Plan Review Details - Permit 22070105
Plan Review Stops For Permit 22070105
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-07-21 Cont ID  
Sent By cpuell Date 2022-07-21 Time 09:27 Rev Time 0.00
Received By cpuell Date 2022-07-21 Time 09:26 Sent To  
Notes
2022-07-21 09:27:29WORK TO BE DONE ON THE NORTH BUILDING WITH THE ADDRESS
 OF 213 MARLBOROUGH RD, UPDATED THE PERMITS DOCS TO
 REFLECT THE CORRECT ADDRESS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-01-12 Cont ID  
Sent By jgomez Date 2023-01-12 Time 16:12 Rev Time 0.00
Received By jgomez Date 2023-01-12 Time 15:20 Sent To  
Notes
2023-01-12 16:13:37BUILDING REVIEW APPROVED WITH PROVISO
 (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO
 INSTALLATION & INSPECTION TO AVOID CONFLICTS/DELAYS):
  
 (1)SHEET A-01:
 (A)PARAPET DETAIL ON SHEET A-01 IS INCOMPLETE. MISSING
 CONNECTOR FOR 2X4 SILL PLATE TO THE ROOF RAFTERS AND
 ATTACHMENT OF THE DOUBLE 2X4 TOP PLATE TO THE STUDS.
 (B)REVISE SIZE OF EMERGENCY OVERFLOW SCUPPERS. SEC.
 R903.4.1 FBC-RESIDENTIAL AND SEC. 1108.3 FBC-PLUMBING
 (OPENING WIDTH EQUAL TO THE CIRCUMFERENCE OF THE ROOF
 DRAIN REQUIRED FOR THE AREA SERVED).
  
 (2)PRODUCT APPROVALS DEFERRED SUBMITTAL: PROVIDE
 PRODUCT APPROVAL FOR:
 (A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY
 IS GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN
 SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED.
 (B)DOUBLE INSWING FRENCH DOORS AS SHOWN ON THE SECOND
 FLOOR.
 (C)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
 (D)ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS LISTED
 ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED.
 (E)SLOPED ROOF UNDERLAYMENT.
 (3)DESIGNER OF RECORD TO REVIEW AND APPROVE ALL PRODUCT
 APPROVALS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-12-28 Cont ID  
Sent By jgomez Date 2022-12-28 Time 13:41 Rev Time 0.00
Received By jgomez Date 2022-12-28 Time 09:41 Sent To  
Notes
2022-12-28 13:42:04RESIDENTIAL (R3) REVISION, ADDITION/ALTERATION THIRD
 BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PRMIT #22070105
 213 MARLBOROUGH RD
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES APPLY (NOTE: FEES DON'T
 APPLY TO PRODUCT APPROVAL SUBMITTAL, EXCEPT FOR PRODUCT
 APPROVALS ALREADY REVIEWED/APPROVED).
  
 ***IMPORTANT****CONTRACTOR TO ADVICE IF PROVISO OPTION
 IS PREFERRED AT THIS TIME OR IF RE-SUBMITTING REQUIRED
 INFORMATION BEFORE PERMIT ISSUANCE.
  
  
 1-6 OK.
  
 ORIGINAL COMMENT:
 7- PROVIDE COMPLETE FRAMING PLANS, SECTIONS AND
 SPECIFICATIONS FOR RE-CONSTRUCTION OF WOOD CORNICE &
 BARREL TILE ROOF SHOWN ON PLANS FOR FIRST FLOOR.
 SPECIFY ALL FRAMING MEMBERS AND CONNECTORS, ETC. SEC.
 R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 PARAPET DETAIL ON SHEET A-01 IS INCOMPLETE. IT DOESN'T
 SPECIFY ALL FRAMING MEMBERS AND ALL CONNECTORS FOR
 PARAPET WALL. NEED TO PROVIDE THIS INFORMATION.
  
 ORIGINAL COMMENT:
 8- CLARIFY/REVISE SIZE OF EMERGENCY OVERFLOW SCUPPERS
 SPECIFIED ON PLANS. SEC. R903.4.1 FBC-RESIDENTIAL.
 NOTE: 2" EMERGENCY OVERFLOW SCUPPER DOESN'T COMPLY.
  
 RESPONSE:
 EMERGENCY OVERFLOW SCUPPER SIZE (4"H X 2"W) DOESN'T
 COMPLY. SEE SEC. 1108.3 FBC-PLUMBING AS REQUIRED BY
 SEC. R903.4.1 FBC-RESIDENTIAL AND REVISE SIZE.
  
 9- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 ORIGINAL COMMENT:
 A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS
 GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN
 SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED.
  
