Plan Review Details - Permit 22061253
Plan Review Stops For Permit 22061253
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2023-04-11 Cont ID  
Sent By cthroop Date 2023-04-11 Time 11:11 Rev Time 0.00
Received By cthroop Date 2023-04-11 Time 10:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2023-02-09 Cont ID  
Sent By cthroop Date 2023-02-09 Time 17:11 Rev Time 0.00
Received By cthroop Date 2023-02-09 Time 16:36 Sent To  
Notes
2023-02-09 17:11:40NOTICE: BUILDING REVIEW APPROVAL IS PENDING THE
 APPROVAL OF THE SIGNATURE REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-11-22 Cont ID  
Sent By cthroop Date 2022-11-22 Time 16:11 Rev Time 0.00
Received By cthroop Date 2022-11-22 Time 16:11 Sent To  
Notes
2022-11-22 16:14:043RD BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 1.PROVIDE THE FL PRODUCT APPROVALS FOR THE PROPOSED
 WINDOWS AND EXT. DOORS AS LISTED ON PROPOSED FLOOR
 PLAN.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 NOTE: NOAS DO NOT HAVE COVER SHEETS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-10-18 Cont ID  
Sent By cthroop Date 2022-10-18 Time 09:55 Rev Time 0.00
Received By cthroop Date 2022-10-17 Time 15:51 Sent To  
Notes
2022-10-18 10:09:36PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE:
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 1. CORRECTED
  
 2. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 (PLAN
 PAGE ST-1 HAS NOT BEEN MODIFIED TO SHOW LOT DRAINAGE.
 PROVIDE EITHER TOPO ELEVATIONS OR DIRECTIONAL ARROWS,
 SHOWING THE FLOW OF WATER OFF THE LOT)
 IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
 FBC R401.3 SITE DRAINAGE
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
  
 3. CORRECTED
  
 4.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA
 FOR THE PROPOSED WINDOWS AND DOORS TO BE INSTALLED. (NO
 PRODUCT APPROVALS HAVE BEEN SUBMITTED FOR REVIEW)
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 NOTE: NOA?S DO NOT HAVE COVER SHEETS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 5.SMOKE ALARMS (SMOKE ALARM MISSING OUTSIDE GUEST
 BEDROOM, PG. E-1)
 R314.2.2ALTERATIONS, REPAIRS AND ADDITIONS.
 WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC R314.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-08-27 Cont ID  
Sent By cthroop Date 2022-08-27 Time 09:53 Rev Time 0.00
Received By cthroop Date 2022-08-27 Time 09:12 Sent To  
Notes
2022-08-27 10:01:03PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: VALUE HAS BEEN ADJUSTED TO $215,148 PER THE ICC
 BUILDING VALUATION DATA. CT
  
 1.PROVIDE A COPY OF THE MOST RECENT BOUNDARY LINE
 SURVEY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3
 IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
 FBC R401.3 SITE DRAINAGE
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
  
 3.PROVIDE THE ENERGY CALCULATIONS FOR THE ADDITION
 FBC EC R101.5.1.1.
 R101.5.1.1RESIDENTIAL ? 3 STORIES.
  
 4.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA
 FOR THE PROPOSED WINDOWS AND DOORS TO BE INSTALLED.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 NOTE: NOA?S DO NOT HAVE COVER SHEETS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 5.SMOKE ALARMS
 R314.2.2ALTERATIONS, REPAIRS AND ADDITIONS.
 WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC R314.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2023-04-10 Cont ID  
Sent By mpeterso Date 2023-04-10 Time 09:11 Rev Time 0.00
Received By mpeterso Date 2023-04-10 Time 09:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2023-01-25 Cont ID  
Sent By mpeterso Date 2023-01-25 Time 14:03 Rev Time 0.00
Received By mpeterso Date 2023-01-25 Time 13:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2022-11-21 Cont ID  
Sent By mpeterso Date 2022-11-21 Time 10:26 Rev Time 0.00
Received By mpeterso Date 2022-11-21 Time 10:26 Sent To  
Notes
2022-11-21 10:26:54PREVIOUS COMMENTS NOT ADDRESSED

