Plan Review Details - Permit 22061160
Plan Review Stops For Permit 22061160
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2022-08-15 Cont ID  
Sent By shill Date 2022-08-15 Time 07:50 Rev Time 0.00
Received By shill Date 2022-08-15 Time 07:50 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-07-24 Cont ID  
Sent By shill Date 2022-07-24 Time 08:16 Rev Time 0.00
Received By shill Date 2022-07-24 Time 08:16 Sent To  
Notes
2022-07-24 08:16:59PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2022-10-03 Cont ID  
Sent By shill Date 2022-10-03 Time 12:03 Rev Time 0.00
Received By shill Date 2022-10-03 Time 12:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2022-09-27 Cont ID  
Sent By cthroop Date 2022-09-27 Time 06:36 Rev Time 0.00
Received By cthroop Date 2022-09-27 Time 05:26 Sent To  
Notes
2022-09-27 06:39:234TH BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: COMMENTS FROM 3RD REVIEW HAVE NOT BEEN
 ADDRESSED, SEE BELOW:
  
 COMMENTS NOT ADDRESSED. THE ONLY NEW DOCUMENT SUBMITTED
 WAS A SPEC SHEET FOR ADURA MAX. PLEASE SEE ITEM 3
 BELOW.
  
 1. SIGNATURE REVIEW APPROVED ON 9/29/2022 BY S HILL.
  
 2. MANNINGTON ADURA MAX LVT FLOORING IS PROPOSED. SPEC
 SHEET INDICATES THAT THE SOUNDPROOFING IS ATTACHED, SO
 FLAME SPREAD IS NOT REQUIRED. THE STC AND IIC TESTS ARE
 REQUIRED.
  
 3. PROVIDE THE TEST REPORTS FOR THE FLOORING PROPOSED:
  
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-09-01 Cont ID  
Sent By shill Date 2022-09-01 Time 07:43 Rev Time 0.00
Received By shill Date 2022-09-01 Time 07:43 Sent To  
Notes
2022-09-01 07:43:06****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 COMMENTS NOT ADDRESSED. THE ONLY NEW DOCUMENT SUBMITTED
 WAS A SPEC SHEET FOR ADURA MAX. PLEASE SEE ITEM 3
 BELOW.
  
 1. PLANS WERE PREPARED BY AN ENGINEER BUT ARE NOT
 DIGITALLY SIGNED. UPLOAD DIGITALLY SIGNED PLANS. IF YOU
 WOULD LIKE FOR US TO CONFIRM BEFORE YOU UPLOAD THAT
 DOCUMENTS ARE DIGITALLY SIGNED, EMAIL TO [email protected]
 AND [email protected] FOR VERIFICATION.
  
 2ND REVIEW, RESPONSE LETTER STATES THAT THE ENGINEER
 WILL DEAL WITH THE BUILDING DEPARTMENT. THIS ENGINEER
 HAS A DIGITAL SIGNATURE. SOMEONE ON THE APPLICANT'S
 TEAM IS TO UPLOAD DIGITALLY SIGNED PAGES. THE NEW PAGES
 SHOULD BE NAMED SO THEY SUPERSEDE THE PAGES PREVIOUSLY
 UPLOADED.
  
 2. MANNINGTON ADURA MAX LVT FLOORING IS PROPOSED. SPEC
 SHEET INDICATES THAT THE SOUNDPROOFING IS ATTACHED, SO
 FLAME SPREAD IS NOT REQUIRED. THE STC AND IIC TESTS ARE
 REQUIRED.
  
 3. PROVIDE THE TEST REPORTS FOR THE FLOORING PROPOSED:
  
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-08-15 Cont ID  
Sent By shill Date 2022-08-15 Time 07:51 Rev Time 0.00
Received By shill Date 2022-08-15 Time 07:51 Sent To  
Notes
2022-08-15 07:57:05****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 COMMENTS NOT ADDRESSED:
  
 1. PLANS WERE PREPARED BY AN ENGINEER BUT ARE NOT
 DIGITALLY SIGNED. UPLOAD DIGITALLY SIGNED PLANS. IF YOU
 WOULD LIKE FOR US TO CONFIRM BEFORE YOU UPLOAD THAT
 DOCUMENTS ARE DIGITALLY SIGNED, EMAIL TO [email protected]
 AND [email protected] FOR VERIFICATION.
  
 2ND REVIEW, RESPONSE LETTER STATES THAT THE ENGINEER
 WILL DEAL WITH THE BUILDING DEPARTMENT. THIS ENGINEER
 HAS A DIGITAL SIGNATURE. SOMEONE ON THE APPLICANT'S
 TEAM IS TO UPLOAD DIGITALLY SIGNED PAGES. THE NEW PAGES
 SHOULD BE NAMED SO THEY SUPERSEDE THE PAGES PREVIOUSLY
 UPLOADED.
  
 2. MANNINGTON ADURA MAX LVT FLOORING IS PROPOSED. SPEC
 SHEET INDICATES THAT THE SOUNDPROOFING IS ATTACHED, SO
 FLAME SPREAD IS NOT REQUIRED. THE STC AND IIC TESTS ARE
 REQUIRED.
  
