| Plan Review Stops For Permit 22061092 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2022-11-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-11-30 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-11-30 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2022-11-30 12:19:04 | SPOKE WITH APPLICANT THEY WILL BE DOING PERMITS UNDER | | | THE SEPARATE PARCELS, THIS PERMIT IS FOR 309 CLEMATIS | | | ST ONLY |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2022-09-29 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-09-29 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-09-29 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2022-09-29 08:40:58 | PREVIOUS COMMENTS NOT ADDRESSED |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2022-09-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-09-01 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-09-01 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2022-09-01 16:31:07 | PLANS PLANS REFRENCING BUILDINGS 309 311 AND 313 | | | CLEMATIS ST. 311 CLEMATIS STREET IS NOT A CURRENT | | | ADDRESS AND 313 CLEMATIS ST IS ON A SEPARATE PARCEL. | | | PLEASE CONTACT [email protected] OR CALL | | | 561-805-6659 TO DISCUSS ADDRESSING ISSUES. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
N |
Date |
2022-12-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-05 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-05 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2022-12-05 13:25:44 | SEE DEMO PERMITS | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2022-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-10-07 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-10-07 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2022-10-07 09:53:54 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-02 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-01 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2022-09-02 08:25:45 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2023-07-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-14 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-14 |
Time |
08:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
F |
Date |
2023-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-11 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-11 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2023-07-11 15:25:34 | REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING A-204 WAS REVISED AND THE NOTE FOR THE | | | ACCESSIBLE POOL ENTRY WAS REMOVED - PLEASE SHOW THE | | | ACCESSIBLE POOL ENTRY - FBC A 242.2 | | | YOU CAN ADD "ACCESSIBLE POOL LIFT" TO THE DEFERRED | | | SUBMITTALS LIST ON DRAWING CVR | | | | | | 2) NOA 20-1130.10 HAS BEEN SUBMITTED FOR THE ROLL UP | | | DOOR (MARKED D8 ON THE DRAWING) - PLEASE SHOW HOW THIS | | | DOOR IS SELF CLOSING PER FBC 716.5.9 DOOR CLOSING. FIRE | | | DOORS SHALL BE LATCHING AND SELF- OR AUTOMATIC-CLOSING | | | IN ACCORDANCE WITH THIS SECTION. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
F |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-26 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-26 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2023-06-26 14:24:18 | REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING A-201 HAS A STATEMENT THAT A 90 MIN. FIRE | | | RATED DOOR IS REQUIRED - PLEASE SHOW THE LOCATION OF | | | THIS 90 MIN. FIRE RATED DOOR. | | | | | | 2) DOOR D8 SHOULD BE FIRE RATED - FBC TABLE 716.5 - | | | BASED ON THE EXTERIOR WALL RATING FBC TABLE 705.8 | | | | | | 3) DOOR SCHEDULE NEEDS TO SHOW THE DOOR FIRE RATINGS - | | | FBC TABLE 716.5 | | | | | | 4) PLEASE SHOW THE FIRE RATED DOORS TO BE SELF CLOSING | | | - FBC 716.5.9 | | | | | | 5) PLEASE SHOW THE ACCESSIBLE SEATING AREA FOR THE | | | TABLES AND BAR ON THE GROUND FLOOR REMODEL (309) - FBC | | | A 226.2 | | | | | | 6) PLEASE SHOW THE ACCESSIBLE POOL ENTRY - FBC A 242.2 | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-20 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-20 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2023-06-20 13:40:46 | REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING A102 FAR DRAWINGS OVERLAID THE DRAWING A102 | | | THE ROOF DECK LIFE SAFETY PLAN IN PROJECTDOX - PLEASE | | | CORRECT | | | | | | 2) DRAWING A101 ACTIVE USE DRAWING OVERLAID THE DRAWING | | | A101 THE GROUND FLOOR LIFE SAFETY PLAN IN PROJECTDOX - | | | PLEASE CORRECT | | | | | | 3) DRAWING A201 AND A101 NEED TO MATCH THE REVISED | | | FLOOR PLAN AS SHOWN ON DRAWING (A101 ACTIVE USE PLAN). | | | | | | 4) SHOW THE DOOR SIZES (OVERHEAD DOOR ETC.) I DO NOT | | | SEE A DOOR SCHEDULE IN PROJECTDOX - FBC 107.2 | | | | | | 5) PLEASE SHOW THE REAR TRASH ROOM DOOR TYPE,SIZE AND | | | OPENING DIRECTION - FBC 107.2 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2023-04-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-04-03 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-03 |
Time |
08:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2023-03-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-07 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-07 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2023-03-07 09:50:24 | ADDITION AND REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE SLIDING ROOF DRAWINGS AND CALCULATIONS SHOW WIND | | | DESIGN USING WIND SPEED OF 170MPH = BUILDING IS A RISK | | | CATEGORY III - WIND DESIGN NEEDS TO BE BASED ON 180 MPH | | | PER FBC WPB SECTION 120 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2023-02-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-16 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-16 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2023-02-16 14:14:45 | ADDITION AND REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) BUILDING IS A RISK CATEGORY III - WIND DESIGN NEEDS | | | TO BE BASED ON 180 MPH PER FBC WPB SECTION 120 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-01-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-20 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-20 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2023-01-20 13:30:01 | ADDITION AND REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING A201 AND A101 THE FLOOR PLAN SHOULD MATCH | | | (VESTIBULE WALL CHANGES). FBC WPB 107 | | | | | | 2) THE SIGNED AND SEALED STRUCTURAL DRAWINGS AND THE | | | SIGNED AND SEALED THRESHOLD INSPECTOR FORM DO NOT SHOW | | | AS DIGITALLY SIGNED IN ADOBE READER - SIGNED AND SEALED | | | DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | | | | 3) NEW DOORS AT THE FRONT OF THE BUILDING SHOULD NOT | | | ENCROACH IN TO THE PUBLIC RIGHT OF WAY FBC 3202.2 | | | ENCROACHMENTS ABOVE GRADE AND BELOW 8 FEET IN HEIGHT. | | | DOORS AND WINDOWS SHALL NOT OPEN OR PROJECT INTO THE | | | PUBLIC RIGHT-OF-WAY. | | | | | | 4) BUILDING IS A RISK CATEGORY III - WIND DESIGN NEEDS | | | TO BE BASED ON 180 MPH PER FBC WPB SECTION 120 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-12-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-05 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-05 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2022-12-05 13:50:09 | ADDITION AND REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING A201 SHOWS EXTERIOR WALL OPENING | | | CALCULATIONS - THE REAR WALL WHICH IS 9' 8" FROM THE | | | CENTER OF THE ALLEY HAS A DOOR OPENING WHICH IS NOT | | | SHOWN ON THE OPENING CALCULATIONS. - FBC TABLE 705.8 | | | | | | 2) THE SIGNED AND SEALED STRUCTURAL DRAWINGS AND THE | | | SIGNED AND SEALED THRESHOLD INSPECTOR FORM DO NOT SHOW | | | AS DIGITALLY SIGNED IN ADOBE READER - SIGNED AND SEALED | | | DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | | | | 3) NEW DOORS AT THE FRONT OF THE BUILDING SHOULD NOT | | | ENCROACH IN TO THE PUBLIC RIGHT OF WAY FBC 3202.2 - | | | PLEASE PROVIDE A SURVEY | | | | | | 4) CANNOT HAVE AN ELEVATOR IN A STAIR EXIT VESTIBULE - | | | FBC 1028.1 EXCEPTION 2 - 2.4.THE AREA IS USED ONLY FOR | | | MEANS OF EGRESS AND EXITS DIRECTLY TO THE OUTSIDE. | | | | | | 5) BUILDING IS A RISK CATEGORY III - WIND DESIGN NEEDS | | | TO BE BASED ON 180 MPH PER FBC WPB SECTION 120 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-10-07 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-10-07 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2022-10-07 08:57:28 | ADDITION AND REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE NEW EXTERIOR WINDOWS, DOORS | | | AND ROOFING SYSTEMS - ALL PRODUCT APPROVALS NEED TO BE | | | REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER | | | OF RECORD