| Plan Review Stops For Permit 22070105 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-07-21 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-07-21 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-07-21 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2022-07-21 09:27:29 | WORK TO BE DONE ON THE NORTH BUILDING WITH THE ADDRESS | | | OF 213 MARLBOROUGH RD, UPDATED THE PERMITS DOCS TO | | | REFLECT THE CORRECT ADDRESS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2023-01-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-01-12 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-01-12 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2023-01-12 16:13:37 | BUILDING REVIEW APPROVED WITH PROVISO | | | (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO | | | INSTALLATION & INSPECTION TO AVOID CONFLICTS/DELAYS): | | | | | | (1)SHEET A-01: | | | (A)PARAPET DETAIL ON SHEET A-01 IS INCOMPLETE. MISSING | | | CONNECTOR FOR 2X4 SILL PLATE TO THE ROOF RAFTERS AND | | | ATTACHMENT OF THE DOUBLE 2X4 TOP PLATE TO THE STUDS. | | | (B)REVISE SIZE OF EMERGENCY OVERFLOW SCUPPERS. SEC. | | | R903.4.1 FBC-RESIDENTIAL AND SEC. 1108.3 FBC-PLUMBING | | | (OPENING WIDTH EQUAL TO THE CIRCUMFERENCE OF THE ROOF | | | DRAIN REQUIRED FOR THE AREA SERVED). | | | | | | (2)PRODUCT APPROVALS DEFERRED SUBMITTAL: PROVIDE | | | PRODUCT APPROVAL FOR: | | | (A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY | | | IS GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T | | | MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN | | | SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED. | | | (B)DOUBLE INSWING FRENCH DOORS AS SHOWN ON THE SECOND | | | FLOOR. | | | (C)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE | | | USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS | | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC | | | R301.2.1 FBC-RESIDENTIAL. | | | (D)ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS LISTED | | | ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED. | | | (E)SLOPED ROOF UNDERLAYMENT. | | | (3)DESIGNER OF RECORD TO REVIEW AND APPROVE ALL PRODUCT | | | APPROVALS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-12-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-12-28 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-12-28 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2022-12-28 13:42:04 | RESIDENTIAL (R3) REVISION, ADDITION/ALTERATION THIRD | | | BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PRMIT #22070105 | | | 213 MARLBOROUGH RD | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES APPLY (NOTE: FEES DON'T | | | APPLY TO PRODUCT APPROVAL SUBMITTAL, EXCEPT FOR PRODUCT | | | APPROVALS ALREADY REVIEWED/APPROVED). | | | | | | ***IMPORTANT****CONTRACTOR TO ADVICE IF PROVISO OPTION | | | IS PREFERRED AT THIS TIME OR IF RE-SUBMITTING REQUIRED | | | INFORMATION BEFORE PERMIT ISSUANCE. | | | | | | | | | 1-6 OK. | | | | | | ORIGINAL COMMENT: | | | 7- PROVIDE COMPLETE FRAMING PLANS, SECTIONS AND | | | SPECIFICATIONS FOR RE-CONSTRUCTION OF WOOD CORNICE & | | | BARREL TILE ROOF SHOWN ON PLANS FOR FIRST FLOOR. | | | SPECIFY ALL FRAMING MEMBERS AND CONNECTORS, ETC. SEC. | | | R301.2.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | PARAPET DETAIL ON SHEET A-01 IS INCOMPLETE. IT DOESN'T | | | SPECIFY ALL FRAMING MEMBERS AND ALL CONNECTORS FOR | | | PARAPET WALL. NEED TO PROVIDE THIS INFORMATION. | | | | | | ORIGINAL COMMENT: | | | 8- CLARIFY/REVISE SIZE OF EMERGENCY OVERFLOW SCUPPERS | | | SPECIFIED ON PLANS. SEC. R903.4.1 FBC-RESIDENTIAL. | | | NOTE: 2" EMERGENCY OVERFLOW SCUPPER DOESN'T COMPLY. | | | | | | RESPONSE: | | | EMERGENCY OVERFLOW SCUPPER SIZE (4"H X 2"W) DOESN'T | | | COMPLY. SEE SEC. 1108.3 FBC-PLUMBING AS REQUIRED BY | | | SEC. R903.4.1 FBC-RESIDENTIAL AND REVISE SIZE. | | | | | | 9- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | ORIGINAL COMMENT: | | | A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS | | | GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T | | | MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN | | | SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | RESPONSE: | | | THERE ARE TWO DIFFERENT PRODUCT APPROVALS UPLOADED IN | | | THE SAME PDF FILE. ONE IS CERTAINTEED FLORIDA PRODUCT | | | APPROVAL FL2533-R28 AND THE OTHER ONE IS CERTAINTEED | | | NOA 17-1003.15. IMPORTANT NEED TO SUBMIT ONLY ONE | | | PRODUCT APPROVAL TO AVOID CONFLICTS. | | | | | | NOTE: | | | EITHER PRODUCT APPROVAL REQUIRES SIGNED AND SEALED RAS | | | 117 CALCULATIONS BECAUSE THE SELECTED ASSEMBLIES DON'T | | | MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES. THE | | | MAXIMUM DESIGN PRESSURES (MDP) ON SELECTED ASSEMBLY | | | W-77 CERTAINTEED FLORIDA PRODUCT APPROVAL FL2533-R28 IS | | | -60PSF. AND THE DESIGN PRESSURES ON CERTAINTEED NOA | | | 17-1003.15 WERE NO IDENTIFIED BECAUSE NO ASSEMBLY WAS | | | SELECTED. NEVERTHELESS NONE OF THE ASSEMBLIES ON NOA | | | SUBMITTED MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES. | | | NOTE: WHEN SELECTING AN ASSEMBLY MAKE SURE SELECTED | | | ASSEMBLY IS NOT LIMITED BY GENERAL LIMITATION #9 | | | BECAUSE THIS LIMITATION DOESN'T ALLOW NAIL ENHANCEMENT. | | | SEE GENERAL LIMITATION #9 ON LAST PAGE OF NOA. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | PREVIOUS COMMENT: | | | B) ARCHITECT'S RESPONSE LETTER STATES "GC REVISED | | | OUTSWING FRENCH DOOR SUBMITTAL. NEW SUBMITTAL | | | ATTACHED.". | | | NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW. | | | NOTE: NEED PRODUCT APPROVAL FOR INSWING FRENCH DOORS AS | | | SHOWN ON THE SECOND FLOOR. CHECK DESIGN PRESSURES | | | SPECIFIED ON PLANS. | | | | | | RESPONSE: | | | PRODUCT APPROVAL FOR SINGLE "OUTSWING" DOOR WAS | | | SUBMITTED BUT PRODUCT APPROVAL FOR DOUBLE INSWING DOORS | | | WAS NOT SUBMITTED. | | | | | | ORIGINAL COMMENT: | | | C)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE | | | USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS | | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC | | | R301.2.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | THERE ARE TWO DIFFERENT PRODUCT APPROVALS UPLOADED IN | | | THE SAME PDF FILE. ONE IS CERAMICA VEREA FLORIDA | | | PRODUCT APPROVAL FL17152-R4 AND THE OTHER ONE IS TEJAS | | | VEREA NOA 20-0902.03. IMPORTANT NEED TO SUBMIT ONLY ONE | | | PRODUCT APPROVAL AND CLEARLY MARK FASTENING METHOD TO | | | AVOID CONFLICTS | | | NOTE: FLORIDA PRODUCT APPROVAL FL17152-R4 IS NOT MARKED | | | SHOWING THE FASTENING METHOD. NOA 20-0902.03 IS MARKED | | | WITH AH-160 ADHESIVE ON PAGE 5 OF 9. THIS FASTENING | | | METHOD IS OK FOR ALL ROOF ZONES BUT ADHESIVE PRODUCT | | | APPROVAL SUBMITTED DOESN'T MATCH AH-160 ADHESIVE LISTED | | | IN THE NOA. COORDINATE AS REQUIRED TO AVOID MORE | | | CONFLICTS/DELAYS. SEC.107.2.1 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | D)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS | | | LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED. | | | | | | RESPONSE: | | | COORDINATE WITH ITEM #9(C) ABOVE TO AVOID MORE | | | CONFLICTS/DELAYS. SEC.107.2.1 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | E) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY | | | MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC. | | | R905.3.7.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | FLORIDA PRODUCT APPROVAL FL5374-R6 SUBMITTED IS OK. | | | NOTE: COORDINATE ROOF TILE ADHESIVE WITH ITEM #9(C) | | | ABOVE TO AVOID MORE CONFLICTS/DELAYS. SEC.107.2.1 CITY | | | AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | 10- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | NOT ADDRESSED. | | | NOTE: THIS COMMENT APPLIES TO ALL PRODUCT APPROVALS | | | SUBMITTED, INCLUDING ONES SUBMITTED EARLIER. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-10-05 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-10-04 |
Time |
18:22 |
Sent To |
|
|
| Notes |