 RESPONSE:
 THERE ARE TWO DIFFERENT PRODUCT APPROVALS UPLOADED IN
 THE SAME PDF FILE. ONE IS CERTAINTEED FLORIDA PRODUCT
 APPROVAL FL2533-R28 AND THE OTHER ONE IS CERTAINTEED
 NOA 17-1003.15. IMPORTANT NEED TO SUBMIT ONLY ONE
 PRODUCT APPROVAL TO AVOID CONFLICTS.
  
 NOTE:
 EITHER PRODUCT APPROVAL REQUIRES SIGNED AND SEALED RAS
 117 CALCULATIONS BECAUSE THE SELECTED ASSEMBLIES DON'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES. THE
 MAXIMUM DESIGN PRESSURES (MDP) ON SELECTED ASSEMBLY
 W-77 CERTAINTEED FLORIDA PRODUCT APPROVAL FL2533-R28 IS
 -60PSF. AND THE DESIGN PRESSURES ON CERTAINTEED NOA
 17-1003.15 WERE NO IDENTIFIED BECAUSE NO ASSEMBLY WAS
 SELECTED. NEVERTHELESS NONE OF THE ASSEMBLIES ON NOA
 SUBMITTED MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES.
 NOTE: WHEN SELECTING AN ASSEMBLY MAKE SURE SELECTED
 ASSEMBLY IS NOT LIMITED BY GENERAL LIMITATION #9
 BECAUSE THIS LIMITATION DOESN'T ALLOW NAIL ENHANCEMENT.
 SEE GENERAL LIMITATION #9 ON LAST PAGE OF NOA.
 SEC.107.2.1 CITY AMENDMENTS.
  
 PREVIOUS COMMENT:
 B) ARCHITECT'S RESPONSE LETTER STATES "GC REVISED
 OUTSWING FRENCH DOOR SUBMITTAL. NEW SUBMITTAL
 ATTACHED.".
 NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW.
 NOTE: NEED PRODUCT APPROVAL FOR INSWING FRENCH DOORS AS
 SHOWN ON THE SECOND FLOOR. CHECK DESIGN PRESSURES
 SPECIFIED ON PLANS.
  
 RESPONSE:
 PRODUCT APPROVAL FOR SINGLE "OUTSWING" DOOR WAS
 SUBMITTED BUT PRODUCT APPROVAL FOR DOUBLE INSWING DOORS
 WAS NOT SUBMITTED.
  
 ORIGINAL COMMENT:
 C)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 THERE ARE TWO DIFFERENT PRODUCT APPROVALS UPLOADED IN
 THE SAME PDF FILE. ONE IS CERAMICA VEREA FLORIDA
 PRODUCT APPROVAL FL17152-R4 AND THE OTHER ONE IS TEJAS
 VEREA NOA 20-0902.03. IMPORTANT NEED TO SUBMIT ONLY ONE
 PRODUCT APPROVAL AND CLEARLY MARK FASTENING METHOD TO
 AVOID CONFLICTS
 NOTE: FLORIDA PRODUCT APPROVAL FL17152-R4 IS NOT MARKED
 SHOWING THE FASTENING METHOD. NOA 20-0902.03 IS MARKED
 WITH AH-160 ADHESIVE ON PAGE 5 OF 9. THIS FASTENING
 METHOD IS OK FOR ALL ROOF ZONES BUT ADHESIVE PRODUCT
 APPROVAL SUBMITTED DOESN'T MATCH AH-160 ADHESIVE LISTED
 IN THE NOA. COORDINATE AS REQUIRED TO AVOID MORE
 CONFLICTS/DELAYS. SEC.107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 D)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS
 LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED.
  
 RESPONSE:
 COORDINATE WITH ITEM #9(C) ABOVE TO AVOID MORE
 CONFLICTS/DELAYS. SEC.107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 E) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY
 MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC.
 R905.3.7.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 FLORIDA PRODUCT APPROVAL FL5374-R6 SUBMITTED IS OK.
 NOTE: COORDINATE ROOF TILE ADHESIVE WITH ITEM #9(C)
 ABOVE TO AVOID MORE CONFLICTS/DELAYS. SEC.107.2.1 CITY
 AMENDMENTS.
  
