Plan Review Details - Permit 22061092
Plan Review Stops For Permit 22061092
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2022-11-30 Cont ID  
Sent By cpuell Date 2022-11-30 Time 12:18 Rev Time 0.00
Received By cpuell Date 2022-11-30 Time 12:18 Sent To  
Notes
2022-11-30 12:19:04SPOKE WITH APPLICANT THEY WILL BE DOING PERMITS UNDER
 THE SEPARATE PARCELS, THIS PERMIT IS FOR 309 CLEMATIS
 ST ONLY

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2022-09-29 Cont ID  
Sent By cpuell Date 2022-09-29 Time 08:40 Rev Time 0.00
Received By cpuell Date 2022-09-29 Time 08:40 Sent To  
Notes
2022-09-29 08:40:58PREVIOUS COMMENTS NOT ADDRESSED

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-09-01 Cont ID  
Sent By cpuell Date 2022-09-01 Time 16:28 Rev Time 0.00
Received By cpuell Date 2022-09-01 Time 16:28 Sent To  
Notes
2022-09-01 16:31:07PLANS PLANS REFRENCING BUILDINGS 309 311 AND 313
 CLEMATIS ST. 311 CLEMATIS STREET IS NOT A CURRENT
 ADDRESS AND 313 CLEMATIS ST IS ON A SEPARATE PARCEL.
 PLEASE CONTACT [email protected] OR CALL
 561-805-6659 TO DISCUSS ADDRESSING ISSUES.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status N Date 2022-12-05 Cont ID  
Sent By rmcphers Date 2022-12-05 Time 13:25 Rev Time 0.00
Received By rmcphers Date 2022-12-05 Time 13:25 Sent To  
Notes
2022-12-05 13:25:44SEE DEMO PERMITS
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-10-07 Cont ID  
Sent By rmcphers Date 2022-10-07 Time 09:53 Rev Time 0.00
Received By rmcphers Date 2022-10-07 Time 09:53 Sent To  
Notes
2022-10-07 09:53:54PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-09-02 Cont ID  
Sent By rmcphers Date 2022-09-02 Time 08:24 Rev Time 0.00
Received By rmcphers Date 2022-09-01 Time 09:00 Sent To  
Notes
2022-09-02 08:25:45PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 11 Status P Date 2023-07-14 Cont ID  
Sent By rmcphers Date 2023-07-14 Time 08:43 Rev Time 0.00
Received By rmcphers Date 2023-07-14 Time 08:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status F Date 2023-07-11 Cont ID  
Sent By rmcphers Date 2023-07-11 Time 15:25 Rev Time 0.00
Received By rmcphers Date 2023-07-11 Time 14:30 Sent To  
Notes
2023-07-11 15:25:34REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A-204 WAS REVISED AND THE NOTE FOR THE
 ACCESSIBLE POOL ENTRY WAS REMOVED - PLEASE SHOW THE
 ACCESSIBLE POOL ENTRY - FBC A 242.2
 YOU CAN ADD "ACCESSIBLE POOL LIFT" TO THE DEFERRED
 SUBMITTALS LIST ON DRAWING CVR
  
 2) NOA 20-1130.10 HAS BEEN SUBMITTED FOR THE ROLL UP
 DOOR (MARKED D8 ON THE DRAWING) - PLEASE SHOW HOW THIS
 DOOR IS SELF CLOSING PER FBC 716.5.9 DOOR CLOSING. FIRE
 DOORS SHALL BE LATCHING AND SELF- OR AUTOMATIC-CLOSING
 IN ACCORDANCE WITH THIS SECTION.
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status F Date 2023-06-26 Cont ID  
Sent By rmcphers Date 2023-06-26 Time 14:44 Rev Time 0.00
Received By rmcphers Date 2023-06-26 Time 13:55 Sent To  
Notes
2023-06-26 14:24:18REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A-201 HAS A STATEMENT THAT A 90 MIN. FIRE
 RATED DOOR IS REQUIRED - PLEASE SHOW THE LOCATION OF
 THIS 90 MIN. FIRE RATED DOOR.
  
 2) DOOR D8 SHOULD BE FIRE RATED - FBC TABLE 716.5 -
 BASED ON THE EXTERIOR WALL RATING FBC TABLE 705.8
  
 3) DOOR SCHEDULE NEEDS TO SHOW THE DOOR FIRE RATINGS -
 FBC TABLE 716.5
  
 4) PLEASE SHOW THE FIRE RATED DOORS TO BE SELF CLOSING
 - FBC 716.5.9
  
 5) PLEASE SHOW THE ACCESSIBLE SEATING AREA FOR THE
 TABLES AND BAR ON THE GROUND FLOOR REMODEL (309) - FBC
 A 226.2
  
 6) PLEASE SHOW THE ACCESSIBLE POOL ENTRY - FBC A 242.2
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status F Date 2023-06-20 Cont ID  
Sent By rmcphers Date 2023-06-20 Time 12:55 Rev Time 0.00
Received By rmcphers Date 2023-06-20 Time 12:55 Sent To  
Notes
2023-06-20 13:40:46REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A102 FAR DRAWINGS OVERLAID THE DRAWING A102
 THE ROOF DECK LIFE SAFETY PLAN IN PROJECTDOX - PLEASE
 CORRECT
  
 2) DRAWING A101 ACTIVE USE DRAWING OVERLAID THE DRAWING
 A101 THE GROUND FLOOR LIFE SAFETY PLAN IN PROJECTDOX -
 PLEASE CORRECT
  
 3) DRAWING A201 AND A101 NEED TO MATCH THE REVISED
 FLOOR PLAN AS SHOWN ON DRAWING (A101 ACTIVE USE PLAN).
  
 4) SHOW THE DOOR SIZES (OVERHEAD DOOR ETC.) I DO NOT
 SEE A DOOR SCHEDULE IN PROJECTDOX - FBC 107.2
  
 5) PLEASE SHOW THE REAR TRASH ROOM DOOR TYPE,SIZE AND
 OPENING DIRECTION - FBC 107.2

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2023-04-03 Cont ID  
Sent By rmcphers Date 2023-04-03 Time 08:51 Rev Time 0.00
Received By rmcphers Date 2023-04-03 Time 08:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2023-03-07 Cont ID  
Sent By rmcphers Date 2023-03-07 Time 09:48 Rev Time 0.00
Received By rmcphers Date 2023-03-07 Time 09:48 Sent To  
Notes
2023-03-07 09:50:24ADDITION AND REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) THE SLIDING ROOF DRAWINGS AND CALCULATIONS SHOW WIND
 DESIGN USING WIND SPEED OF 170MPH = BUILDING IS A RISK
 CATEGORY III - WIND DESIGN NEEDS TO BE BASED ON 180 MPH
 PER FBC WPB SECTION 120
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2023-02-16 Cont ID  
Sent By rmcphers Date 2023-02-16 Time 14:13 Rev Time 0.00
Received By rmcphers Date 2023-02-16 Time 14:13 Sent To  
Notes
2023-02-16 14:14:45ADDITION AND REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) BUILDING IS A RISK CATEGORY III - WIND DESIGN NEEDS
 TO BE BASED ON 180 MPH PER FBC WPB SECTION 120
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2023-01-20 Cont ID  
Sent By rmcphers Date 2023-01-20 Time 13:30 Rev Time 0.00
Received By rmcphers Date 2023-01-20 Time 13:25 Sent To  
Notes
2023-01-20 13:30:01ADDITION AND REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A201 AND A101 THE FLOOR PLAN SHOULD MATCH
 (VESTIBULE WALL CHANGES). FBC WPB 107
  
 2) THE SIGNED AND SEALED STRUCTURAL DRAWINGS AND THE
 SIGNED AND SEALED THRESHOLD INSPECTOR FORM DO NOT SHOW
 AS DIGITALLY SIGNED IN ADOBE READER - SIGNED AND SEALED
 DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  
 3) NEW DOORS AT THE FRONT OF THE BUILDING SHOULD NOT
 ENCROACH IN TO THE PUBLIC RIGHT OF WAY FBC 3202.2
 ENCROACHMENTS ABOVE GRADE AND BELOW 8 FEET IN HEIGHT.
 DOORS AND WINDOWS SHALL NOT OPEN OR PROJECT INTO THE
 PUBLIC RIGHT-OF-WAY.
  