FBC WPB 107.3.4 | | | | | | 2) PLEASE SHOW ON THE DRAWINGS THAT TERMITE TREATMENT | | | IS A REQUIREMENT PER FBC 1816 | | | | | | 3) PLEASE SHOW WALL DESIGNATIONS ON THE FLOOR PLANS - | | | SHOW FIRE WALLS ETC. FBC WPB 107.2 | | | | | | 4) BASED ON THE DISTANCE FROM THE CENTER OF THE ALLY | | | (SHOW THE DISTANCE) TO THE REAR WALL. THE REAR WALL | | | NEEDS TO SHOW AS 1 HOUR FIRE RATED - FBC TABLE 602 | | | | | | 5) BASED ON THE DISTANCE FROM THE CENTER OF THE ALLY | | | (SHOW THE DISTANCE) TO THE REAR WALL - PLEASE SHOW THE | | | ALLOWABLE NON PROTECTED OR PROTECTED OPENING | | | CALCULATIONS FOR EACH FLOOR - FBC TABLE 705.8 | | | | | | 6) PLEASE SHOW THE POOL BARRIER (DOORS, LOCKS, LATCH | | | HEIGHT ETC.) AT THE STAIR AND ELEVATOR DOORS TO COMPLY | | | WITH FBC 454.1.3.1.9 | | | | | | 7) PLEASE SHOW THE ACCESSIBLE POOL ENTRY - FBC A 242.2 | | | SWIMMING POOLS. | | | AT LEAST TWO ACCESSIBLE MEANS OF ENTRY SHALL BE | | | PROVIDED FOR SWIMMING POOLS. ACCESSIBLE MEANS OF ENTRY | | | SHALL BE SWIMMING POOL LIFTS COMPLYING WITH 1009.2; | | | SLOPED ENTRIES COMPLYING WITH 1009.3; TRANSFER WALLS | | | COMPLYING WITH 1009.4; TRANSFER SYSTEMS COMPLYING WITH | | | 1009.5; AND POOL STAIRS COMPLYING WITH 1009.6. AT LEAST | | | ONE ACCESSIBLE MEANS OF ENTRY PROVIDED SHALL COMPLY | | | WITH 1009.2 OR 1009.3. | | | | | | 8) FOR THE REMODELED GROUND FLOOR = PLEASE SHOW THE | | | DIFFERENT DINING AREA LOCATIONS FOR THE ACCESSIBLE | | | SEATING - FBC 226 | | | | | | 9) FOR THE REMODELED GROUND FLOOR = PLEASE SHOW AT | | | LEAST 1 ACCESSIBLE SEAT AT EACH BAR LOCATION (SHOW | | | COUNTER HEIGHT, KNEE AND TOE CLEARANCES ETC. ) - FBC | | | 226.2 | | | | | | 10) PLEASE PROVIDE TYPICAL GUARDRAIL AND HANDRAIL | | | DETAILS - SHOWING HEIGHTS, OPENING SPECS., HANDRAIL | | | EXTENSIONS ETC. FBC 1014 AND 1015 | | | | | | 11) PLEASE PROVIDE A THRESHOLD INSPECTION PLAN - FBC | | | (CITY AMENDMENTS)110.8.1 THRESHOLD INSPECTION PLAN. THE | | | ENFORCING AGENCY SHALL REQUIRE A SPECIAL INSPECTOR TO | | | PERFORM STRUCTURAL INSPECTIONS ON A THRESHOLD BUILDING | | | PURSUANT TO A STRUCTURAL INSPECTION PLAN PREPARED BY | | | THE ENGINEER OF RECORD. | | | | | | 12) THE STRUCTURAL DRAWINGS NEED TO CONTAIN THIS NOTE - | | | THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT | | | 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED | | | TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF | | | RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE | | | ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM | | | BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS | | | AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH | | | THIS SECTION AND CHAPTER 633 FLORIDA STATUTES. | | | | | | 13) PLEASE READ AND FILL OUT THE REQUIRED DOCUMENTS PER | | | THE "GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | | THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS". | | | YOU CAN E MAIL ME AND ASK FOR A COPY. | | | | | | 14) PLEASE PROVIDE A COPY OF THE UNITY OF TITLE. | | | | | | 15) A SEPARATE PERMIT IS REQUIRED FOR THE BUILDING | | | DEMO. | | | | | | 16) ITEMS SUCH AS BUT NOT LIMITED TO RAILING, EXTERIOR | | | WINDOW, DOOR AND ROOFING SYSTEMS PRODUCT APPROVALS MAY | | | BE DEFERRED SUBMITTALS BY LISTING ITEMS TO BE DEFERRED | | | ON THE CONSTRUCTION DOCUMENTS - FBC WPB 107.3.4.1 | | | DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, | | | DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF | | | THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE | | | APPLICATION AND THAT ARE TO BE SUBMITTED TO THE | | | BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL | | | OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF | | | THE BUILDING OFFICIAL. THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE | | | DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR | | | REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED | | | SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL | | | REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL | | | WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL | | | DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL | | | CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED | | | SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE | | | DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE | | | BUILDING OFFICIAL. | | | | | | 17) STRUCTURAL AND FIRE PROTECTION DRAWINGS DO NOT SHOW | | | AS DIGITALLY SIGNED IN ADOBE READER - SIGNED AND SEALED | | | DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-02 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-01 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2022-09-01 15:55:02 | ADDITION AND REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING A303 - RESTROOM DOOR NEAR THE REAR STAIR | | | APPEARS TO SWING IN THE EGRESS PATH - FBC 1005.7.1 | | | DOORS. | | | DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED | | | WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY | | | POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE | | | THAN ONE-HALF. | | | | | | 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE NEW EXTERIOR WINDOWS, DOORS | | | AND ROOFING SYSTEMS - ALL PRODUCT APPROVALS NEED TO BE | | | REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER | | | OF RECORD FBC WPB 107.3.4 | | | | | | 3) DRAWING A 403 - ELEVATIONS ARE NOT LABELED CORRECTLY | | | (BOTH ARE LABELED EXISTING). | | | | | | 4) DRAWING A 201 - PLEASE SHOW THE USE FOR EACH ROOM OR | | | SPACE. | | | | | | 5) PLEASE SHOW THAT TERMITE TREATMENT IS A REQUIREMENT | | | PER FBC 1816 | | | | | | 6) DRAWING A 501 - SHOW THE CEILING HEIGHT FOR THE | | | EGRESS CATWALK AT STAIRS - FBC 1003.2 | | | | | | 7) DRAWING A 604 - GAZEBO WALL DETAIL - WHAT IS (W-4H | | | AND W-4B) ? | | | | | | 8) PLEASE SHOW ALL CEILING HEIGHTS (OFFICE, STORAGE | | | ETC.) - FBC 1208.2 | | | | | | 9) DRAWING A 102 - UNDER OCCUPANCY LOAD I DO NOT SEE | | | THE POOL AREA OCCUPANT LOAD - PLEASE PROVIDE BUILDING | | | AREA SQUARE FOOTAGES. | | | | | | 10) PLEASE PROVIDE A BUILDING SPRINKLER LAYOUT PLAN - | | | FBC 903.2.1 | | | | | | 11) PLEASE SHOW THE LOCATION FOR THE OCCUPANT LOAD SIGN | | | PER FBC 1004.9 | | | | | | 12) ON DRAWING A 101 IN THE "BUILDING CODE ANALYSIS" | | | CHART PLEASE DESCRIBE THE BUILDING SEPARATION FROM THE | | | ADJOINING BUILDINGS - FBC 508 NON-SEPARATED, SEPARATED | | | - SHOW THE WALL SEPARATION TYPE - FIRE BARRIER FBC | | | 707.3.9 OR FIRE WALL FBC 706 - SHOW THE OCCUPANCY | | | CLASSIFICATION FOR THE ADJOINING UNITS OR BUILDINGS FBC | | | CHAPTER 3. | | | | | | 13) PLEASE SHOW WALL DESIGNATIONS ON THE FLOOR PLANS - | | | SHOW FIRE WALLS ETC. FBC WPB 107.2 | | | | | | 14) THE REAR WALL NEEDS TO SHOW AS 1 HOUR FIRE RATED - | | | FBC TABLE 602 | | | | | | 15) BASED ON THE DISTANCE FROM THE CENTER OF THE ALLY | | | TO THE REAR WALL OPENINGS - PLEASE SHOW THE ALLOWABLE | | | NON PROTECTED OPENING CALCULATIONS - FBC TABLE 705.8 | | | | | | 16) PLEASE SHOW THE POOL BARRIER (DOORS, LOCKS, LATCH | | | HEIGHT ETC.) AT THE STAIR AND ELEVATOR DOORS TO COMPLY | | | WITH FBC 454.1.3.1.9 | | | | | | 17) PLEASE SHOW THE ACCESSIBLE POOL ENTRY - FBC A 242.2 | | | SWIMMING POOLS. | | | AT LEAST TWO ACCESSIBLE MEANS OF ENTRY SHALL BE | | | PROVIDED FOR SWIMMING POOLS. ACCESSIBLE MEANS OF ENTRY | | | SHALL BE SWIMMING POOL LIFTS COMPLYING WITH 1009.2; | | | SLOPED ENTRIES COMPLYING WITH 1009.3; TRANSFER WALLS | | | COMPLYING WITH 1009.4; TRANSFER SYSTEMS COMPLYING WITH | | | 1009.5; AND POOL STAIRS COMPLYING WITH 1009.6. AT LEAST | | | ONE ACCESSIBLE MEANS OF ENTRY PROVIDED SHALL COMPLY | | | WITH 1009.2 OR 1009.3. | | | | | | 18) PLEASE SHOW THE DIFFERENT DINING AREA LOCATIONS FOR | | | THE ACCESSIBLE SEATING - FBC 226 | | | | | | 19) PLEASE SHOW AT LEAST 1 ACCESSIBLE SEAT AT EACH BAR | | | LOCATION (SHOW COUTER HEIGHT, KNEE AND TOE CLEARANCES | | | ETC. ) - FBC 226.2 | | | | | | 20) DRAWING A 603 - DETAIL P1, P2, P3 - THE MAX. 36 | | | INCHES FOR THE GRAB BAR HEIGHT SHOULD BE SHOWN TO THE | | | TOP OF THE GRIPPING SURFACE FBC A 609.4 | | | | | | 21) THE MOVABLE ROOF SYSTEM ENGINEERING FROM "F AND M | | | MAFCO" NEEDS TO BE SIGNED AND SEALED BY THE DESIGNER - | | | FBC WPB 107.1 | | | | | | 22) THE MOVABLE ROOF SYSTEM ENGINEERING FROM "F AND M | | | MAFCO" NEEDS TO BE REVIEWED AND MARKED APPROVED BY THE | | | ENGINEER OF RECORD (LOADS MUST BE CHECKED BY THE | | | ENGINEER OF RECORD AS NOTED ON THE RETRACTABLE ROOF | | | DRAWING) FBC WPB 107.3.4 | | | | | | 23) PLEASE PROVIDE TYPICAL GUARDRAIL AND HANDRAIL | | | DETAILS - SHOWING HEIGHTS, OPENING