 ORIGINAL COMMENT:
 10- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 RESPONSE:
 NOT ADDRESSED.
 NOTE: THIS COMMENT APPLIES TO ALL PRODUCT APPROVALS
 SUBMITTED, INCLUDING ONES SUBMITTED EARLIER.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-10-05 Cont ID  
Sent By jgomez Date 2022-10-05 Time 16:39 Rev Time 0.00
Received By jgomez Date 2022-10-04 Time 18:22 Sent To  
Notes
2022-10-05 16:40:07RESIDENTIAL (R3) REVISION, ADDITION/ALTERATION SECOND
 BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PRMIT #22070105
 213 MARLBOROUGH RD
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY.
 ***IMPORTANT****CONTRACTOR TO ADVICE IF PROVISO OPTION
 IS PREFERRED AT THIS TIME OR IF RE-SUBMITTING REQUIRED
 INFORMATION BEFORE PERMIT ISSUANCE.
  
  
 1- OK.
 2- OK.
 3- OK.
 4- OK.
  
 ORIGINAL COMMENT:
 5- GUARDRAILS: DESIGNER OF RECORD NEEDS TO PROVIDE THE
 DETAILS AND SPECIFICATIONS FOR THE CONSTRUCTION OF THE
 BALCONY GUARDRAILS AS REQUIRED BY TABLE R301.5, SEC.
 AND SEC. R312.1 FBC-RESIDENTIAL.
 NOTE: SUBSEQUENT SHOP DRAWINGS ARE TO CONFIRM THAT
 DESIGN DETAILS AND SPECIFICATIONS ARE MET.
  
 RESPONSE:
 PARTIALLY DONE. NO SPECS FOR PICKETS SPACING. ALSO,
 GUARDRAIL NOTE ON SHEET A-03 SAYS "SEE STRUCTURAL DWGS
 FOR CONNECTION DETAILS (TYP)". INFORMATION WAS NOT
 PROVIDED EITHER.
  
 6- ARCHITECT IS SPECIFYING R-30 CLOSED CELL SPRAY FOAM
 CEILING INSULATION. PROVIDE ICC EVALUATION REPORT FOR
 THE ICYNENE R-30 INSULATION TO VERIFY COMPLIANCE WITH
 SEC. R316 FBC-RESIDENTIAL.
 NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 RESPONSE:
 NO SUBMITTED.
  
 ORIGINAL COMMENT:
 7- PROVIDE COMPLETE FRAMING PLANS, SECTIONS AND
 SPECIFICATIONS FOR RE-CONSTRUCTION OF WOOD CORNICE &
 BARREL TILE ROOF SHOWN ON PLANS FOR FIRST FLOOR.
 SPECIFY ALL FRAMING MEMBERS AND CONNECTORS, ETC. SEC.
 R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 PARAPET DETAIL ON SHEET A-01 IS INCOMPLETE. IT DOESN'T
 SPECIFY ALL THE FRAMING MEMBERS AND CONNECTORS FOR
 PARAPET WALL. NEED TO PROVIDE THIS INFORMATION.
  
 ORIGINAL COMMENT:
 8- CLARIFY/REVISE SIZE OF EMERGENCY OVERFLOW SCUPPERS
 SPECIFIED ON PLANS. SEC. R903.4.1 FBC-RESIDENTIAL.
 NOTE: 2" EMERGENCY OVERFLOW SCUPPER DOESN'T COMPLY.
  
 RESPONSE:
 EMERGENCY OVERFLOW SCUPPER SIZE (4"H X 2"W) DOESN'T
 COMPLY. SEE SEC. 1108.3 FBC-PLUMBING AS REQUIRED BY
 SEC. R903.4.1 FBC-RESIDENTIAL AND REVISE SIZE.
  
  
 9- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 ORIGINAL COMMENT:
 A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS
 GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN
 SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED.
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES "GC REVISED FLAT
 ROOF SUBMITTAL. NEW SUBMITTAL ATTACHED.".
 NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW.
  
 ORIGINAL COMMENT:
 B)SINGLE OUTSWING FRENCH DOOR FL34006 SUBMITTED:
 INSTALLATION INSTRUCTIONS DRAWING W17-108 SUBMITTED
 DON'T MATCH DRAWING HIGHLIGHTED ON THE FLORIDA PRODUCT
 APPROVAL COVER PAGE. REVISE AS REQUIRED TO MATCH.
 NOTE: PLEASE UPLOAD THE FLORIDA PRODUCT APPROVAL COVER
 PAGE AND CORRESPONDING INSTALLATION DRAWINGS ON THE
 SAME PDF FILE. DO NOT UPLOAD IN SEPARATE FILES.
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES "GC REVISED OUTSWING
 FRENCH DOOR SUBMITTAL. NEW SUBMITTAL ATTACHED.".
 NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW.
 NOTE: NEED PRODUCT APPROVAL FOR INSWING FRENCH DOORS AS
 SHOWN ON THE SECOND FLOOR. CHECK DESIGN PRESSURES
 SPECIFIED ON PLANS.
  