 4) BUILDING IS A RISK CATEGORY III - WIND DESIGN NEEDS
 TO BE BASED ON 180 MPH PER FBC WPB SECTION 120
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-12-05 Cont ID  
Sent By rmcphers Date 2022-12-05 Time 13:27 Rev Time 0.00
Received By rmcphers Date 2022-12-05 Time 13:27 Sent To  
Notes
2022-12-05 13:50:09ADDITION AND REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A201 SHOWS EXTERIOR WALL OPENING
 CALCULATIONS - THE REAR WALL WHICH IS 9' 8" FROM THE
 CENTER OF THE ALLEY HAS A DOOR OPENING WHICH IS NOT
 SHOWN ON THE OPENING CALCULATIONS. - FBC TABLE 705.8
  
 2) THE SIGNED AND SEALED STRUCTURAL DRAWINGS AND THE
 SIGNED AND SEALED THRESHOLD INSPECTOR FORM DO NOT SHOW
 AS DIGITALLY SIGNED IN ADOBE READER - SIGNED AND SEALED
 DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  
 3) NEW DOORS AT THE FRONT OF THE BUILDING SHOULD NOT
 ENCROACH IN TO THE PUBLIC RIGHT OF WAY FBC 3202.2 -
 PLEASE PROVIDE A SURVEY
  
 4) CANNOT HAVE AN ELEVATOR IN A STAIR EXIT VESTIBULE -
 FBC 1028.1 EXCEPTION 2 - 2.4.THE AREA IS USED ONLY FOR
 MEANS OF EGRESS AND EXITS DIRECTLY TO THE OUTSIDE.
  
 5) BUILDING IS A RISK CATEGORY III - WIND DESIGN NEEDS
 TO BE BASED ON 180 MPH PER FBC WPB SECTION 120
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-10-07 Cont ID  
Sent By rmcphers Date 2022-10-07 Time 09:44 Rev Time 0.00
Received By rmcphers Date 2022-10-07 Time 08:15 Sent To  
Notes
2022-10-07 08:57:28ADDITION AND REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE NEW EXTERIOR WINDOWS, DOORS
 AND ROOFING SYSTEMS - ALL PRODUCT APPROVALS NEED TO BE
 REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER
 OF RECORD FBC WPB 107.3.4
  
 2) PLEASE SHOW ON THE DRAWINGS THAT TERMITE TREATMENT
 IS A REQUIREMENT PER FBC 1816
  
 3) PLEASE SHOW WALL DESIGNATIONS ON THE FLOOR PLANS -
 SHOW FIRE WALLS ETC. FBC WPB 107.2
  
 4) BASED ON THE DISTANCE FROM THE CENTER OF THE ALLY
 (SHOW THE DISTANCE) TO THE REAR WALL. THE REAR WALL
 NEEDS TO SHOW AS 1 HOUR FIRE RATED - FBC TABLE 602
  
 5) BASED ON THE DISTANCE FROM THE CENTER OF THE ALLY
 (SHOW THE DISTANCE) TO THE REAR WALL - PLEASE SHOW THE
 ALLOWABLE NON PROTECTED OR PROTECTED OPENING
 CALCULATIONS FOR EACH FLOOR - FBC TABLE 705.8
  
 6) PLEASE SHOW THE POOL BARRIER (DOORS, LOCKS, LATCH
 HEIGHT ETC.) AT THE STAIR AND ELEVATOR DOORS TO COMPLY
 WITH FBC 454.1.3.1.9
  
 7) PLEASE SHOW THE ACCESSIBLE POOL ENTRY - FBC A 242.2
 SWIMMING POOLS.
 AT LEAST TWO ACCESSIBLE MEANS OF ENTRY SHALL BE
 PROVIDED FOR SWIMMING POOLS. ACCESSIBLE MEANS OF ENTRY
 SHALL BE SWIMMING POOL LIFTS COMPLYING WITH 1009.2;
 SLOPED ENTRIES COMPLYING WITH 1009.3; TRANSFER WALLS
 COMPLYING WITH 1009.4; TRANSFER SYSTEMS COMPLYING WITH
 1009.5; AND POOL STAIRS COMPLYING WITH 1009.6. AT LEAST
 ONE ACCESSIBLE MEANS OF ENTRY PROVIDED SHALL COMPLY
 WITH 1009.2 OR 1009.3.
  
 8) FOR THE REMODELED GROUND FLOOR = PLEASE SHOW THE
 DIFFERENT DINING AREA LOCATIONS FOR THE ACCESSIBLE
 SEATING - FBC 226
  
 9) FOR THE REMODELED GROUND FLOOR = PLEASE SHOW AT
 LEAST 1 ACCESSIBLE SEAT AT EACH BAR LOCATION (SHOW
 COUNTER HEIGHT, KNEE AND TOE CLEARANCES ETC. ) - FBC
 226.2
  
 10) PLEASE PROVIDE TYPICAL GUARDRAIL AND HANDRAIL
 DETAILS - SHOWING HEIGHTS, OPENING SPECS., HANDRAIL
 EXTENSIONS ETC. FBC 1014 AND 1015
  
 11) PLEASE PROVIDE A THRESHOLD INSPECTION PLAN - FBC
 (CITY AMENDMENTS)110.8.1 THRESHOLD INSPECTION PLAN. THE
 ENFORCING AGENCY SHALL REQUIRE A SPECIAL INSPECTOR TO
 PERFORM STRUCTURAL INSPECTIONS ON A THRESHOLD BUILDING
 PURSUANT TO A STRUCTURAL INSPECTION PLAN PREPARED BY
 THE ENGINEER OF RECORD.
  
 12) THE STRUCTURAL DRAWINGS NEED TO CONTAIN THIS NOTE -
 THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT
 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED
 TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF
 RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE
 ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND
 SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM
 BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS
 AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH
 THIS SECTION AND CHAPTER 633 FLORIDA STATUTES.
  
 13) PLEASE READ AND FILL OUT THE REQUIRED DOCUMENTS PER
 THE "GUIDELINES AND POLICIES FOR PROJECTS CONCERNING
 THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS".
 YOU CAN E MAIL ME AND ASK FOR A COPY.
  
 14) PLEASE PROVIDE A COPY OF THE UNITY OF TITLE.
  
 15) A SEPARATE PERMIT IS REQUIRED FOR THE BUILDING
 DEMO.
  
 16) ITEMS SUCH AS BUT NOT LIMITED TO RAILING, EXTERIOR
 WINDOW, DOOR AND ROOFING SYSTEMS PRODUCT APPROVALS MAY
 BE DEFERRED SUBMITTALS BY LISTING ITEMS TO BE DEFERRED
 ON THE CONSTRUCTION DOCUMENTS - FBC WPB 107.3.4.1
 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION,
 DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF
 THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE
 APPLICATION AND THAT ARE TO BE SUBMITTED TO THE
 BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL
 OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF
 THE BUILDING OFFICIAL. THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE
 DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR
 REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED
 SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL
 REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL
 WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL
 DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL
 CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED
 SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE
 BUILDING OFFICIAL.
  
 17) STRUCTURAL AND FIRE PROTECTION DRAWINGS DO NOT SHOW
 AS DIGITALLY SIGNED IN ADOBE READER - SIGNED AND SEALED
 DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-02 Cont ID  
Sent By rmcphers Date 2022-09-02 Time 08:30 Rev Time 0.00
Received By rmcphers Date 2022-09-01 Time 09:00 Sent To  
Notes
2022-09-01 15:55:02ADDITION AND REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A303 - RESTROOM DOOR NEAR THE REAR STAIR
 APPEARS TO SWING IN THE EGRESS PATH - FBC 1005.7.1
 DOORS.
 DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED
 WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY
 POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE
 THAN ONE-HALF.
  
 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE NEW EXTERIOR WINDOWS, DOORS
 AND ROOFING SYSTEMS - ALL PRODUCT APPROVALS NEED TO BE
 REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER
 OF RECORD FBC WPB 107.3.4
  
 3) DRAWING A 403 - ELEVATIONS ARE NOT LABELED CORRECTLY
 (BOTH ARE LABELED EXISTING).
  
 4) DRAWING A 201 - PLEASE SHOW THE USE FOR EACH ROOM OR
 SPACE.
  
 5) PLEASE SHOW THAT TERMITE TREATMENT IS A REQUIREMENT
 PER FBC 1816
  
 6) DRAWING A 501 - SHOW THE CEILING HEIGHT FOR THE
 EGRESS CATWALK AT STAIRS - FBC 1003.2
  
 7) DRAWING A 604 - GAZEBO WALL DETAIL - WHAT IS (W-4H
 AND W-4B) ?
  
 8) PLEASE SHOW ALL CEILING HEIGHTS (OFFICE, STORAGE
 ETC.) - FBC 1208.2
  
 9) DRAWING A 102 - UNDER OCCUPANCY LOAD I DO NOT SEE
 THE POOL AREA OCCUPANT LOAD - PLEASE PROVIDE BUILDING
 AREA SQUARE FOOTAGES.
  
