DISCHARGE TO STORM OR TO DRYWELL. PROVIDE
 ROUTING AND A DETAIL.
  
 11. P-3.02/BAR: BAR EQUIPMENT SHALL NOT DISCHARGE TO
 THE GREASY WASTE (FBC PL 1003.2). DISCHARGE TO
 SANITARY.
  
 12.P-3.02/BAR: PER FBC PL 901.2, 901.2.1 AND 909.1,
 PROVIDE A VENT(S) FOR THE SYSTEM. COMPLY WITH ONE OR
 MORE OF THE METHODS LAID OUT IN FBC PL CHAPTER 9.
  
 13.P-3.02/BAR: PER FBC PL 708.1.3, PROVIDE AN
 IN-LINE/TWO-WAY CLEANOUT AT THE JUNCTION OF THE
 BUILDING DRAIN AND BUILDING SEWER. SHOW ON P-2.01 AS
 WELL.
  
 14. P3.03/GRILL: BAR EQUIPMENT SHALL NOT DISCHARGE TO
 THE GREASY WASTE (FBC PL 1003.2). DISCHARGE TO
 SANITARY.
  
 15. P3.03/GRILL: PROVIDE INDIVIDUAL VENT TO THE
 OUTDOORS PER FBC PL 904.1.
  
 16. P3.03/GRILL: PER FBC PL 708.1.3, PROVIDE AN
 IN-LINE/TWO-WAY CLEANOUT AT THE JUNCTION OF THE
 BUILDING DRAIN AND BUILDING SEWER. SHOW ON P-2.01 AS
 WELL.
  
 17. P3.03/GRILL: P-4.02/DETAIL 6 PROVIDES FOR A TRAP
 PRIMER TO FLOOR DRAIN FROM LAVATORY-TRAP. PLAN SHOWS
 WATER SOURCE TRAP PRIMER FOR WHICH THERE IS NO DETAIL.
 PER WPB FBC 107.2.1, CLARIFY.
  
 18.P-3.04/WOMEN'S RESTROOM: PER FBC PL 909.1, PROVIDE A
 VENT(S) FOR THE WC-2 WATER CLOSETS.
  
 19. P-3.04/MEN'S RESTROOM: PER FBC PL 909.1, PROVIDE
 VENT(S) FOR THE UR URINALS.
  
 20. P-3.04/MEN'S RESTROOM: PER FBC PL 909.1, PROVIDE A
 VENT FOR THE 3 INCH FLOOR DRAIN.
  
 21. P-3.04/COMMON RESTROOMS: PER FBC PL 708.1.3,
 PROVIDE AN IN-LINE/TWO-WAY CLEANOUT AT THE JUNCTION OF
 THE BUILDING DRAIN AND BUILDING SEWER. SHOW ON P-2.01
 AS WELL.
  
 22.P-3.05/DRY STORAGE: PER FBC PL 708.1.3, PROVIDE AN
 IN-LINE/TWO-WAY CLEANOUT AT THE JUNCTION OF THE
 BUILDING DRAIN AND BUILDING SEWER. SHOW ON P-2.01 AS
 WELL.
  
 23. P-3.04/COMMON RESTROOMS: PER FBC PL 607.1, 607.1.1
 AND 607.1.2, SPECIFY AND PROVIDE AT THE LAVATORIES A
 WATER TEMPERATURE LIMITING DEVICES THAT CONFORM TO ASSE
 1070 AND LIMITING THE TEMPERED WATER TO A MAXIMUM OF
 110F.
  
 24.PER WPB FBC 107.2.1, PROVIDE PIPING MATERIAL SPEC
 FOR SANITARY SOIL, WASTE AND VENT PIPING.
  
 25.ALL COMPONENTS IN THE DOMESTIC WATER SYSTEM SHALL BE
 LEAD FREE IN ACCORDANCE WITH FBC PL 605.2 AND 605.2.1.
 PER WPB FBC 107.2.1, PROVIDE NOTE ON PLANS STATING THE
 SAME.
  
