Plan Review Details - Permit 22070278
| Plan Review Stops For Permit 22070278 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-08-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-08-10 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-08-10 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2022-08-10 11:12:46 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-12-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-12 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-12 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-09-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-08 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-08 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2022-09-08 13:27:32 | SIDEWALK | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE SHOW THE SIDEWALK WIDTH - FBC ACCESSIBILITY | | | 403.5.1 CLEAR WIDTH. | | | EXCEPT AS PROVIDED IN 403.5.2 AND 403.5.3, THE CLEAR | | | WIDTH OF WALKING SURFACES SHALL BE 36 INCHES (915 MM) | | | MINIMUM. | | | | | | FBC ACCESSIBILITY 403.5.3 PASSING SPACES. | | | AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN 60 | | | INCHES (1525 MM) SHALL PROVIDE PASSING SPACES AT | | | INTERVALS OF 200 FEET (61 M) MAXIMUM. PASSING SPACES | | | SHALL BE EITHER: A SPACE 60 INCHES (1525 MM) MINIMUM BY | | | 60 INCHES (1525 MM) MINIMUM; OR, AN INTERSECTION OF TWO | | | WALKING SURFACES PROVIDING A T-SHAPED SPACE COMPLYING | | | WITH 304.3.2 WHERE THE BASE AND ARMS OF THE T-SHAPED | | | SPACE EXTEND 48 INCHES (1220 MM) MINIMUM BEYOND THE | | | INTERSECTION. | | | | | | 2) PLEASE SHOW ANY SLOPES - FBC A 403.3 SLOPE. | | | THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE | | | STEEPER THAN 1:20. THE CROSS SLOPE OF WALKING SURFACES | | | SHALL NOT BE STEEPER THAN 1:48. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-08-09 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-08-09 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-08-09 11:07:26 | FIRE PROVISO COMMENT: | | | THE MEANS OF EGRESS SHALL BE CONTINUOUSLY MAINTAINED | | | FREE OF ALL OBSTRUCTIONS OR IMPEDIMENTS TO FULL INSTANT | | | USE IN THE CASE OF AN EMERGENCY. DO NOT BLOCK OR | | | BARRICADE THE EXITS FROM THE BUILDING TO THE PUBLIC | | | WAY. NFPA 101, 7.1.10 | | | C. WALKER | | | 561-804-4762 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-01-12 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-01-12 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-12-08 |
Time |
16:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-09-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-08 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-08-08 |
Time |
07:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-09-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-08 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-08 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-01-12 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2023-01-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2023-01-12 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-01-12 09:56:50 | ZONING APPROVED WITH THE FOLLOWING PROVISO: | | | | | | 1.) SCOPE OF WORK IS FOR THE REPLACEMENT/CHANGE OF | | | MATERIAL OF EXISTING WALKWAY AS SPECFIED IN THE ZONING | | | STAMPED PLAN. NO CHANGE IN EXISTING WALKWAY FOOTPRINT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-18 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2022-08-18 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2022-08-18 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-08-18 11:35:15 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) UPDATED SIGNED AND SEALED SURVEY OF THE PROPERTY | | | REQUIRED. | | | | | | 2.) SITE PLAN SHOWING THE EXISTING AND PROPOSED | | | IMPROVEMENT TO THE SITE SHALL BE PROVIDED. A WALKWAY | | | FOOTPRINT THAT DEVIATES FROM THE EXISTING FOOTPRINT MAY | | | TRIGGER A MINOR PLANNED DEVELOPMENT (PD) AMENDMENT TO | | | THE HANLEY CENTER COMMUNITY SERVICE PLANNED DEVELOPMENT | | | (CSPD). THE MINOR PD AMENDMENT PROCESS IS A SEPARATE | | | PROCESS THAT REQUIRES APPROVAL BY THE PLANNING DIVISION | | | PRIOR TO ZONING SIGN-OFF OF THIS PERMIT. | | | | | | | | | NOTES: | | | | | | * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: HANLEY CENTER CSPD (REFERENCE: PB 1564) | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy