Plan Review Details - Permit 22061488
Plan Review Stops For Permit 22061488
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-11-08 Cont ID  
Sent By cpuell Date 2022-11-08 Time 08:48 Rev Time 0.00
Received By cpuell Date 2022-11-08 Time 08:48 Sent To  
Notes
2022-11-08 08:49:08PARCEL WAS CHANGED FROM 3801 GREENWOOD AVE TO 3800 &
 3802 GREENWOOD AVE, THIS PERMIT IS ONLY FOR THE SOUTH
 BUILDING 3800 GREENWOOD AVE PER CTHROOP

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-05-20 Cont ID  
Sent By cthroop Date 2023-05-20 Time 09:58 Rev Time 0.00
Received By cthroop Date 2023-05-20 Time 07:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-05-01 Cont ID  
Sent By cthroop Date 2023-05-01 Time 07:21 Rev Time 0.00
Received By cthroop Date 2023-04-29 Time 11:10 Sent To  
Notes
2023-05-01 07:24:203RD BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 NOTICE:
 THIS REVIEW IS FOR THE FRONT STRUCTURE (3800 GREENWOOD
 AVE.).
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE:
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
 1. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE) (NOT
 SUBMITTED FOR REVIEW) (3RD REQUEST)
 R401.2COMPLIANCE.
 SECTION R405 AND THE PROVISIONS OF SECTIONS R401
 THROUGH R404 LABELED MANDATORY.
  
 2. CORRECTED
  
 3. CORRECTED
 NEW COMMENTS:
  
 4. CORRECTED
  
 5. PLAN PAGES CS-00, A1-01, A1-02, A1-03 AND M1-01 ARE
 FOR THE REAR STRUCTURE. SUBMIT PLAN SHEETS FOR THE
 FRONT STRUCTURE. (PLAN PAGES A1-01 & A1-03 ARE MISSING)
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-03-03 Cont ID  
Sent By cthroop Date 2023-03-03 Time 08:32 Rev Time 0.00
Received By cthroop Date 2023-03-02 Time 12:26 Sent To  
Notes
2023-03-03 08:37:202ND BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 NOTICE:
 THIS REVIEW IS FOR THE FRONT STRUCTURE (3800 GREENWOOD
 AVE.).
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE:
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
 1. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE) (NOT
 SUBMITTED FOR REVIEW)
 R401.2COMPLIANCE.
 SECTION R405 AND THE PROVISIONS OF SECTIONS R401
 THROUGH R404 LABELED MANDATORY.
  
 2. CORRECTED
  
 3.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA
 FOR THE PROPOSED WINDOWS, WINDOW MULLIONS AND EXT.
 DOORS. (PRODUCT APPROVALS FOR WINDOWS AND MULLIONS NOT
 SUBMITTED FOR REVIEW)
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 NOTE: NOAS DO NOT HAVE COVER SHEETS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 NEW COMMENTS:
  
 4. ADDRESS ON ALL PLANS IS INCORRECT: FRONT STRUCTURE
 ADDRESS IS 3800 GREENWOOD AVE. P-LEASE CORRECT.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 5. PLAN PAGES CS-00, A1-01, A1-02, A1-03 AND M1-01 ARE
 FOR THE REAR STRUCTURE. SUBMIT PLAN SHEETS FOR THE
 FRONT STRUCTURE.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-11-01 Cont ID  
Sent By cthroop Date 2022-11-01 Time 11:00 Rev Time 0.00
Received By cthroop Date 2022-11-01 Time 06:43 Sent To  
Notes
2022-11-01 11:24:121ST BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 NOTICE:
 THIS REVIEW IS FOR THE FRONT STRUCTURE (3800 GREENWOOD
 AVE.).
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 1. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE)
 R401.2COMPLIANCE.
 SECTION R405 AND THE PROVISIONS OF SECTIONS R401
 THROUGH R404 LABELED MANDATORY.
  
 2. IDENTIFY CEILING AND WALL INSULATION TYPE AND
 R-VALUE ON PLANS.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 3.
  
 4.
  
