| Plan Review Stops For Permit 22070505 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
5 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-22 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-22 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
4 |
Status |
F |
Date |
2023-01-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-10 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-10 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2023-01-10 09:13:26 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
F |
Date |
2022-11-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-21 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-21 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2022-11-21 10:40:19 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2022-09-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-30 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-30 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-02 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-02 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2022-09-02 14:27:20 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-22 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-22 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2023-06-22 08:37:05 | STORAGE ROOM ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE SITE PLAN NEEDS TO SHOW THE LOT DRAINAGE AWAY | | | FROM THE BUILDING AND AWAY FROM THE ADJACENT PROPERTY | | | OR PROVIDE A STORM WATER DRAINAGE PLAN. - PLEASE | | | PROVIDE A SURVEY/SITE PLAN SHOWING THE FOLLOWING | | | INFORMATION - FBC WPB 107.2.5 SITE PLAN. THE | | | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION | | | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING | | | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND | | | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT | | | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED | | | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE | | | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND | | | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN | | | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY | | | LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY | | | PROPOSED WATER RETAINING SWALES) | | | | | | 2) PLEASE SHOW THE ROOF DRAIN SCUPPER LEVEL WITH THE | | | ROOF SURFACE - FBC 1503.4.2 SCUPPERS. WHERE REQUIRED | | | FOR ROOF DRAINAGE, A SCUPPER SHALL BE PLACED LEVEL WITH | | | THE ROOF SURFACE IN A WALL OR PARAPET. (DRAWING A-301 | | | DETAIL 2 - SHOWS THE ROOF SCUPPER TOO HIGH ABOVE THE | | | ROOF) | | | | | | 3) DRAWING G-000 - UNDER "PROJECT DESCRIPTION" | | | RESIDENTIAL CODE SHOULD NOT BE MENTIONED. | | | | | | 4) IN THE PRODUCT APPROVAL PROVIDED FOR THE ROOFING | | | FLAT DECK - PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED | | | IN THE ROOFING PRODUCT APPROVAL - ROOFING SYSTEM TO BE | | | USED ON THE PROVIDED PRODUCT APPROVAL MAY REQUIRE | | | ADDITIONAL SIGNED AND SEALED ATTACHMENT DETAILS FROM AN | | | ARCHITECT OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH | | | REQUIRE A HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE | | | PRODUCT APPROVAL - SEE GENERAL LIMITATION NOTE NUMBER 7 | | | ON THE PRODUCT APPROVAL | | | | | | 5) SOME DRAWINGS STILL SHOW A NEW EXTERIOR DOOR - | | | A-102, E-101, M101 - ALL DRAWINGS SHOULD MATCH. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-01-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-10 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-10 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2023-01-10 09:06:47 | STORAGE ROOM ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE SITE PLAN NEEDS TO SHOW THE LOT DRAINAGE AWAY | | | FROM THE BUILDING AND AWAY FROM THE ADJACENT PROPERTY | | | OR PROVIDE A STORM WATER DRAINAGE PLAN. - PLEASE | | | PROVIDE A SURVEY/SITE PLAN SHOWING THE FOLLOWING | | | INFORMATION - FBC WPB 107.2.5 SITE PLAN. THE | | | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION | | | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING | | | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND | | | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT | | | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED | | | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE | | | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND | | | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN | | | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY | | | LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY | | | PROPOSED WATER RETAINING SWALES) | | | | | | 2) PLEASE SHOW THE EMERGENCY ROOF DRAIN SCUPPER | | | DISTANCE FROM THE ROOF SURFACE - FBC 1503.4.2.1 | | | OVERFLOW SCUPPERS. WHEN OTHER MEANS OF DRAINAGE OF | | | OVERFLOW WATER IS NOT PROVIDED, OVERFLOW SCUPPERS SHALL | | | BE PLACED IN WALLS OR PARAPETS NOT LESS THAN 2 INCHES | | | (51 MM) NOR MORE THAN 4 INCHES (102 MM) ABOVE THE | | | FINISHED ROOF COVERING | | | | | | 3) PLEASE SHOW THE ROOF DRAIN SCUPPER LEVEL WITH THE | | | ROOF SURFACE - FBC 1503.4.2 SCUPPERS. WHERE REQUIRED | | | FOR ROOF DRAINAGE, A SCUPPER SHALL BE PLACED LEVEL WITH | | | THE ROOF SURFACE IN A WALL OR PARAPET. (DRAWING A-301 | | | DETAIL 2 - SHOWS THE ROOF SCUPPER TOO HIGH ABOVE THE | | | ROOF) | | | | | | 4) DRAWING G-000 - UNDER "PROJECT DESCRIPTION" | | | RESIDENTIAL CODE SHOULD NOT BE MENTIONED. | | | | | | 5) PLEASE PROVIDE THE FRONT PAGE OF THE ROOFING SYSTEM | | | FLORIDA STATE PRODUCT APPROVAL (FL31780) | | | | | | 6) SOME DRAWINGS STILL SHOW A NEW EXTERIOR DOOR - | | | A-301, E-101 - ALL DRAWINGS SHOULD MATCH. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-11-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-21 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-21 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2022-11-21 10:30:37 | STORAGE ROOM ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE SITE PLAN NEEDS TO SHOW THE SET BACKS FROM THE | | | PROPERTY LINES - PLEASE PROVIDE A SURVEY/SITE PLAN | | | SHOWING THE FOLLOWING INFORMATION - FBC WPB 107.2.5 | | | SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED WITH | | | THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY A | | | SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF NEW | | | CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED ON A BOUNDARY LINE SURVEY. (PLEASE PROVIDE CUT | | | SECTIONS FOR ANY PROPOSED WATER RETAINING SWALES) | | | | | | 2) THE SITE PLAN NEEDS TO SHOW THE LOT DRAINAGE AWAY | | | FROM THE BUILDING AND AWAY FROM THE ADJACENT PROPERTY | | | OR PROVIDE A STORM WATER DRAINAGE PLAN. - PLEASE | | | PROVIDE A SURVEY/SITE PLAN SHOWING THE FOLLOWING | | | INFORMATION - FBC WPB 107.2.5 SITE PLAN. THE | | | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION | | | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING | | | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND | | | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT | | | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED | | | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE | | | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND | | | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN | | | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY | | | LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY | | | PROPOSED WATER RETAINING SWALES) | | | | | | 3) PLEASE SHOW THE ROOF DRAINAGE FOR THE HIGHER ROOF - | | | FBC 1503.4 | | | | | | 4) PLEASE SHOW THE ROOF OVERFLOW DRAINAGE FOR THE | | | HIGHER ROOF PER FBC 1503.4.2.1 | | | | | | 5) DRAWING A-301 DETAIL 2 - SHOWS THE ROOF SCUPPER TOO | | | HIGH ABOVE THE ROOF - FBC 1503.4 | | | | | | 6) THE PROVIDED SURVEY SHOWS THE EXISTING BUILDING | | | SETBACK FROM THE PROPERTY LINES AT 4' 7" - WHICH THE | | | NEW BUILDING (NON SPRINKLERED) WILL EVEN BE CLOSER TO | | | THE PROPERTY LINE - THE NEW DOOR OPENING IS NOT ALLOWED | | | IN AN EXTERIOR FIRE RATED WALL PER FBC TABLE 705.8 | | | | | | 7) DRAWING G-000 - UNDER "PROJECT DESCRIPTION" SAYS - | | | "CONFORMS TO THE FLORIDA RESIDENTIAL CODE" - SHOULD NOT | | | BE THE RESIDENTIAL CODE. | | | | | | 8) PLEASE PROVIDE A SOIL REPORT (GEOTECHNICAL REPORT) | | | FBC 1803 | | | | | | 9) THE STRUCTURAL DRAWINGS S001, S-100, S-101 NEED TO | | | BE DIGITALLY/ELECTRONICALLY SIGNED - SIGNED AND SEALED | | | DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | | | | 10) PLEASE PROVIDE THE FRONT PAGE OF THE ROOFING SYSTEM | | | FLORIDA STATE PRODUCT APPROVAL. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-09-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-30 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-30 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2022-09-30 08:36:06 | STORAGE ROOM ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE A SURVEY/SITE PLAN SHOWING THE | | | FOLLOWING INFORMATION - FBC WPB 107.2.5 SITE PLAN. THE | | | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION | | | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING | | | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND | | | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT | | | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED | | | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE | | | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND | | | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN | | | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY | | | LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY | | | PROPOSED WATER RETAINING SWALES) | | | | | | 2) PLEASE PROVIDE A SURVEY. | | | | | | 3) PLEASE SHOW THE ROOF DRAINAGE - FBC 1503.4 | | | | | | 4) PLEASE SHOW THE ROOF OVERFLOW DRAINAGE PER FBC | | | 1503.4.2.1 | | | | | | 5) PLEASE SHOW THE BUILDING CONSTRUCTION TYPE PER FBC | | | CHAPTER 6 | | | | | | 6) PLEASE SHOW THE BUILDING OCCUPANCY CLASSIFICATION | | | PER FBC CHAPTER 3 | | | | | | 7) DRAWING G-000 - UNDER "PROJECT DESCRIPTION" SAYS - | | | "CONFORMS TO THE FLORIDA RESIDENTIAL CODE" - SHOULD NOT | | | BE THE RESIDENTIAL CODE. | | | | | | 8) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE EXTERIOR DOORS AND ROOFING | | | SYSTEMS - ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND | | | MARKED APPROVED BY THE BUILDING DESIGNER OF RECORD FBC | | | WPB 107.3.4 | | | | | | 9) PLEASE PROVIDE A SOIL REPORT (GEOTECHNICAL REPORT) | | | FBC 1803 | | | | | | 10) THE STRUCTURAL DRAWINGS NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED - SIGNED AND SEALED | | | DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-02 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-02 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2022-09-02 14:26:47 | STORAGE ROOM ADDITION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) NEED A COMPLETE SET OF DRAWINGS FOR THE ADDITION - | | | FBC WPB107.2.1 ---- FBC WPB 107.3.5 MINIMUM PLAN REVIEW | | | CRITERIA FOR BUILDINGS. THE EXAMINATION OF THE | | | DOCUMENTS BY | | | THE BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING | | | MINIMUM CRITERIA AND DOCUMENTS: A FLOOR PLAN; | | | SITE PLAN; FOUNDATION PLAN; FLOOR/ROOF FRAMING PLAN OR | | | TRUSS LAYOUT; ALL FENESTRATION PENETRATIONS; | | | FLASHING; AND ROUGH OPENING DIMENSIONS; AND ALL | | | EXTERIOR ELEVATIONS: | | | | | | 2) ALL SIGNED AND SEALED DRAWINGS NEED TO BE | | | ELECTRONICALLY/DIGITALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-06-26 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-06-26 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-28 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-28 |
Time |
10:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-10-11 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-11 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-11 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-08-25 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-25 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-25 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2022-08-25 09:16:10 | ELECTRIC REVIEW FAILED | | | 1) PLEASE PROVIDE WORK SCOPE AND PLANS AS APPLICABLE. | | | FBC 107.2 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-06-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-06-22 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2023-01-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-01-06 08:42:32 | FIRE PROVISO COMMENTS: | | | | | | PROVIDE APPROPRIATE PORTABLE FIRE EXTINGUISHERS IN CODE | | | COMPLIANT LOCATIONS SUITABLE FOR THE HAZARD | | | CLASSIFICATION AND WITHIN 75 FT. TRAVEL DISTANCE. | | | | | | ANY WORK INVOLVING ANY LIFE SAFETY SYSTEM (FIRE | | | SPRINKLER AND/OR FIRE ALARM) SHALL BE CONDUCTED UNDER | | | SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2022-11-14 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-11-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-11-14 08:40:26 | FIRE PROVISO COMMENTS: | | | | | | PROVIDE APPROPRIATE PORTABLE FIRE EXTINGUISHERS IN CODE | | | LOCATIONS SUITABLE FOR THE HAZARD CLASSIFICATION AND | | | WITHIN 75 FT. TRAVEL DISTANCE. | | | | | | ANY WORK INVOLVING ANY LIFE SAFETY SYSTEM (FIRE | | | SPRINKLER AND/OR FIRE ALARM) SHALL BE CONDUCTED UNDER | | | SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-09-23 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-09-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-09-23 11:07:58 | FIRE PROVISO COMMENTS: | | | | | | PROVIDE APPROPRIATE PORTABLE FIRE EXTINGUISHERS IN CODE | | | COMPLIANT LOCATIONS SUITABLE FOR THE HAZARD | | | CLASSIFICATION AND WITHIN 75 FT. TRAVEL DISTANCE. | | | | | | ANY WORK INVOLVING ANY LIFE SAFETY SYSTEM (FIRE | | | SPRINKLER AND/OR FIRE ALARM) SHALL BE CONDUCTED UNDER | | | SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-07-21 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-07-21 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-07-21 13:32:30 | PROVIDE A DETAILED FLOOR PLAN TO ALLOW FOR ADEQUATE | | | PLAN REVIEW TO INCLUDE WALL CONSTRUCTION AND ANY CODE | | | REQUIREMENTS THAT COULD IMPACT EGRESS. NFPA 1, 1.14 | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-06-27 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-06-27 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-06-20 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-01-26 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-01-26 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-12-06 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2022-12-06 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2022-11-13 |
Time |
19:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-10-11 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-11 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-09-22 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-02 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-20 |
Time |
06:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-02 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-02 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2022-09-02 14:28:02 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2023-01-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-10 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-10 |
Time |
16:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2022-11-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-18 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-18 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2022-11-18 10:29:08 | THE UPDATED DRAWING DOES NOT SHOW THE DUCT SIZES FOR | | | THE NEW STORAGE ROOM. THE OUTDOOR AIR CALCULATIONS | | | SHOULD HAVE BEEN SUBMITTED AS PART OF THE EQUIPMENT | | | SIZING. PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS FOR | | | THE NEW STORAGE ROOM AND SHOW THAT THE EXISTING RTU CAN | | | PROVIDE THIS OUTDOOR AIR. FMC 403.3.1.