SPECS., HANDRAIL | | | EXTENSIONS ETC. FBC 1014 AND 1015 | | | | | | 24) PLEASE PROVIDE A THRESHOLD INSPECTION PLAN - FBC | | | (CITY AMENDMENTS)110.8.1 THRESHOLD INSPECTION PLAN. THE | | | ENFORCING AGENCY SHALL REQUIRE A SPECIAL INSPECTOR TO | | | PERFORM STRUCTURAL INSPECTIONS ON A THRESHOLD BUILDING | | | PURSUANT TO A STRUCTURAL INSPECTION PLAN PREPARED BY | | | THE ENGINEER OF RECORD. | | | | | | 25) THE STRUCTURAL DRAWINGS NEED TO CONTAIN THIS NOTE - | | | THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT | | | 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED | | | TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF | | | RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE | | | ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM | | | BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS | | | AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH | | | THIS SECTION AND CHAPTER 633 FLORIDA STATUTES. | | | | | | 26) PLEASE READ AND FILL OUT THE REQUIRED DOCUMENTS PER | | | THE "GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | | THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS". | | | YOU CAN E MAIL ME AND ASK FOR A COPY. | | | | | | 27) PLEASE PROVIDE A COPY OF THE UNITY OF TITLE. | | | | | | 28) A SEPARATE PERMIT IS REQUIRED FOR THE BUILDING | | | DEMO. | | | | | | 29) ITEMS SUCH AS BUT NOT LIMITED TO EXTERIOR WINDOW, | | | DOOR AND ROOFING SYSTEMS PRODUCT APPROVALS MAY BE | | | DEFERRED SUBMITTALS BY LISTING ITEMS TO BE DEFERRED ON | | | THE CONSTRUCTION DOCUMENTS - 107.3.4.1 DEFERRED | | | SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, DEFERRED | | | SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF THE DESIGN | | | THAT ARE NOT SUBMITTED AT THE TIME OF THE APPLICATION | | | AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL | | | WITHIN A SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL | | | ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING | | | OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS | | | ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE | | | BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED SUBMITTAL | | | ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW | | | THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A | | | NOTATION INDICATING THAT THE DEFERRED SUBMITTAL | | | DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL | | | CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED | | | SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE | | | DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE | | | BUILDING OFFICIAL. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2023-01-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-01-27 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-01-27 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2022-12-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-12-09 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-12-09 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2022-12-09 08:04:52 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) UNLESS YOU CAN PROVIDE DOCUMENTATION FOR FLOOR BOXES | | | ON THE POOL DECK FLOOR, THAT THE OUTLETS WILL HAVE | | | COVERS THAT ARE WEATHER PROOF WITH CORDS PLUGED IN | | | PLEASE REMOVE ALL FLOOR OUTLETS IN THIS AREA. | | | 406.9(B)(1), 110.3(B) | | | | | | PLEASE INDICATE FOR ME WHAT TYPE OF DECKING IS TO BE | | | USED AROUND THE POOL, CONCRETE, WOOD, | | | COMPOSITE,ECT,ECT.) | | | | | | 2) FANS IN THE POOL AREA, PLEASE SHOW ON THE PLAN THE | | | HEIGHT AND DISTANCE FROM THE EDGE OF THE POOL TO THESE | | | FANS. 680.22(B)(4) | | | | | | 3) PAGE E104 SPEAKERS IN POOL OR ABOVE POOL? IF IN POOL | | | PLEASE PROVIDE A LISTING FOR THE SPEAKERS. 110.3(BB) | | | | | | 4) E-106 POOL EQUIPMENT CORROSIVE AREA? | | | | | | 680.14 CORROSIVE ENVIRONMENT. | | | (A) GENERAL. | | | AREAS WHERE POOL SANITATION CHEMICALS ARE STORED, AS | | | WELL AS AREAS WITH CIRCULATION PUMPS, AUTOMATIC | | | CHLORINATORS, FILTERS, OPEN AREAS UNDER DECKS ADJACENT | | | TO OR ABUTTING THE POOL STRUCTURE, AND SIMILAR | | | LOCATIONS SHALL BE CONSIDERED TO BE A CORROSIVE | | | ENVIRONMENT. THE AIR IN SUCH AREAS SHALL BE CONSIDERED | | | TO BE LADEN WITH ACID, CHLORINE, AND BROMINE VAPORS, OR | | | ANY COMBINATION OF ACID, CHLORINE, OR BROMINE VAPORS, | | | AND ANY LIQUIDS OR CONDENSATION IN THOSE AREAS SHALL BE | | | CONSIDERED TO BE LADEN WITH ACIDS, CHLORINE, AND | | | BROMINE VAPORS, OR ANY COMBINATION OF ACID, CHLORINE, | | | OR BROMINE VAPORS. | | | | | | (B) WIRING METHODS. | | | WIRING METHODS IN THE AREAS DESCRIBED IN 680.14(A) | | | SHALL BE LISTED AND IDENTIFIED FOR USE IN SUCH AREAS. | | | RIGID METAL CONDUIT, INTERMEDIATE METAL CONDUIT, RIGID | | | POLYVINYL CHLORIDE CONDUIT, AND REINFORCED | | | THERMOSETTING RESIN CONDUIT SHALL BE CONSIDERED TO BE | | | RESISTANT TO THE CORROSIVE ENVIRONMENT SPECIFIED IN | | | 680.14(A). |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2022-12-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-12-09 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-12-08 |
Time |
12:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-12-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-10-18 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-10-18 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2022-10-20 15:32:28 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) PAGE 103, 302 WEATHER PROOF OUTLETS IN WET LOCATION | | | REQUIRE A WEATHER PROOF INUSE COVE COVER | | | | | | 46.9 0(1) RECEPTACLES OF 15 AND 20 AMPERES IN A WET | | | LOCATION. | | | | | | RECEPTACLES OF 15 AND 20 AMPERES, 125 AND 250 VOLTS | | | INSTALLED IN A WET LOCATION SHALL HAVE AN ENCLOSURE | | | THAT IS WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG | | | CAP IS INSERTED. AN OUTLET BOX HOOD INSTALLED FOR | | | THIS PURPOSE SHALL BE LISTED AND SHALL BE IDENTIFIED AS | | | ???EXTRA-DUTY.??? OTHER LISTED PRODUCTS, ENCLOSURES, OR | | | ASSEMBLIES PROVIDING WEATHERPROOF PROTECTION THAT DO | | | NOT UTILIZE AN OUTLET BOX HOOD NEED NOT BE MARKED | | | ???EXTRA DUTY.??? | | | | | | PLEASE SUBMIT A LISTING FOR THE INUSE FLOOR BOX COVER. | | | | | | 2) RISER IS MISSING PLEASE SUBMIT A RISER DIAGRAM 215.5 | | | | | | 3) PANEL SCHEDULES ARE MISSING. | | | | | | 4) GFCI REQUIREMENTS HAVE BEEN EXPANDED IN THE 2017 NEC | | | PLEASE READ 210.8(B) FOR TYPE AND LOCATION OF GFCIS. | | | | | | 210.8(B) OTHER THAN DWELLING UNITS. | | | | | | ALL SINGLE-PHASE RECEPTACLES RATED 150 VOLTS TO GROUND | | | OR LESS, 50 AMPERES OR LESS AND THREE-PHASE RECEPTACLES | | | RATED 150 VOLTS TO GROUND OR LESS, 100 AMPERES OR LESS | | | INSTALLED IN THE FOLLOWING LOCATIONS SHALL HAVE | | | GROUND-FAULT | | | CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-01 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-07-30 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2022-07-30 18:52:32 | | | | | | | 1) 225 KVA TRANSFORMER TO BE INSTALLED PER 450.21(B) | | | | | | OVER 112 KVA. INDIVIDUAL DRY-TYPE TRANSFORMERS OF MORE | | | THAN 112KVA RATING SHALL BE INSTALLED IN A TRANSFORMER | | | ROOM | | | OF FIRE-RESISTANT CONSTRUCTION. UNLESS SPECIFIED | | | OTHERWISE IN THIS ARTICLE, THE TERM FIRE RESISTANT | | | MEANS A CONSTRUCTION HAVING A | | | MINIMUM FIRE RATING OF 1 HOUR. | | | | | | 2) PLEASE LAYOUT ELECTRICAL ROOM IN NEW BAR AREA FOR | | | WORKING CLEARANCES AND OVERHEAD CLEARANCES FOR | | | MECHANICAL EQUIPMENT. 110.26 | | | | | | 3) ALL OUTDOOR OUTLETS 125, AND 240 VOLT TO BE GFCI | | | PROTECTED PER 210.8(B) 50 AMPERES SINGLE PHASE AND 100 | | | AMPERES FOR THREE PHASE. | | | | | | 210.8(B) OTHER THAN DWELLING UNITS. ALL SINGLE-PHASE | | | RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 50 | | | AMPERES OR LESS AND THREEPHASE | | | RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 100 | | | AMPERES OR LESS INSTALLED IN THE FOLLOWING LOCATIONS | | | SHALL HAVE GROUND-FAULT | | | CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL. | | | | | | RECEPTACLES OF 15 AND 20 AMPERES IN A WET LOCATION. | | | RECEPTACLES OF 15 AND 20 AMPERES, 125 AND 250 VOLTS | | | INSTALLED | | | IN A WET LOCATION SHALL HAVE AN ENCLOSURE THAT IS | | | WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS | | | INSERTED. AN OUTLET | | | BOX HOOD INSTALLED FOR THIS PURPOSE SHALL BE LISTED AND | | | SHALL BE IDENTIFIED AS ?EXTRA-DUTY.? OTHER LISTED | | | PRODUCTS, ENCLOSURES, OR | | | ASSEMBLIES PROVIDING WEATHERPROOF PROTECTION THAT DO | | | NOT UTILIZE AN OUTLET BOX HOOD NEED NOT BE MARKED | | | ?EXTRA DUTY.? | | | | | | 4) RECEPACLES THAT LOOK LIKE THEY ARE FLOOR BOXES IN | | | THE POOL AREA DECK AND OTHER AREAS ON ROOF DECK PLEASE | | | SHOW DETAIL. 