 10) PLEASE PROVIDE A BUILDING SPRINKLER LAYOUT PLAN -
 FBC 903.2.1
  
 11) PLEASE SHOW THE LOCATION FOR THE OCCUPANT LOAD SIGN
 PER FBC 1004.9
  
 12) ON DRAWING A 101 IN THE "BUILDING CODE ANALYSIS"
 CHART PLEASE DESCRIBE THE BUILDING SEPARATION FROM THE
 ADJOINING BUILDINGS - FBC 508 NON-SEPARATED, SEPARATED
 - SHOW THE WALL SEPARATION TYPE - FIRE BARRIER FBC
 707.3.9 OR FIRE WALL FBC 706 - SHOW THE OCCUPANCY
 CLASSIFICATION FOR THE ADJOINING UNITS OR BUILDINGS FBC
 CHAPTER 3.
  
 13) PLEASE SHOW WALL DESIGNATIONS ON THE FLOOR PLANS -
 SHOW FIRE WALLS ETC. FBC WPB 107.2
  
 14) THE REAR WALL NEEDS TO SHOW AS 1 HOUR FIRE RATED -
 FBC TABLE 602
  
 15) BASED ON THE DISTANCE FROM THE CENTER OF THE ALLY
 TO THE REAR WALL OPENINGS - PLEASE SHOW THE ALLOWABLE
 NON PROTECTED OPENING CALCULATIONS - FBC TABLE 705.8
  
 16) PLEASE SHOW THE POOL BARRIER (DOORS, LOCKS, LATCH
 HEIGHT ETC.) AT THE STAIR AND ELEVATOR DOORS TO COMPLY
 WITH FBC 454.1.3.1.9
  
 17) PLEASE SHOW THE ACCESSIBLE POOL ENTRY - FBC A 242.2
 SWIMMING POOLS.
 AT LEAST TWO ACCESSIBLE MEANS OF ENTRY SHALL BE
 PROVIDED FOR SWIMMING POOLS. ACCESSIBLE MEANS OF ENTRY
 SHALL BE SWIMMING POOL LIFTS COMPLYING WITH 1009.2;
 SLOPED ENTRIES COMPLYING WITH 1009.3; TRANSFER WALLS
 COMPLYING WITH 1009.4; TRANSFER SYSTEMS COMPLYING WITH
 1009.5; AND POOL STAIRS COMPLYING WITH 1009.6. AT LEAST
 ONE ACCESSIBLE MEANS OF ENTRY PROVIDED SHALL COMPLY
 WITH 1009.2 OR 1009.3.
  
 18) PLEASE SHOW THE DIFFERENT DINING AREA LOCATIONS FOR
 THE ACCESSIBLE SEATING - FBC 226
  
 19) PLEASE SHOW AT LEAST 1 ACCESSIBLE SEAT AT EACH BAR
 LOCATION (SHOW COUTER HEIGHT, KNEE AND TOE CLEARANCES
 ETC. ) - FBC 226.2
  
 20) DRAWING A 603 - DETAIL P1, P2, P3 - THE MAX. 36
 INCHES FOR THE GRAB BAR HEIGHT SHOULD BE SHOWN TO THE
 TOP OF THE GRIPPING SURFACE FBC A 609.4
  
 21) THE MOVABLE ROOF SYSTEM ENGINEERING FROM "F AND M
 MAFCO" NEEDS TO BE SIGNED AND SEALED BY THE DESIGNER -
 FBC WPB 107.1
  
 22) THE MOVABLE ROOF SYSTEM ENGINEERING FROM "F AND M
 MAFCO" NEEDS TO BE REVIEWED AND MARKED APPROVED BY THE
 ENGINEER OF RECORD (LOADS MUST BE CHECKED BY THE
 ENGINEER OF RECORD AS NOTED ON THE RETRACTABLE ROOF
 DRAWING) FBC WPB 107.3.4
  
 23) PLEASE PROVIDE TYPICAL GUARDRAIL AND HANDRAIL
 DETAILS - SHOWING HEIGHTS, OPENING SPECS., HANDRAIL
 EXTENSIONS ETC. FBC 1014 AND 1015
  
 24) PLEASE PROVIDE A THRESHOLD INSPECTION PLAN - FBC
 (CITY AMENDMENTS)110.8.1 THRESHOLD INSPECTION PLAN. THE
 ENFORCING AGENCY SHALL REQUIRE A SPECIAL INSPECTOR TO
 PERFORM STRUCTURAL INSPECTIONS ON A THRESHOLD BUILDING
 PURSUANT TO A STRUCTURAL INSPECTION PLAN PREPARED BY
 THE ENGINEER OF RECORD.
  
 25) THE STRUCTURAL DRAWINGS NEED TO CONTAIN THIS NOTE -
 THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT
 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED
 TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF
 RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE
 ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND
 SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM
 BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS
 AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH
 THIS SECTION AND CHAPTER 633 FLORIDA STATUTES.
  
 26) PLEASE READ AND FILL OUT THE REQUIRED DOCUMENTS PER
 THE "GUIDELINES AND POLICIES FOR PROJECTS CONCERNING
 THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS".
 YOU CAN E MAIL ME AND ASK FOR A COPY.
  
 27) PLEASE PROVIDE A COPY OF THE UNITY OF TITLE.
  
 28) A SEPARATE PERMIT IS REQUIRED FOR THE BUILDING
 DEMO.
  
 29) ITEMS SUCH AS BUT NOT LIMITED TO EXTERIOR WINDOW,
 DOOR AND ROOFING SYSTEMS PRODUCT APPROVALS MAY BE
 DEFERRED SUBMITTALS BY LISTING ITEMS TO BE DEFERRED ON
 THE CONSTRUCTION DOCUMENTS - 107.3.4.1 DEFERRED
 SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, DEFERRED
 SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF THE DESIGN
 THAT ARE NOT SUBMITTED AT THE TIME OF THE APPLICATION
 AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL
 WITHIN A SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL
 ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING
 OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS
 ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE
 BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED SUBMITTAL
 ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW
 THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A
 NOTATION INDICATING THAT THE DEFERRED SUBMITTAL
 DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL
 CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED
 SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE
 BUILDING OFFICIAL.
  
  

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2023-01-27 Cont ID  
Sent By jleahy Date 2023-01-27 Time 08:48 Rev Time 0.00
Received By jleahy Date 2023-01-27 Time 08:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2022-12-09 Cont ID  
Sent By jleahy Date 2022-12-09 Time 08:18 Rev Time 0.00
Received By jleahy Date 2022-12-09 Time 07:32 Sent To  
Notes
2022-12-09 08:04:52FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) UNLESS YOU CAN PROVIDE DOCUMENTATION FOR FLOOR BOXES
 ON THE POOL DECK FLOOR, THAT THE OUTLETS WILL HAVE
 COVERS THAT ARE WEATHER PROOF WITH CORDS PLUGED IN
 PLEASE REMOVE ALL FLOOR OUTLETS IN THIS AREA.
 406.9(B)(1), 110.3(B)
  
 PLEASE INDICATE FOR ME WHAT TYPE OF DECKING IS TO BE
 USED AROUND THE POOL, CONCRETE, WOOD,
 COMPOSITE,ECT,ECT.)
  
 2) FANS IN THE POOL AREA, PLEASE SHOW ON THE PLAN THE
 HEIGHT AND DISTANCE FROM THE EDGE OF THE POOL TO THESE
 FANS. 680.22(B)(4)
  
 3) PAGE E104 SPEAKERS IN POOL OR ABOVE POOL? IF IN POOL
 PLEASE PROVIDE A LISTING FOR THE SPEAKERS. 110.3(BB)
  
 4) E-106 POOL EQUIPMENT CORROSIVE AREA?
  
 680.14 CORROSIVE ENVIRONMENT.
 (A) GENERAL.
 AREAS WHERE POOL SANITATION CHEMICALS ARE STORED, AS
 WELL AS AREAS WITH CIRCULATION PUMPS, AUTOMATIC
 CHLORINATORS, FILTERS, OPEN AREAS UNDER DECKS ADJACENT
 TO OR ABUTTING THE POOL STRUCTURE, AND SIMILAR
 LOCATIONS SHALL BE CONSIDERED TO BE A CORROSIVE
 ENVIRONMENT. THE AIR IN SUCH AREAS SHALL BE CONSIDERED
 TO BE LADEN WITH ACID, CHLORINE, AND BROMINE VAPORS, OR
 ANY COMBINATION OF ACID, CHLORINE, OR BROMINE VAPORS,
 AND ANY LIQUIDS OR CONDENSATION IN THOSE AREAS SHALL BE
 CONSIDERED TO BE LADEN WITH ACIDS, CHLORINE, AND
 BROMINE VAPORS, OR ANY COMBINATION OF ACID, CHLORINE,
 OR BROMINE VAPORS.
  
