| Plan Review Stops For Permit 22070516 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-03-30 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-03-30 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-30 |
Time |
08:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-12-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-12-20 |
Time |
06:13 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-12-19 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2022-12-20 06:14:48 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 1.) OK | | | | | | 2.) FBC B 107.2.1, PROVIDE THE ACCESSIBLE INFORMATION | | | FOR ACCESSIBLE BATHROOMS INCLUDING MEASUREMENTS SUCH AS | | | HEIGHTS & DISTANCES FROM WALLS ON PLAN SHEET A-400 AS | | | PER THE ACCESSIBLE CODE REQUIREMENTS. | | | FBC A 603.3 MIRROR HEIGHTS, FBC A 604 WATER CLOSET | | | REQUIREMENTS, FBC A 604.5 & 609.4 GRAB BAR | | | REQUIREMENTS, FBC A 606 LAVATORY REQUIREMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-09-16 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-09-16 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-09-15 |
Time |
06:41 |
Sent To |
|
|
| Notes |
| 2022-09-16 14:27:01 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 1.) FBC B 1603.1.4, PROVIDE WINDLOAD REQUIREMENTS ON | | | ROOFING PLAN SHEET FOR ALL ZONES. | | | NOTE: A ROOFING SUB-PERMIT IS REQUIRED. | | | | | | 2.) FBC B 107.2.1, PROVIDE THE ACCESSIBLE INFORMATION | | | FOR ACCESSIBLE BATHROOMS ON PLAN SHEET A-102: | | | FBC A 304.3.1 TURNING SPACE, FBC A 603.3 MIRROR | | | HEIGHTS, FBC A 604 WATER CLOSET REQUIREMENTS, FBC A | | | 604.5 & 609.4 GRAB BAR REQUIREMENTS, FBC A 606 LAVATORY | | | REQUIREMENTS. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-10-05 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-10-05 |
Time |
12:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-09-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-09-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-09-15 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-11-22 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-11-22 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2022-09-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-09-16 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-09-16 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-06-28 |
|
|
Cont ID |
|
| Sent By |
avolcy |
Date |
2023-06-28 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-03-07 |
Time |
07:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-02-03 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-02-03 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-11-15 |
Time |
08:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-10-05 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-07 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-09-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-13 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-13 |
Time |
17:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2023-03-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-03-10 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-03-08 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-11-22 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-11-22 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2022-11-22 16:35:50 | 2ND REVIEW PLUMBING- 2020 | | | 22070516 | | | 11/22/22 | | | | | | CODES IN EFFECT. | | | | | | FPC- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES | | | ITEMIZED BELOW THE COMMNT. | | | | | | 1) FAILED. SHEET P-103, JUNIOR SPACE 5: PROVIDE | | | PLUMBING FIXTURE CALCULATIONS IN COMPLIANCE WITH TABLE | | | 403.1 FBC P. PROVIDE A SCHEDULE THAT SHOWS THE REQUIRED | | | AND PROVIDED NUMBER OF FIXTURES FOR THE TENANT SPACE. | | | A) SHEETS A-400, P-101, P-103: SHEET P-101 SHOWS THIS | | | SPACE TO BE A FUTURE RESTAURANT BUT THE PLUMBING | | | FIXTURE CALCULATIONS ON A-400 INDICATE A STORAGE | | | OCCUPANCY. | | | B) A-400, P-101, & P-103 A SERVICE SINK IS REQUIRED FOR | | | THE JUNIOR SPACE 5 PER TABLE 403.1 FBC P. PLEASE | | | CORRECT THE PLANS TO SHOW THE FIXTURE LOCATION AND | | | PLUMBING PIPING. | | | | | | 2) FAILED ITEMS B, E, F, G, H, J, K BELOW. P103 JUNIOR | | | SPACE 5: PROVIDE ENLARGED TOILET ROOM DRAWINGS AND | | | DETAILS SHOWING COMPLIANCE WITH THE FBC 2020 | | | ACCESSIBILITY CODE AS OUTLINED BELOW. | | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | LAVATORIES- SECTION 606.2. (48-INCH CLEAR FLOOR SPACE | | | LENGTH DIMENSION NOT PROVIDED). | | | E) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | | FLOORS- SECTION 604.4. | | | F) HEIGHTS OF THE LAVATORY SINK RIM OR COUNTER SURFACE | | | FROM THE FINISHED FLOOR- SECTION 606.3. | | | G) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO | | | THE REFLECTIVE SURFACES- SECTION 603.3 | | | H) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | | BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4, | | | FIGURES 604. | | | J) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED | | | FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND | | | FIGURE 604.7. | | | K) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION | | | 606.2. | | | | | | NEW COMMENTS BASED ON RESUBMITTED PLANS. | | | 1) A-102 & A-400: SHEET A-102 SHOWS 3- ADA SINGLE-USER | | | TOILET ROOMS AND A-400 SHOWS 2- ADA SINGLE-USER TOILET | | | ROOMS. WHICH IS IT? PLEASE IDENTIFY THE TOILET ROOMS AS | | | MALE, FEMALE, OR UNISEX- SEC. 403.2 FBC P. | | | | | | 2) A-400 DETAIL 5: THE 30X48-INCH CLEAR FLOOR SPACE | | | DIAGRAMS DO NOT APPEAR TO BE LOCATED BEYOND THE ARCS OF | | | THE IN-SWINGING DOORS- SEC. 603.2.3 EXCEPTION 2. | | | | | | 3) P-105 & P-106: TEMPERED WATER SHALL BE DELIVERED | | | FROM THE NEW LAVATORIES IN ACCORDANCE WITH SEC. 419.5 | | | FBC P. THE SPECS FOR THE CHRONOMITE C- MICRO POINT OF | | | USE WATER HEATERS DO NOT INDICATE THE UNITS ARE | | | EQUIPPED WITH INTEGRAL HOT WATER TEMPERATURE LIMITING | | | CONTROLS. PLEASE INDICATE ASSE 1070 APPROVED MIXING | | | VALVES WILL BE INSTALLED- SEC. 607.2.1. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-09-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-09-16 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-09-16 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2022-09-16 12:51:17 | 1ST REVIEW PLUMBING- 2020 | | | 22070516 | | | 9/16/22 | | | | | | CODES IN EFFECT. | | | | | | FPC- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P103, JUNIOR SPACE 5: PROVIDE PLUMBING FIXTURE | | | CALCULATIONS IN COMPLIANCE WITH TABLE 403.1 FBC P. | | | PROVIDE A SCHEDULE THAT SHOWS THE REQUIRED AND PROVIDED | | | NUMBER OF FIXTURES FOR THE TENANT SPACE. | | | | | | 2) P103 JUNIOR SPACE 5: PROVIDE ENLARGED TOILET ROOM | | | DRAWINGS AND DETAILS SHOWING COMPLIANCE WITH THE FBC | | | 2020 ACCESSIBILITY CODE AS OUTLINED BELOW- | | | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | WATER CLOSETS- SECTION 604.3. | | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | | LAVATORIES- SECTION 606.2. | | | C) TURNING SPACE DIAMETERS- SECTION 304.3. | | | D) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE | | | WALLS- SECTION 604.2. | | | E) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED | | | FLOORS- SECTION 604.4. | | | F) HEIGHTS OF THE LAVATORY SINK RIM OR COUNTER SURFACE | | | FROM THE FINISHED FLOOR- SECTION 606.3. | | | G) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO | | | THE REFLECTIVE SURFACES- SECTION 603.3 | | | H) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB | | | BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4, | | | FIGURES 604. | | | I) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS - | | | SECTION 604.6. | | | J) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED | | | FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND | | | FIGURE 604.7. | | | K) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION | | | 606.2. | | | | | | 3) P-106: PLEASE REFER TO TABLE C404.5.1 FBC EC. THE | | | 1/2-INCH HW FIXTURE SUPPLY PIPES TO THE LAVATORIES | | | SHOWN IN THE RISER HAVE EXCEEDED THEIR MAXIMUM 2FT. | | | ALLOWABLE LENGTH DISTANCES FROM THE HOT WATER SOURCE- | | | EWH-2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-03-30 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-03-30 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-30 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2023-03-30 09:26:17 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | SIGNATURE REVIEW DENIED: | | | | | | PLAN SHEET A-003 DOES NOT HAVE A DIGITAL 3RD PARTY | | | VERIFIABLE SIGNATURE BY DESIGN PROFESSIONAL. PLEASE | | | PROVIDE AND RESUBMIT. | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | | VERIFIED) PLAN: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | | | | 2023-03-10 16:48:19 | PLUMBING PLANS PASSED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-12-20 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-12-20 |
Time |
06:27 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-12-19 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2022-11-22 16:47:10 | PLUMBING DIG/SIG PASSED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-09-16 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-09-16 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-09-16 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-06-28 |
|
|
Cont ID |
|
| Sent By |
avolcy |
Date |
2023-06-28 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-06-28 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-02-03 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2023-02-03 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2023-02-03 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2023-02-03 09:21:48 | REVIEW STATUS: FAILED | | | ________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. MULTIPLE AREAS ON THE PLANS, ESPECIALLY ALONG THE | | | EAST AND NORTHEAST PORTIONS OF THE BUILDING, DO NOT | | | MATCH THE LATEST SITE/LANDSCAPE PLANS FOR THE SHOPS AT | | | THE PRESS DEVELOPMENT OF SIGNIFICANT IMPACT (DSI). | | | ENSURE THAT ALL PLANS ARE CONSISTENT, OR THAT THE | | | NECESSARY AMENDMENTS TO THE DSI ARE SUBMITTED. | | | ________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ??? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | TTY: 800.955.8771 | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|