| 2022-10-05 16:40:07 | RESIDENTIAL (R3) REVISION, ADDITION/ALTERATION SECOND | | | BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PRMIT #22070105 | | | 213 MARLBOROUGH RD | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. | | | ***IMPORTANT****CONTRACTOR TO ADVICE IF PROVISO OPTION | | | IS PREFERRED AT THIS TIME OR IF RE-SUBMITTING REQUIRED | | | INFORMATION BEFORE PERMIT ISSUANCE. | | | | | | | | | 1- OK. | | | 2- OK. | | | 3- OK. | | | 4- OK. | | | | | | ORIGINAL COMMENT: | | | 5- GUARDRAILS: DESIGNER OF RECORD NEEDS TO PROVIDE THE | | | DETAILS AND SPECIFICATIONS FOR THE CONSTRUCTION OF THE | | | BALCONY GUARDRAILS AS REQUIRED BY TABLE R301.5, SEC. | | | AND SEC. R312.1 FBC-RESIDENTIAL. | | | NOTE: SUBSEQUENT SHOP DRAWINGS ARE TO CONFIRM THAT | | | DESIGN DETAILS AND SPECIFICATIONS ARE MET. | | | | | | RESPONSE: | | | PARTIALLY DONE. NO SPECS FOR PICKETS SPACING. ALSO, | | | GUARDRAIL NOTE ON SHEET A-03 SAYS "SEE STRUCTURAL DWGS | | | FOR CONNECTION DETAILS (TYP)". INFORMATION WAS NOT | | | PROVIDED EITHER. | | | | | | 6- ARCHITECT IS SPECIFYING R-30 CLOSED CELL SPRAY FOAM | | | CEILING INSULATION. PROVIDE ICC EVALUATION REPORT FOR | | | THE ICYNENE R-30 INSULATION TO VERIFY COMPLIANCE WITH | | | SEC. R316 FBC-RESIDENTIAL. | | | NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN | | | WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | RESPONSE: | | | NO SUBMITTED. | | | | | | ORIGINAL COMMENT: | | | 7- PROVIDE COMPLETE FRAMING PLANS, SECTIONS AND | | | SPECIFICATIONS FOR RE-CONSTRUCTION OF WOOD CORNICE & | | | BARREL TILE ROOF SHOWN ON PLANS FOR FIRST FLOOR. | | | SPECIFY ALL FRAMING MEMBERS AND CONNECTORS, ETC. SEC. | | | R301.2.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | PARAPET DETAIL ON SHEET A-01 IS INCOMPLETE. IT DOESN'T | | | SPECIFY ALL THE FRAMING MEMBERS AND CONNECTORS FOR | | | PARAPET WALL. NEED TO PROVIDE THIS INFORMATION. | | | | | | ORIGINAL COMMENT: | | | 8- CLARIFY/REVISE SIZE OF EMERGENCY OVERFLOW SCUPPERS | | | SPECIFIED ON PLANS. SEC. R903.4.1 FBC-RESIDENTIAL. | | | NOTE: 2" EMERGENCY OVERFLOW SCUPPER DOESN'T COMPLY. | | | | | | RESPONSE: | | | EMERGENCY OVERFLOW SCUPPER SIZE (4"H X 2"W) DOESN'T | | | COMPLY. SEE SEC. 1108.3 FBC-PLUMBING AS REQUIRED BY | | | SEC. R903.4.1 FBC-RESIDENTIAL AND REVISE SIZE. | | | | | | | | | 9- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | ORIGINAL COMMENT: | | | A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS | | | GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T | | | MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN | | | SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER STATES "GC REVISED FLAT | | | ROOF SUBMITTAL. NEW SUBMITTAL ATTACHED.". | | | NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW. | | | | | | ORIGINAL COMMENT: | | | B)SINGLE OUTSWING FRENCH DOOR FL34006 SUBMITTED: | | | INSTALLATION INSTRUCTIONS DRAWING W17-108 SUBMITTED | | | DON'T MATCH DRAWING HIGHLIGHTED ON THE FLORIDA PRODUCT | | | APPROVAL COVER PAGE. REVISE AS REQUIRED TO MATCH. | | | NOTE: PLEASE UPLOAD THE FLORIDA PRODUCT APPROVAL COVER | | | PAGE AND CORRESPONDING INSTALLATION DRAWINGS ON THE | | | SAME PDF FILE. DO NOT UPLOAD IN SEPARATE FILES. | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER STATES "GC REVISED OUTSWING | | | FRENCH DOOR SUBMITTAL. NEW SUBMITTAL ATTACHED.". | | | NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW. | | | NOTE: NEED PRODUCT APPROVAL FOR INSWING FRENCH DOORS AS | | | SHOWN ON THE SECOND FLOOR. CHECK DESIGN PRESSURES | | | SPECIFIED ON PLANS. | | | | | | ORIGINAL COMMENT: | | | C)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE | | | USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS | | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC | | | R301.2.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER STATES "ROOF TILE AND PADDY | | | SIZE ADDED. NEW SUBMITTAL ATTACHED.". | | | NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW. | | | | | | ORIGINAL COMMENT: | | | D)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS | | | LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED. | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER STATES "ROOF TILE ADHESIVE | | | PRODUCT APPROVAL ATTACHED.". | | | NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW. | | | | | | ORIGINAL COMMENT: | | | E) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY | | | MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC. | | | R905.3.7.