 (B) WIRING METHODS.
 WIRING METHODS IN THE AREAS DESCRIBED IN 680.14(A)
 SHALL BE LISTED AND IDENTIFIED FOR USE IN SUCH AREAS.
 RIGID METAL CONDUIT, INTERMEDIATE METAL CONDUIT, RIGID
 POLYVINYL CHLORIDE CONDUIT, AND REINFORCED
 THERMOSETTING RESIN CONDUIT SHALL BE CONSIDERED TO BE
 RESISTANT TO THE CORROSIVE ENVIRONMENT SPECIFIED IN
 680.14(A).

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2022-12-09 Cont ID  
Sent By jleahy Date 2022-12-09 Time 14:29 Rev Time 0.00
Received By jleahy Date 2022-12-08 Time 12:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2022-12-09 Cont ID  
Sent By jleahy Date 2022-10-18 Time 07:32 Rev Time 0.00
Received By jleahy Date 2022-10-18 Time 16:06 Sent To  
Notes
2022-10-20 15:32:28FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) PAGE 103, 302 WEATHER PROOF OUTLETS IN WET LOCATION
 REQUIRE A WEATHER PROOF INUSE COVE COVER
  
 46.9 0(1) RECEPTACLES OF 15 AND 20 AMPERES IN A WET
 LOCATION.
  
 RECEPTACLES OF 15 AND 20 AMPERES, 125 AND 250 VOLTS
 INSTALLED IN A WET LOCATION SHALL HAVE AN ENCLOSURE
 THAT IS WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG
 CAP IS INSERTED. AN OUTLET BOX HOOD INSTALLED FOR
 THIS PURPOSE SHALL BE LISTED AND SHALL BE IDENTIFIED AS
 ???EXTRA-DUTY.??? OTHER LISTED PRODUCTS, ENCLOSURES, OR
 ASSEMBLIES PROVIDING WEATHERPROOF PROTECTION THAT DO
 NOT UTILIZE AN OUTLET BOX HOOD NEED NOT BE MARKED
 ???EXTRA DUTY.???
  
 PLEASE SUBMIT A LISTING FOR THE INUSE FLOOR BOX COVER.
  
 2) RISER IS MISSING PLEASE SUBMIT A RISER DIAGRAM 215.5
  
 3) PANEL SCHEDULES ARE MISSING.
  
 4) GFCI REQUIREMENTS HAVE BEEN EXPANDED IN THE 2017 NEC
 PLEASE READ 210.8(B) FOR TYPE AND LOCATION OF GFCIS.
  
 210.8(B) OTHER THAN DWELLING UNITS.
  
 ALL SINGLE-PHASE RECEPTACLES RATED 150 VOLTS TO GROUND
 OR LESS, 50 AMPERES OR LESS AND THREE-PHASE RECEPTACLES
 RATED 150 VOLTS TO GROUND OR LESS, 100 AMPERES OR LESS
 INSTALLED IN THE FOLLOWING LOCATIONS SHALL HAVE
 GROUND-FAULT
 CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-08-01 Cont ID  
Sent By jleahy Date 2022-08-01 Time 11:05 Rev Time 0.00
Received By jleahy Date 2022-07-30 Time 15:34 Sent To  
Notes
2022-07-30 18:52:32 
  
 1) 225 KVA TRANSFORMER TO BE INSTALLED PER 450.21(B)
  
 OVER 112 KVA. INDIVIDUAL DRY-TYPE TRANSFORMERS OF MORE
 THAN 112KVA RATING SHALL BE INSTALLED IN A TRANSFORMER
 ROOM
 OF FIRE-RESISTANT CONSTRUCTION. UNLESS SPECIFIED
 OTHERWISE IN THIS ARTICLE, THE TERM FIRE RESISTANT
 MEANS A CONSTRUCTION HAVING A
 MINIMUM FIRE RATING OF 1 HOUR.
  
 2) PLEASE LAYOUT ELECTRICAL ROOM IN NEW BAR AREA FOR
 WORKING CLEARANCES AND OVERHEAD CLEARANCES FOR
 MECHANICAL EQUIPMENT. 110.26
  
 3) ALL OUTDOOR OUTLETS 125, AND 240 VOLT TO BE GFCI
 PROTECTED PER 210.8(B) 50 AMPERES SINGLE PHASE AND 100
 AMPERES FOR THREE PHASE.
  
 210.8(B) OTHER THAN DWELLING UNITS. ALL SINGLE-PHASE
 RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 50
 AMPERES OR LESS AND THREEPHASE
 RECEPTACLES RATED 150 VOLTS TO GROUND OR LESS, 100
 AMPERES OR LESS INSTALLED IN THE FOLLOWING LOCATIONS
 SHALL HAVE GROUND-FAULT
 CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL.
  
 RECEPTACLES OF 15 AND 20 AMPERES IN A WET LOCATION.
 RECEPTACLES OF 15 AND 20 AMPERES, 125 AND 250 VOLTS
 INSTALLED
 IN A WET LOCATION SHALL HAVE AN ENCLOSURE THAT IS
 WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS
 INSERTED. AN OUTLET
 BOX HOOD INSTALLED FOR THIS PURPOSE SHALL BE LISTED AND
 SHALL BE IDENTIFIED AS ?EXTRA-DUTY.? OTHER LISTED
 PRODUCTS, ENCLOSURES, OR
 ASSEMBLIES PROVIDING WEATHERPROOF PROTECTION THAT DO
 NOT UTILIZE AN OUTLET BOX HOOD NEED NOT BE MARKED
 ?EXTRA DUTY.?
  
 4) RECEPACLES THAT LOOK LIKE THEY ARE FLOOR BOXES IN
 THE POOL AREA DECK AND OTHER AREAS ON ROOF DECK PLEASE
 SHOW DETAIL. 406.9
  
 5) COVERS FOR RECEPATCLES INSTALLED IN DAMP/WET
 LOCATION SHALL MEET THE REQUIREMENTS OF 406.9(A)
  
 406.9(A) DAMP LOCATIONS. A RECEPTACLE INSTALLED
 OUTDOORS IN A LOCATION PROTECTED FROM THE WEATHER OR IN
 OTHER DAMP LOCATIONS
 SHALL HAVE AN ENCLOSURE FOR THE RECEPTACLE THAT IS
 WEATHERPROOF WHEN THE RECEPTACLE IS COVERED (ATTACHMENT
 PLUG CAP NOT
 INSERTED AND RECEPTACLE COVERS CLOSED).
  
 6) SOME OF THE SPEAKERS ARE ON 120 VOLT CIRCUITS AND
 SOME ARE NOT, PLEASE DISGUIGUISH BETWEEN THE TYPES
 110.3
  
 7) FANS INSTALLED AROUND POOL NEED TO SHOW DISTANCE AND
 HEIGHT FROM POOL. 680.22(B)(1)
  
 8) MDP1LOAD CALCULATION SHOWS EXISTING? I DO NOT SEE
 PANELS A,B AND OTHER LOADS NOT LISTED ON PANEL SCHEDULE
 FOR MDP1. 220
 PLEASE SHOW HOW THE LOAD CALCULATION WAS ARRIVED AT FOR
 MDP1, AND MDP2 YOU CAN NOT USE A DEMAND ON A PANEL THAT
 WAS
 ALREADY DEMANDED WHEN SIZING THE PANEL.
  
 9) IS THE VIP LEVEL AND THE ROOF LEVEL THE SAME?
  
 10) NEED A LAYOUT OF THE POOL EQUIPMENT ON PLAN.
  
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 2 Status P Date 2022-11-15 Cont ID  
Sent By jleahy Date 2022-11-15 Time 08:14 Rev Time 0.00
Received By jleahy Date 2022-10-18 Time 16:08 Sent To  
Notes
2022-11-15 08:15:41TV , VOICE, DATA , AND SPEAKERS

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status F Date 2022-08-01 Cont ID  
Sent By jleahy Date 2022-08-01 Time 11:19 Rev Time 0.00
Received By jleahy Date 2022-08-01 Time 11:06 Sent To  
Notes
2022-08-01 12:45:50TV, VOICE AND DATA, SOME SPEAKERS. NEED TO SPELL OUT
 WHAT LOW VOLTAGE SYSTEMS ARE.

Review Stop ENG ENGINEERING CSD
Rev No 7 Status P Date 2023-06-01 Cont ID  
Sent By lquinone Date 2023-06-01 Time 10:48 Rev Time 0.00
Received By lquinone Date 2023-06-01 Time 10:47 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 6 Status F Date 2023-05-25 Cont ID  
Sent By lquinone Date 2023-05-25 Time 07:17 Rev Time 0.00
Received By lquinone Date 2023-05-25 Time 07:16 Sent To  
Notes
2023-05-25 07:17:49AWAITING SITE PLAN APPROVAL AND FORMAL ENGINEERING
 SUBMITTAL.
  