 ORIGINAL COMMENT:
 C)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES "ROOF TILE AND PADDY
 SIZE ADDED. NEW SUBMITTAL ATTACHED.".
 NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW.
  
 ORIGINAL COMMENT:
 D)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS
 LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED.
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES "ROOF TILE ADHESIVE
 PRODUCT APPROVAL ATTACHED.".
 NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW.
  
 ORIGINAL COMMENT:
 E) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY
 MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC.
 R905.3.7.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES "HIP AND RIDGE
 PRODUCT APPROVAL ATTACHED.".
 NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW.
  
 ORIGINAL COMMENT:
 10- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 RESPONSE:
 NOT ADDRESSED.
 NOTE: THIS COMMENT APPLIES TO ALL PRODUCT APPROVALS
 SUBMITTED, INCLUDING ONES SUBMITTED EARLIER.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-08-05 Cont ID  
Sent By jgomez Date 2022-08-05 Time 18:28 Rev Time 0.00
Received By jgomez Date 2022-08-05 Time 17:10 Sent To  
Notes
2022-08-05 18:30:16RESIDENTIAL (R3) REVISION, ADDITION/ALTERATION BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22070105
 213 MARLBOROUGH RD
  
 NOTE:
 CHANGE OF OCCUPANCY SEC. 605 AND SEC. 1001.2.1, SEC.
 604 AND SEC. 901.2, SEC. 801.3 FBC-EXISTING BUILDING.
 ALL NEW WORK SHALL COMPLY WITH THE MATERIALS AND
 METHODS REQUIREMENTS IN THE FLORIDA BUILDING CODE.
  
 NOTE:
 LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING BUILDING.
 SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3
 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
  
 NOTE: THE FOLLOWING COMMENTS ARE BASED ON PLANS
 SUBMITTED UNDER MAIN HOUSE REVISION #22070103. WHEN
 ADDRESSING THE COMMENTS UNDER THIS PERMIT FOR THE
 DETACHED GARAGE, PLEASE SUBMIT ONLY THE DRAWINGS
 RELATED TO THE DETACHED GARAGE TO AVOID
 CONFLICTS/DELAYS.
  
 1- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW BASED ON ALL SCOPE OF WORK TO BE DONE ON THE
 DETACHED GARAGE (SHORING, DEMOLITION AND COMPLETE
 RENOVATION). VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. UPDATE VALUATION TO INCLUDE ALL COSTS.
 PROVIDE COMPLETE COST BREAKDOWN INCLUDING DESIGN
 PROFESSIONAL FEES.
  
 2- SHEET S-000:
 ENGINEER OF RECORD TO REVISE END ZONE DISTANCE "A"
 SPECIFIED FOR THE DETACHED GARAGE. THE MINIMUM
 DIMENSION IS 4'-0" NOT 3'-0" AS REQUIRED BY NOTE "A" ON
 FIGURE R301.2(7) FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 3- CLARIFY/REVISE SIZE SECOND FLOOR ENTRY DOOR (E2).
 EXTERIOR DOOR SCHEDULE ON SHEET A-09 SHOWS DOOR E2 AS
 36" X 96" INSWING FRENCH DOOR, BUT
 SECOND FLOOR PLAN ON SHEET A-02.1 CALL FOR 2'-10" DOOR
 OPENING. REVISE AS REQUIRED TO MATCH. NEED TO VERIFY
 ENTRY DOOR COMPLIANCE WITH EGRESS SEC. R311.2
 FBC-RESIDENTIAL.
  
 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 RECONSTRUCTION OF THE STAIRWAY SHOWING COMPLIANCE WITH
 SEC. R311.7 FBC-RESIDENTIAL.
 PROVIDE SPECS FOR STAIRWAY CONSTRUCTION AND SHOW
 HANDRAIL LOCATION AND HEIGHT, RISER AND TREADS
 DIMENSIONS INCLUDING NOSING.
  
 5- GUARDRAILS: DESIGNER OF RECORD NEEDS TO PROVIDE THE
 DETAILS AND SPECIFICATIONS FOR THE CONSTRUCTION OF THE
 BALCONY GUARDRAILS AS REQUIRED BY TABLE R301.5, SEC.
 AND SEC. R312.1 FBC-RESIDENTIAL.
 NOTE: SUBSEQUENT SHOP DRAWINGS ARE TO CONFIRM THAT
 DESIGN DETAILS AND SPECIFICATIONS ARE MET.
  
