| Plan Review Stops For Permit 22070445 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-22 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-22 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-08-05 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-05 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2022-08-05 09:29:40 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: HTTP://PALM | | | BEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICES/ENVIRONME | | | NTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE ADDRESS, PERMIT NUMBER AND ?ASBESTOS? IN | | | THE SUBJECT LINE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-22 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-22 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-08-05 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-05 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-10-18 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-10-18 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-10-17 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-10-17 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2022-10-17 09:42:00 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | SYMBOLS MISSING FOR MOST DEVICES, PLEASE PROVIDE SO WE | | | WILL KNOW WHICH SYSTEMS ARE BEING INSTALLED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-08-31 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-31 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-26 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2022-08-31 10:52:43 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | PLANS ARE INCOMPLETE, MISSING WALLS AND RISER DIAGRAM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-07-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-07-23 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-07-23 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2022-07-23 09:40:30 | PLEASE CHECK PLANS THERE IS SOMETHING WRONG WITH THEM | | | NOT READABLE. MISSING WALLS AND SYMBOLS JLEAHY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-08-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-08-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-08-25 |
Time |
15:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-07-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-07-15 |
Time |
11:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-10-20 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-20 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-10-19 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-10-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-10-19 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-23 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-22 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-24 |
Time |
17:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-18 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-08-18 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-07-14 |
Time |
14:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-15 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-15 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2022-10-20 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-20 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2022-09-26 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-09-26 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-09-26 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2022-09-26 09:23:50 | 3RD PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. --THE MIXING VALVE FOR "HOT WATER" DELIVERY MUST BE | | | PLACED AT THE HOT WATER SOURCE PER MY PREVIOUS COMMENT. | | | 2020 FPC 613.1 | | | | | | -- NOT ADDRESSED -- ALL HOT WATER MUST BE LIMITED BY A | | | DEVICE "OTHER THAN THE THERMOSTAT ON THE WATER HEATER". | | | (607.1.1) AND PER 613.1 MUST BE INSTALLED AT THE HOT | | | WATER SOURCE. YOUR RESPONSE ADDRESSES TEMPERED WATER, | | | NOT HOT WATER. YOUR DETAIL FOR TEMPERED WATER IS | | | SUFFICIENT. | | | 2020 FPC - 607.1.1 TEMPERATURE LIMITING MEANS - THE | | | THERMOSTAT CONTROL ON THE WATER HEATER CANNOT BE THE | | | LIMITING DEVICE FOR HOT WATER DELIVERY. PLEASE PROVIDE | | | A DETAIL FOR A LIMITING DEVICE FOR THE PURPOSE OF HOT | | | WATER DELIVERY. THIS WOULD BE IN ADDTION TO THE | | | REQUIREMENTS FOR TEMPERED WATER FOR PUBLIC HANDWASHING | | | 607.1.2/419.5. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-08-25 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-08-25 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-08-25 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2022-08-25 07:18:22 | 2ND PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. -- NOT ADDRESSED -- ALL HOT WATER MUST BE LIMITED BY | | | A DEVICE "OTHER THAN THE THERMOSTAT ON THE WATER | | | HEATER". (607.1.1) AND PER 613.1 MUST BE INSTALLED AT | | | THE HOT WATER SOURCE. YOUR RESPONSE ADDRESSES TEMPERED | | | WATER, NOT HOT WATER. YOUR DETAIL FOR TEMPERED WATER IS | | | SUFFICIENT. | | | 2020 FPC - 607.1.1 TEMPERATURE LIMITING MEANS - THE | | | THERMOSTAT CONTROL ON THE WATER HEATER CANNOT BE THE | | | LIMITING DEVICE FOR HOT WATER DELIVERY. PLEASE PROVIDE | | | A DETAIL FOR A LIMITING DEVICE FOR THE PURPOSE OF HOT | | | WATER DELIVERY. THIS WOULD BE IN ADDTION TO THE | | | REQUIREMENTS FOR TEMPERED WATER FOR PUBLIC HANDWASHING | | | 607.1.2/419.5. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-07-18 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-18 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-07-18 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2022-07-18 09:17:44 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FPC - 607.1.1 TEMPERATURE LIMITING MEANS - THE | | | THERMOSTAT CONTROL ON THE WATER HEATER CANNOT BE THE | | | LIMITING DEVICE FOR HOT WATER DELIVERY. PLEASE PROVIDE | | | A DETAIL FOR A LIMITING DEVICE FOR THE PURPOSE OF HOT | | | WATER DELIVERY. THIS WOULD BE IN ADDITION TO THE | | | REQUIREMENTS FOR TEMPERED WATER FOR PUBLIC HANDWASHING | | | 607.1.2/419.5. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-10-20 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-20 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-10-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-10-19 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-19 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2022-10-19 13:11:35 | ALL PLANS PASSED SIGNATURE REVIEW. MP | | 2022-10-17 09:45:25 | ELECTRICAL PAGES SIGNATURES ARE APPROVED JLEAHY |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-22 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-22 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-18 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-07-18 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2022-08-05 13:22:14 | THE ENGINEER, JAVAD AHMAD'S DIGITAL SIGNATURE ON THE | | | DRAWINGS IS SELF-CERTIFIED. THE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS REQUIRES ENGINEERS TO USE AN | | | APPROVED THIRD PARTY AGENCY TO CERTIFY THEIR | | | SIGNATURES. FS 471 & FAC 61G15 | | | | | | | | 2022-07-15 11:02:01 | MECHANICAL DIGITAL SIGNATURES APPROVED ME | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-29 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-08-29 |
Time |
09:35 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2022-08-29 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-18 |
|
|
Cont ID |
|
| Sent By |
escheide |
Date |
2022-08-18 |
Time |
10:14 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2022-08-18 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2022-08-18 10:17:39 | FAILED | | | | | | 1) THE ELEVATIONS, FLOOR PLAN AND NOTE THAT THE SIGN | | | J-BOX IS INSIDE THE STORE ROOF COMPLY WITH ZONING. | | | | | | 2) THE MECHANICAL SHEETS ARE ILLEGIBLE SO ZONING IS | | | UNABLE TO DETERMINE IF THERE IS ANY NEW ROOFTOP | | | MECHANICAL EQUIPMENT. IF NONE, PLANS PASS ZONING. IF | | | NEW ROOFTOP MECHANICAL, YOU MUST PROVIDE VERIFICATION | | | OF COMPLIANT SCREENING. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|