 THANKS,
 LINDA M. QUINONES-CINTRON, PROJECT COORDINATOR,
 ENGINEERING SERVICES DEPARTMENT (561) 494-1085
 [email protected]
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop ENG ENGINEERING CSD
Rev No 5 Status F Date 2023-05-04 Cont ID  
Sent By lquinone Date 2023-05-04 Time 11:16 Rev Time 0.00
Received By lquinone Date 2023-05-04 Time 11:16 Sent To  
Notes
2023-05-04 11:16:47AWAITING SITE PLAN APPROVAL AND FORMAL ENGINEERING
 SUBMITAL.
  
 THANKS,
 LINDA M. QUINONES-CINTRON, PROJECT COORDINATOR,
 ENGINEERING SERVICES DEPARTMENT (561) 494-1085
 [email protected]
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop ENG ENGINEERING CSD
Rev No 4 Status F Date 2023-04-06 Cont ID  
Sent By lquinone Date 2023-04-06 Time 14:12 Rev Time 0.00
Received By lquinone Date 2023-04-06 Time 14:12 Sent To  
Notes
2023-04-06 14:13:39AWAITING SITE PLAN APPROVAL AND FORMAL ENGINEERING
 SUBMITAL.
  
 THANKS,
 LINDA M. QUINONES-CINTRON, PROJECT COORDINATOR,
 ENGINEERING SERVICES DEPARTMENT (561) 494-1085
 [email protected]
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop ENG ENGINEERING CSD
Rev No 3 Status F Date 2023-03-13 Cont ID  
Sent By rrossano Date 2023-03-13 Time   Rev Time 0.00
Received By rrossano Date 2023-03-13 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2023-02-21 Cont ID  
Sent By rrossano Date 2023-02-21 Time   Rev Time 0.00
Received By rrossano Date 2023-02-21 Time   Sent To  
Notes
2023-02-21 10:04:44AWAITING SITE PLAN APPROVAL AND FORMAL ENG SUBMITTAL.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2023-02-13 Cont ID  
Sent By rrossano Date 2023-02-13 Time   Rev Time 0.00
Received By rrossano Date 2023-02-13 Time   Sent To I
Notes
2023-02-13 10:12:11AWAITING SITE PLAN APPROVAL AND FORMAL ENG SUBMITTAL.

Review Stop FIRE FIRE DEPARTMENT
Rev No 9 Status P Date 2023-07-14 Cont ID  
Sent By pleduc Date 2023-07-14 Time   Rev Time 0.00
Received By pleduc Date 2023-07-14 Time 09:04 Sent To  
Notes
2023-07-14 09:04:34FIRE PROVISO:
  
 THE COOKING HEARTH AND/OR THE OPEN PIT WOOD BURNING
 GRILL IS NOT APPROVED UNDER THIS PERMIT NOR
 ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR
 TO APPROVAL.
  
 IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 8 Status P Date 2023-07-12 Cont ID  
Sent By pleduc Date 2023-07-12 Time   Rev Time 0.00
Received By pleduc Date 2023-07-12 Time 14:12 Sent To  
Notes
2023-07-12 14:13:19FIRE PROVISO:
  
 THE COOKING HEARTH AND/OR THE OPEN PIT WOOD BURNING
 GRILL IS NOT APPROVED UNDER THIS PERMIT NOR
 ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR
 TO APPROVAL.
  
 IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 7 Status P Date 2023-06-28 Cont ID  
Sent By pleduc Date 2023-06-28 Time   Rev Time 0.00
Received By pleduc Date 2023-06-28 Time 09:46 Sent To  
Notes
2023-06-28 09:46:18FIRE PROVISO:
  
 THE COOKING HEARTH AND/OR THE OPEN PIT WOOD BURNING
 GRILL IS NOT APPROVED UNDER THIS PERMIT NOR
 ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR
 TO APPROVAL.
  
 IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 6 Status P Date 2023-06-15 Cont ID  
Sent By pleduc Date 2023-06-15 Time   Rev Time 0.00
Received By pleduc Date 2023-06-15 Time 10:16 Sent To  
Notes
2023-06-15 10:16:55FIRE PROVISO:
  
 THE COOKING HEARTH AND/OR THE OPEN PIT WOOD BURNING
 GRILL IS NOT APPROVED UNDER THIS PERMIT NOR
 ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR
 TO APPROVAL.
  
 IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2023-02-16 Cont ID  
Sent By pleduc Date 2023-02-16 Time   Rev Time 0.00
Received By pleduc Date 2023-02-16 Time 09:45 Sent To  
Notes
2023-02-16 09:46:03FIRE PROVISO:
  
 THE COOKING HEARTH AND/OR THE OPEN PIT WOOD BURNING
 GRILL IS NOT APPROVED UNDER THIS PERMIT NOR
 ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR
 TO APPROVAL.
  
 IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2023-01-24 Cont ID  
Sent By pleduc Date 2023-01-24 Time   Rev Time 0.00
Received By pleduc Date 2023-01-20 Time 10:09 Sent To  
Notes
2023-01-24 13:13:10FIRE PROVISO:
  
 THE COOKING HEARTH AND/OR THE OPEN PIT WOOD BURNING
 GRILL IS NOT APPROVED UNDER THIS PERMIT NOR
 ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR
 TO APPROVAL.
  
 IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-12-02 Cont ID  
Sent By pleduc Date 2022-12-02 Time   Rev Time 0.00
Received By pleduc Date 2022-11-28 Time 10:24 Sent To  
Notes
2022-12-02 11:48:34FIRE PROVISO:
 THE COOKING HEARTH IS NOT APPROVED UNDER THIS PERMIT
 NOR
 ANY OTHER PERMIT AND SHALL NOT BE PUT IN SERVICE PRIOR
 TO APPROVAL.
  
 IT SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-09-27 Cont ID  
Sent By pleduc Date 2022-09-27 Time   Rev Time 0.00
Received By pleduc Date 2022-09-27 Time 10:33 Sent To  
Notes
2022-09-27 10:53:15FIRE PROVISO:
  
 PLEASE ENSURE THE FOLLOWING COMMENTS ARE ADDRESSED
 DURING CONSTUCTION AND AT THE TIME OF FIRE FINAL
 INSPECTIONS.
  
  
 1) SHEET A 203 - THERE IS AN INDICATION OF POOL
 EQUIPMENT ROOM/AREA/PLATFORM
  
 THE DOOR LEADING TO THIS AREA SHALL BE PLACARD PER NFPA
 1 & 704 FOR THE CHEMICAL STORAGE.
  
  
 1A) SHEET A 203 - PLEASE PROVIDE THE TYPE, AMOUNT,
 SEPARATION AND SAFE POOL CHEMICAL STORAGE IN THE POOL
 EQUIPMENT AREA PER NFPA 1
 AND ALL APPLICABLES CODES.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-07-06 Cont ID  
Sent By   Date 2022-07-06 Time   Rev Time 0.00
Received By bdolan Date 2022-07-06 Time 10:52 Sent To  
Notes
2022-06-29 13:44:21THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) SHEET E 000 - THERE ARE NO INDICATIONS OF FIRE ALARM
 DEVICES, EQUIPMENT, NOR FIRE AMARM WORK
  
 THE FIRE ALARM SYSTEM SHALL BE MAINTAINED THROUGHOUT
 DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE ALARM, INCLUDING DEMO, SHALL BE
 DONE UNDER SEPARATE PERMITS & SHOP DRAWINGS.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGMENT.
  
  
  
 2) ELECTRICAL SHEETS - THERE ARE NO INDICATIONS OF ANY
 ELECTRICAL SHEETS SHOWING THE LOCATION OF REQUIRED EXIT
 LIGHTS & EMERGENCY LIGHTING.
  
 EXIT MARKINGS, EXIT TAVEL PATH SIGNS AND EMEREGENCY
 LIGHTING ARE REQUIRED BY NFPA 101 CH 12 NEW ASSEMBLY
 OCCUPANCY & CH 7 MEANS OF EGRESS.
  
 PLEASE PROVIDE SPECIF DETAILS IN COMPLIANCE WITH THE
 CODE.
  
  
 3) SHEET A 203 - THERE IS AN INDICATION OF POOL
 EQUIPMENT ROOM/AREA/PLATFORM
  
 THE DOOR LEADING TO THIS AREA SHALL BE PLACARD PER NFPA
 1 & 704 FOR THE CHEMICAL STORAGE.
  
  
 3A) SHEET A 203 - PLEASE PROVIDE THE TYPE AND AMOUNT OF
 PROPOSED CHEMICAL STORAGE IN THE POOL EQUIPMENT AREA.
  