 26. PER WPB FBC 107.2.1, PROVIDE ENERGY EFFICIENCY FOR
 EACH SCHEDULED WATER HEATER WATER HEATER; COMPLY WITH
 FBC EC TABLE C404.2
  
 27. P-4.02/DETAIL 3: PER WPB FBC 107.2.1, PROVIDE
 SPECIFICATION AND SIZE FOR EXPANSION TANK ON THE WATER
 HEATER DETAIL.
  
 28. P-4.02/DETAIL 3: SWING CHECK VALVES WHEN INSTALLED
 IN THE VERTICAL POSITION; FLOW SHOWN IS FROM TOP
 DOWNWARD. VALVE IS DEPENDENT ON GRAVITY TO CLOSE AND
 FLOW SHOULD BE FROM THE BOTTOM UPWARD. IF SWING CHECKS
 ARE TO BE USED THEN IN THIS PARTICULAR CASE, INDICATE
 THE PIPING IN A HORIZONTAL POSITION. IF VERTICAL
 INSTALLATION IS REQUIRED WITH FLOW FROM THE TOP
 DOWNWARD, SPECIFY A VALVE SUCH AS A SPRING CHECK
 SPECIFICALLY DESIGNED FOR THAT PURPOSE. ADDITIONALLY,
 PROVIDE A FLOW DIRECTIONAL ARROW AT THE VALVE. WPB FBC
 107.2.1
  
 29. P-4.01/WATER HEATER SCHEDULE: EEMAX EMT1.0 AND
 EEMAX EMT2.5 ARE STORAGE TANK TYPE WATER HEATERS. PER
 WPB FBC 107.2.1, PROVIDE A DETAIL OF WATER HEATER
 SHOWING HEATER W/STORAGE CAPACITY, PIPING INCLUDING CW,
 HW, VALVES, THERMAL EXPANSION CONTROL DEVICE (INCLUDING
 SIZE), T&P DISCHARGE (INCLUDING TERMINATION) AND WATER
 HEATER PAN AND DRAIN INCLUDING TERMINATION IF IN A
 LOCATION THAT CAN CAUSE WATER DAMAGE; COMPLY WITH FBC
 PL 607.3, 503.1, 504.1, 504.4, 504.4.1, 504.5, 504.6,
 504.7, 504.7.1 AND 504.7.2. PROVIDE TEMPERATURE OF HOT
 WATER AT OUTLET.
  
 30.PER WPB FBC 107.2.1, PROVIDE TRAP PRIMER DETAIL FOR
 FLOOR DRAINS WHERE A LAVATORY OR SINK P-TRAP SUPPLY IS
 NOT AVAILABLE. SEE P-3.01A/WATER ISOMETRIC KEYNOTE 4.
  
 31.P-4.01/SHOCK ABSORBERS CHART: PER WPB FBC 107.2.1
 AND FBC PL 604.9, PROVIDE NOTE STATING WATER HAMMER
 ARRESTORS SHALL BE ASSE 1010 COMPLIANT.
  
 32. P-3.05/DRY STORAGE: PER FBC PL 1002.4.1, PLEASE
 PROVIDE A TRAP SEAL PROTECTION DEVICE FOR THE FLOOR
 TROUGH.
  
 33. P-3.05/DRY STORAGE: PER WPB FBC 107.2.1, PLEASE
 PROVIDE A SCHEDULE AND SPECIFICATION FOR FLOOR DRAINS,
 FLOOR SINKS AND TROUGH DRAINS.
  
 34.P-3.05 & P-4.02/DETAIL 4: PER WPB FBC 107.2.1, SHOW
 THE INSTALLATION OF THE BACKFLOW PREVENTER(S) AND
 BACKFLOW PREVENTER SPECIFICATION. THE BACKFLOW
 PREVENTER IN P-3.05 IS NOT IN-LINE. CLARIFY AND
 RECONCILE THE DRAWINGS.
  
