Plan Review Details - Permit 22070175
Plan Review Stops For Permit 22070175
Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-04-19 Cont ID  
Sent By lmarchan Date 2023-04-19 Time 08:44 Rev Time 0.00
Received By lmarchan Date 2023-04-17 Time 16:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-04-14 Cont ID  
Sent By rwbrown Date 2023-04-14 Time 11:04 Rev Time 0.00
Received By rwbrown Date 2023-04-12 Time 18:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-04-11 Cont ID  
Sent By aoliver Date 2023-04-11 Time 16:50 Rev Time 0.00
Received By aoliver Date 2023-04-07 Time 13:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-28 Cont ID  
Sent By lmarchan Date 2022-07-28 Time 11:24 Rev Time 0.00
Received By lmarchan Date 2022-07-27 Time 05:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2023-04-18 Cont ID  
Sent By rwbrown Date 2023-04-18 Time 06:46 Rev Time 0.00
Received By rwbrown Date 2023-04-18 Time 06:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2023-04-14 Cont ID  
Sent By rwbrown Date 2023-04-14 Time 11:02 Rev Time 0.00
Received By rwbrown Date 2023-04-14 Time 11:02 Sent To  
Notes
2023-04-14 11:04:283RD PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 NOT SURE WHY YOU UPLOADED ANOTHER SURVEY/SITE PLAN. IT
 IS THE SPEC SHEET THAT NEEDS REPLACED WITH ONE THAT
 SAYS "LEAD FREE".
  
 1. 2020 FPC 605.2.1 - THE SPEC SHEET MUST SAY THAT IT
 IS "LEAD FREE" AND BE IN COMPLIANCE WITH NSF 372. THE
 SPEC SHEET YOU'VE SUPPLIED SAYS "IT IS ILLEGAL TO USE
 THIS PRODUCT IN ANY PLUMBING SYSTEM PROVIDING WATER FOR
 HUMAN CONSUMPTION....ETC"
 PLEASE SUPPLY A SPEC SHEET FOR A "LEAD FREE" DEVICE.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-04-10 Cont ID  
Sent By rwbrown Date 2023-04-10 Time 06:04 Rev Time 0.00
Received By rwbrown Date 2023-04-10 Time 06:04 Sent To  
Notes
2023-04-10 06:06:192ND PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FPC 605.2.1 - THE SPEC SHEET MUST SAY THAT IT
 IS "LEAD FREE" AND BE IN COMPLIANCE WITH NSF 372. THE
 SPEC SHEET YOU'VE SUPPLIED SAYS "IT IS ILLEGAL TO USE
 THIS PRODUCT IN ANY PLUMBING SYSTEM PROVIDING WATER FOR
 HUMAN CONSUMPTION....ETC"
 PLEASE SUPPLY A SPEC SHEET FOR A "LEAD FREE" DEVICE.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-07-27 Cont ID  
Sent By rwbrown Date 2022-07-27 Time 07:07 Rev Time 0.00
Received By rwbrown Date 2022-07-27 Time 07:06 Sent To  
Notes
2022-07-27 07:08:151ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMEND - 107.3.5 - PLEASE PROVIDE A BASIC
 SITE PLAN SHOWING THE LOCATION OF THE BACKFLOW
 PREVENTER
  
 2. 2017 WPB AMEND - 107.3.5 - PLEASE PROVIDE SPEC SHEET
 FOR THE BACKFLOW DEVICE TO BE INSTALLED. IT NEEDS TO
 INDICATE IT IS LEAD FREE AND USC APPROVED. BE SURE TO
 HIGHLIGHT THE MAKE, MODEL, AND SIZE OF THE DEVICE.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop PU PUBLIC UTILITIES
Rev No 5 Status P Date 2023-04-19 Cont ID  
Sent By lmarchan Date 2023-04-19 Time 15:16 Rev Time 0.00
Received By lmarchan Date 2023-04-19 Time 15:16 Sent To  
Notes
***NONE***

Review Stop PU PUBLIC UTILITIES
Rev No 4 Status F Date 2023-04-19 Cont ID  
Sent By lmarchan Date 2023-04-19 Time 08:44 Rev Time 0.00
Received By lmarchan Date 2023-04-19 Time 08:44 Sent To  
Notes
2023-04-19 08:44:30PER RJENKINS - ALL EXISTING DEVICES RELOCATED MUST BE
 LEAD FREE.

Review Stop PU PUBLIC UTILITIES
Rev No 3 Status F Date 2023-04-14 Cont ID  
Sent By rwbrown Date 2023-04-14 Time 11:04 Rev Time 0.00
Received By rwbrown Date 2023-04-14 Time 11:04 Sent To  
Notes
2023-04-14 11:04:55PER DALTON GRIFFITHS - NEED TO HAVE A LEAD CONTENT OF
 0.25%

Review Stop PU PUBLIC UTILITIES
Rev No 2 Status F Date 2023-04-11 Cont ID  
Sent By aoliver Date 2023-04-11 Time 16:49 Rev Time 0.00
Received By aoliver Date 2023-04-11 Time 16:49 Sent To  
Notes
2023-04-11 16:50:15PER DALTON GRIFFITHS - NEED TO HAVE A LEAD CONTENT OF
 0.25%

Review Stop PU PUBLIC UTILITIES
Rev No 1 Status P Date 2022-07-28 Cont ID  
Sent By lmarchan Date 2022-07-28 Time 11:24 Rev Time 0.00
Received By lmarchan Date 2022-07-28 Time 11:24 Sent To  
Notes
***NONE***