 3. PROVIDE THE TEST REPORTS FOR THE FLOORING PROPOSED:
  
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-07-24 Cont ID  
Sent By shill Date 2022-07-24 Time 08:17 Rev Time 0.00
Received By shill Date 2022-07-24 Time 08:17 Sent To  
Notes
2022-07-24 08:20:34****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. PLANS WERE PREPARED BY AN ENGINEER BUT ARE NOT
 DIGITALLY SIGNED. UPLOAD DIGITALLY SIGNED PLANS. IF YOU
 WOULD LIKE FOR US TO CONFIRM BEFORE YOU UPLOAD THAT
 DOCUMENTS ARE DIGITALLY SIGNED, EMAIL TO [email protected]
 AND [email protected] FOR VERIFICATION.
  
 2. NEW FLOORING IS PROPOSED. REVISE THE PLAN TO CLARIFY
 FLOORING TYPE - FOR INSTANCE TILE, LVT, WOOD, ETC. IF
 THE FLOORING ALONE DOES NOT HAVE TEST REPORTS TO SHOW
 COMPLIANCE WITH STC AND IIC REQUIREMENTS, UNDERLAYMENT
 IS REQUIRED. IF UNDERLAYMENT IS NOT REQUIRED, PROVIDE
 STC AND IIC TEST REPORTS FOR THE PROPOSED FLOORING. SEE
 BELOW FOR ADDITIONAL INFO.
  
 3. IF UNDERLAYMENT IS REQUIRED, PROVIDE THE FOLLOWING
 TEST REPORTS FOR THE PROPOSED UNDERLAYMENT STC, IIC,
 FLAME SPREAD:
  
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-07-15 Cont ID  
Sent By fgiaquin Date 2022-07-15 Time 23:54 Rev Time 0.00
Received By fgiaquin Date 2022-07-14 Time 19:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-09-19 Cont ID  
Sent By   Date 2022-09-19 Time   Rev Time 0.00
Received By bdolan Date 2022-09-19 Time 11:33 Sent To  
Notes
2022-09-19 11:35:21REVIEW COMMENTS ADDRESSED.
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-08-09 Cont ID  
Sent By cwalker Date 2022-08-09 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-06-29 Cont ID  
Sent By   Date 2022-06-29 Time   Rev Time 0.00
Received By bdolan Date 2022-06-29 Time 10:03 Sent To  
Notes
2022-06-27 09:14:07FIRE REVIEW COMMENTS:
 THE PLAN INDICATES NEW VINYL FLOORING TO BE INSTALLED.
 PROVIDE THE MANUFACTURERS DOCUMENTATION OF THE TESTING
 OF THE MATERIAL FOR FIRE PERFORMANCE TO INCLUDE THE
 CRITICAL RADIANT FLUX. NFPA 101 10.2.7
 C. WALKER
 561-804-4762
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-10-03 Cont ID  
Sent By shill Date 2022-10-03 Time 12:06 Rev Time 0.00
Received By shill Date 2022-10-02 Time 09:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-09-27 Cont ID  
Sent By cthroop Date 2022-09-27 Time 06:40 Rev Time 0.00
Received By cthroop Date 2022-09-14 Time 09:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-09-01 Cont ID  
Sent By shill Date 2022-09-01 Time 07:44 Rev Time 0.00
Received By shill Date 2022-08-23 Time 16:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-08-15 Cont ID  
Sent By shill Date 2022-08-15 Time 07:57 Rev Time 0.00
Received By shill Date 2022-08-06 Time 07:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-24 Cont ID  
Sent By shill Date 2022-07-24 Time 08:23 Rev Time 0.00
Received By shill Date 2022-06-24 Time 05:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-09-16 Cont ID  
Sent By medwards Date 2022-09-16 Time 06:09 Rev Time 0.00
Received By medwards Date 2022-09-16 Time 06:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-06-30 Cont ID  
Sent By medwards Date 2022-06-30 Time 06:10 Rev Time 0.00
Received By medwards Date 2022-06-30 Time 06:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-09-16 Cont ID  
Sent By ccole Date 2022-09-16 Time 14:27 Rev Time 0.00
Received By ccole Date 2022-09-16 Time 14:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-06-28 Cont ID  
Sent By ccole Date 2022-06-28 Time 12:15 Rev Time 0.00
Received By ccole Date 2022-06-28 Time 11:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2022-09-29 Cont ID  
Sent By shill Date 2022-09-29 Time 07:09 Rev Time 0.00
Received By shill Date 2022-09-29 Time 07:09 Sent To  
Notes
2022-09-29 07:10:29RECEIVED FROM ENGINEER. PLANS ARE IN THE WRONG
 ORIENTATION. THIS MAY BE WHY DIGITAL SIGNATURE HAS BEEN
 AN ISSUE. UPLOADED TO PROJECTDOX SIGNATURE FOLDER AND
 PASSED SIGNATURE.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2022-09-27 Cont ID  
Sent By cthroop Date 2022-09-27 Time 06:39 Rev Time 0.00
Received By cthroop Date 2022-09-27 Time 05:26 Sent To  
Notes
2022-09-27 06:40:39SEE COMMENTS UNDER 4TH BLDG. REVIEW. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-09-01 Cont ID  
Sent By shill Date 2022-09-01 Time 07:43 Rev Time 0.00
Received By shill Date 2022-09-01 Time 07:43 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-08-15 Cont ID  
Sent By shill Date 2022-08-15 Time 07:57 Rev Time 0.00
Received By shill Date 2022-08-15 Time 07:57 Sent To  
Notes
2022-08-15 07:57:26SEE BUILDING

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-07-24 Cont ID  
Sent By shill Date 2022-07-24 Time 08:21 Rev Time 0.00
Received By shill Date 2022-07-24 Time 08:21 Sent To  
Notes
2022-07-24 08:21:59SEE BUILDING REVIEW
  