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-09-26 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-26 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-26 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2022-09-26 13:28:27 | 1ST REVIEW FMC | | | PERMIT: 22070505 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE THE ENERGY CALCULATIONS FOR THIS NEW | | | ADDITION. FEC C402 | | | | | | 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | OF THE EXISTING MECHANICAL SYSTEM SHOWING IT IS SIZED | | | TO ACCOMMODATE THE NEW ADDITION LOADS. FEC C403.2.1 | | | | | | 3) PROVIDE DUCT SIZES ON THE DRAWING. FBC 107.3.5 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-28 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-28 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2022-07-28 14:33:32 | PROVIDE A COMPLETE SCOPE OF WORK FOR THIS PROJECT. THE | | | DRAWINGS SHOULD INCLUDE MORE INFORMATION SUCH AS THE | | | OVER ALL BUILDING AND WHAT IS GOING ON. PROVIDE ENERGY | | | CALCULATIONS AND MECHANICAL EQUIPMENT SIZING FOR THE | | | EXISTING TO SHOW THE EXISTING SYSTEM IS SIZED TO | | | CONDITION THIS SPACE. NOT ENOUGH INFORMATION INCLUDED | | | TO DO A REVIEW. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-22 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-22 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2023-01-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-01-09 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-01-09 |
Time |
06:55 |
Sent To |
|
|
| Notes |
| 2023-01-09 08:00:11 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT- 22070505 | | | 1/9/23 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. THE REQUESTED RESPONSE TO | | | THE 1ST REVIEW COMMENT #1 COPIED BELOW WAS NOT | | | PROVIDED. PRIMARY AND SECONDARY DRAINS ARE NOW PROVIDED | | | ON SHEET A-103 HOWEVER THE REQUESTED RAINFALL RATE, GPM | | | FLOW CALCULATIONS, AND DOWNSPOUT SIZES WERE NOT | | | PROVIDED. | | | | | | 1) SHEET A-103: PROVIDE PRIMARY AND SECONDARY ROOF | | | DRAINAGE PLANS FOR THE NEW ADDITION- SEC. 1101.2, | | | 1101.7, 1105.1 & 1106.1 FBC P. PLEASE SHOW ROOF | | | DRAINAGE CONVEYED TO AN APPROVED PLACE OF DISPOSAL AND | | | INCLUDE THE RAINFALL RATE, GPM FLOW CALCULATIONS AND | | | SYSTEM DETAILS- LOCATIONS AND SIZES OF ROOF | | | DRAINS/SCUPPERS HORIZONTAL DRAIN PIPES, VERTICAL | | | LEADERS, GUTTERS ETC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-11-15 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-11-15 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-11-15 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-09-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-09-27 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-09-27 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2022-09-27 12:37:16 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 22070505 | | | 9/27/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A-103: PROVIDE PRIMARY AND SECONDARY ROOF | | | DRAINAGE PLANS FOR THE NEW ADDITION- SEC. 1101.2, | | | 1101.7, 1105.1 & 1106.1 FBC P. PLEASE SHOW ROOF | | | DRAINAGE CONVEYED TO AN APPROVED PLACE OF DISPOSAL AND | | | INCLUDE THE RAINFALL RATE, GPM FLOW CALCULATIONS AND | | | SYSTEM DETAILS- LOCATIONS AND SIZES OF ROOF | | | DRAINS/SCUPPERS HORIZONTAL DRAIN PIPES, VERTICAL | | | LEADERS, GUTTERS ETC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
F |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-22 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-22 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2023-06-22 09:00:42 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING M101 DOES NOT SHOW AS DIGITALLY SIGNED IN | | | ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2023-01-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-10 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-10 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2023-01-10 16:00:52 | SEE PREVIOUS REVIEW COMMENTS BELOW: | | | | | | SIGNATURE REVIEW FAILED - ALL THE FILES SUBMITTED ARE | | | NOT ELECTRONICALLY SEALED. PAGES MISSED ARE S-001; | | | S-100; S-101; E-101 | | | | | | * PROFESSIONAL ENGINEERS- ALL ELECTRONIC SUBMISSIONS | | | PREPARED BY AN ENGINEER MUST COMPLY WITH 61G15-23.001 | | | AND BE EITHER DIGITALLY SIGNED AND SEALED -OR- | | | ELECTRONICALLY SIGNED AND SEALED, IN ACCORDANCE WITH | | | 61G15-23.004 AND 61G15-23.005 F.A.C. RESPECTIVELY. | | | * ARCHITECTS- ALL