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2022-10-03 Cont ID  
Sent By mpeterso Date 2022-10-03 Time 10:56 Rev Time 0.00
Received By mpeterso Date 2022-10-03 Time 10:56 Sent To  
Notes
2022-10-03 11:09:50ELECTRIC REVIEW FAILED
 1) RISER DIAGRAM AND LOAD CALCULATION DETAIL
 CONFLICTING SIZED SERVICE. PLEASE CORRECT AS APPLICABLE
 NEC 215.5
 2) ELECTRIC FLOOR PLAN DETAILS 2 ELECTRIC PANELS
 CONFLICTING WITH RISER DIAGRAM. PLEASE CORRECT A S
 APPLICABLE. FBC 107.2
 3) LOAD CALCULATION DOES NOT INCLUDE ALL LOADS AS
 REQUIRED. MISSING DOUBLE OVEN LOAD AND SECOND AIR
 HANDLER AND CONDENSOR. ENSURE ALL ELECTRIC LOADS ARE
 INCLUDED. PLEASE CORRECT AS APPLICABLE. NEC 215.5 AND
 220.40 OR 220.80
 4) ELECTRIC FLOOR PLAN DOES NOT DETAIL THE ADDITIONAL
 AIR CONDITIONING EQUIPMENT. PLEASE CORRECT AS
 APPLICABLE. FBC 107.2
 5) SEE SIGNATURE REVIEW
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-08-24 Cont ID  
Sent By mpeterso Date 2022-08-24 Time 11:01 Rev Time 0.00
Received By mpeterso Date 2022-08-24 Time 10:50 Sent To  
Notes
2022-08-24 11:05:27ELECTRIC REVIEW FAILED
 1) ELECTRIC RISER IS INCORRECT. ELECTRIC FLOOR PLAN
 DETAILS 2 ELECTRIC PANELS, RISER ONLY DETAILS 1.
 ELECTRIC LOAD CALCULATION SUGGESTS A 350 AMP SERVICE,
 THE RISER DOES NOT SPECIFY SERVICE SIZE OR
 CONDUCTORS.PLEASE CORRECT AS APPLICABLE. NEC 215.
 2) SEE FAILED SIGNATURE REVIEW
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2022-11-07 Cont ID  
Sent By rrossano Date 2022-11-07 Time   Rev Time 0.00
Received By rrossano Date 2022-11-07 Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-04-11 Cont ID  
Sent By cthroop Date 2023-04-11 Time 11:11 Rev Time 0.00
Received By cthroop Date 2023-03-28 Time 09:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-02-09 Cont ID  
Sent By cthroop Date 2023-02-09 Time 17:17 Rev Time 0.00
Received By cthroop Date 2023-01-19 Time 15:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-11-22 Cont ID  
Sent By cthroop Date 2022-11-22 Time 16:14 Rev Time 0.00
Received By cthroop Date 2022-10-28 Time 15:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-10-18 Cont ID  
Sent By cthroop Date 2022-10-18 Time 10:09 Rev Time 0.00
Received By cthroop Date 2022-09-08 Time 15:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-08-27 Cont ID  
Sent By cthroop Date 2022-08-27 Time 10:01 Rev Time 0.00
Received By cthroop Date 2022-08-02 Time 08:13 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-04-13 Cont ID  
Sent By lmarchan Date 2023-04-13 Time 15:40 Rev Time 0.00
Received By lmarchan Date 2023-04-12 Time 10:39 Sent To  
Notes
2023-04-13 15:40:50RECEIPT MU-2023-015977 - $546.52 PAID
2023-04-12 10:40:044/12/23 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-08-27 Cont ID  
Sent By cthroop Date 2022-08-27 Time 09:51 Rev Time 0.00
Received By cthroop Date 2022-08-27 Time 09:12 Sent To  
Notes