 6- ARCHITECT IS SPECIFYING R-30 CLOSED CELL SPRAY FOAM
 CEILING INSULATION. PROVIDE ICC EVALUATION REPORT FOR
 THE ICYNENE R-30 INSULATION TO VERIFY COMPLIANCE WITH
 SEC. R316 FBC-RESIDENTIAL.
 NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 7- PROVIDE COMPLETE FRAMING PLANS, SECTIONS AND
 SPECIFICATIONS FOR RE-CONSTRUCTION OF WOOD CORNICE &
 BARREL TILE ROOF SHOWN ON PLANS. SPECIFY ALL FRAMING
 MEMBERS AND CONNECTORS, ETC. SEC. R301.2.1
 FBC-RESIDENTIAL.
  
 8- CLARIFY/REVISE SIZE OF EMERGENCY OVERFLOW SCUPPERS
 SPECIFIED ON PLANS. SEC. R903.4.1 FBC-RESIDENTIAL.
 NOTE: 2" EMERGENCY OVERFLOW SCUPPER DOESN'T COMPLY.
  
 9- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS
 GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN
 SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED.
  
 B)SINGLE OUTSWING FRENCH DOOR FL34006 SUBMITTED:
 INSTALLATION INSTRUCTIONS DRAWING W17-108 SUBMITTED
 DON'T MATCH DRAWING HIGHLIGHTED ON THE FLORIDA PRODUCT
 APPROVAL COVER PAGE. REVISE AS REQUIRED TO MATCH.
 NOTE: PLEASE UPLOAD THE FLORIDA PRODUCT APPROVAL COVER
 PAGE AND CORRESPONDING INSTALLATION DRAWINGS ON THE
 SAME PDF FILE. DO NOT UPLOAD IN SEPARATE FILES.
  
 C)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
  
 D)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS
 LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED.
  
 E) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY
 MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC.
 R905.3.7.1 FBC-RESIDENTIAL.
  
 F)WINDOW MULLIONS NOA 19-0131.11 SUBMITTED. NOTE: NEED
 TO SPECIFY MULLION SIZE TO VERIFY PRESSURES. SEC.
 R301.2.1 FBC-RESIDENTIAL.
  
 10- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-10-05 Cont ID  
Sent By mpeterso Date 2022-10-05 Time 10:11 Rev Time 0.00
Received By mpeterso Date 2022-10-05 Time 10:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2022-08-01 Cont ID  
Sent By mpeterso Date 2022-08-01 Time 13:04 Rev Time 0.00
Received By mpeterso Date 2022-08-01 Time 13:04 Sent To  
Notes
2022-08-01 13:05:47NO ELECTRIC WORK SHOWN, REVIEWED OR APPROVED. MP

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2022-12-08 Cont ID  
Sent By amhamilt Date 2022-12-08 Time 09:52 Rev Time 0.00
Received By amhamilt Date 2022-12-08 Time 09:52 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2022-10-07 Cont ID  
Sent By amhamilt Date 2022-10-07 Time 16:15 Rev Time 0.00
Received By amhamilt Date 2022-10-07 Time 16:15 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2022-08-05 Cont ID  
Sent By fmittner Date 2022-08-05 Time 16:22 Rev Time 0.00
Received By fmittner Date 2022-08-05 Time 16:22 Sent To  
Notes
2022-08-05 16:22:33NOT ENOUGH INFOMATION PROVIDED. NEED ELEVATIONS AND
 SITE PLAN. ROOF MATERIAL ETC.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-02-01 Cont ID  
Sent By mpeterso Date 2023-02-01 Time 15:17 Rev Time 0.00
Received By mpeterso Date 2023-02-01 Time 15:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-01-12 Cont ID  
Sent By jgomez Date 2023-01-12 Time 16:18 Rev Time 0.00
Received By jgomez Date 2023-01-12 Time 14:45 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-12-28 Cont ID  
Sent By jgomez Date 2022-12-28 Time 14:10 Rev Time 0.00
Received By jgomez Date 2022-11-30 Time 15:03 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-10-11 Cont ID  
Sent By aoliver Date 2022-10-11 Time 09:28 Rev Time 0.00
Received By aoliver Date 2022-09-19 Time 08:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-08-05 Cont ID  
Sent By jgomez Date 2022-08-05 Time 18:33 Rev Time 0.00
Received By jgomez Date 2022-07-21 Time 08:12 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2023-01-31 Cont ID  
Sent By lmarchan Date 2023-01-31 Time 15:28 Rev Time 0.00
Received By lmarchan Date 2023-01-12 Time 16:40 Sent To  
Notes
2023-01-20 15:37:21RECEIPT MU-2023-002351 - $22.46 PAID
2023-01-12 16:40:521/12/23 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2022-12-28 Cont ID  
Sent By jgomez Date 2022-12-28 Time 13:42 Rev Time 0.00
Received By jgomez Date 2022-12-28 Time 13:42 Sent To  
Notes
2022-12-28 13:42:28IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2022-10-05 Cont ID  
Sent By jgomez Date 2022-10-05 Time 10:51 Rev Time 0.00
Received By jgomez Date 2022-10-04 Time 18:34 Sent To  
Notes
2022-10-05 10:51:44IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-08-05 Cont ID  
Sent By jgomez Date 2022-08-05 Time 17:14 Rev Time 0.00
Received By jgomez Date 2022-08-05 Time 17:14 Sent To  
Notes
2022-08-05 17:15:08IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-12-01 Cont ID  
Sent By medwards Date 2022-12-01 Time 15:44 Rev Time 0.00
Received By medwards Date 2022-12-01 Time 15:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-09-20 Cont ID  
Sent By medwards Date 2022-09-20 Time 10:09 Rev Time 0.00
Received By medwards Date 2022-09-20 Time 10:09 Sent To  
Notes
2022-09-20 10:30:282ND REVIEW FMC
 PERMIT: 22070105
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-01SHOWS A 1ST FLOOR CABANA AND A GARAGE WITH
 A GUEST SUITE ON THE 2ND FLOOR. THE EQUIPMENT SIZING
 CALCULATIONS ARE FOR THE EXERCISE AHU AND THE MAIN AHU.
 THE MECHANICAL DRAWING SUBMITTED DOES NOT SHOW THE
 EXERCISE ROOM. SHEET A-02 SHOWS 2 GARAGE DOORS. PLEASE
 PROVIDE ACCURATE MECHANICAL DRAWINGS. FBC 107.3.5
  
