Plan Review Details - Permit 22070278
Plan Review Stops For Permit 22070278
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-08-10 Cont ID  
Sent By cpuell Date 2022-08-10 Time 11:12 Rev Time 0.00
Received By cpuell Date 2022-08-10 Time 11:12 Sent To  
Notes
2022-08-10 11:12:46ADDRESS APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-12-12 Cont ID  
Sent By rmcphers Date 2022-12-12 Time 08:00 Rev Time 0.00
Received By rmcphers Date 2022-12-12 Time 08:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-08 Cont ID  
Sent By rmcphers Date 2022-09-08 Time 13:19 Rev Time 0.00
Received By rmcphers Date 2022-09-08 Time 13:19 Sent To  
Notes
2022-09-08 13:27:32SIDEWALK
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE SIDEWALK WIDTH - FBC ACCESSIBILITY
 403.5.1 CLEAR WIDTH.
 EXCEPT AS PROVIDED IN 403.5.2 AND 403.5.3, THE CLEAR
 WIDTH OF WALKING SURFACES SHALL BE 36 INCHES (915 MM)
 MINIMUM.
  
 FBC ACCESSIBILITY 403.5.3 PASSING SPACES.
 AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN 60
 INCHES (1525 MM) SHALL PROVIDE PASSING SPACES AT
 INTERVALS OF 200 FEET (61 M) MAXIMUM. PASSING SPACES
 SHALL BE EITHER: A SPACE 60 INCHES (1525 MM) MINIMUM BY
 60 INCHES (1525 MM) MINIMUM; OR, AN INTERSECTION OF TWO
 WALKING SURFACES PROVIDING A T-SHAPED SPACE COMPLYING
 WITH 304.3.2 WHERE THE BASE AND ARMS OF THE T-SHAPED
 SPACE EXTEND 48 INCHES (1220 MM) MINIMUM BEYOND THE
 INTERSECTION.
  
 2) PLEASE SHOW ANY SLOPES - FBC A 403.3 SLOPE.
 THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE
 STEEPER THAN 1:20. THE CROSS SLOPE OF WALKING SURFACES
 SHALL NOT BE STEEPER THAN 1:48.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-08-09 Cont ID  
Sent By cwalker Date 2022-08-09 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-08-09 11:07:26FIRE PROVISO COMMENT:
 THE MEANS OF EGRESS SHALL BE CONTINUOUSLY MAINTAINED
 FREE OF ALL OBSTRUCTIONS OR IMPEDIMENTS TO FULL INSTANT
 USE IN THE CASE OF AN EMERGENCY. DO NOT BLOCK OR
 BARRICADE THE EXITS FROM THE BUILDING TO THE PUBLIC
 WAY. NFPA 101, 7.1.10
 C. WALKER
 561-804-4762
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-01-12 Cont ID  
Sent By lmarchan Date 2023-01-12 Time 12:54 Rev Time 0.00
Received By lmarchan Date 2022-12-08 Time 16:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-08 Cont ID  
Sent By rmcphers Date 2022-09-08 Time 13:28 Rev Time 0.00
Received By rmcphers Date 2022-08-08 Time 07:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-09-08 Cont ID  
Sent By rmcphers Date 2022-09-08 Time 13:27 Rev Time 0.00
Received By rmcphers Date 2022-09-08 Time 13:27 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2023-01-12 Cont ID  
Sent By llouie Date 2023-01-12 Time   Rev Time 0.00
Received By llouie Date 2023-01-12 Time   Sent To  
Notes
2023-01-12 09:56:50ZONING APPROVED WITH THE FOLLOWING PROVISO:
  
 1.) SCOPE OF WORK IS FOR THE REPLACEMENT/CHANGE OF
 MATERIAL OF EXISTING WALKWAY AS SPECFIED IN THE ZONING
 STAMPED PLAN. NO CHANGE IN EXISTING WALKWAY FOOTPRINT.

Review Stop Z ZONING
Rev No 1 Status F Date 2022-08-18 Cont ID  
Sent By llouie Date 2022-08-18 Time   Rev Time  
Received By llouie Date 2022-08-18 Time   Sent To  
Notes
2022-08-18 11:35:15** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) UPDATED SIGNED AND SEALED SURVEY OF THE PROPERTY
 REQUIRED.
  
 2.) SITE PLAN SHOWING THE EXISTING AND PROPOSED
 IMPROVEMENT TO THE SITE SHALL BE PROVIDED. A WALKWAY
 FOOTPRINT THAT DEVIATES FROM THE EXISTING FOOTPRINT MAY
 TRIGGER A MINOR PLANNED DEVELOPMENT (PD) AMENDMENT TO
 THE HANLEY CENTER COMMUNITY SERVICE PLANNED DEVELOPMENT
 (CSPD). THE MINOR PD AMENDMENT PROCESS IS A SEPARATE
 PROCESS THAT REQUIRES APPROVAL BY THE PLANNING DIVISION
 PRIOR TO ZONING SIGN-OFF OF THIS PERMIT.
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: HANLEY CENTER CSPD (REFERENCE: PB 1564)
  