2022-08-27 09:51:39PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT
 LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO
 THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF.
 THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ
 B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE
 RECEIPT TO PROJECT DOX OR EMAIL IT TO
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-09-14 Cont ID  
Sent By medwards Date 2022-09-14 Time 06:26 Rev Time 0.00
Received By medwards Date 2022-09-14 Time 06:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-08-12 Cont ID  
Sent By medwards Date 2022-08-12 Time 13:04 Rev Time 0.00
Received By medwards Date 2022-08-12 Time 13:03 Sent To  
Notes
2022-08-12 13:04:15PROVIDE A COMPLETE MECHANICAL SUBMISSION, THERE IS
 NOTHING IN THIS SUBMITTAL FOR THE MECHANICAL SYSTEMS.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-04-04 Cont ID  
Sent By ccole Date 2023-04-04 Time 15:26 Rev Time 0.00
Received By ccole Date 2023-04-04 Time 14:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-09-15 Cont ID  
Sent By ccole Date 2022-09-15 Time 12:51 Rev Time 0.00
Received By ccole Date 2022-09-15 Time 12:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-08-11 Cont ID  
Sent By ccole Date 2022-08-11 Time 14:12 Rev Time 0.00
Received By ccole Date 2022-08-11 Time 13:51 Sent To  
Notes
2022-08-11 14:13:121ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22061253
 8/11/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P-1 SANITARY RISER: NOT MORE THAN ONE
 WET-VENTED FIXTURE DRAIN- WATER CLOSET OR TUB- SHALL
 DISCHARGE UPSTREAM OF THE DRY-VENTED LAVATORY DRAIN
 CONNECTION- SEC. P3108.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2022-10-18 Cont ID  
Sent By cthroop Date 2022-10-18 Time 09:55 Rev Time 0.00
Received By cthroop Date 2022-10-17 Time 15:51 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-08-27 Cont ID  
Sent By cthroop Date 2022-08-27 Time 09:51 Rev Time 0.00
Received By cthroop Date 2022-08-27 Time 09:12 Sent To  
Notes
2022-08-27 09:53:51PLAN REVIEW ROOFING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE PRODUCT APPROVALS FOR SECONDARY WATER
 BARRIER PER FBC R905.1.1.
 UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL
 CONFORM TO THE APPLICABLE STANDARDS? AND SHALL BE
 APPLIED AND ATTACHED IN ACCORDANCE WITH SECTION
 R905.1.1.1, R905.1.1.2 OR R905.1.1.3, AS APPLICABLE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2023-04-10 Cont ID  
Sent By mpeterso Date 2023-04-10 Time 09:08 Rev Time 0.00
Received By mpeterso Date 2023-04-10 Time 09:08 Sent To  
Notes
2023-04-10 09:11:15SIGNATURE REVIEW PASSED
 SOME FILES IN DRAWING FOLDER HAVE AN INVALID SIGNATURE,
 CUSTOMER EMAILED ME CORRECTLY DIGATALLY SIGNED DRAWINGS
 AND I UPLOADED THEM TO THE SIGNATURE FOLDER. BETWEEN
 BOTH SIGNATURE AND DRAWING FOLDER ALL PLANS PASSED
 SIGNATURE REVIEW. MP