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-07-22 Cont ID  
Sent By medwards Date 2022-07-22 Time 13:05 Rev Time 0.00
Received By medwards Date 2022-07-22 Time 13:05 Sent To  
Notes
2022-07-22 13:06:46NO MECHANICAL SCOPE OF WORK OR DRAWINGS. PROVIDE A
 COMPLETE MECHANICAL SCOPE OF WORK INCLUDING DRAWINGS.
 FBC 107.2.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status N Date 2022-08-05 Cont ID  
Sent By jgomez Date 2022-08-05 Time 18:31 Rev Time 0.00
Received By jgomez Date 2022-08-05 Time 18:30 Sent To  
Notes
2022-08-05 18:33:09GARAGE IS COMPLETELY LOCATED IN FLOOD ZONE X.
 MAIN HOUSE IS LOCATED IN FLOOD ZONE AE (EL. 6).

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-09-20 Cont ID  
Sent By rwbrown Date 2022-09-20 Time 07:20 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2022-07-25 Cont ID  
Sent By rwbrown Date 2022-07-25 Time 07:10 Rev Time 0.00
Received By rwbrown Date 2022-07-25 Time 07:10 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status N Date 2023-01-12 Cont ID  
Sent By jgomez Date 2023-01-12 Time 16:14 Rev Time 0.00
Received By jgomez Date 2023-01-12 Time 16:13 Sent To  
Notes
2023-01-12 16:15:50(1) NEED TO PROVIDE PRODUCT APPROVALS FOR:
 (A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY
 IS GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN
 SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED.
 (B)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
 (C)ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS LISTED
 ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED.
 (D)SLOPED ROOF UNDERLAYMENT.
  
 (2)DESIGNER OF RECORD TO REVIEW AND APPROVE ALL PRODUCT
 APPROVALS.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2022-12-28 Cont ID  
Sent By jgomez Date 2022-12-28 Time 13:43 Rev Time 0.00
Received By jgomez Date 2022-12-28 Time 13:42 Sent To  
Notes
2022-12-28 13:43:46ROOFING REVIEW:
  
 1- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 ORIGINAL COMMENT:
 A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS
 GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN
 SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED.
  
 RESPONSE:
 THERE ARE TWO DIFFERENT PRODUCT APPROVALS UPLOADED IN
 THE SAME PDF FILE. ONE IS CERTAINTEED FLORIDA PRODUCT
 APPROVAL FL2533-R28 AND THE OTHER ONE IS CERTAINTEED
 NOA 17-1003.15. IMPORTANT NEED TO SUBMIT ONLY ONE
 PRODUCT APPROVAL TO AVOID CONFLICTS.
  