 35.PER WPB FBC 107.2.1, PROVIDE A SLAB REPAIR DETAIL ON
 THE PLANS. SHOW THE WIDTH OF THE REPAIR, THE MINIMUM
 THICKNESS AND PSI OF THE CONCRETE TO BE REPLACED. SHOW
 SIZE, LENGTH, SPACING (ON CENTER), MINIMUM EMBEDMENT
 AND ANCHORING/ADHESIVE MATERIAL FOR DOWELS. THE REPAIR
 SHALL ALSO INCLUDE TERMITE TREATMENT OF THE SOIL AS
 WELL AS THE REQUIRED VAPOR BARRIER OVER WELL COMPACTED
 SOIL. A COPY OF THE TERMITE CERTIFICATE SHALL BE ONSITE
 FOR FINAL INSPECTION.
  
 36.PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC PL
 704.1, PROVIDE NOTE STATING "HORIZONTAL DRAINAGE PIPING
 LESS THAN 3 INCH DIAMETER SHALL HAVE A MINIMUM SLOPE OF
 1/4 INCH PER FOOT. 3 INCH TO 6 INCH DIAMETER SHALL HAVE
 A MINIMUM SLOPE OF 1/8 INCH PER FOOT."
  
 37. P-2.01/KEY NOTE 28 AND PD-1.01/ KEY NOTE 4:
 RELOCATED IWHS; PER WPB FBC 107.2.1, PROVIDE THE
 FOLLOWING:
 ***A) A WATER RISER DIAGRAM TO INCLUDE ALL COMPONENTS
 AND SIZING OF THE HOT AND COLD WATER PIPING INTEGRATED
 WITH EXISTING
 ***B) A DETAIL FOR INSTALLATION OF UNITS TO INCLUDE ALL
 DOMESTIC WATER PIPING AND GAS PIPING.
 ***C) A DETAIL FOR STRUCTURAL SUPPORT SYSTEM.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 PLUMBING INSPECTOR BN2148
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status N Date 2022-12-15 Cont ID  
Sent By rmcphers Date 2022-12-15 Time 10:56 Rev Time 0.00
Received By rmcphers Date 2022-12-15 Time 10:56 Sent To  
Notes
2022-12-15 10:56:57ROOFING SYSTEM TO BE DEFERRED

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2022-10-25 Cont ID  
Sent By rmcphers Date 2022-10-25 Time 12:44 Rev Time 0.00
Received By rmcphers Date 2022-10-25 Time 12:44 Sent To  
Notes
2022-10-25 12:44:35ROOFING SYSTEMS TO BE DEFERRED

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-08-17 Cont ID  
Sent By rmcphers Date 2022-08-17 Time 13:35 Rev Time 0.00
Received By rmcphers Date 2022-08-17 Time 13:35 Sent To  
Notes
2022-08-17 13:35:36SEE BUILDING REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2022-12-15 Cont ID  
Sent By rmcphers Date 2022-12-15 Time 10:56 Rev Time 0.00
Received By rmcphers Date 2022-12-15 Time 10:56 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2022-12-07 Cont ID  
Sent By dbattles Date 2022-12-07 Time 16:03 Rev Time 0.00
Received By dbattles Date 2022-12-07 Time 16:02 Sent To  
Notes
2022-12-07 16:08:58SIGNATURE REVIEW FOR PLUMBING/GAS
 PLAN SHEET P-4.03A IS CODE COMPLIANT, HOWEVER IT IS NOT
 DIGITALLY SIGNED. PLEASE UPLOAD A DIGITALLY SIGNED
 SHEET.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-12-02 Cont ID  
Sent By rmcphers Date 2022-12-02 Time 15:21 Rev Time 0.00
Received By rmcphers Date 2022-12-02 Time 15:21 Sent To  
Notes
2022-12-02 15:22:07SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS A.100, A.300, A.601, A.700, A.800 DO NOT
 SHOW AS DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
2022-11-30 17:19:49MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-10-25 Cont ID  
Sent By rmcphers Date 2022-10-25 Time 13:11 Rev Time 0.00
Received By rmcphers Date 2022-10-25 Time 13:11 Sent To  
Notes
2022-10-25 13:15:06SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS E-3.01,E-3.02, E-4.01, E-4.02, E-5.01,
 P-3.01, P-3.01A, P-3.01B, P3.03, P3.04, P3.05 DO NOT
 SHOW AS DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  
2022-10-12 10:22:21DIGITAL SIGNATURES ARE REQUIRED FOR PLUMBING/GAS PLAN
 SHEETS P-3.01, P-3.01A, P-3.01B, P-3.03, P-3.04 AND
 P-3.05. JS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-09-06 Cont ID  
Sent By mpeterso Date 2022-09-06 Time 14:29 Rev Time 0.00
Received By mpeterso Date 2022-09-06 Time 13:57 Sent To  
Notes
2022-09-06 14:33:48SIGNATURE REVIEW FAILED
  