ELECTRONIC SUBMISSIONS PREPARED BY AN | | | ARCHITECT MUST COMPLY WITH 61G1-16.004 F.A.C. AND BE | | | DIGITALLY SIGNED AND SEALED IN ACCORDANCE WITH | | | 61G1-16.005 F.A.C. | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-11-17 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-11-17 14:24:32 | SIGNATURE REVIEW FAILED - ALL THE FILES SUBMITTED ARE | | | NOT ELECTRONICALLY SEALED. PAGES MISSED ARE S-001; | | | S-100; S-101; E-101 | | | | | | * PROFESSIONAL ENGINEERS- ALL ELECTRONIC SUBMISSIONS | | | PREPARED BY AN ENGINEER MUST COMPLY WITH 61G15-23.001 | | | AND BE EITHER DIGITALLY SIGNED AND SEALED -OR- | | | ELECTRONICALLY SIGNED AND SEALED, IN ACCORDANCE WITH | | | 61G15-23.004 AND 61G15-23.005 F.A.C. RESPECTIVELY. | | | * ARCHITECTS- ALL ELECTRONIC SUBMISSIONS PREPARED BY AN | | | ARCHITECT MUST COMPLY WITH 61G1-16.004 F.A.C. AND BE | | | DIGITALLY SIGNED AND SEALED IN ACCORDANCE WITH | | | 61G1-16.005 F.A.C. | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-09-30 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-30 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-30 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2022-09-30 08:49:13 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) STRUCTURAL DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED | | | IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-02 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-02 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2022-09-02 14:30:39 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE STRUCTURAL DRAWING DOES NOT SHOW AS DIGITALLY | | | SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2023-06-27 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-06-27 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-06-27 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
ASangele |
Date |
2023-01-26 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-01-26 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2023-01-26 15:09:13 | FAILED | | | 1/26/2023 | | | | | | DOESNT MEET MIMIMUM SETBACK REQUIREMENTS | | | ATRICLE VII. SECTION 94-202 | | | | | | MINIMUM SETBACKS: | | | FRONT: 25 FEET. | | | SIDE: 15 FEET. | | | REAR: 15 FEET. | | | MINIMUM BUILDING SEPARATION: 15 FEET. | | | | | | ALEXIS SANGELEER | | | PLANNER | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2023-01-04 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2022-12-06 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2022-12-06 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2022-12-06 15:39:16 | 12/6/22- FAILED. REPEAT COMMENT. SHOW SETBACKS FOR THE | | | EXPANSION AS IT RELATES TO THE PROPERTY LINE. | | | | | | ANGELLA VANN | | | 561-822-1441 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-10-06 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-10-06 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-10-06 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2022-10-06 15:07:05 | 10/06/22 FAILED | | | | | | NEED TO PROVIDE ALL MEASUREMENTS OF THE EXISTING | | | BUILDING, EVEN IF IT IS NOT IN THE SCOPE OF WORK. THIS | | | IS SO I CAN VERIFY YOU ARE COMPLYING WITH THE | | | REQUIREMENTS SET FORTH IN SEC. 94-202. SEE REQUIREMNTS | | | BELOW | | | | | | MINIMUM SETBACKS: | | | FRONT: 25 FEET. | | | SIDE: 15 FEET. | | | REAR: 15 FEET. | | | | | | MINIMUM BUILDING SEPARATION: 15 FEET. | | | | | | MAXIMUM LOT COVERAGE BY BUILDINGS: 60 PERCENT. | | | | | | MAXIMUM COVERAGE BY IMPERVIOUS SURFACES: 85 PERCENT. | | | | | | MAXIMUM BUILDING HEIGHT: 60 FEET. | | | | | | MAXIMUM FLOOR AREA RATIO: MAXIMUM FLOOR AREA RATIO | | | SHALL BE 0.75. | | | | | | MINIMUM REQUIRED OPEN SPACE AREA. THE REQUIRED OPEN | | | SPACE AREA SHALL BE 40 PERCENT OF TOTAL LOT AREA. SPACE | | | AREA MAY CONSIST OF SETBACKS, LANDSCAPE AND BUFFER | | | AREAS, AND PARKING LOT AREAS. | | | | | | MINIMUM REQUIRED LANDSCAPE AREA. THE MINIMUM REQUIRED | | | LANDSCAPE AREA SHALL BE 15 PERCENT OF TOTAL LOT AREA. | | | | | | ALEXANDER FOWLKES | | | [email protected] | | | 5618221431 |
|
|