 NOTE:
 EITHER PRODUCT APPROVAL REQUIRES SIGNED AND SEALED RAS
 117 CALCULATIONS BECAUSE THE SELECTED ASSEMBLIES DON'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES. THE
 MAXIMUM DESIGN PRESSURES (MDP) ON SELECTED ASSEMBLY
 W-77 CERTAINTEED FLORIDA PRODUCT APPROVAL FL2533-R28 IS
 -60PSF. AND THE DESIGN PRESSURES ON CERTAINTEED NOA
 17-1003.15 WERE NO IDENTIFIED BECAUSE NO ASSEMBLY WAS
 SELECTED. NEVERTHELESS NONE OF THE ASSEMBLIES ON NOA
 SUBMITTED MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES.
 NOTE: WHEN SELECTING AN ASSEMBLY MAKE SURE SELECTED
 ASSEMBLY IS NOT LIMITED BY GENERAL LIMITATION #9
 BECAUSE THIS LIMITATION DOESN'T ALLOW NAIL ENHANCEMENT.
 SEE GENERAL LIMITATION #9 ON LAST PAGE OF NOA.
 SEC.107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 B)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 THERE ARE TWO DIFFERENT PRODUCT APPROVALS UPLOADED IN
 THE SAME PDF FILE. ONE IS CERAMICA VEREA FLORIDA
 PRODUCT APPROVAL FL17152-R4 AND THE OTHER ONE IS TEJAS
 VEREA NOA 20-0902.03. IMPORTANT NEED TO SUBMIT ONLY ONE
 PRODUCT APPROVAL AND CLEARLY MARK FASTENING METHOD TO
 AVOID CONFLICTS
 NOTE: FLORIDA PRODUCT APPROVAL FL17152-R4 IS NOT MARKED
 SHOWING THE FASTENING METHOD. NOA 20-0902.03 IS MARKED
 WITH AH-160 ADHESIVE ON PAGE 5 OF 9. THIS FASTENING
 METHOD IS OK FOR ALL ROOF ZONES BUT ADHESIVE PRODUCT
 APPROVAL SUBMITTED DOESN'T MATCH AH-160 ADHESIVE LISTED
 IN THE NOA. COORDINATE AS REQUIRED TO AVOID MORE
 CONFLICTS/DELAYS. SEC.107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 C)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS
 LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED.
  
 RESPONSE:
 COORDINATE WITH ITEM #9(C) ABOVE TO AVOID MORE
 CONFLICTS/DELAYS. SEC.107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 D) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY
 MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC.
 R905.3.7.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 FLORIDA PRODUCT APPROVAL FL5374-R6 SUBMITTED IS OK.
 NOTE: COORDINATE ROOF TILE ADHESIVE WITH ITEM #9(C)
 ABOVE TO AVOID MORE CONFLICTS/DELAYS. SEC.107.2.1 CITY
 AMENDMENTS.
  
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2022-10-05 Cont ID  
Sent By jgomez Date 2022-10-05 Time 16:41 Rev Time 0.00
Received By jgomez Date 2022-10-05 Time 16:40 Sent To  
Notes
2022-10-05 16:40:54ROOFING REVIEW:
  
 1- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 ORIGINAL COMMENT:
 A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS
 GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN
 SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED.
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES "GC REVISED FLAT
 ROOF SUBMITTAL. NEW SUBMITTAL ATTACHED.".
 NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW.
  
 ORIGINAL COMMENT:
 B)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES "ROOF TILE AND PADDY
 SIZE ADDED. NEW SUBMITTAL ATTACHED.".
 NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW.
  
 ORIGINAL COMMENT:
 C)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS
 LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED.
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES "ROOF TILE ADHESIVE
 PRODUCT APPROVAL ATTACHED.".
 NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW.
  
 ORIGINAL COMMENT:
 D) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY
 MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC.
 R905.3.7.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 ARCHITECT'S RESPONSE LETTER STATES "HIP AND RIDGE
 PRODUCT APPROVAL ATTACHED.".
 NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW.
  
 ORIGINAL COMMENT:
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 RESPONSE:
 NOT ADDRESSED.
 NOTE: THIS COMMENT APPLIES TO ALL PRODUCT APPROVALS
 SUBMITTED,
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-08-05 Cont ID  
Sent By jgomez Date 2022-08-05 Time 17:09 Rev Time 0.00
Received By jgomez Date 2022-08-05 Time 17:08 Sent To  
Notes
2022-08-05 17:09:30ROOFING REVIEW:
  
 1- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A) FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY
 IS GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN
 SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED.
  
 B) ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
  
 C)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS
 LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED.
  
 D) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY
 MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC.
 R905.3.7.1 FBC-RESIDENTIAL.
  