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2023-02-09 Cont ID  
Sent By cthroop Date 2023-02-09 Time 17:11 Rev Time 0.00
Received By cthroop Date 2023-01-25 Time 14:04 Sent To  
Notes
2023-02-09 17:17:334TH SIGNATURE REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: ALL PLAN PAGES
  
 SIGNATURE VALIDATION STATUS: DIGITAL SIGNATURE IS
 INVALID
 ISSUED BY: IGC CA 1 IDENTRUST GLOBAL COMMON
  
 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A
 VALID DIGITAL SIGNATURE.
 A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE
 IS NOT CONSIDERED A VALID DIGITAL SIGNATURE.
  
 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S.
 668.003 (3);
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
 F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS)
 F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS)
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-11-21 Cont ID  
Sent By mpeterso Date 2022-11-21 Time 10:27 Rev Time 0.00
Received By mpeterso Date 2022-11-21 Time 10:26 Sent To  
Notes
2022-11-21 10:28:58SIGNATURE REVIEW FAILED
 1) ADOBE AND BLUEBEAM SOFTWARE DETAIL A CORRUPT,
 INVALID SIGNATURE. CORRECT AS OUTLINED BELOW.
  
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-10-03 Cont ID  
Sent By mpeterso Date 2022-10-03 Time 11:13 Rev Time 0.00
Received By mpeterso Date 2022-10-03 Time 11:13 Sent To  
Notes
2022-10-03 11:15:41SIGNATURE REVIEW FAILED
 1) PLANS SIGNED BY MR ROJAS PE DETAIL AN INCORRECT TIME
 STAMP ON SIGNATURE. PLEASE CORRECT AS APPLICABLE
  
 FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF
 RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 DIGITALLY SEALED AND SIGNED.
  
 PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS
 FOLLOWING PROJECTDOX INSTRUCTIONS
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-08-24 Cont ID  
Sent By mpeterso Date 2022-08-24 Time 11:06 Rev Time 0.00
Received By mpeterso Date 2022-08-24 Time 11:06 Sent To  
Notes
2022-08-24 11:10:50SIGNATURE REVIEW FAILED.
 1) A REVIEW OF AOR SEAL AND SIGNATURE CERTIFICATION
 SHOWS IT IS CORRUPT AND INVALD
  
 FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF
 RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 DIGITALLY SEALED AND SIGNED.
  
 PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS
 FOLLOWING PROJECTDOX INSTRUCTIONS
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop Z ZONING
Rev No 5 Status P Date 2023-04-05 Cont ID  
Sent By asangele Date 2023-04-05 Time 14:56 Rev Time 0.00
Received By asangele Date 2023-04-05 Time 14:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status F Date 2023-01-20 Cont ID  
Sent By asangele Date 2023-01-20 Time 13:39 Rev Time 0.00
Received By asangele Date 2023-01-20 Time 13:38 Sent To  
Notes
2023-01-20 13:41:21FAILED
 1/20/2023
  
  
 A SEPARATE PERMIT IS REQUIRED FOR LANDSCAPE
  
  
 RAY CARANCI (SENIOR LANDSCAPE PLANNER)
 561-8221562
  
  
  
  
 ALEXIS SANGELEER
 PLANNER
 ASANGELEER

Review Stop Z ZONING
Rev No 3 Status F Date 2022-11-07 Cont ID  
Sent By asangele Date 2022-11-07 Time 15:21 Rev Time 0.00
Received By asangele Date 2022-11-07 Time 15:21 Sent To  
Notes
2022-11-07 15:23:2811/7/2022
  
 A LANDSCAPE EPERMIT IS REQUIRED
  
 THE VALUE OF THE CONSTRUCTION ($130,000) EXCEEDS 50% OF
 THE STRUCTURE'S IMPROVEMENT VALUE ($158,869) ACCORDING
 TO THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE,
 PURSUANT TO SECTION 94-441(B) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE
 SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
 REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE
 SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A
 LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE
 INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES
 NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING
 APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL
 TO BRING THE SITE INTO CONFORMITY
  
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2022-09-16 Cont ID  
Sent By asangele Date 2022-09-16 Time 14:57 Rev Time 0.00
Received By asangele Date 2022-09-16 Time 14:57 Sent To  
Notes
2022-09-16 14:59:11FAILED
 9/16/2022
  
 ALL PLANS SHOULD MATCH AND NOT BE SHOWING DIFFERENT
 SETBACKS ON DIFFERENT SHEETS.
  
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2022-08-10 Cont ID  
Sent By asangele Date 2022-08-10 Time 11:42 Rev Time 0.00
Received By asangele Date 2022-08-10 Time 11:42 Sent To  
Notes
2022-08-10 11:54:038/10/2022
 FAIL
 WOULD NOT MEET PRIMARY STRUCTURE SIDE SETBACK
 REQUIREMENT. MEASUREMENT IS TAKEN FROM THE POINTS OF
 WALLS CLOSEST TO THE PROPERTY LINE.
 ARTICLE III. SECTION 94-72
 SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]