Plan Review Details - Permit 22070299
| Plan Review Stops For Permit 22070299 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-10-12 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-10-12 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-10-12 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-09-19 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-09-19 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-09-19 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2022-09-19 14:39:21 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R36 | | | (NON-HVHZ) SELECTED PRODUCT POLYSTICK TU MAX IN SECTION | | | 5.7 ALLOWABLE SUBSTRATES TABLE 2 ON PAGE 6 LIST | | | POLYSTICK TU MAX AS A SELF-ADHERING INSTALLATION. | | | SECTION 5.8.2 REFERENCE A TWO-PLY ASPHALT APPLIED HOT | | | MOP UNDERLAYMENT. IF USING A HOT MOP SYSTEM TABLE 2 | | | LIST ELATOFLEX S6 G OR ELASOFLEX S6 G FR AS THE ONLY | | | APPROVED PRODUCTS FOR HOT ASPHALT INSTALLATION. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-08-29 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-08-29 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-08-29 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2022-08-29 13:18:11 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R36 | | | COVERS MULTIPLE ATTACHMENT LIMITATIONS. SELECT | | | ATTACHMENT LIMITATION SYSTEM USED FROM 5.8.3.2 | | | MECHANICALLY ATTACHED BASE SHEET PAGES #8-16. SELECTED | | | SYSTEM MUST MEET OR EXCEED THE MINIMUM DESIGN PRESSURE | | | REQUIREMENTS FOR A HIP ROOF; 6/12 ROOF SLOPE; MEAN ROOF | | | HEIGHT 25 FT. MINIMUM DESIGN PRESSURE REQUIREMENT OF | | | -78 AS PER CHAPTER 3 OF THE 2020 FBC RESIDENTIAL. | | | SELECT SYSTEM THAT MEETS OR EXCEEDS THIS REQUIREMENT. | | | ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-29 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-07-29 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-07-29 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2022-07-29 08:48:09 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R34 | | | (NON-HVHZ) HAS BEEN REVISED TO FL5259-R35. PLEASE | | | PROVIDE A COMPLETE SET; IT COVERS MULTIPLE PRODUCT | | | TYPES; ROOF COVER OPTIONS; ALLOWABLE | | | UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS, ALLOWABLE | | | SUBSTRATES & ATTACHMENT LIMITATIONS. SELECT OPTIONS | | | FROM EACH CATEGORY TO BE USED. ALL APPLICABLE DETAILS | | | AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE | | | PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS NOT | | | SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED | | | SITE-SPECIFIC ENGINEERING | | | 2. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 | | | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED | | | HIP & RIDGE METAL TO BE USED. (FL5374-R6) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-10-12 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-10-12 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-10-05 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-09-19 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-09-19 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-09-16 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-08-29 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-08-29 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-08-18 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-29 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-07-29 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-07-28 |
Time |
07:14 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy