Plan Review Details - Permit 22061266
| Plan Review Stops For Permit 22061266 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-06-27 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-06-27 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2022-06-27 16:36:15 | BUILDING 2 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-03-06 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-03-06 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-07-15 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-07-15 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2022-07-15 10:43:25 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.ELECTRICAL PLAN IS REQUIRED TO BE SIGNED/SEALED BY A | | | DESIGN PROFESSIONAL OR SIGNED BY THE ELECTRICAL | | | CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | | 471.003(2)(H); 471.025; WPB FBC 107.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-03-03 |
|
|
Cont ID |
|
| Sent By |
clfranci |
Date |
2023-03-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
clfranci |
Date |
2023-03-03 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
clfranci |
Date |
2022-06-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
clfranci |
Date |
2022-06-27 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-06-27 14:32:44 | THIS PLAN WAS REVIEWED AND FAILED BY CAITLIN L FRANCIS, | | | FIRE INVESTIGATOR, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THE FIRE ALARM SYSTEM IS REQUIRED TO BE MONITORED | | | ACCORDING TO NFPA 101 | | | 31.3.4.1.1 APARTMENT BUILDINGS FOUR OR MORE STORIES IN | | | HEIGHT OR WITH MORE THAN 11 DWELLING UNITS, OTHER THAN | | | THOSE | | | MEETING THE REQUIREMENTS | | | | | | 2) ELEVATOR ROOMS ARE REQUIRED TO HAVE AUTOMATIC FIRE | | | DETECTION IN ACCORDANCE WITH NFPA 72. | | | 21.3.11 ACTUATION FROM THE ELEVATOR HOISTWAY, ELEVATOR | | | MACHINE | | | ROOM, ELEVATOR MACHINERY SPACE, ELEVATOR CONTROL SPACE, | | | OR ELEVATOR CONTROL ROOM SMOKE DETECTORS, OR OTHER | | | AUTOMATIC | | | FIRE DETECTION AS PERMITTED BY 21.3.9, SHALL CAUSE | | | SEPARATE AND | | | DISTINCT VISIBLE ANNUNCIATION AT THE BUILDING FIRE | | | ALARM CONTROL | | | UNIT, OR THE FIRE ALARM CONTROL UNIT DESCRIBED IN | | | 21.3.2, AND AT | | | REQUIRED ANNUNCIATORS TO ALERT FIRE FIGHTERS AND OTHER | | | EMERGENCY | | | PERSONNEL THAT THE ELEVATORS ARE NO LONGER SAFE TO USE. | | | | | | 3) PLEASE VERIFY YOU ARE MEETING THYE REQUIREMENTS FOR | | | SLEEPING AREAS IN ACCORDANCE WITH NFPA 72 | | | 18.4.5 SLEEPING AREA REQUIREMENTS | | | | | | 4) INTERCONNECTED SINGLE STATION SMOKE ALARMS ARE | | | REQUIRED TO BE INTERCONNECTED IN THE SLEEPING UNITS BUT | | | NOT INCONJUCTION WITH THE FIRE ALARM PANEL. THIS IS | | | ALSO NOT REQUIRED TO BE COVERED UNDER THIS PERMIT. | | | | | | CAITLIN L FRANCIS | | | FIRE INVESTIGATOR | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4728 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-03-06 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-03-02 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-07-15 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-06-24 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2022-06-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-06-30 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-06-30 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-03-06 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-03-06 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-07-15 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-07-15 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2022-07-15 10:45:20 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.ELECTRICAL PLAN IS REQUIRED TO BE SIGNED/SEALED BY A | | | DESIGN PROFESSIONAL OR SIGNED BY THE ELECTRICAL | | | CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | | 471.003(2)(H); 471.025; WPB FBC 107.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | |
|
|
|