| Plan Review Stops For Permit 22070334 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-10-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-31 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-31 |
Time |
05:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-10-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-01 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-09-26 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2022-10-01 10:12:44 | 2ND BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. SEE | | | BELOW: | | | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC 110.9, NEW CONSTRUCTION ACTIVITY SHALL NOT | | | ADVERSELY IMPACT LEGAL HISTORIC SURFACE WATER DRAINAGE | | | FLOWS SERVING ADJACENT PROPERTIES. | | | | | | SUBMIT A DRAINAGE PLAN. | | | | | | 2. FBC 107, SUBMIT A SURVEY FOR THIS PROPERTY WHICH | | | SHOWS ALL EASEMENTS OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-09-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-27 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-27 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2022-07-27 15:37:35 | ORIGINAL REVIEW DELETED IN ERROR (SORRY!) | | | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC 110.9, NEW CONSTRUCTION ACTIVITY SHALL NOT | | | ADVERSELY IMPACT LEGAL HISTORIC SURFACE WATER DRAINAGE | | | FLOWS SERVING ADJACENT PROPERTIES. | | | | | | SUBMIT A DRAINAGE PLAN. | | | | | | 2. FBC 107, SUBMIT A SURVEY FOR THIS PROPERTY WHICH | | | SHOWS ALL EASEMENTS OF RECORD. | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-08-05 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-08-05 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-11-01 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-11-01 |
Time |
07:04 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-10-20 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-10-19 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-10-19 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-09-08 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-08 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-08-08 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-07-19 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
N |
Date |
2022-10-31 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-31 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-31 |
Time |
05:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-10-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-10-01 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-10-01 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2022-10-01 10:17:11 | 2ND SIGNATURE REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | | VALID DIGITAL SIGNATURE. A SCAN OF A WET SEAL AND | | | SIGNATURE OR DIGITAL SIGNATURE IS NOT CONSIDERED A | | | VALID DIGITAL SIGNATURE. | | | SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-07-19 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-07-19 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-07-19 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2022-07-19 16:07:18 | SIGNATURE REVIEW FAILED | | | 1) PAPER PLAN LABELED HARDSCAPE IS A COPY OF A COPY OF | | | A DIGITAL SIGNATURE | | | | | | FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF | | | RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | DIGITALLY SEALED AND SIGNED. | | | | | | PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS | | | FOLLOWING PROJECTDOX INSTRUCTIONS | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-10-31 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-10-31 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-10-31 |
Time |
12:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-10-18 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-10-18 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-08-05 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-08-05 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|