 ALL MEP SHEETS DO NOT SHOW A CERTIFIED DIGTAL SIGNATURE
 AS REQUIRED. ALL OTHER DRAWINGS APPEAR TO SHOW THE
 REQUIRED DIGITAL SIGNATURES. PLEASE CORRECT AS OUTLINED
 BELOW.
  
 FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF
 RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 DIGITALLY SEALED AND SIGNED.
  
 PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS
 FOLLOWING PROJECTDOX INSTRUCTIONS
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
2022-08-17 15:22:13ARCHITECTURAL, STRUCTURAL DRAWINGS OK RMCP
2022-08-02 11:56:54SIGNATURES FOR PLUMBING/GAS DRAWINGS; ONLY P-3.02 HAS A
 VALID DIGITAL SIGNATURE; PLAN SHEETS P0.00, P1.00,
 PD-1.01, P-2.01, P-3.01, P-3.01A, P-3.01B, P-3.03,
 P-3.04, P-3.05, P-4.01, P-4.02, P-4.04, P-4.05 AND
 P-4.06 DO NOT HAVE DIGITAL SIGNATURES. PROVIDE
 DOCUMENTS WITH DESIGNER'S DIGITAL SIGNATURE, AS
 DIGITALLY SUBMITTED DOCUMENTS REQUIRE DIGITAL
 SIGNATURES FROM THE DESIGNERS. FS 471/481. JS
2022-07-28 14:14:21THE MECHANICAL DOCUMENTS WILL NEED TO HAVE THE
 DESIGNER'S DIGITAL SIGNATURE, AS DIGITALLY SUBMITTED
 DOCUMENTS REQUIRE DIGITAL SIGNATURES FROM THE
 DESIGNERS. FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 4 Status P Date 2022-12-16 Cont ID  
Sent By fmittner Date 2022-12-16 Time 09:56 Rev Time 0.00
Received By fmittner Date 2022-12-16 Time 09:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2022-11-18 Cont ID  
Sent By fmittner Date 2022-11-18 Time 11:16 Rev Time 0.00
Received By fmittner Date 2022-11-18 Time 11:16 Sent To  
Notes
2022-11-18 11:16:30STILL NO LANDSCAPE PERMIT

Review Stop Z ZONING
Rev No 2 Status F Date 2022-11-08 Cont ID  
Sent By fmittner Date 2022-11-08 Time 13:40 Rev Time 0.00
Received By fmittner Date 2022-11-08 Time 13:40 Sent To  
Notes
2022-11-08 13:40:51COMMENTS FROM LAST REVIEW NOT ADDRESSED. STILL NEED
 SEPERATE LANDSCAPE PERMIT.

Review Stop Z ZONING
Rev No 1 Status F Date 2022-08-05 Cont ID  
Sent By jroach Date 2022-08-05 Time 15:26 Rev Time 0.00
Received By fmittner Date 2022-08-05 Time 15:26 Sent To  
Notes
2022-08-05 15:29:27REQUIRES SUBMITTAL OF SEPERATE LANDSCAPE PERMIT