 5.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA
 FOR THE PROPOSED WINDOWS, WINDOW MULLIONS AND EXT.
 DOORS.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 NOTE: NOAS DO NOT HAVE COVER SHEETS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-03-02 Cont ID  
Sent By mpeterso Date 2023-03-02 Time 14:00 Rev Time 0.00
Received By mpeterso Date 2023-03-02 Time 13:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-10-13 Cont ID  
Sent By mpeterso Date 2022-10-13 Time 10:15 Rev Time 0.00
Received By mpeterso Date 2022-10-13 Time 10:05 Sent To  
Notes
2022-10-13 10:25:19ELECTRIC REVIEW FAILED
 1) PLEASE DETAIL WIRE SIZES ON ELECTRICAL RISER
 DIAGRAM. NEC 215.5
 2) PLEASE DETAIL THE ELECTRIC RISER AS EITHER OVERHEAD
 OR UNDERGROUND SERVICE BUT NOT BOTH. NEC 215.5
 3) PLEASE DETAIL SMOKE ALARMS ON FLOOR PLAN AS
 REQUIRED. FBC R 314
 4) PLEASE DETAIL OUT DOOR RECEPTACLE WITHIN 25" AIR
 CONDITIONING EQUIPMENT AS REQUIRED PER NEC 210.63
 5) PLEASE DETAIL WATER HEATER LOCATION ON ELECTRICAL
 FLOOR PLAN. FBC 107.2
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop HIST HISTORICAL
Rev No 4 Status P Date 2023-06-01 Cont ID  
Sent By amhamilt Date 2023-06-01 Time 10:52 Rev Time 0.00
Received By amhamilt Date 2023-06-01 Time 10:52 Sent To  
Notes
2023-06-01 10:57:00PER DISCUSSIONS, TRIM NEEDS TO BE ADDED AROUND WINDOWS
 AND FRONT DOOR CHANGED TO REFLECT SUBMITTED NOA FOR
 MISSION STYLE DOOR RATHER THAN WHAT IS SHOWN ON
 ELEVATIONS.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop HIST HISTORICAL
Rev No 3 Status F Date 2023-05-10 Cont ID  
Sent By amhamilt Date 2023-05-10 Time 10:51 Rev Time 0.00
Received By amhamilt Date 2023-05-10 Time 10:50 Sent To  
Notes
2023-05-10 10:51:29PLEASE RESUBMIT ELEVATIONS AS DISCUSSED
  

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2023-03-29 Cont ID  
Sent By amhamilt Date 2023-03-29 Time 16:21 Rev Time 0.00
Received By amhamilt Date 2023-03-29 Time 16:21 Sent To  
Notes
2023-03-29 16:21:50THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PLEASE REVISE PLANS PER DISCUSSION DURING SITE VISIT
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2022-10-26 Cont ID  
Sent By amhamilt Date 2022-10-26 Time 09:28 Rev Time 0.00
Received By amhamilt Date 2022-10-26 Time 09:28 Sent To  
Notes
2022-10-26 09:50:45THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 ELEVATIONS SHOW HR WINDOWS, WHICH ARE NOT
 ARCHITECTURALLY APPROPRIATE FOR HOMES IN HISTORIC
 DISTRICTS. WINDOWS SHOULD BE SIZED TO FIT IN EXISTING
 OPENINGS AND MATCH THE FUNCTION AND APPEARANCE OF
 EXISTING WINDOWS. PLEASE REACH OUT FOR MORE DETAILS.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-07-18 Cont ID  
Sent By aoliver Date 2023-07-18 Time 08:41 Rev Time 0.00
Received By aoliver Date 2023-06-12 Time 11:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-06-02 Cont ID  
Sent By aoliver Date 2023-06-02 Time 08:38 Rev Time 0.00
Received By aoliver Date 2023-05-12 Time 09:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-05-10 Cont ID  
Sent By lmarchan Date 2023-05-10 Time 14:57 Rev Time 0.00
Received By lmarchan Date 2023-04-21 Time 09:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-30 Cont ID  
Sent By aoliver Date 2023-03-30 Time 12:32 Rev Time 0.00
Received By aoliver Date 2023-02-27 Time 09:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-11-01 Cont ID  
Sent By cthroop Date 2022-11-01 Time 11:24 Rev Time 0.00
Received By cthroop Date 2022-09-29 Time 04:35 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2023-05-16 Cont ID  
Sent By hmoser Date 2023-05-16 Time 13:36 Rev Time 0.00
Received By hmoser Date 2023-05-16 Time 13:32 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2023-04-24 Cont ID  
Sent By medwards Date 2023-04-24 Time 16:30 Rev Time 0.00
Received By medwards Date 2023-04-24 Time 16:30 Sent To  
Notes
2023-04-24 16:44:283RD REVIEW FMC
 PERMIT: 22061488
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE LATEST MECHANICAL DRAWING SUBMITTED IS FOR WHAT
 APPEARS TO BE A MUCH LARGER STRUCTURE. THE PROPOSED
 MECHANICAL LAYOUT SHOWS A BATHROOM AND WALK IN CLOSET
 THAT APPEARS TO BE AN ADDITION TO AN EXISTING
 STRUCTURE. PROVIDE THE ENERGY CALCULATIONS FOR THIS
 ADDITION. PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS FOR THE ENTIRE STRUCTURE. THE BATH EXHAUST
 FANS MUST BE A MINIMUM OF 50 CFM???S INTERMITTENT OR 20
 CFM CONTINUOUS. SHOW ALL THE BATH FANS AND EXHAUST
 TERMINATIONS. FBC 107.3.5
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-02-28 Cont ID  
Sent By medwards Date 2023-02-28 Time 07:56 Rev Time 0.00
Received By medwards Date 2023-02-28 Time 07:56 Sent To  
Notes
2023-02-28 07:58:28PLEASE SUBMIT THE DOCUMENTS REQUESTED IN THE 1ST CYCLE
 MECHANICAL REVIEW. THE ENERGY CALCULATIONS WERE NOT
 SUBMITTED AND THE EOR DID NOT DIGITALLY SIGN THE
 DOCUMENTS.
  