406.9 | | | | | | 5) COVERS FOR RECEPATCLES INSTALLED IN DAMP/WET | | | LOCATION SHALL MEET THE REQUIREMENTS OF 406.9(A) | | | | | | 406.9(A) DAMP LOCATIONS. A RECEPTACLE INSTALLED | | | OUTDOORS IN A LOCATION PROTECTED FROM THE WEATHER OR IN | | | OTHER DAMP LOCATIONS | | | SHALL HAVE AN ENCLOSURE FOR THE RECEPTACLE THAT IS | | | WEATHERPROOF WHEN THE RECEPTACLE IS COVERED (ATTACHMENT | | | PLUG CAP NOT | | | INSERTED AND RECEPTACLE COVERS CLOSED). | | | | | | 6) SOME OF THE SPEAKERS ARE ON 120 VOLT CIRCUITS AND | | | SOME ARE NOT, PLEASE DISGUIGUISH BETWEEN THE TYPES | | | 110.3 | | | | | | 7) FANS INSTALLED AROUND POOL NEED TO SHOW DISTANCE AND | | | HEIGHT FROM POOL. 680.22(B)(1) | | | | | | 8) MDP1LOAD CALCULATION SHOWS EXISTING? I DO NOT SEE | | | PANELS A,B AND OTHER LOADS NOT LISTED ON PANEL SCHEDULE | | | FOR MDP1. 220 | | | PLEASE SHOW HOW THE LOAD CALCULATION WAS ARRIVED AT FOR | | | MDP1, AND MDP2 YOU CAN NOT USE A DEMAND ON A PANEL THAT | | | WAS | | | ALREADY DEMANDED WHEN SIZING THE PANEL. | | | | | | 9) IS THE VIP LEVEL AND THE ROOF LEVEL THE SAME? | | | | | | 10) NEED A LAYOUT OF THE POOL EQUIPMENT ON PLAN. | | | | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
2 |
Status |
P |
Date |
2022-11-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-11-15 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-10-18 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2022-11-15 08:15:41 | TV , VOICE, DATA , AND SPEAKERS |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
F |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-01 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-01 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2022-08-01 12:45:50 | TV, VOICE AND DATA, SOME SPEAKERS. NEED TO SPELL OUT | | | WHAT LOW VOLTAGE SYSTEMS ARE. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
7 |
Status |
P |
Date |
2023-06-01 |
|
|
Cont ID |
|
| Sent By |
lquinone |
Date |
2023-06-01 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
2023-06-01 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
6 |
Status |
F |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
lquinone |
Date |
2023-05-25 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
2023-05-25 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2023-05-25 07:17:49 | AWAITING SITE PLAN APPROVAL AND FORMAL ENGINEERING | | | SUBMITTAL. | | | | | | THANKS, | | | LINDA M. QUINONES-CINTRON, PROJECT COORDINATOR, | | | ENGINEERING SERVICES DEPARTMENT (561) 494-1085 | | | [email protected] | | | FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
5 |
Status |
F |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
lquinone |
Date |
2023-05-04 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
2023-05-04 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2023-05-04 11:16:47 | AWAITING SITE PLAN APPROVAL AND FORMAL ENGINEERING | | | SUBMITAL. | | | | | | THANKS, | | | LINDA M. QUINONES-CINTRON, PROJECT COORDINATOR, | | | ENGINEERING SERVICES DEPARTMENT (561) 494-1085 | | | [email protected] | | | FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
F |
Date |
2023-04-06 |
|
|
Cont ID |
|
| Sent By |
lquinone |
Date |
2023-04-06 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
2023-04-06 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2023-04-06 14:13:39 | AWAITING SITE PLAN APPROVAL AND FORMAL ENGINEERING | | | SUBMITAL. | | | | | | THANKS, | | | LINDA M. QUINONES-CINTRON, PROJECT COORDINATOR, | | | ENGINEERING SERVICES DEPARTMENT (561) 494-1085 | | | [email protected] | | | FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2023-03-13 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2023-03-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2023-03-13 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2023-02-21 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2023-02-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2023-02-21 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-02-21 10:04:44 | AWAITING SITE PLAN APPROVAL AND FORMAL ENG SUBMITTAL. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2023-02-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2023-02-13 |
Time |
|
Sent To |
I |
|
| Notes |
| 2023-02-13 10:12:11 | AWAITING SITE PLAN APPROVAL AND FORMAL ENG SUBMITTAL. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
9 |
Status |
P |
Date |
2023-07-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-14 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2023-07-14 09:04:34 | FIRE PROVISO: | | | | | | THE COOKING HEARTH AND/OR THE OPEN PIT WOOD BURNING | | | GRILL IS NOT APPROVED UNDER THIS PERMIT NOR | | | ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR | | | TO APPROVAL. | | | | | | IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
8 |
Status |
P |
Date |
2023-07-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-12 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2023-07-12 14:13:19 | FIRE PROVISO: | | | | | | THE COOKING HEARTH AND/OR THE OPEN PIT WOOD BURNING | | | GRILL IS NOT APPROVED UNDER THIS PERMIT NOR | | | ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR | | | TO APPROVAL. | | | | | | IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
7 |
Status |
P |
Date |
2023-06-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-06-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-06-28 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2023-06-28 09:46:18 | FIRE PROVISO: | | | | | | THE COOKING HEARTH AND/OR THE OPEN PIT WOOD BURNING | | | GRILL IS NOT APPROVED UNDER THIS PERMIT NOR | | | ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR | | | TO APPROVAL. | | | | | | IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2023-06-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-06-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-06-15 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2023-06-15 10:16:55 | FIRE PROVISO: | | | | | | THE COOKING HEARTH AND/OR THE OPEN PIT WOOD BURNING | | | GRILL IS NOT APPROVED UNDER THIS PERMIT NOR | | | ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR | | | TO APPROVAL. | | | | | | IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2023-02-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-02-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-02-16 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2023-02-16 09:46:03 | FIRE PROVISO: | | | | | | THE COOKING HEARTH AND/OR THE OPEN PIT WOOD BURNING | | | GRILL IS NOT APPROVED UNDER THIS PERMIT NOR | | | ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR | | | TO APPROVAL. | | | | | | IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2023-01-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-01-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-01-20 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2023-01-24 13:13:10 | FIRE PROVISO: | | | | | | THE COOKING HEARTH AND/OR THE OPEN PIT WOOD BURNING | | | GRILL IS NOT APPROVED UNDER THIS PERMIT NOR | | | ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR | | | TO APPROVAL. | | | | | | IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2022-12-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-12-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-11-28 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2022-12-02 11:48:34 | FIRE PROVISO: | | | THE COOKING HEARTH IS NOT APPROVED UNDER THIS PERMIT | | | NOR | | | ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR | | | TO APPROVAL. | | | | | | IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-09-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-09-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-09-27 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2022-09-27 10:53:15 | FIRE PROVISO: | | | | | | PLEASE ENSURE THE FOLLOWING COMMENTS ARE ADDRESSED | | | DURING CONSTUCTION AND AT THE TIME OF FIRE FINAL | | | INSPECTIONS. | | | | | | | | | 1) SHEET A 203 - THERE IS AN INDICATION OF POOL | | | EQUIPMENT ROOM/AREA/PLATFORM | | | | | | THE DOOR LEADING TO THIS AREA SHALL BE PLACARD PER NFPA | | | 1 & 704 FOR THE CHEMICAL STORAGE. | | | | | | | | | 1A) SHEET A 203 - PLEASE PROVIDE THE TYPE, AMOUNT, | | | SEPARATION AND SAFE POOL CHEMICAL STORAGE IN THE POOL | | | EQUIPMENT AREA PER NFPA 1 | | | AND ALL APPLICABLES CODES. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-07-06 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-07-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2022-07-06 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2022-06-29 13:44:21 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET E 000 - THERE ARE NO INDICATIONS OF FIRE ALARM | | | DEVICES, EQUIPMENT, NOR FIRE AMARM WORK | | | | | | THE FIRE ALARM SYSTEM SHALL BE MAINTAINED THROUGHOUT | | | DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE ALARM, INCLUDING DEMO, SHALL BE | | | DONE UNDER SEPARATE PERMITS & SHOP DRAWINGS. | | | | | | PLEASE PROVIDE A NOTE OF ACKNOWLEDGMENT. | | | | | | | | | | | | 2) ELECTRICAL SHEETS - THERE ARE NO INDICATIONS OF ANY | | | ELECTRICAL SHEETS SHOWING THE LOCATION OF REQUIRED EXIT | | | LIGHTS & EMERGENCY LIGHTING. | | | | | | EXIT MARKINGS, EXIT TAVEL PATH SIGNS AND EMEREGENCY | | | LIGHTING ARE REQUIRED BY NFPA 101 CH 12 NEW ASSEMBLY | | | OCCUPANCY & CH 7 MEANS OF EGRESS. | | | | | | PLEASE PROVIDE SPECIF DETAILS IN COMPLIANCE WITH THE | | | CODE. | | | | | | | | | 3) SHEET A 203 - THERE IS AN INDICATION OF POOL | | | EQUIPMENT ROOM/AREA/PLATFORM | | | | | | THE DOOR LEADING TO THIS AREA SHALL BE PLACARD PER NFPA | | | 1 & 704 FOR THE CHEMICAL STORAGE. | | | | | | | | | 3A) SHEET A 203 - PLEASE PROVIDE THE TYPE AND AMOUNT OF | | | PROPOSED CHEMICAL STORAGE IN THE POOL EQUIPMENT AREA. | | | | | | PER NFPA 1 | | | | | | | | | | | | | | | | | | WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET REVISION | | | CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2023-03-02 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-02 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-02 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-11-28 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-11-28 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2022-07-20 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-20 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-07-20 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2023-07-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-14 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-13 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2023-07-12 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-07-12 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-07-11 |
Time |
08:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2023-07-10 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-07-10 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-06-22 |
Time |
16:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2023-06-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-06-21 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-06-14 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-06-13 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-05-15 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2023-05-12 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-12 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-04-28 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2023-04-27 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-04-27 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-03-30 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2023-03-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-03-27 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-03-01 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-02-28 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-02-28 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-02-15 |
Time |
07:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-02-14 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-02-14 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-01-19 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-12-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-12-09 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-11-23 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-11-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-11-15 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-23 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-02 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-06-28 |
Time |
09:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-07-14 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2023-07-14 09:29:43 | IMPACT FEE QUEST UPLOADED. PBCGOV EMAILED AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-02 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-02 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2022-09-02 08:26:50 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2023-07-10 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-07-10 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-07-10 |
Time |
06:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-26 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-26 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2023-05-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-10 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-10 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2023-05-10 16:36:03 | 6TH REVIEW FMC | | | PERMIT: | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE NEW ENGINEER KELVIN T CHANG MUST SUBMIT ALL NEW | | | MECHANICAL DESIGN WITH THEIR DIGITAL SIGNATURE. THERE | | | ARE SOME DRAWINGS WITH THE ORIGINAL ENGINEER, JAMES C. | | | DIPASQUALE. DIGITAL SIGNATURE IN TIS DESIGN. SHEETS | | | M-002, M-003, M-501 STILL BEAR THE DIGITAL SIGNATURE OF | | | JAMES C. DIPASQUALE. | | | 61G15-27.001 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2023-04-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-06 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-06 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2023-04-06 15:35:27 | IT APPEARS THAT THE MECHANICAL DOCUMENTS NOW HAVE A | | | REVISION 5. THERE ARE NO CLOUDS ON THE DRAWINGS FOR | | | THIS 5TH REVISION AND NO NARRATIVE SUBMITTED FOR THIS | | | 5TH REVISION. PLEASE CLOUD THE CHANGES MADE FOR THIS | | | REVISION AND PROVIDE A NARRATIVE OF CHANGES FOR THIS | | | 5TH REVISION. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2023-01-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-24 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-24 |
Time |
17:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2022-11-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-30 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-30 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2022-11-30 09:22:05 | 3RD REVIEW FMC | | | PERMIT: 22061092 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | THE COMMENTS BELOW FOR THE KITCHEN HOOD EXHAUST IS ONLY | | | HERE BECAUSE THEY ARE MINGLED WITH THE DESIGN OF THIS | | | BUILDING, IF I WAITED UNTIL THE KITCHEN HOOD PERMITS | | | AND REVIEW IT COULD MEAN A LOT OF CHANGES. NOTE THAT | | | THIS IS NOT A REVIEW OF THE KITCHEN HOODS AND GREASE | | | DUCT. JUST REFERENCE FOR THE CONSTRUCTION OF THIS | | | REMODEL. | | | | | | 1) I DO NOT SEE THE NOTE ON THE MECHANICAL DRAWINGS | | | THAT STATES THE KITCHEN HOOD AND GREASE DUCT WILL | | | REQUIRE A SEPARATE PERMIT APPLICATION AND SUBMITTAL FOR | | | PLAN REVIEW AS THEY WILL NOT BE REVIEWED UNDER THIS | | | PERMIT. PLEASE ADD THE NOTE TO THE MECHANICAL DRAWINGS. | | | | | | 2) I DO NOT SEE THE NOTE ON THE MECHANICAL DRAWINGS | | | THAT STATES THE REFRIGERATION FOR THE WALK-IN COOLERS | | | AND FREEZER WILL REQUIRE A SEPARATE PERMIT APPLICATION | | | AND SUBMITTAL FOR PLAN REVIEW AS THEY WILL NOT BE | | | REVIEWED UNDER THIS PERMIT. PLEASE ADD THE NOTE TO THE | | | MECHANICAL DRAWINGS. | | | | | | 3) SHEET M-102: THE HOOD EXHAUST TERMINATION LOCATION | | | MUST BE A MINIMUM OF 10 FEET FROM THE PROPERTY LINE. | | | FMC 501.3.1 ITEM NUMBER 2 | | | | | | 4) THE WOMEN???S BATH ROOMS ON THE 1ST FLOOR SHOWS AN | | | EXHAUST GRILLE IN THE HANDICAP BOOTH WITH 0 CFM???S OF | | | EXHAUST. PLEASE CORRECT THIS. FBC 107.3.5 | | | | | | 5) THE DIGITAL SIGNATURE ON THE MECHANICAL DRAWINGS ARE | | | COPIES OF THE ORIGINAL AS THEY DO NOT SHOW AS DIGITAL | | | SIGNATURES IN OUR SOFTWARE. PLEASE PROVIDE THE ORIGINAL | | | DIGITALLY SIGNED DRAWINGS. FS 471/481 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-09-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-26 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-26 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2022-09-26 17:17:42 | 2ND REVIEW FMC | | | PERMIT: 22061092 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M-102: IT APPEARS THAT KEF-2 IS EXHAUSTING | | | TOWARDS THE STAIRWAY DOOR. PLEASE SHOW THIS KEF-2 IS | | | NOT EXHAUSTING WITHIN 10 FEET OF ANY OPENING