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER STATES "HIP AND RIDGE | | | PRODUCT APPROVAL ATTACHED.". | | | NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW. | | | | | | ORIGINAL COMMENT: | | | 10- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | NOT ADDRESSED. | | | NOTE: THIS COMMENT APPLIES TO ALL PRODUCT APPROVALS | | | SUBMITTED, INCLUDING ONES SUBMITTED EARLIER. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-08-05 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-08-05 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2022-08-05 18:30:16 | RESIDENTIAL (R3) REVISION, ADDITION/ALTERATION BUILDING | | | REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22070105 | | | 213 MARLBOROUGH RD | | | | | | NOTE: | | | CHANGE OF OCCUPANCY SEC. 605 AND SEC. 1001.2.1, SEC. | | | 604 AND SEC. 901.2, SEC. 801.3 FBC-EXISTING BUILDING. | | | ALL NEW WORK SHALL COMPLY WITH THE MATERIALS AND | | | METHODS REQUIREMENTS IN THE FLORIDA BUILDING CODE. | | | | | | NOTE: | | | LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING BUILDING. | | | SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 | | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | | | | | | NOTE: THE FOLLOWING COMMENTS ARE BASED ON PLANS | | | SUBMITTED UNDER MAIN HOUSE REVISION #22070103. WHEN | | | ADDRESSING THE COMMENTS UNDER THIS PERMIT FOR THE | | | DETACHED GARAGE, PLEASE SUBMIT ONLY THE DRAWINGS | | | RELATED TO THE DETACHED GARAGE TO AVOID | | | CONFLICTS/DELAYS. | | | | | | 1- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW BASED ON ALL SCOPE OF WORK TO BE DONE ON THE | | | DETACHED GARAGE (SHORING, DEMOLITION AND COMPLETE | | | RENOVATION). VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. UPDATE VALUATION TO INCLUDE ALL COSTS. | | | PROVIDE COMPLETE COST BREAKDOWN INCLUDING DESIGN | | | PROFESSIONAL FEES. | | | | | | 2- SHEET S-000: | | | ENGINEER OF RECORD TO REVISE END ZONE DISTANCE "A" | | | SPECIFIED FOR THE DETACHED GARAGE. THE MINIMUM | | | DIMENSION IS 4'-0" NOT 3'-0" AS REQUIRED BY NOTE "A" ON | | | FIGURE R301.2(7) FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | | | 3- CLARIFY/REVISE SIZE SECOND FLOOR ENTRY DOOR (E2). | | | EXTERIOR DOOR SCHEDULE ON SHEET A-09 SHOWS DOOR E2 AS | | | 36" X 96" INSWING FRENCH DOOR, BUT | | | SECOND FLOOR PLAN ON SHEET A-02.1 CALL FOR 2'-10" DOOR | | | OPENING. REVISE AS REQUIRED TO MATCH. NEED TO VERIFY | | | ENTRY DOOR COMPLIANCE WITH EGRESS SEC. R311.2 | | | FBC-RESIDENTIAL. | | | | | | 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE | | | RECONSTRUCTION OF THE STAIRWAY SHOWING COMPLIANCE WITH | | | SEC. R311.7 FBC-RESIDENTIAL. | | | PROVIDE SPECS FOR STAIRWAY CONSTRUCTION AND SHOW | | | HANDRAIL LOCATION AND HEIGHT, RISER AND TREADS | | | DIMENSIONS INCLUDING NOSING. | | | | | | 5- GUARDRAILS: DESIGNER OF RECORD NEEDS TO PROVIDE THE | | | DETAILS AND SPECIFICATIONS FOR THE CONSTRUCTION OF THE | | | BALCONY GUARDRAILS AS REQUIRED BY TABLE R301.5, SEC. | | | AND SEC. R312.1 FBC-RESIDENTIAL. | | | NOTE: SUBSEQUENT SHOP DRAWINGS ARE TO CONFIRM THAT | | | DESIGN DETAILS AND SPECIFICATIONS ARE MET. | | | | | | 6- ARCHITECT IS SPECIFYING R-30 CLOSED CELL SPRAY FOAM | | | CEILING INSULATION. PROVIDE ICC EVALUATION REPORT FOR | | | THE ICYNENE R-30 INSULATION TO VERIFY COMPLIANCE WITH | | | SEC. R316 FBC-RESIDENTIAL. | | | NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN | | | WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | | | 7- PROVIDE COMPLETE FRAMING PLANS, SECTIONS AND | | | SPECIFICATIONS FOR RE-CONSTRUCTION OF WOOD CORNICE & | | | BARREL TILE ROOF SHOWN ON PLANS. SPECIFY ALL FRAMING | | | MEMBERS AND CONNECTORS, ETC. SEC. R301.2.1 | | | FBC-RESIDENTIAL. | | | | | | 8- CLARIFY/REVISE SIZE OF EMERGENCY OVERFLOW SCUPPERS | | | SPECIFIED ON PLANS. SEC. R903.4.1 FBC-RESIDENTIAL. | | | NOTE: 2" EMERGENCY OVERFLOW SCUPPER DOESN'T COMPLY. | | | | | | 9- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS | | | GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T | | | MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN | | | SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | B)SINGLE OUTSWING FRENCH DOOR FL34006 SUBMITTED: | | | INSTALLATION INSTRUCTIONS DRAWING W17-108 SUBMITTED | | | DON'T MATCH DRAWING HIGHLIGHTED ON THE