 1) OUR RECORDS INDICATE THERE HAS NEVER BEEN A
 PERMITTED MECHANICAL SYSTEM AT THIS STRUCTURE. PLEASE
 PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS
 FOR THIS PROJECT. FEC C403.2.1
  
 2) EOR THAT IS NAME ON EACH DRAWING MUST DIGITALLY SIGN
 EACH DRAWING. FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-09-30 Cont ID  
Sent By medwards Date 2022-09-30 Time 12:31 Rev Time 0.00
Received By medwards Date 2022-09-30 Time 12:31 Sent To  
Notes
2022-09-30 12:31:071ST REVIEW FMC
 PERMIT: 22061488
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) OUR RECORDS INDICATE THERE HAS NEVER BEEN A
 PERMITTED MECHANICAL SYSTEM AT THIS STRUCTURE. PLEASE
 PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS
 FOR THIS PROJECT. FEC C403.2.1
  
 2) EOR THAT IS NAME ON EACH DRAWING MUST DIGITALLY SIGN
 EACH DRAWING. FS 471/481
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-02-28 Cont ID  
Sent By rwbrown Date 2023-02-28 Time 07:05 Rev Time 0.00
Received By rwbrown Date 2023-02-28 Time 07:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-09-30 Cont ID  
Sent By rwbrown Date 2022-09-30 Time 06:27 Rev Time 0.00
Received By rwbrown Date 2022-09-30 Time 06:22 Sent To  
Notes
2022-09-30 06:35:131ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
  
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FRC P2903.1 - WATER SUPPLY DESIGN SHOWS 1/2"
 HOT WATER BRANCH LINES. THE MINIMUM SIZE FOR THE WFU'S
 SHOWN WOULD BE 3/4"
  
 2. 2017 WPB AMENDS 107.2.1 - YOU'VE MISLABELED THE
 KITCHEN SINK AS A LAVATORY.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2022-11-01 Cont ID  
Sent By cthroop Date 2022-11-01 Time 12:01 Rev Time 0.00
Received By cthroop Date 2022-11-01 Time 12:01 Sent To  
Notes
2022-11-01 12:02:04PROVISO ON PLAN PAGE S1-01: A SEPERATE ROOFING PERMIT
 IS REQUIRED. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2023-05-20 Cont ID  
Sent By cthroop Date 2023-05-20 Time 09:59 Rev Time 0.00
Received By cthroop Date 2023-05-20 Time 07:31 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-05-01 Cont ID  
Sent By cthroop Date 2023-05-01 Time 06:44 Rev Time 0.00
Received By cthroop Date 2023-04-29 Time 11:10 Sent To  
Notes
2023-05-01 06:46:14NOTICE: NEW PLAN PAGES A1-01 & A1-03 WITH CORRECTED
 ADDRESS ARE MISSING. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-02-28 Cont ID  
Sent By medwards Date 2023-02-28 Time 07:59 Rev Time 0.00
Received By medwards Date 2023-02-28 Time 07:59 Sent To  
Notes
2023-02-28 07:59:392ND ATTEMPT:
  
 EOR THAT IS NAME ON EACH DRAWING MUST DIGITALLY SIGN
 EACH DRAWING. FS 471/481
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-09-30 Cont ID  
Sent By medwards Date 2022-09-30 Time 12:36 Rev Time 0.00
Received By medwards Date 2022-09-30 Time 12:36 Sent To  
Notes
2022-09-30 12:36:57EOR THAT IS NAME ON EACH DRAWING MUST DIGITALLY SIGN
 EACH DRAWING. FS 471/481
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]

Review Stop Z ZONING
Rev No 5 Status P Date 2023-07-14 Cont ID  
Sent By amhamilt Date 2023-07-14 Time 16:35 Rev Time 0.00
Received By amhamilt Date 2023-07-14 Time 16:35 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status F Date 2023-06-01 Cont ID  
Sent By amhamilt Date 2023-06-01 Time 10:15 Rev Time 0.00
Received By amhamilt Date 2023-06-01 Time 10:15 Sent To  
Notes
2023-06-01 10:17:05THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 THE VALUE OF THE CONSTRUCTION ($55,900.00) EXCEEDS 50%
 OF THE STRUCTURE'S VALUE ($109,171.00) ACCORDING TO THE
 P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT
 TO SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE
 IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN
 ARTICLE XIV OF THE ZLDR. SUBMIT A SEPARATE LANDSCAPE
 PERMIT WITH PLANS SHOWING MATERIAL EXISTING ON SITE OR
 ANY ADDITION OF TREES OR SHRUBS TO BRING THE SITE INTO
 CONFORMITY.
  
 PLEASE APPLY FOR A SEPARATE LANDSCAPE PERMIT TO SATISFY
 THIS COMMENT
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop Z ZONING
Rev No 3 Status F Date 2023-05-10 Cont ID  
Sent By amhamilt Date 2023-05-10 Time 10:51 Rev Time 0.00
Received By amhamilt Date 2023-05-10 Time 10:51 Sent To  
Notes
2023-05-10 10:51:58PLEASE RESUBMIT SITE PLAN AS DISCUSSED

Review Stop Z ZONING
Rev No 2 Status F Date 2023-03-29 Cont ID  
Sent By amhamilt Date 2023-03-29 Time 16:22 Rev Time 0.00
Received By amhamilt Date 2023-03-29 Time 16:22 Sent To  
Notes
2023-03-29 16:22:27THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PLEASE REVISE PLANS PER DISCUSSION DURING SITE VISIT
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop Z ZONING
Rev No 1 Status P Date 2022-10-11 Cont ID  
Sent By ahamilto Date 2022-10-26 Time 09:56 Rev Time 0.00
Received By amhamilt Date 2022-10-26 Time 09:56 Sent To  
Notes
2022-10-26 09:53:33THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
  
 THE VALUE OF CONSTRUCTION EXCEEDS 50% OF THE
 IMPROVEMENT VALUE OF THE STRUCTURE, THEREFORE A
 SEPERATE LANDSCAPE PERMIT IS REQUIRED AND MUST BE
 SUBMITTED FOR ZONING APPROVAL TO MOVE FORWARD
  
 SEC 94-441 (B)
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  
 *******************************************************
 *******************************************************
 **************
 NOTE:
  
 TWO UNITS PERMITTED ON PROPERTY PER GREEN CARD (FOUND
 UNDER FORMER ADDRESS: 3801 GREENWOOD AVE).
  
  