Plan Review Details - Permit 22061401
Plan Review Stops For Permit 22061401
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-07-08 Cont ID  
Sent By rmcphers Date 2022-07-08 Time 13:16 Rev Time 0.00
Received By rmcphers Date 2022-07-08 Time 13:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-08-09 Cont ID  
Sent By jleahy Date 2022-08-09 Time 11:02 Rev Time 0.00
Received By jleahy Date 2022-08-09 Time 08:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-07-15 Cont ID  
Sent By jleahy Date 2022-07-15 Time 16:13 Rev Time 0.00
Received By jleahy Date 2022-07-15 Time 16:13 Sent To  
Notes
2022-07-15 16:17:21FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 THE TWO FEEDER TO THE PANELS ARE TOO SMALL PER TH
 STATEMENT BELOW. SHOULD BE 3/0 310.15(B)(7)
  
 FOR A FEEDER RATED 100 THROUGH 400 AMPERES, THE FEEDER
 CONDUCTORS SUPPLYING THE ENTIRE LOAD ASSOCIATED WITH A
 ONE-FAMILY DWELLING, OR THE FEEDER CONDUCTORS SUPPLYING
 THE ENTIRE LOAD ASSOCIATED WITH AN INDIVIDUAL DWELLING
 UNIT
 IN A TWO-FAMILY OR MULTIFAMILY DWELLING, SHALL BE
 PERMITTED TO HAVE AN AMPACITY NOT LESS THAN 83 PERCENT
 OF THE FEEDER
 RATING.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-08-09 Cont ID  
Sent By jleahy Date 2022-08-09 Time 11:02 Rev Time 0.00
Received By jleahy Date 2022-08-01 Time 06:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-15 Cont ID  
Sent By jleahy Date 2022-07-15 Time 16:18 Rev Time 0.00
Received By jleahy Date 2022-06-29 Time 09:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-07-01 Cont ID  
Sent By medwards Date 2022-07-01 Time 12:30 Rev Time 0.00
Received By medwards Date 2022-07-01 Time 12:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-08-02 Cont ID  
Sent By ccole Date 2022-08-02 Time 12:46 Rev Time 0.00
Received By ccole Date 2022-08-02 Time 12:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-06-30 Cont ID  
Sent By ccole Date 2022-06-30 Time 17:06 Rev Time 0.00
Received By ccole Date 2022-06-30 Time 16:46 Sent To  
Notes
2022-06-30 17:07:521ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22061401
 6/30/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) P-1: SHOW THE LOCATIONS OF THE WATER HEATERS IN THE
 ATTIC AND INDICATE HOW ACCESS FOR OBSERVATION,
 MAINTENANCE, SERVICING AND REPLACEMENT WILL BE
 PROVIDED- SEC. P2801.4 FBC RES. INDICATE A 30X30 INCH
 LEVEL WORKING SPACE WILL BE PROVIDED ON THE CONTROL
 SIDES OF THE HEATERS- SEC. 1305.1.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-08-02 Cont ID  
Sent By ccole Date 2022-08-02 Time 12:46 Rev Time 0.00
Received By ccole Date 2022-08-02 Time 12:46 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-07-08 Cont ID  
Sent By rmcphers Date 2022-07-08 Time 13:17 Rev Time 0.00
Received By rmcphers Date 2022-07-08 Time 13:17 Sent To  
Notes
2022-07-01 12:30:49MECHANICAL DIGITAL SIGNATURES APPROVED ME