FLORIDA PRODUCT | | | APPROVAL COVER PAGE. REVISE AS REQUIRED TO MATCH. | | | NOTE: PLEASE UPLOAD THE FLORIDA PRODUCT APPROVAL COVER | | | PAGE AND CORRESPONDING INSTALLATION DRAWINGS ON THE | | | SAME PDF FILE. DO NOT UPLOAD IN SEPARATE FILES. | | | | | | C)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE | | | USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS | | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC | | | R301.2.1 FBC-RESIDENTIAL. | | | | | | D)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS | | | LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED. | | | | | | E) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY | | | MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC. | | | R905.3.7.1 FBC-RESIDENTIAL. | | | | | | F)WINDOW MULLIONS NOA 19-0131.11 SUBMITTED. NOTE: NEED | | | TO SPECIFY MULLION SIZE TO VERIFY PRESSURES. SEC. | | | R301.2.1 FBC-RESIDENTIAL. | | | | | | 10- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-05 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-05 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-01 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-01 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2022-08-01 13:05:47 | NO ELECTRIC WORK SHOWN, REVIEWED OR APPROVED. MP |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-12-08 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-12-08 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-12-08 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-10-07 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-10-07 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-10-07 |
Time |
16:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-08-05 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-08-05 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2022-08-05 16:22:33 | NOT ENOUGH INFOMATION PROVIDED. NEED ELEVATIONS AND | | | SITE PLAN. ROOF MATERIAL ETC. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-02-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-02-01 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-02-01 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-01-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-01-12 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-01-12 |
Time |
14:45 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-12-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-12-28 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-11-30 |
Time |
15:03 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-10-11 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-10-11 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-09-19 |
Time |
08:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-08-05 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-07-21 |
Time |
08:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2023-01-31 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-01-31 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-01-12 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2023-01-20 15:37:21 | RECEIPT MU-2023-002351 - $22.46 PAID | | 2023-01-12 16:40:52 | 1/12/23 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2022-12-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-12-28 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-12-28 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2022-12-28 13:42:28 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-10-05 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-10-04 |
Time |
18:34 |
Sent To |
|
|
| Notes |
| 2022-10-05 10:51:44 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-08-05 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-08-05 |
Time |
17:14 |
Sent To |
|
|
| Notes |