INTO THE | | | BUILDING. ALSO SHOW THE PROPERTY LINE AND THE EXHAUST | | | DISTANCE TO THE PROPERTY LINE FOR THE KEF???S. FMC | | | 501.3.1-2 | | | | | | 2) PLEASE PROVIDE A LIST OF THE AREAS EF-1 SERVES, IT | | | APPEARS THAT IT IS EXHAUSTING A DISHWASHER ALONG WITH | | | THE BATHROOM EXHAUSTS. FBC 107.3.5 | | | | | | 3) PLEASE SHOW THAT EF-1 IS MEETING THE REQUIREMENT OF | | | EXHAUST BEING 3 FEET FROM AN OPENING INTO THE BUILDING. | | | FMC 501.3.1-3 | | | | | | 4) SHEET M-001, WATER SOURCE HEAT PUMP SCHEDULE | | | INDICATES A TOTAL TONNAGE OF ALL HP???S TO BE 49 TONS. | | | THE COOLING TOWER SCHEDULE INDICATES CT-1 IS 50 TONS. | | | THE MECHANICAL EQUIPMENT SIZING CALCULATIONS SHOW A | | | TOTAL SYSTEM LOADS OF 208105 BTU???S WHICH IF DIVIDED | | | BY 12,000 WOULD BE 17.34 TONS. PLEASE PROVIDE A | | | MECHANICAL EQUIPMENT SIZING CALCULATION FOR THE ENTIRE | | | PROJECT. FBC 107.3.5 | | | | | | 5) 2ND ATTEMPT; PLEASE PROVIDE THE OUTDOOR AIR | | | CALCULATIONS FOR EACH USE OF SPACE FOR THIS BUILDING. | | | FMC 403.3.1.1 AND TABLE 403.3.1.1 | | | | | | 6) SHEET M-104: PROVIDE A DETAIL DRAWING OF THE KEF???S | | | PENETRATION OF THE ROOF AND THE ANCHORAGE OF THE | | | KEF???S. IS THE RETRACTABLE ROOF GOING TO OPEN AROUND | | | THESE KEF???S? FBC 107.3.5 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-18 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-18 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2022-07-18 14:59:53 | 1ST REVIEW FMC | | | PERMIT: 22061493 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A MECHANICAL DEMO PLAN FOR THIS PROJECT. FBC | | | 107.2.1 | | | | | | 2) PROVIDE THE ENERGY CALCULATIONS. FEC 101.5.1.1.2 | | | | | | 3) PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. FEC 403.2.1 | | | | | | 4) PROVIDE THE OUT DOOR AIR CALCULATIONS. FMC 403.3.1.1 | | | | | | 5) ADD NOTE ON THE MECHANICAL DRAWINGS INDICATING THAT | | | THE HOODS AND GREASE DUCT SYSTEMS AND THE REFRIGERATION | | | SYSTEMS IE WALK-IN COOLERS AND WALK-IN FREEZERS WILL | | | REQUIRE A SEPARATE PERMIT AND PLAN REVIEW AND WILL NOT | | | BE REVIEWED UNDER THIS PERMIT. FBC 107.2.1 | | | | | | 6) SHEET M-103: REVISE THE DRAWING TO SHOW THE BATHROOM | | | EXHAUST FOR THE BATHROOMS IN THE DINING AREA. FMC TABLE | | | 403.3.1.1 | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2023-03-02 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-02 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-02 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2023-02-16 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-16 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-16 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2023-01-20 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-20 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-20 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-01-20 08:42:26 | 4TH PLUMBING REVIEW | | | | | | | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. DONE | | | | | | | | | 2. ---NOT ADDRESSED----2017 WPB AMEND - 107.3 - THE | | | GREASE INTERCEPTOR REQUIRES A SEPARATE PERMIT AND NEEDS | | | TO BE APPLIED FOR BEFORE THE RELEASE OF THE MASTER | | | PERMIT. | | | | | | 3. --DONE | | | | | | | | | 4. DONE | | | | | | 5. DONE | | | | | | 6. -DONE | | | | | | | | | 7. DONE | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-11-28 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-11-28 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-11-28 12:04:19 | 3RD PLUMBING REVIEW | | | | | | | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. DONE | | | | | | | | | 2. ---NOT ADDRESSED----2017 WPB AMEND - 107.3 - THE | | | GREASE INTERCEPTOR REQUIRES A SEPARATE PERMIT AND NEEDS | | | TO BE APPLIED FOR BEFORE THE RELEASE OF THE MASTER | | | PERMIT. | | | | | | 3. --DONE | | | | | | | | | 4. DONE | | | | | | 5. DONE | | | | | | 6. -DONE | | | | | | | | | 7. DONE | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-09-26 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-09-26 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-09-26 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2022-09-26 12:40:28 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. ---NOT ADDRESSED----2020 FPC 1003.3.1 - ONLY DEVICES | | | DESIGNED TO RECEIVE FATS, OILS AND GREASE SHALL BE | | | DIRECTED TO THE GREASE WASTE. PLEASE SHOW THAT THE ICE | | | BINS AND HANDS SINK GO TO THE SANITARY AND NOT THE | | | GREASE WASTE. | | | | | | 2. ---NOT ADDRESSED----2017 WPB AMEND - 107.3 - THE | | | GREASE INTERCEPTOR REQUIRES A SEPARATE PERMIT AND NEEDS | | | TO BE APPLIED FOR BEFORE THE RELEASE OF THE MASTER | | | PERMIT. | | | | | | 3. ---NOT ADDRESSED----2020 FPC 905.4 - ON EACH END OF | | | THE BATHROOMS, THE VENT NEAR THE WATER CLOSET IS | | | HORIZONTAL AND CANNOT BE UNTIL IT IS 6" ABOVE THE FLOOD | | | RIM OF THE FIXTURES SERVED. | | | | | | 4. ---NOT ADDRESSED----2020 FPC 905.4 - THE VENTS FOR | | | THE GREASE INTERCEPTORS ARE HORIZONTAL WHILE DRY AND | | | CANNOT BE. THE VENT CANNOT BE A HORIZONTAL DRY VENT | | | UNTIL IT IS 6" ABOVE THE FLOOD RIM OF THE FIXTURES | | | SERVED. | | | 5. DONE | | | | | | 6. ---NOT ADDRESSED----WPB ORD. SEC. 90 - 126 - THE | | | DISCHARGE FROM AIR HANDLERS/AIR CONDITIONING CONDENSATE | | | CANNOT DISCHARGE INTO THE SANITARY. IT MUST GO TO THE | | | STORM OR OTHER APPROVED PLACE OF DISPOSAL. | | | | | | 7. ---NOT ADDRESSED----2020 FPC 419.5/607.1.2 - PLEASE | | | INCLUDE A DETAIL SHOWING COMPLIANCE WITH THE | | | REQUIREMENTS FOR TEMPERED WATER FOR PUBLIC HANDWASHING | | | STATIONS THAT INCLUDES THE LIMITING DEVICE THAT | | | CONFORMS TO ASSE 1070. | | | | | | | | | | | | | | | ---NOT ADDRESSED----WHEN RESUBMITTING, IT IS HELPFUL TO | | | PROVIDE A RESPONSE LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-07-20 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-20 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-07-20 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2022-07-20 12:11:41 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FPC 1003.3.1 - ONLY DEVICES DESIGNED TO RECEIVE | | | FATS, OILS AND GREASE SHALL BE DIRECTED TO THE GREASE | | | WASTE. PLEASE SHOW THAT THE ICE BINS AND HANDS SINK GO | | | TO THE SANITARY AND NOT THE GREASE WASTE. | | | | | | 2. 2017 WPB AMEND ? 107.3 - THE GREASE INTERCEPTOR | | | REQUIRES A SEPARATE PERMIT AND NEEDS TO BE APPLIED FOR | | | BEFORE THE RELEASE OF THE MASTER PERMIT. | | | | | | 3. 2020 FPC 905.4 - ON EACH END OF THE BATHROOMS, THE | | | VENT NEAR THE WATER CLOSET IS HORIZONTAL AND CANNOT BE | | | UNTIL IT IS 6? ABOVE THE FLOOD RIM OF THE FIXTURES | | | SERVED. | | | | | | 4. 2020 FPC 905.4 - THE VENTS FOR THE GREASE | | | INTERCEPTORS ARE HORIZONTAL WHILE DRY AND CANNOT BE. | | | THE VENT CANNOT BE A HORIZONTAL DRY VENT UNTIL IT IS 6? | | | ABOVE THE FLOOD RIM OF THE FIXTURES SERVED. | | | 5. WPB ORD. SEC 90 - 205 EXCEPTIONS TO DISCHARGE TO | | | STORM WATER | | | SWIMMING POOL WATER SHALL NOT BE DISCHARGED TO SANITARY | | | SEWER WITHOUT PRIOR APPROVAL FROM THE PUBLIC UTILITIES | | | DEPARTMENT. | | | SWIMMING POOL WATER MAY BE DISCHARGED TO THE CITY | | | STORMWATER SEWER ONLY IF THE WATER IS DECHLORINATED | | | ACCORDING TO SECTION 90-205(1) OF THE CITY OF WEST PALM | | | BEACH CODE OF ORDINANCES. SUBMIT THE MANUFACTURER'S | | | SPECIFICATION FOR THE DICHLORINATION SYSTEM FOR REVIEW | | | AND STAMPING BEFORE THE INSPECTION. AT THE TIME OF POOL | | | WATER DISCHARGE, THE FOLLOWING WILL BE REQUIRED: | | | - THE RECEIVING INLET MUST BE PROTECTED (FILTER CLOTH | | | TO KEEP EXCESS SEDIMENTS FROM ROADWAY WASHING INTO THE | | | INLET). | | | - NO DISCHARGE HOSE CAN BE DIRECTLY INSERTED INTO THE | | | INLET TO DISCHARGE EFFLUENT. | | | - WHENEVER POSSIBLE, DISCHARGE EFFLUENT SHALL BE | | | ALLOWED TO FILTER THROUGH GRASS AREA ON THE POOL | | | OWNER'S PROPERTY BEFORE DISCHARGING ON CITY PROPERTY. | | | - DISCHARGE SHALL NOT FLOOD STREETS OR NEIGHBORING | | | PROPERTY. | | | - FOR TECHNICAL QUESTIONS, CONTACT O&M SUPERINTENDENT | | | STEPHON HARRIS AT [email protected] OR 561-822-2168. | | | - FOR STORMWATER DISCHARGE COMPLIANCE QUESTIONS, PLEASE | | | CONTACT CHRIS JACKSON, ENVIRONMENTAL COMPLIANCE | | | SPECIALIST III, PUBLIC UTILITIES DEPARTMENT, (561) | | | 822-2062 OR [email protected]. | | | | | | 6. WPB ORD. SEC. 90 - 126 - THE DISCHARGE FROM AIR | | | HANDLERS/AIR CONDITIONING CONDENSATE CANNOT DISCHARGE | | | INTO THE SANITARY. IT MUST GO TO THE STORM OR OTHER | | | APPROVED PLACE OF DISPOSAL. | | | | | | 7. 2020 FPC 419.5/607.1.2 - PLEASE INCLUDE A DETAIL | | | SHOWING COMPLIANCE WITH THE REQUIREMENTS FOR TEMPERED | | | WATER FOR PUBLIC HANDWASHING STATIONS THAT INCLUDES THE | | | LIMITING DEVICE THAT CONFORMS TO ASSE 1070. | | | | | | | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