 PER NFPA 1
  
  
  
  
  
 WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET REVISION
 CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2023-03-02 Cont ID  
Sent By rwbrown Date 2023-03-02 Time 13:38 Rev Time 0.00
Received By rwbrown Date 2023-03-02 Time   Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2022-11-28 Cont ID  
Sent By rwbrown Date 2022-11-28 Time 11:58 Rev Time 0.00
Received By rwbrown Date 2022-11-28 Time   Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2022-07-20 Cont ID  
Sent By rwbrown Date 2022-07-20 Time 13:41 Rev Time 0.00
Received By rwbrown Date 2022-07-20 Time 09:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2023-07-14 Cont ID  
Sent By rmcphers Date 2023-07-14 Time 09:18 Rev Time 0.00
Received By rmcphers Date 2023-07-13 Time 09:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2023-07-12 Cont ID  
Sent By aoliver Date 2023-07-12 Time 14:35 Rev Time 0.00
Received By aoliver Date 2023-07-11 Time 08:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2023-07-10 Cont ID  
Sent By hmoser Date 2023-07-10 Time 07:28 Rev Time 0.00
Received By hmoser Date 2023-06-22 Time 16:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2023-06-21 Cont ID  
Sent By lmarchan Date 2023-06-21 Time 14:39 Rev Time 0.00
Received By lmarchan Date 2023-06-14 Time 10:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2023-06-13 Cont ID  
Sent By aoliver Date 2023-06-13 Time 07:12 Rev Time 0.00
Received By aoliver Date 2023-05-15 Time 08:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2023-05-12 Cont ID  
Sent By medwards Date 2023-05-12 Time 15:19 Rev Time 0.00
Received By lmarchan Date 2023-04-28 Time 08:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2023-04-27 Cont ID  
Sent By aoliver Date 2023-04-27 Time 07:52 Rev Time 0.00
Received By aoliver Date 2023-03-30 Time 11:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2023-03-27 Cont ID  
Sent By lmarchan Date 2023-03-27 Time 08:01 Rev Time 0.00
Received By lmarchan Date 2023-03-01 Time 16:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-02-28 Cont ID  
Sent By lmarchan Date 2023-02-28 Time 08:03 Rev Time 0.00
Received By lmarchan Date 2023-02-15 Time 07:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-02-14 Cont ID  
Sent By lmarchan Date 2023-02-14 Time 07:47 Rev Time 0.00
Received By lmarchan Date 2023-01-19 Time 16:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-12-09 Cont ID  
Sent By jleahy Date 2022-12-09 Time 09:09 Rev Time 0.00
Received By jleahy Date 2022-11-23 Time 08:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-11-15 Cont ID  
Sent By jleahy Date 2022-11-15 Time 08:15 Rev Time 0.00
Received By jleahy Date 2022-09-23 Time 08:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-02 Cont ID  
Sent By rmcphers Date 2022-09-02 Time 08:32 Rev Time 0.00
Received By rmcphers Date 2022-06-28 Time 09:46 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By aoliver Date 2023-07-14 Time 09:30 Sent To  
Notes
2023-07-14 09:29:43IMPACT FEE QUEST UPLOADED. PBCGOV EMAILED AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-09-02 Cont ID  
Sent By rmcphers Date 2022-09-02 Time 08:26 Rev Time 0.00
Received By rmcphers Date 2022-09-02 Time 08:26 Sent To  
Notes
2022-09-02 08:26:50PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 8 Status P Date 2023-07-10 Cont ID  
Sent By hmoser Date 2023-07-10 Time 07:28 Rev Time 0.00
Received By hmoser Date 2023-07-10 Time 06:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2023-05-26 Cont ID  
Sent By hmoser Date 2023-05-26 Time 13:27 Rev Time 0.00
Received By hmoser Date 2023-05-26 Time 13:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 6 Status F Date 2023-05-10 Cont ID  
Sent By medwards Date 2023-05-10 Time 14:11 Rev Time 0.00
Received By medwards Date 2023-05-10 Time 14:11 Sent To  
Notes
2023-05-10 16:36:036TH REVIEW FMC
 PERMIT:
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE NEW ENGINEER KELVIN T CHANG MUST SUBMIT ALL NEW
 MECHANICAL DESIGN WITH THEIR DIGITAL SIGNATURE. THERE
 ARE SOME DRAWINGS WITH THE ORIGINAL ENGINEER, JAMES C.
 DIPASQUALE. DIGITAL SIGNATURE IN TIS DESIGN. SHEETS
 M-002, M-003, M-501 STILL BEAR THE DIGITAL SIGNATURE OF
 JAMES C. DIPASQUALE.
 61G15-27.001
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2023-04-06 Cont ID  
Sent By medwards Date 2023-04-06 Time 15:26 Rev Time 0.00
Received By medwards Date 2023-04-06 Time 15:26 Sent To  
Notes
2023-04-06 15:35:27IT APPEARS THAT THE MECHANICAL DOCUMENTS NOW HAVE A
 REVISION 5. THERE ARE NO CLOUDS ON THE DRAWINGS FOR
 THIS 5TH REVISION AND NO NARRATIVE SUBMITTED FOR THIS
 5TH REVISION. PLEASE CLOUD THE CHANGES MADE FOR THIS
 REVISION AND PROVIDE A NARRATIVE OF CHANGES FOR THIS
 5TH REVISION.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2023-01-24 Cont ID  
Sent By medwards Date 2023-01-24 Time 17:32 Rev Time 0.00
Received By medwards Date 2023-01-24 Time 17:32 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2022-11-30 Cont ID  
Sent By medwards Date 2022-11-30 Time 09:21 Rev Time 0.00
Received By medwards Date 2022-11-30 Time 09:21 Sent To  
Notes
2022-11-30 09:22:053RD REVIEW FMC
 PERMIT: 22061092
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 THE COMMENTS BELOW FOR THE KITCHEN HOOD EXHAUST IS ONLY
 HERE BECAUSE THEY ARE MINGLED WITH THE DESIGN OF THIS
 BUILDING, IF I WAITED UNTIL THE KITCHEN HOOD PERMITS
 AND REVIEW IT COULD MEAN A LOT OF CHANGES. NOTE THAT
 THIS IS NOT A REVIEW OF THE KITCHEN HOODS AND GREASE
 DUCT. JUST REFERENCE FOR THE CONSTRUCTION OF THIS
 REMODEL.
  
 1) I DO NOT SEE THE NOTE ON THE MECHANICAL DRAWINGS
 THAT STATES THE KITCHEN HOOD AND GREASE DUCT WILL
 REQUIRE A SEPARATE PERMIT APPLICATION AND SUBMITTAL FOR
 PLAN REVIEW AS THEY WILL NOT BE REVIEWED UNDER THIS
 PERMIT. PLEASE ADD THE NOTE TO THE MECHANICAL DRAWINGS.
  
 2) I DO NOT SEE THE NOTE ON THE MECHANICAL DRAWINGS
 THAT STATES THE REFRIGERATION FOR THE WALK-IN COOLERS
 AND FREEZER WILL REQUIRE A SEPARATE PERMIT APPLICATION
 AND SUBMITTAL FOR PLAN REVIEW AS THEY WILL NOT BE
 REVIEWED UNDER THIS PERMIT. PLEASE ADD THE NOTE TO THE
 MECHANICAL DRAWINGS.
  
 3) SHEET M-102: THE HOOD EXHAUST TERMINATION LOCATION
 MUST BE A MINIMUM OF 10 FEET FROM THE PROPERTY LINE.
 FMC 501.3.1 ITEM NUMBER 2
  
 4) THE WOMEN???S BATH ROOMS ON THE 1ST FLOOR SHOWS AN
 EXHAUST GRILLE IN THE HANDICAP BOOTH WITH 0 CFM???S OF
 EXHAUST. PLEASE CORRECT THIS. FBC 107.3.5
  
 5) THE DIGITAL SIGNATURE ON THE MECHANICAL DRAWINGS ARE
 COPIES OF THE ORIGINAL AS THEY DO NOT SHOW AS DIGITAL
 SIGNATURES IN OUR SOFTWARE. PLEASE PROVIDE THE ORIGINAL
 DIGITALLY SIGNED DRAWINGS. FS 471/481
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-09-27 Cont ID  
Sent By medwards Date 2022-09-26 Time 17:15 Rev Time 0.00
Received By medwards Date 2022-09-26 Time 17:15 Sent To  
Notes
2022-09-26 17:17:422ND REVIEW FMC
 PERMIT: 22061092
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M-102: IT APPEARS THAT KEF-2 IS EXHAUSTING
 TOWARDS THE STAIRWAY DOOR. PLEASE SHOW THIS KEF-2 IS
 NOT EXHAUSTING WITHIN 10 FEET OF ANY OPENING INTO THE
 BUILDING. ALSO SHOW THE PROPERTY LINE AND THE EXHAUST
 DISTANCE TO THE PROPERTY LINE FOR THE KEF???S. FMC
 501.3.1-2
  