| 2022-08-05 17:15:08 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-12-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-01 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-01 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-20 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-20 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2022-09-20 10:30:28 | 2ND REVIEW FMC | | | PERMIT: 22070105 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A-01SHOWS A 1ST FLOOR CABANA AND A GARAGE WITH | | | A GUEST SUITE ON THE 2ND FLOOR. THE EQUIPMENT SIZING | | | CALCULATIONS ARE FOR THE EXERCISE AHU AND THE MAIN AHU. | | | THE MECHANICAL DRAWING SUBMITTED DOES NOT SHOW THE | | | EXERCISE ROOM. SHEET A-02 SHOWS 2 GARAGE DOORS. PLEASE | | | PROVIDE ACCURATE MECHANICAL DRAWINGS. FBC 107.3.5 | | | | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-22 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-22 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2022-07-22 13:06:46 | NO MECHANICAL SCOPE OF WORK OR DRAWINGS. PROVIDE A | | | COMPLETE MECHANICAL SCOPE OF WORK INCLUDING DRAWINGS. | | | FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
N |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-08-05 |
Time |
18:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-08-05 |
Time |
18:30 |
Sent To |
|
|
| Notes |
| 2022-08-05 18:33:09 | GARAGE IS COMPLETELY LOCATED IN FLOOD ZONE X. | | | MAIN HOUSE IS LOCATED IN FLOOD ZONE AE (EL. 6). |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-09-20 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-25 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-25 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-07-25 |
Time |
07:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
N |
Date |
2023-01-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-01-12 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-01-12 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2023-01-12 16:15:50 | (1) NEED TO PROVIDE PRODUCT APPROVALS FOR: | | | (A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY | | | IS GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T | | | MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN | | | SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED. | | | (B)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE | | | USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS | | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC | | | R301.2.1 FBC-RESIDENTIAL. | | | (C)ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS LISTED | | | ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED. | | | (D)SLOPED ROOF UNDERLAYMENT. | | | | | | (2)DESIGNER OF RECORD TO REVIEW AND APPROVE ALL PRODUCT | | | APPROVALS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2022-12-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-12-28 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-12-28 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2022-12-28 13:43:46 | ROOFING REVIEW: | | | | | | 1- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | ORIGINAL COMMENT: | | | A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS | | | GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T | | | MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN | | | SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | RESPONSE: | | | THERE ARE TWO DIFFERENT PRODUCT APPROVALS UPLOADED IN | | | THE SAME PDF FILE. ONE IS CERTAINTEED FLORIDA PRODUCT | | | APPROVAL FL2533-R28 AND THE OTHER ONE IS CERTAINTEED | | | NOA 17-1003.15. IMPORTANT NEED TO SUBMIT ONLY ONE | | | PRODUCT APPROVAL TO AVOID CONFLICTS. | | | | | | NOTE: | | | EITHER PRODUCT APPROVAL REQUIRES SIGNED AND SEALED RAS | | | 117 CALCULATIONS BECAUSE THE SELECTED ASSEMBLIES DON'T | | | MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES. THE | | | MAXIMUM DESIGN PRESSURES (MDP) ON SELECTED ASSEMBLY | | | W-77 CERTAINTEED FLORIDA PRODUCT APPROVAL FL2533-R28 IS | | | -60PSF. AND THE DESIGN PRESSURES ON CERTAINTEED NOA | | | 17-1003.15 WERE NO IDENTIFIED BECAUSE NO ASSEMBLY WAS | | | SELECTED. NEVERTHELESS NONE OF THE ASSEMBLIES ON NOA | | | SUBMITTED MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES. | | | NOTE: WHEN SELECTING AN ASSEMBLY MAKE SURE SELECTED | | | ASSEMBLY IS NOT LIMITED BY GENERAL LIMITATION #9 | | | BECAUSE THIS LIMITATION DOESN'T ALLOW NAIL ENHANCEMENT. | | | SEE GENERAL LIMITATION #9 ON LAST PAGE OF NOA. | | | SEC.107.2.1 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | B)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE | | | USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS | | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC | | | R301.2.