Rev No 4 Status P Date 2022-12-22 Cont ID  
Sent By rwbrown Date 2022-12-22 Time 13:08 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2022-12-15 Cont ID  
Sent By ccole Date 2022-12-15 Time 16:06 Rev Time 0.00
Received By ccole Date 2022-12-15 Time 15:57 Sent To  
Notes
2022-12-15 16:07:203RD REVIEW FBC-2020 RES. FUEL GAS
 PERMIT- 22070048
 12/15/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
  
 1) 3RD REQUEST FOR RESPONSE TO COMMENT 1A COPIED BELOW.
 A) GAS RISER: SHOW THE SIZE OF THE MAIN METALLIC SUPPLY
 PIPE FROM THE METER TO THE 1ST TEE, AND THE SIZE OF THE
 BRANCH PIPE SUPPLYING THE MAIN HOUSE APPLIANCES.
 THE NEW RISER SHOWS A TOTAL OF 485,000 BTU FOR THE LOW
 PRESSURE SYSTEM. ASSUMING THE TOTAL DEVELOPED LENGTH OF
 THE SYSTEM DOES NOT EXCEED 20 FT. A MINIMUM 1-1/4 MAIN
 SUPPLY IS REQUIRED.
  
 G2412.3 (401.3) MODIFICATIONS TO EXISTING SYSTEMS.
 IN MODIFYING OR ADDING TO EXISTING PIPING SYSTEMS,
 SIZES SHALL BE MAINTAINED IN ACCORDANCE WITH THIS
 CHAPTER.
 G2412.4 (401.4) ADDITIONAL APPLIANCES.
 WHERE AN ADDITIONAL APPLIANCE IS TO BE SERVED, THE
 EXISTING PIPING SHALL BE CHECKED TO DETERMINE IF IT HAS
 ADEQUATE CAPACITY FOR ALL APPLIANCES SERVED. IF
 INADEQUATE, THE EXISTING SYSTEM SHALL BE ENLARGED AS
 REQUIRED OR SEPARATE PIPING OF ADEQUATE CAPACITY SHALL
 BE PROVIDED.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 CCOLE@WPB
  

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-07-14 Cont ID  
Sent By ccole Date 2022-07-14 Time 14:48 Rev Time 0.00
Received By ccole Date 2022-07-14 Time 12:59 Sent To  
Notes
2022-07-14 14:48:581ST REVIEW FBC-2020 RES. FUEL GAS
 PERMIT- 22070048
 7/8/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER: BASED ON TABLES 402.4(21) FBC FUEL GAS
 THE 17 FT. RUN OF 3/4 -INCH PE IS ADEQUATELY SIZED
 HOWEVER A COMPLETE RISER THAT INCLUDES THE EXISTING GAS
 PIPING AND APPLIANCES HAS NOT BEEN NOT PROVIDED- SEE
 SECS. G2412.3 & G2412.4 COPIED BELOW.
 A) SHOW THE SIZE OF THE MAIN METALLIC SUPPLY PIPE FROM
 THE METER TO THE 1ST TEE, AND THE SIZE OF THE BRANCH
 PIPE SUPPLYING THE MAIN HOUSE APPLIANCES. COMPLETE THE
 RISER AS NOTED ABOVE.
 B) THE PRINTED NAME AND SIGNATURE OF THE CONTRACTOR OR
 QUALIFIER SHALL BE ON THE RISER DRAWING- SEC. 107.2.1
 WPB.
  
 G2412.3 (401.3) MODIFICATIONS TO EXISTING SYSTEMS.
 IN MODIFYING OR ADDING TO EXISTING PIPING SYSTEMS,
 SIZES SHALL BE MAINTAINED IN ACCORDANCE WITH THIS
 CHAPTER.
 G2412.4 (401.4) ADDITIONAL APPLIANCES.
 WHERE AN ADDITIONAL APPLIANCE IS TO BE SERVED, THE
 EXISTING PIPING SHALL BE CHECKED TO DETERMINE IF IT HAS
 ADEQUATE CAPACITY FOR ALL APPLIANCES SERVED. IF
 INADEQUATE, THE EXISTING SYSTEM SHALL BE ENLARGED AS
 REQUIRED OR SEPARATE PIPING OF ADEQUATE CAPACITY SHALL
 BE PROVIDED.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 CCOLE@WPB
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-07-08 Cont ID  
Sent By ccole Date 2022-07-08 Time 07:14 Rev Time 0.00
Received By ccole Date 2022-07-08 Time 06:55 Sent To  
Notes
2022-07-08 07:15:571ST REVIEW FBC-2020 RES. FUEL GAS
 PERMIT- 22070048
 7/8/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) A GAS PLAN REVIEW FOR INSTALLATION OF THE GAS-FIRED
 POOL HEATER WAS NOT PERFORMED UNDER THE MASTER POOL
 PERMIT- 22031603. THE PLUMBING REVIEWER PLACED THE
 FOLLOWING NOTE ON THE GAS REVIEW FOR THE POOL-
 ?GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE, AND A GAS PLAN REVIEW HAS NOT
 BEEN PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND
 PLANS WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT
 REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE PER
 THE WPB AMENDMENTS TO FBC SEC. 107.2.1.?
  
 PLEASE SUBMIT A GAS RISER DRAWING AND A PRODUCT SPEC
 SHEET FOR THE GAS POOL HEATER- SECS. 107.2.1 &
 107.3.5.3 WPB. REFER TO FBC RES. FUEL GAS CHAPTER 24
 AND PROVIDE A COMPLETE RISER DRAWING WITH THE FOLLOWING
 INFORMATION:
 A) DELIVERY PRESSURE AT THE METER.
 B) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 C) TYPES AND SIZES OF PIPING.
 D) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 E) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 F) LOCATIONS OF REGULATORS, SHUTOFF VALVES, DRIP LEGS,
 AND PIPE UNIONS.
 G) OUTLET PRESSURES AT REGULATORS.
 H) LOCATIONS AND TYPES OF PIPE SLEEVES.
 I) PIPE SIZING TABLES
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2022-12-15 Time   Rev Time 0.00
Received By aoliver Date 2022-12-13 Time 06:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-07-14 Time   Rev Time 0.00
Received By lmarchan Date 2022-07-13 Time 15:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-07-08 Time   Rev Time 0.00
Received By cdecoeur Date 2022-07-07 Time 07:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status N Date 2022-12-15 Cont ID  
Sent By ccole Date 2022-12-15 Time 16:06 Rev Time 0.00
Received By ccole Date 2022-12-15 Time 15:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2022-07-14 Cont ID  
Sent By ccole Date 2022-07-14 Time 14:50 Rev Time 0.00
Received By ccole Date 2022-07-14 Time 12:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2022-07-08 Cont ID  
Sent By ccole Date 2022-07-08 Time 07:16 Rev Time 0.00
Received By ccole Date 2022-07-08 Time 06:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-07-08 Cont ID  
Sent By ccole Date 2022-07-08 Time 07:16 Rev Time 0.00
Received By ccole Date 2022-07-08 Time 06:55 Sent To  
Notes
***NONE***