 2) PLEASE PROVIDE A LIST OF THE AREAS EF-1 SERVES, IT
 APPEARS THAT IT IS EXHAUSTING A DISHWASHER ALONG WITH
 THE BATHROOM EXHAUSTS. FBC 107.3.5
  
 3) PLEASE SHOW THAT EF-1 IS MEETING THE REQUIREMENT OF
 EXHAUST BEING 3 FEET FROM AN OPENING INTO THE BUILDING.
 FMC 501.3.1-3
  
 4) SHEET M-001, WATER SOURCE HEAT PUMP SCHEDULE
 INDICATES A TOTAL TONNAGE OF ALL HP???S TO BE 49 TONS.
 THE COOLING TOWER SCHEDULE INDICATES CT-1 IS 50 TONS.
 THE MECHANICAL EQUIPMENT SIZING CALCULATIONS SHOW A
 TOTAL SYSTEM LOADS OF 208105 BTU???S WHICH IF DIVIDED
 BY 12,000 WOULD BE 17.34 TONS. PLEASE PROVIDE A
 MECHANICAL EQUIPMENT SIZING CALCULATION FOR THE ENTIRE
 PROJECT. FBC 107.3.5
  
 5) 2ND ATTEMPT; PLEASE PROVIDE THE OUTDOOR AIR
 CALCULATIONS FOR EACH USE OF SPACE FOR THIS BUILDING.
 FMC 403.3.1.1 AND TABLE 403.3.1.1
  
 6) SHEET M-104: PROVIDE A DETAIL DRAWING OF THE KEF???S
 PENETRATION OF THE ROOF AND THE ANCHORAGE OF THE
 KEF???S. IS THE RETRACTABLE ROOF GOING TO OPEN AROUND
 THESE KEF???S? FBC 107.3.5
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-07-18 Cont ID  
Sent By medwards Date 2022-07-18 Time 14:59 Rev Time 0.00
Received By medwards Date 2022-07-18 Time 14:59 Sent To  
Notes
2022-07-18 14:59:531ST REVIEW FMC
 PERMIT: 22061493
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE A MECHANICAL DEMO PLAN FOR THIS PROJECT. FBC
 107.2.1
  
 2) PROVIDE THE ENERGY CALCULATIONS. FEC 101.5.1.1.2
  
 3) PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FEC 403.2.1
  
 4) PROVIDE THE OUT DOOR AIR CALCULATIONS. FMC 403.3.1.1
  
 5) ADD NOTE ON THE MECHANICAL DRAWINGS INDICATING THAT
 THE HOODS AND GREASE DUCT SYSTEMS AND THE REFRIGERATION
 SYSTEMS IE WALK-IN COOLERS AND WALK-IN FREEZERS WILL
 REQUIRE A SEPARATE PERMIT AND PLAN REVIEW AND WILL NOT
 BE REVIEWED UNDER THIS PERMIT. FBC 107.2.1
  
 6) SHEET M-103: REVISE THE DRAWING TO SHOW THE BATHROOM
 EXHAUST FOR THE BATHROOMS IN THE DINING AREA. FMC TABLE
 403.3.1.1
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 6 Status P Date 2023-03-02 Cont ID  
Sent By rwbrown Date 2023-03-02 Time 13:38 Rev Time 0.00
Received By rwbrown Date 2023-03-02 Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status P Date 2023-02-16 Cont ID  
Sent By rwbrown Date 2023-02-16 Time 08:06 Rev Time 0.00
Received By rwbrown Date 2023-02-16 Time 08:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2023-01-20 Cont ID  
Sent By rwbrown Date 2023-01-20 Time 08:42 Rev Time 0.00
Received By rwbrown Date 2023-01-20 Time   Sent To  
Notes
2023-01-20 08:42:264TH PLUMBING REVIEW
  
  
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. DONE
  
  
 2. ---NOT ADDRESSED----2017 WPB AMEND - 107.3 - THE
 GREASE INTERCEPTOR REQUIRES A SEPARATE PERMIT AND NEEDS
 TO BE APPLIED FOR BEFORE THE RELEASE OF THE MASTER
 PERMIT.
  
 3. --DONE
  
  
 4. DONE
  
 5. DONE
  
 6. -DONE
  
  
 7. DONE
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2022-11-28 Cont ID  
Sent By rwbrown Date 2022-11-28 Time 11:58 Rev Time 0.00
Received By rwbrown Date 2022-11-28 Time   Sent To  
Notes
2022-11-28 12:04:193RD PLUMBING REVIEW
  
  
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. DONE
  
  
 2. ---NOT ADDRESSED----2017 WPB AMEND - 107.3 - THE
 GREASE INTERCEPTOR REQUIRES A SEPARATE PERMIT AND NEEDS
 TO BE APPLIED FOR BEFORE THE RELEASE OF THE MASTER
 PERMIT.
  
 3. --DONE
  
  
 4. DONE
  
 5. DONE
  
 6. -DONE
  
  
 7. DONE
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-09-26 Cont ID  
Sent By rwbrown Date 2022-09-26 Time 12:39 Rev Time 0.00
Received By rwbrown Date 2022-09-26 Time 12:09 Sent To  
Notes
2022-09-26 12:40:281ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. ---NOT ADDRESSED----2020 FPC 1003.3.1 - ONLY DEVICES
 DESIGNED TO RECEIVE FATS, OILS AND GREASE SHALL BE
 DIRECTED TO THE GREASE WASTE. PLEASE SHOW THAT THE ICE
 BINS AND HANDS SINK GO TO THE SANITARY AND NOT THE
 GREASE WASTE.
  
 2. ---NOT ADDRESSED----2017 WPB AMEND - 107.3 - THE
 GREASE INTERCEPTOR REQUIRES A SEPARATE PERMIT AND NEEDS
 TO BE APPLIED FOR BEFORE THE RELEASE OF THE MASTER
 PERMIT.
  
 3. ---NOT ADDRESSED----2020 FPC 905.4 - ON EACH END OF
 THE BATHROOMS, THE VENT NEAR THE WATER CLOSET IS
 HORIZONTAL AND CANNOT BE UNTIL IT IS 6" ABOVE THE FLOOD
 RIM OF THE FIXTURES SERVED.
  
 4. ---NOT ADDRESSED----2020 FPC 905.4 - THE VENTS FOR
 THE GREASE INTERCEPTORS ARE HORIZONTAL WHILE DRY AND
 CANNOT BE. THE VENT CANNOT BE A HORIZONTAL DRY VENT
 UNTIL IT IS 6" ABOVE THE FLOOD RIM OF THE FIXTURES
 SERVED.
 5. DONE
  
 6. ---NOT ADDRESSED----WPB ORD. SEC. 90 - 126 - THE
 DISCHARGE FROM AIR HANDLERS/AIR CONDITIONING CONDENSATE
 CANNOT DISCHARGE INTO THE SANITARY. IT MUST GO TO THE
 STORM OR OTHER APPROVED PLACE OF DISPOSAL.
  
 7. ---NOT ADDRESSED----2020 FPC 419.5/607.1.2 - PLEASE
 INCLUDE A DETAIL SHOWING COMPLIANCE WITH THE
 REQUIREMENTS FOR TEMPERED WATER FOR PUBLIC HANDWASHING
 STATIONS THAT INCLUDES THE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070.
  
  
  
  
 ---NOT ADDRESSED----WHEN RESUBMITTING, IT IS HELPFUL TO
 PROVIDE A RESPONSE LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-07-20 Cont ID  
Sent By rwbrown Date 2022-07-20 Time 12:11 Rev Time 0.00
Received By rwbrown Date 2022-07-20 Time 09:32 Sent To  
Notes
2022-07-20 12:11:411ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FPC 1003.3.1 - ONLY DEVICES DESIGNED TO RECEIVE
 FATS, OILS AND GREASE SHALL BE DIRECTED TO THE GREASE
 WASTE. PLEASE SHOW THAT THE ICE BINS AND HANDS SINK GO
 TO THE SANITARY AND NOT THE GREASE WASTE.
  
 2. 2017 WPB AMEND ? 107.3 - THE GREASE INTERCEPTOR
 REQUIRES A SEPARATE PERMIT AND NEEDS TO BE APPLIED FOR
 BEFORE THE RELEASE OF THE MASTER PERMIT.
  
 3. 2020 FPC 905.4 - ON EACH END OF THE BATHROOMS, THE
 VENT NEAR THE WATER CLOSET IS HORIZONTAL AND CANNOT BE
 UNTIL IT IS 6? ABOVE THE FLOOD RIM OF THE FIXTURES
 SERVED.
  