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | THERE ARE TWO DIFFERENT PRODUCT APPROVALS UPLOADED IN | | | THE SAME PDF FILE. ONE IS CERAMICA VEREA FLORIDA | | | PRODUCT APPROVAL FL17152-R4 AND THE OTHER ONE IS TEJAS | | | VEREA NOA 20-0902.03. IMPORTANT NEED TO SUBMIT ONLY ONE | | | PRODUCT APPROVAL AND CLEARLY MARK FASTENING METHOD TO | | | AVOID CONFLICTS | | | NOTE: FLORIDA PRODUCT APPROVAL FL17152-R4 IS NOT MARKED | | | SHOWING THE FASTENING METHOD. NOA 20-0902.03 IS MARKED | | | WITH AH-160 ADHESIVE ON PAGE 5 OF 9. THIS FASTENING | | | METHOD IS OK FOR ALL ROOF ZONES BUT ADHESIVE PRODUCT | | | APPROVAL SUBMITTED DOESN'T MATCH AH-160 ADHESIVE LISTED | | | IN THE NOA. COORDINATE AS REQUIRED TO AVOID MORE | | | CONFLICTS/DELAYS. SEC.107.2.1 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | C)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS | | | LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED. | | | | | | RESPONSE: | | | COORDINATE WITH ITEM #9(C) ABOVE TO AVOID MORE | | | CONFLICTS/DELAYS. SEC.107.2.1 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | D) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY | | | MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC. | | | R905.3.7.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | FLORIDA PRODUCT APPROVAL FL5374-R6 SUBMITTED IS OK. | | | NOTE: COORDINATE ROOF TILE ADHESIVE WITH ITEM #9(C) | | | ABOVE TO AVOID MORE CONFLICTS/DELAYS. SEC.107.2.1 CITY | | | AMENDMENTS. | | | | | | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-10-05 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-10-05 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2022-10-05 16:40:54 | ROOFING REVIEW: | | | | | | 1- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | ORIGINAL COMMENT: | | | A)FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS | | | GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T | | | MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN | | | SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER STATES "GC REVISED FLAT | | | ROOF SUBMITTAL. NEW SUBMITTAL ATTACHED.". | | | NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW. | | | | | | ORIGINAL COMMENT: | | | B)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE | | | USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS | | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC | | | R301.2.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER STATES "ROOF TILE AND PADDY | | | SIZE ADDED. NEW SUBMITTAL ATTACHED.". | | | NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW. | | | | | | ORIGINAL COMMENT: | | | C)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS | | | LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED. | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER STATES "ROOF TILE ADHESIVE | | | PRODUCT APPROVAL ATTACHED.". | | | NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW. | | | | | | ORIGINAL COMMENT: | | | D) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY | | | MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC. | | | R905.3.7.1 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | ARCHITECT'S RESPONSE LETTER STATES "HIP AND RIDGE | | | PRODUCT APPROVAL ATTACHED.". | | | NOTHING WAS UPLOADED TO PROJECTDOX FOR REVIEW. | | | | | | ORIGINAL COMMENT: | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | NOT ADDRESSED. | | | NOTE: THIS COMMENT APPLIES TO ALL PRODUCT APPROVALS | | | SUBMITTED, | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-08-05 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-08-05 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2022-08-05 17:09:30 | ROOFING REVIEW: | | | | | | 1- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A) FLAT ROOF AND CLEARLY MARK/IDENTIFY WHICH ASSEMBLY | | | IS GOING TO BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T | | | MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN | | | SIGNED AND SEALED RAS 117 CALCULATIONS ARE REQUIRED. | | | | | | B) ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE | | | USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS | | | TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC | | | R301.2.1 FBC-RESIDENTIAL. | | | | | | C)PROVIDE A ROOF TILE ADHESIVE PRODUCT APPROVAL THAT IS | | | LISTED ON THE ROOF TILE PRODUCT APPROVAL SUBMITTED. | | | | | | D) HIP AND RIDGE INSTALLATION TO BE USED. AND, CLEARLY | | | MARK ON PRODUCT APPROVAL ATTACHMENT METHOD. SEC. | | | R905.3.7.1 FBC-RESIDENTIAL. | | | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2023-02-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-02-01 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-02-01 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2023-01-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-01-12 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-01-12 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2023-01-12 16:18:51 | SIGNATURE REVIEW: | | | | | | 1- ALL STRUCTURAL DRAWINGS SUBMITTED HAVE A COPY OF THE | | | ENGINEER'S DIGITAL SIGNATURE. DIGITAL SIGNATURES ARE | | | NOT ALLOWED TO BE PRINTED. ALL DOCUMENTS PREPARED BY A | | | LICENSED ENGINEER NEED TO HAVE THE ORIGINAL VERIFIABLE | | | DIGITAL SIGNATURE OF THE ENGINEER OF RECORD AS REQUIRED | | | BY SEC. 61G15-23.004 FAC AND CHAPTER 471 F.S. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-12-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-12-28 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-12-28 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2022-12-28 14:10:01 | SIGNATURE REVIEW: | | | | | | 1- ALL STRUCTURAL DRAWINGS SUBMITTED HAVE A COPY OF THE | | | ENGINEER'S DIGITAL SIGNATURE. DIGITAL SIGNATURES ARE | | | NOT ALLOWED TO BE PRINTED. ALL DOCUMENTS PREPARED BY A | | | LICENSED ENGINEER NEED TO HAVE THE ORIGINAL VERIFIABLE | | | DIGITAL SIGNATURE OF THE ENGINEER OF RECORD AS REQUIRED | | | BY SEC. 61G15-23.004 FAC AND CHAPTER 471 F.S. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-05 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-05 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2022-12-01 15:45:36 | MECHANICAL DIGITAL SIGNATURE APPROVED ME | | 2022-10-05 10:20:20 | SIGNATURE REVIEW FAILED | | | | | | (2) PLANS SUBMITTED WITH TAVARES ENGINEERING TITLE | | | BLOCK, DOES NOT DETAIL THE REQUIRED, VERIFIABLE DIGITAL | | | SIGNATURE | | | | | | FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF | | | RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | DIGITALLY SEALED AND SIGNED. | | | | | | PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS | | | FOLLOWING PROJECTDOX INSTRUCTIONS | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | 2022-09-20 10:31:09 | MECHANICAL DIGITAL SIGNATURE APPROVED ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-08-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-08-05 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-08-05 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2022-08-05 15:59:34 | SIGNATURE REVIEW: | | | | | | 1- ALL STRUCTURAL DRAWINGS SUBMITTED HAVE A COPY OF A | | | DIGITAL SIGNATURE. DIGITAL SIGNATURES ARE NOT ALLOWED | | | TO BE PRINTED. ALL DOCUMENTS PREPARED BY A LICENSED | | | ENGINEER NEED TO HAVE THE ORIGINAL VERIFIABLE DIGITAL | | | SIGNATURE OF THE ENGINEER OF RECORD AS REQUIRED BY SEC. | | | 61G15-23.004 FAC AND CHAPTER 471 F.S. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-12-08 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-12-08 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-12-08 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-09-23 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-09-23 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-09-23 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-02 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-08-02 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-08-02 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2022-08-02 14:32:24 | 08/02/22 FAILED | | | | | | PLEASE PROVIDE A DETAILED SCOPE OF WORK, AS WELL AS AN | | | EXISTING VS COMPLETED FLOORPLAN FOR THE GARAGE AND | | | GUEST HOUSE. | | | | | | ALEXANDER FOWLKES | | | [email protected] | | | 5618221431 |
|
|