 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2023-02-01 Cont ID  
Sent By mpeterso Date 2023-02-01 Time 15:17 Rev Time 0.00
Received By mpeterso Date 2023-02-01 Time 15:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2023-01-12 Cont ID  
Sent By jgomez Date 2023-01-12 Time 16:18 Rev Time 0.00
Received By jgomez Date 2023-01-12 Time 16:16 Sent To  
Notes
2023-01-12 16:18:51SIGNATURE REVIEW:
  
 1- ALL STRUCTURAL DRAWINGS SUBMITTED HAVE A COPY OF THE
 ENGINEER'S DIGITAL SIGNATURE. DIGITAL SIGNATURES ARE
 NOT ALLOWED TO BE PRINTED. ALL DOCUMENTS PREPARED BY A
 LICENSED ENGINEER NEED TO HAVE THE ORIGINAL VERIFIABLE
 DIGITAL SIGNATURE OF THE ENGINEER OF RECORD AS REQUIRED
 BY SEC. 61G15-23.004 FAC AND CHAPTER 471 F.S.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-12-28 Cont ID  
Sent By jgomez Date 2022-12-28 Time 14:09 Rev Time 0.00
Received By jgomez Date 2022-12-28 Time 13:55 Sent To  
Notes
2022-12-28 14:10:01SIGNATURE REVIEW:
  
 1- ALL STRUCTURAL DRAWINGS SUBMITTED HAVE A COPY OF THE
 ENGINEER'S DIGITAL SIGNATURE. DIGITAL SIGNATURES ARE
 NOT ALLOWED TO BE PRINTED. ALL DOCUMENTS PREPARED BY A
 LICENSED ENGINEER NEED TO HAVE THE ORIGINAL VERIFIABLE
 DIGITAL SIGNATURE OF THE ENGINEER OF RECORD AS REQUIRED
 BY SEC. 61G15-23.004 FAC AND CHAPTER 471 F.S.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-10-05 Cont ID  
Sent By mpeterso Date 2022-10-05 Time 10:12 Rev Time 0.00
Received By mpeterso Date 2022-10-05 Time 10:12 Sent To  
Notes
2022-12-01 15:45:36MECHANICAL DIGITAL SIGNATURE APPROVED ME
2022-10-05 10:20:20SIGNATURE REVIEW FAILED
  
 (2) PLANS SUBMITTED WITH TAVARES ENGINEERING TITLE
 BLOCK, DOES NOT DETAIL THE REQUIRED, VERIFIABLE DIGITAL
 SIGNATURE
  
 FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF
 RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 DIGITALLY SEALED AND SIGNED.
  
 PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS
 FOLLOWING PROJECTDOX INSTRUCTIONS
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
2022-09-20 10:31:09MECHANICAL DIGITAL SIGNATURE APPROVED ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-08-05 Cont ID  
Sent By jgomez Date 2022-08-05 Time 15:59 Rev Time 0.00
Received By jgomez Date 2022-08-05 Time 15:58 Sent To  
Notes
2022-08-05 15:59:34SIGNATURE REVIEW:
  
 1- ALL STRUCTURAL DRAWINGS SUBMITTED HAVE A COPY OF A
 DIGITAL SIGNATURE. DIGITAL SIGNATURES ARE NOT ALLOWED
 TO BE PRINTED. ALL DOCUMENTS PREPARED BY A LICENSED
 ENGINEER NEED TO HAVE THE ORIGINAL VERIFIABLE DIGITAL
 SIGNATURE OF THE ENGINEER OF RECORD AS REQUIRED BY SEC.
 61G15-23.004 FAC AND CHAPTER 471 F.S.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2022-12-08 Cont ID  
Sent By amhamilt Date 2022-12-08 Time 10:16 Rev Time 0.00
Received By amhamilt Date 2022-12-08 Time 10:16 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-09-23 Cont ID  
Sent By afowlkes Date 2022-09-23 Time 15:15 Rev Time 0.00
Received By afowlkes Date 2022-09-23 Time 15:15 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-08-02 Cont ID  
Sent By afowlkes Date 2022-08-02 Time 14:29 Rev Time 0.00
Received By afowlkes Date 2022-08-02 Time 14:29 Sent To  
Notes
2022-08-02 14:32:2408/02/22 FAILED
  
 PLEASE PROVIDE A DETAILED SCOPE OF WORK, AS WELL AS AN
 EXISTING VS COMPLETED FLOORPLAN FOR THE GARAGE AND
 GUEST HOUSE.
  
 ALEXANDER FOWLKES
 [email protected]
 5618221431