13 |
Status |
P |
Date |
2023-07-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-14 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-14 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
12 |
Status |
P |
Date |
2023-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-11 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-11 |
Time |
15:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
11 |
Status |
P |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-26 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-26 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
10 |
Status |
P |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-20 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-20 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
9 |
Status |
P |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-26 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-26 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
8 |
Status |
P |
Date |
2023-05-10 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-10 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-10 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
7 |
Status |
P |
Date |
2023-04-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-04-03 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-03 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
P |
Date |
2023-03-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-07 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-07 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
F |
Date |
2023-02-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-16 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-16 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2023-02-16 15:17:07 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWINGS S-002, S-003, P-901, P-902, P-903, P-904, | | | P-002, P-101, P-102, P-103, P-104, P-201, P-501, P-502 | | | DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2023-01-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-20 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-20 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2023-01-20 13:31:23 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) SIGNED AND SEALED DRAWINGS SUCH AS STRUCTURAL, FIRE | | | PROTECTION AND THE SPECIAL INSPECTOR FORM DO NOT SHOW | | | AS DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-12-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-12-05 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-12-05 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2022-12-05 14:18:17 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) SIGNED AND SEALED DRAWINGS SUCH AS STRUCTURAL, FIRE | | | PROTECTION, ELECTRICAL, PLUMBING, MECHANICAL AND THE | | | SPECIAL INSPECTOR FORM DO NOT SHOW AS DIGITALLY SIGNED | | | IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | | | 2022-11-30 09:23:24 | MECHANICAL DIGITAL SIGNATURE REVIEW FAILED. THE | | | SIGNATURE IS A COPY OF THE ORIGINAL DIGITAL SIGNATURE. | | | ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-10-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-10-07 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-10-07 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2022-10-07 09:37:06 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) STRUCTURAL AND FIRE PROTECTION DRAWINGS DO NOT SHOW | | | AS DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-08-04 |
Time |
06:21 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-08-04 |
Time |
06:21 |
Sent To |
|
|
| Notes |
| 2022-08-04 06:22:04 | MULITPLE PAGES NOT SIGNED/SEALED | | | | | | ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR | | | ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH | | | 61G1-16 AND 61G15, F.A.C | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | 2022-07-18 15:01:09 | THE MECHANICAL DRAWINGS WILL NEED TO BE DIGITALLYSIGNED | | | BY THE EOR. FS 471/481 | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2023-02-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-16 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-16 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2023-01-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-01-05 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-05 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
12 |
Status |
P |
Date |
2023-07-13 |
|
|
Cont ID |
|
| Sent By |
cibaven |
Date |
2023-07-13 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
cibaven |
Date |
2023-07-13 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2023-07-13 16:45:02 | PROVISO: | | | THE PERMIT NEEDS TO BE REVISED BEFORE INSPECTIONS. ALL | | | FLOOR PLANS SHOWING ON ELECTRICAL, PLUMBING, | | | FOUNDATION, AND ALL DRAWINGS ARE REQUIRED TO BE UPDATED | | | AND MATCH APPROVED FLOOR PLANS OUTLINED IN THE SITE | | | PLAN APPROVAL LETTER FOR FSPR CASE NO. 22-24. | | | | | | IN ADDITION, THE FOLLOWING CONDITIONS WILL ALSO NEED TO | | | BE ADDRESSED: | | | | | | 1. PRIOR ISSUANCE OF THE TEMPORARY CERTIFICATE OF | | | OCCUPANCY, A REVISED TPS LETTER WILL NEED TO BE | | | SUBMITTED TO THE PLANNING DIVISION. | | | | | | 2. PRIOR TO ISSUANCE OF THE TEMPORARY CERTIFICATE OF | | | OCCUPANCY, AN AERIAL EASEMENT AGREEMENT WILL BE | | | FINALIZED. | | | | | | 3. PRIOR TO ISSUANCE OF THEIR BUILDING PERMIT: THIS | | | DEVELOPMENT IS SUBJECT TO THE PUBLIC ART REQUIREMENT, | | | HOWEVER THE 1% IS MINIMAL. THEY DO NEED TO COMPLETE AN | | | ART ASSESSMENT APPLICATION, SELECT OPTION#2 | | | CONTRIBUTION INTO THE ART FUND, WHICH MUST BE | | | COMPLETED, AND PAID BEFORE, OR AT TIME OF BUILDING | | | PERMIT FEES. | | | | | | 4. THE GARBAGE CONTAINERS SHALL BE FRONT-LOAD TYPE TO | | | BE COMPATIBLE WITH THE CITY'S SANITATION COLLECTION | | | VEHICLES. | | | | | | 5. ALL POOL DISCHARGE MIST BE DECHLORINATED PRIOR TO | | | ENTERING THE CITY'S STORMWATER DRAINAGE SYSTEM. NO POOL | | | DISCHARGE MAY ENTER THE CITY'S SANITARY SYSTEM. | | | | | | 6. NEW AND EXISTING ROOF DRAIN LEADERS ARE TO BE | | | DIRECTLY CONNECTED TO THE DRAINAGE SYSTEM IN THE ALLEY. | | | NO OPEN CONNECTIONS TO THE ALLEY SURFACE. | | | | | | 7. ANY WORK WITHIN THE PUBLIC RIGHT OF WAY (ALLEY, | | | CLEMATIS ST.) WILL REQUIRE AN ENGINEERING PERMIT. | | | | | | 8. A RIGHT-OF-WAY (ROW) PERMIT IS REQUIRED. | | | | | | 9. THE APPLICANT WILL COORDINATE WITH THE PARKING | | | DEPARTMENT AND WILL COPY THE ENGINEERING DEPARTMENT IN | | | THE CORRESPONDENCE, WITH THE RESPECT TO THE IMPACTED | | | PARKING STALLS WITHIN THE 300 BLOCK. | | | | | | 10. THE DEVELOPER SHALL BE RESPONSIBLE FOR ANY | | | INFRASTRUCTURE IMPROVEMENTS REQUIRED TO SERVE THE | | | PROJECT. | | | | | | 11. ANY REQUIRED EASEMENTS (I.E. DRAINAGE, UTILITIES, | | | PUBLIC ACCESS, OUTFALL, ETC.) SHALL BE PROVIDED VIA | | | PLAT OR SEPARATE LEGAL INSTRUMENT. | | | | | | 12. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 13. UPON APPLICATION FOR A BUILDING PERMIT, THE | | | DEVELOPER SHALL SUBMIT TO THE CITY A CONSTRUCTION | | | PARKING MANAGEMENT PLAN PER THE PROVISIONS OF CHAPTER | | | 86, ARTICLE IV, DIVISION 1, SEC. 86-245 OF THE CITY'S | | | CODE OF ORDINANCES. | | | | | | 14. ALL CONDITIONS OF APPROVAL INCLUDED IN THE DAC | | | FINAL ORDER FOR FSPR 22-24 APPROVED BY THE COMMITTEE ON | | | MAY 10, 2023, ARE PART OF THIS SITE PLAN APPROVAL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
11 |
Status |
P |
Date |
2023-06-28 |
|
|
Cont ID |
|
| Sent By |
cibaven |
Date |
2023-06-28 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
cibaven |
Date |
