| Plan Review Stops For Permit 22061671 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
P |
Date |
2022-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-24 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-24 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-07-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-27 |
Time |
06:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-27 |
Time |
06:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-24 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-24 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2022-07-24 08:34:45 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FBC B 1006.2, REVISE PLAN TO DECLARE AN OCCUPANCY | | | CLASSIFICATION FOR THE NEW CONFERENCE ROOM, OCCUPANT | | | LOAD FOR THE NEW CONFERENCE ROOM. | | | | | | IT APPEARS THAT ONE MEANS OF EGRESS IS REQUIRED FROM | | | THIS NEW SPACE BUT WITHOUT THIS INFORMATION FROM THE | | | DESIGN PROFESSIONAL THAT CANNOT BE CONFIRMED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-07-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-07-29 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-07-29 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-07-14 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-07-14 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2022-07-14 17:17:31 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | FLOOR OUTLETS AND WALL OUTLETS NEED TO BE INSTALLED PER | | | 210.71 | | | | | | 210.71(B) RECEPTACLE OUTLETS REQUIRED. THE TOTAL NUMBER | | | OF RECEPTACLE OUTLETS, INCLUDING FLOOR OUTLETS AND | | | RECEPTACLE OUTLETS IN FIXED FURNITURE, SHALL NOT BE | | | LESS THAN AS DETERMINED IN (1) AND (2). THESE | | | RECEPTACLE OUTLETS SHALL BE PERMITTED TO BE LOCATED AS | | | DETERMINED BY THE DESIGNER OR BUILDING OWNER. | | | (1) RECEPTACLE OUTLETS IN FIXED WALLS. RECEPTACLE | | | OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH | | | 210.52(A)(1) THROUGH (A)(4). | | | (2) FLOOR RECEPTACLE OUTLETS. A MEETING ROOM THAT IS AT | | | LEAST 3.7 M (12 FT) WIDE AND THAT HAS A FLOOR AREA OF | | | AT LEAST 20 M2 (215 FT2) SHALL HAVE AT LEAST ONE | | | RECEPTACLE OUTLET LOCATED IN THE FLOOR AT A DISTANCE | | | NOT LESS THAN 1.8 M (6 FT) FROM ANY FIXED WALL FOR EACH | | | 20 M2 (215 FT2) OR MAJOR PORTION OF FLOOR SPACE. | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-07-14 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-07-14 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2022-07-14 17:16:03 | VOICE DATA, AND TV AS PER PLAN JLEAHY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-07-27 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-07-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-07-27 09:25:12 | FIRE REVIEW COMMENTS: | | | THE REMOVAL OF WALLS AND/OR CEILINGS WILL REQUIRE AN | | | EVALUATION OF THE LIFE SAFETY SYSTEMS (FIRE ALARM | | | AND/OR FIRE SPRINKLER) TO ENSURE CODE COMPLIANT | | | COVERAGE. | | | ANY CHANGES OR MODIFICATIONS TO THE LIFE SAFETY SYSTEMS | | | (FIRE ALARM AND/OR FIRE SPRINKLER) WILL REQUIRE | | | SEPARATE PERMITS AND SHOP DRAWINGS. | | | THE DOOR HARDWARE WAS NOT INCLUDED ON THE PLAN. ALL | | | DOOR HARDWARE SHALL COMPLY WITH NFPA 101, 7.2.1 | | | ANY CHANGE TO THE INTERIOR FINISHES SHALL COMPLY WITH | | | NFPA 101 10.2 | | | C. WALKER | | | 561-804-4762 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-07-05 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-07-05 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-07-05 10:52:39 | FIRE REVIEW COMMENTS: | | | THE REMOVAL OF WALLS AND OR CEILINGS WILL REQUIRE AN | | | EVALUATION OF THE LIFE SAFETY SYSTEMS (FIRE ALARM AND | | | FIRE SPRINKLER) TO ENSURE CODE COMPLIANT COVERAGE. | | | ANY CHANGES OR MODIFICATIONS TO THE LIFE SAFETY SYSTEM | | | (FIRE ALARM AND FIRE SPRINKLER) WILL REQUIRE SEPARATE | | | PERMITS AND SHOP DRAWINGS. | | | THE DOOR HARDWARE WAS NOT INCLUDED ON THE PLAN. ALL | | | DOOR HARDWARE SHALL COMPLY WITH NFPA 101, 7.2.1 | | | ANY CHANGE TO THE INTERIOR FINISHES SHALL COMPLY WITH | | | NFPA 101, 10.2 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-07-29 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-07-29 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-07-26 |
Time |
12:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-24 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-01 |
Time |
07:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-07-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-27 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-27 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-05 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-05 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2022-07-05 10:30:42 | PROVIDE A MECHANICAL SCOPE OF WORK FOR THIS PROJECT. | | | INCLUDE THE OUTDOOR AIR CALCULATIONS FOR THIS NEWLY | | | CREATED CONFERENCE ROOM. FBC 107.2.1 AND FMC 403.3.1.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-07-28 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-28 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-07-28 |
Time |
07:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-07-05 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-05 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-07-05 |
Time |
11:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-07-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-27 |
Time |
06:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-27 |
Time |
06:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-07-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-24 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-24 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|