2023-06-28 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2023-06-28 17:11:18 | PROVISO: | | | THE PERMIT NEEDS TO BE REVISED BEFORE INSPECTIONS. ALL | | | FLOOR PLANS SHOWING ON ELECTRICAL, PLUMBING, | | | FOUNDATION, AND ALL DRAWINGS ARE REQUIRED TO BE UPDATED | | | AND MATCH APPROVED FLOOR PLANS OUTLINED IN THE SITE | | | PLAN APPROVAL LETTER FOR FSPR CASE NO. 22-24. | | | | | | IN ADDITION, THE FOLLOWING CONDITIONS WILL ALSO NEED TO | | | BE ADDRESSED: | | | | | | 1. PRIOR ISSUANCE OF THE TEMPORARY CERTIFICATE OF | | | OCCUPANCY, A REVISED TPS LETTER WILL NEED TO BE | | | SUBMITTED TO THE PLANNING DIVISION. | | | | | | 2. PRIOR TO ISSUANCE OF THE TEMPORARY CERTIFICATE OF | | | OCCUPANCY, AN AERIAL EASEMENT AGREEMENT WILL BE | | | FINALIZED. | | | | | | 3. PRIOR TO ISSUANCE OF THEIR BUILDING PERMIT: THIS | | | DEVELOPMENT IS SUBJECT TO THE PUBLIC ART REQUIREMENT, | | | HOWEVER THE 1% IS MINIMAL. THEY DO NEED TO COMPLETE AN | | | ART ASSESSMENT APPLICATION, SELECT OPTION#2 | | | CONTRIBUTION INTO THE ART FUND, WHICH MUST BE | | | COMPLETED, AND PAID BEFORE, OR AT TIME OF BUILDING | | | PERMIT FEES. | | | | | | 4. THE GARBAGE CONTAINERS SHALL BE FRONT-LOAD TYPE TO | | | BE COMPATIBLE WITH THE CITY???S SANITATION COLLECTION | | | VEHICLES. | | | | | | 5. ALL POOL DISCHARGE MIST BE DECHLORINATED PRIOR TO | | | ENTERING THE CITY???S STORMWATER DRAINAGE SYSTEM. NO | | | POOL DISCHARGE MAY ENTER THE CITY???S SANITARY SYSTEM. | | | | | | 6. NEW AND EXISTING ROOF DRAIN LEADERS ARE TO BE | | | DIRECTLY CONNECTED TO THE DRAINAGE SYSTEM IN THE ALLEY. | | | NO OPEN CONNECTIONS TO THE ALLEY SURFACE. | | | | | | 7. ANY WORK WITHIN THE PUBLIC RIGHT OF WAY (ALLEY, | | | CLEMATIS ST.) WILL REQUIRE AN ENGINEERING PERMIT. | | | | | | 8. A RIGHT-OF-WAY (ROW) PERMIT IS REQUIRED. | | | | | | 9. THE APPLICANT WILL COORDINATE WITH THE PARKING | | | DEPARTMENT AND WILL COPY THE ENGINEERING DEPARTMENT IN | | | THE CORRESPONDENCE, WITH THE RESPECT TO THE IMPACTED | | | PARKING STALLS WITHIN THE 300 BLOCK. | | | | | | 10. THE DEVELOPER SHALL BE RESPONSIBLE FOR ANY | | | INFRASTRUCTURE IMPROVEMENTS REQUIRED TO SERVE THE | | | PROJECT. | | | | | | 11. ANY REQUIRED EASEMENTS (I.E. DRAINAGE, UTILITIES, | | | PUBLIC ACCESS, OUTFALL, ETC.) SHALL BE PROVIDED VIA | | | PLAT OR SEPARATE LEGAL INSTRUMENT. | | | | | | 12. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 13. UPON APPLICATION FOR A BUILDING PERMIT, THE | | | DEVELOPER SHALL SUBMIT TO THE CITY A CONSTRUCTION | | | PARKING MANAGEMENT PLAN PER THE PROVISIONS OF CHAPTER | | | 86 ??? ARTICLE IV ??? DIVISION 1 ??? SEC. 86-245 OF THE | | | CITY???S CODE OF ORDINANCES. | | | | | | 14. ALL CONDITIONS OF APPROVAL INCLUDED IN THE DAC | | | FINAL ORDER FOR FSPR 22-24 APPROVED BY THE COMMITTEE ON | | | MAY 10, 2023, ARE PART OF THIS SITE PLAN APPROVAL. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
10 |
Status |
F |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
cibaven |
Date |
2023-06-20 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
cibaven |
Date |
2023-06-20 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2023-06-20 17:19:14 | PLANS DO NOT MATCH APPROVED SET OF PLANS REFERENCE ON | | | THE SITE PLAN APPOVAL LETTER, FOR THE FORMAL SITE PLAN | | | REVIEW CASE NO. 22-24 (Z22120027)- 309/613 CLEMATIS | | | STREET, ISSUED ON JUNE 12, 2023. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
9 |
Status |
F |
Date |
2023-06-12 |
|
|
Cont ID |
|
| Sent By |
cibaven |
Date |
2023-06-12 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
cibaven |
Date |
2023-06-12 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2023-06-12 15:53:13 | PLANS DO NOT MATCH APPROVED SET OF PLANS REFERENCE ON | | | THE SITE PLAN APPOVAL LETTER, FOR THE FORMAL SITE PLAN | | | REVIEW CASE NO. 22-24 (Z22120027)- 309/613 CLEMATIS | | | STREET, ISSUED ON JUNE 12, 2023. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
8 |
Status |
F |
Date |
2023-05-12 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2023-05-12 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2023-05-12 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2023-05-12 08:54:23 | PROJECT NEEDS SITE PLAN APPROVAL BEFORE BUILDING | | | PERMITS CAN BE REVIEWED AND APPROVED. APPLICATION FSPR | | | 22-24 (Z22120027) IS IN REVIEW. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
7 |
Status |
F |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
cibaven |
Date |
2023-04-26 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
cibaven |
Date |
2023-04-26 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2023-04-26 08:57:20 | PROJECT NEEDS SITE PLAN APPROVAL BEFORE BUILDING | | | PERMITS CAN BE REVIEWED AND APPROVED. APPLICATION FSPR | | | 22-24 (Z22120027) IS IN REVIEW. | | | | | | CLAUDIA IBAVEN, CITY URBAN DESIGNER | | | PLANNING DIVISION | | | [email protected] | | | 516-822-1402 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
F |
Date |
2023-03-24 |
|
|
Cont ID |
|
| Sent By |
cibaven |
Date |
2023-03-24 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
cibaven |
Date |
2023-03-24 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2023-03-24 17:10:26 | PROJECT NEEDS SITE PLAN APPROVAL BEFORE BUILDING | | | PERMITS CAN BE REVIEWED AND APPROVED. APPLICATION FSPR | | | 22-24 (Z22120027) IS IN REVIEW. | | | | | | CLAUDIA IBAVEN, CITY URBAN DESIGNER | | | PLANNING DIVISION | | | [email protected] | | | 516-822-1402 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
cibaven |
Date |
2023-02-27 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
cibaven |
Date |
2023-02-27 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2023-02-27 16:56:02 | PROJEC NEEDS SITE PLAN APPROVAL BEFORE PERMITS CAN BE | | | APPROVED. APPLICATION FSPR 22-24 (Z22120027) IN REVIEW. | | | | | | CLAUDIA D. IBAVEN | | | CITY URBAN DESIGNER | | | [email protected], 561-822-1402 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2023-02-08 |
|
|
Cont ID |
|
| Sent By |
cibaven |
Date |
2023-02-08 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
cibaven |
Date |
2023-02-08 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2023-02-08 10:21:52 | PROJECTS NEED SITE PLAN APPROVAL BEFORE PERMITS CAN BE | | | APPROVED. APPLICATION FSPR 22-24 (Z22120027) IN REVIEW. | | | | | | CLAUDIA D. IBAVEN | | | CITY URBAN DESIGNER | | | [email protected], 561-822-1402 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2022-12-08 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-12-08 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-12-08 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2022-12-08 09:46:54 | REPEAT COMMENT: | | | | | | 1. PROPOSED PROJECT TRIGGERS REQUIREMENTS FOR A FORMAL | | | SITE PLAN REVIEW. PLEASE SUBMIT AN 2022 DOWNTOWN MASTER | | | PLAN (DMP) DEVELOPMENT APPLICATION. | | | | | | - PERMIT ADDS MORE THAN 1000 GROSS SF BETWEEN FLOOR | | | ADDITIONS, BATHROOM SPACES, AND BAR/RESTAURANT | | | AMENITIES. | | | - PERMIT INVOLVES IMPROVEMENTS AND ALTERATIONS TO MORE | | | THAN ONE PROPERTY, BOTH 313 AND 309 CLEMATIS. | | | - SCOPE OF WORK WITHIN THE PERMIT APPEARS TO INCLUDE | | | THE REQUEST FOR VARIANCES FROM ESTABLISHED SETBACKS. | | | | | | WILL REQUIRE PLANS PLATS & REVIEW COMMITTEE ASSESSMENT, | | | AND WILL BE SUBJECT TO DOWNTOWN ACTION COMMITTEE | | | SPECIAL REVIEW AND VARIANCE APPROVAL. | | | | | | CHRIS KIMMERLY, AICP | | | URBAN DESIGN PLANNER | | | 822.1426 [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-11-07 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-11-07 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-11-07 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2022-11-07 11:45:41 | REPEAT COMMENT: | | | | | | 1. PROPOSED PROJECT TRIGGERS REQUIREMENTS FOR A FORMAL | | | SITE PLAN REVIEW. PLEASE SUBMIT AN 2022 DOWNTOWN MASTER | | | PLAN (DMP) DEVELOPMENT APPLICATION. | | | | | | - PERMIT ADDS MORE THAN 1000 GROSS SF BETWEEN FLOOR | | | ADDITIONS, BATHROOM SPACES, AND BAR/RESTAURANT | | | AMENITIES. | | | - PERMIT INVOLVES IMPROVEMENTS AND ALTERATIONS TO MORE | | | THAN ONE PROPERTY, BOTH 313 AND 309 CLEMATIS. | | | - SCOPE OF WORK WITHIN THE PERMIT APPEARS TO INCLUDE | | | THE REQUEST FOR VARIANCES FROM ESTABLISHED SETBACKS. | | | | | | WILL REQUIRE PLANS PLATS & REVIEW COMMITTEE ASSESSMENT, | | | AND WILL BE SUBJECT TO DOWNTOWN ACTION COMMITTEE | | | SPECIAL REVIEW AND VARIANCE APPROVAL. | | | | | | CHRIS KIMMERLY, AICP | | | URBAN DESIGN PLANNER | | | 822.1426 [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-08-22 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-08-22 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2022-08-22 14:47:01 | 1. PROPOSED PROJECT TRIGGERS REQUIREMENTS FOR A FORMAL | | | SITE PLAN REVIEW. PLEASE SUBMIT AN 2022 DOWNTOWN MASTER | | | PLAN (DMP) DEVELOPMENT APPLICATION. | | | | | | - PERMIT ADDS MORE THAN 1000 GROSS SF BETWEEN FLOOR | | | ADDITIONS, BATHROOM SPACES, AND BAR/RESTAURANT | | | AMENITIES. | | | - PERMIT INVOLVES IMPROVEMENTS AND ALTERATIONS TO MORE | | | THAN ONE PROPERTY, BOTH 313 AND 309 CLEMATIS. | | | - SCOPE OF WORK WITHIN THE PERMIT APPEARS TO INCLUDE | | | THE REQUEST FOR VARIANCES FROM ESTABLISHED SETBACKS. | | | | | | WILL REQUIRE PLANS PLATS & REVIEW COMMITTEE ASSESSMENT, | | | AND WILL BE SUBJECT TO DOWNTOWN ACTION COMMITTEE | | | SPECIAL REVIEW AND VARIANCE APPROVAL. | | | | | | CHRIS KIMMERLY, AICP | | | URBAN DESIGN PLANNER | | | 822.1426 [email protected] |
|
|