 4. 2020 FPC 905.4 - THE VENTS FOR THE GREASE
 INTERCEPTORS ARE HORIZONTAL WHILE DRY AND CANNOT BE.
 THE VENT CANNOT BE A HORIZONTAL DRY VENT UNTIL IT IS 6?
 ABOVE THE FLOOD RIM OF THE FIXTURES SERVED.
 5. WPB ORD. SEC 90 - 205 EXCEPTIONS TO DISCHARGE TO
 STORM WATER
 SWIMMING POOL WATER SHALL NOT BE DISCHARGED TO SANITARY
 SEWER WITHOUT PRIOR APPROVAL FROM THE PUBLIC UTILITIES
 DEPARTMENT.
 SWIMMING POOL WATER MAY BE DISCHARGED TO THE CITY
 STORMWATER SEWER ONLY IF THE WATER IS DECHLORINATED
 ACCORDING TO SECTION 90-205(1) OF THE CITY OF WEST PALM
 BEACH CODE OF ORDINANCES. SUBMIT THE MANUFACTURER'S
 SPECIFICATION FOR THE DICHLORINATION SYSTEM FOR REVIEW
 AND STAMPING BEFORE THE INSPECTION. AT THE TIME OF POOL
 WATER DISCHARGE, THE FOLLOWING WILL BE REQUIRED:
 - THE RECEIVING INLET MUST BE PROTECTED (FILTER CLOTH
 TO KEEP EXCESS SEDIMENTS FROM ROADWAY WASHING INTO THE
 INLET).
 - NO DISCHARGE HOSE CAN BE DIRECTLY INSERTED INTO THE
 INLET TO DISCHARGE EFFLUENT.
 - WHENEVER POSSIBLE, DISCHARGE EFFLUENT SHALL BE
 ALLOWED TO FILTER THROUGH GRASS AREA ON THE POOL
 OWNER'S PROPERTY BEFORE DISCHARGING ON CITY PROPERTY.
 - DISCHARGE SHALL NOT FLOOD STREETS OR NEIGHBORING
 PROPERTY.
 - FOR TECHNICAL QUESTIONS, CONTACT O&M SUPERINTENDENT
 STEPHON HARRIS AT [email protected] OR 561-822-2168.
 - FOR STORMWATER DISCHARGE COMPLIANCE QUESTIONS, PLEASE
 CONTACT CHRIS JACKSON, ENVIRONMENTAL COMPLIANCE
 SPECIALIST III, PUBLIC UTILITIES DEPARTMENT, (561)
 822-2062 OR [email protected].
  
 6. WPB ORD. SEC. 90 - 126 - THE DISCHARGE FROM AIR
 HANDLERS/AIR CONDITIONING CONDENSATE CANNOT DISCHARGE
 INTO THE SANITARY. IT MUST GO TO THE STORM OR OTHER
 APPROVED PLACE OF DISPOSAL.
  
 7. 2020 FPC 419.5/607.1.2 - PLEASE INCLUDE A DETAIL
 SHOWING COMPLIANCE WITH THE REQUIREMENTS FOR TEMPERED
 WATER FOR PUBLIC HANDWASHING STATIONS THAT INCLUDES THE
 LIMITING DEVICE THAT CONFORMS TO ASSE 1070.
  
  
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 13 Status P Date 2023-07-14 Cont ID  
Sent By rmcphers Date 2023-07-14 Time 09:18 Rev Time 0.00
Received By rmcphers Date 2023-07-14 Time 09:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 12 Status P Date 2023-07-11 Cont ID  
Sent By rmcphers Date 2023-07-11 Time 15:40 Rev Time 0.00
Received By rmcphers Date 2023-07-11 Time 15:40 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 11 Status P Date 2023-06-26 Cont ID  
Sent By rmcphers Date 2023-06-26 Time 15:06 Rev Time 0.00
Received By rmcphers Date 2023-06-26 Time 15:06 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 10 Status P Date 2023-06-20 Cont ID  
Sent By rmcphers Date 2023-06-20 Time 13:11 Rev Time 0.00
Received By rmcphers Date 2023-06-20 Time 13:11 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 9 Status P Date 2023-05-26 Cont ID  
Sent By rmcphers Date 2023-05-26 Time 08:00 Rev Time 0.00
Received By rmcphers Date 2023-05-26 Time 08:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 8 Status P Date 2023-05-10 Cont ID  
Sent By medwards Date 2023-05-10 Time 14:12 Rev Time 0.00
Received By medwards Date 2023-05-10 Time 14:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 7 Status P Date 2023-04-03 Cont ID  
Sent By rmcphers Date 2023-04-03 Time 08:57 Rev Time 0.00
Received By rmcphers Date 2023-04-03 Time 08:57 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2023-03-07 Cont ID  
Sent By rmcphers Date 2023-03-07 Time 10:23 Rev Time 0.00
Received By rmcphers Date 2023-03-07 Time 10:23 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status F Date 2023-02-16 Cont ID  
Sent By rmcphers Date 2023-02-16 Time 15:13 Rev Time 0.00
Received By rmcphers Date 2023-02-16 Time 15:13 Sent To  
Notes
2023-02-16 15:17:07SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS S-002, S-003, P-901, P-902, P-903, P-904,
 P-002, P-101, P-102, P-103, P-104, P-201, P-501, P-502
 DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2023-01-20 Cont ID  
Sent By rmcphers Date 2023-01-20 Time 13:30 Rev Time 0.00
Received By rmcphers Date 2023-01-20 Time 13:30 Sent To  
Notes
2023-01-20 13:31:23SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) SIGNED AND SEALED DRAWINGS SUCH AS STRUCTURAL, FIRE
 PROTECTION AND THE SPECIAL INSPECTOR FORM DO NOT SHOW
 AS DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-12-05 Cont ID  
Sent By rmcphers Date 2022-12-05 Time 14:15 Rev Time 0.00
Received By rmcphers Date 2022-12-05 Time 14:15 Sent To  
Notes
2022-12-05 14:18:17SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) SIGNED AND SEALED DRAWINGS SUCH AS STRUCTURAL, FIRE
 PROTECTION, ELECTRICAL, PLUMBING, MECHANICAL AND THE
 SPECIAL INSPECTOR FORM DO NOT SHOW AS DIGITALLY SIGNED
 IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  
2022-11-30 09:23:24MECHANICAL DIGITAL SIGNATURE REVIEW FAILED. THE
 SIGNATURE IS A COPY OF THE ORIGINAL DIGITAL SIGNATURE.
 ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-10-07 Cont ID  
Sent By rmcphers Date 2022-10-07 Time 09:35 Rev Time 0.00
Received By rmcphers Date 2022-10-07 Time 09:35 Sent To  
Notes
2022-10-07 09:37:06SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) STRUCTURAL AND FIRE PROTECTION DRAWINGS DO NOT SHOW
 AS DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-08-04 Cont ID  
Sent By rwbrown Date 2022-08-04 Time 06:21 Rev Time 0.00
Received By rwbrown Date 2022-08-04 Time 06:21 Sent To  
Notes
2022-08-04 06:22:04MULITPLE PAGES NOT SIGNED/SEALED
  
 ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR
 ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH
 61G1-16 AND 61G15, F.A.C
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
2022-07-18 15:01:09THE MECHANICAL DRAWINGS WILL NEED TO BE DIGITALLYSIGNED
 BY THE EOR. FS 471/481
  
  

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 2 Status P Date 2023-02-16 Cont ID  
Sent By rmcphers Date 2023-02-16 Time 15:17 Rev Time 0.00
Received By rmcphers Date 2023-02-16 Time 15:17 Sent To  
Notes
***NONE***

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 1 Status P Date 2023-01-05 Cont ID  
Sent By rmcphers Date 2023-01-05 Time 09:36 Rev Time 0.00
Received By rmcphers Date 2023-01-05 Time 09:36 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 12 Status P Date 2023-07-13 Cont ID  
Sent By cibaven Date 2023-07-13 Time 16:45 Rev Time 0.00
Received By cibaven Date 2023-07-13 Time 16:45 Sent To  
Notes
2023-07-13 16:45:02PROVISO:
 THE PERMIT NEEDS TO BE REVISED BEFORE INSPECTIONS. ALL
 FLOOR PLANS SHOWING ON ELECTRICAL, PLUMBING,
 FOUNDATION, AND ALL DRAWINGS ARE REQUIRED TO BE UPDATED
 AND MATCH APPROVED FLOOR PLANS OUTLINED IN THE SITE
 PLAN APPROVAL LETTER FOR FSPR CASE NO. 22-24.
  
 IN ADDITION, THE FOLLOWING CONDITIONS WILL ALSO NEED TO
 BE ADDRESSED:
  
 1. PRIOR ISSUANCE OF THE TEMPORARY CERTIFICATE OF
 OCCUPANCY, A REVISED TPS LETTER WILL NEED TO BE
 SUBMITTED TO THE PLANNING DIVISION.
  
 2. PRIOR TO ISSUANCE OF THE TEMPORARY CERTIFICATE OF
 OCCUPANCY, AN AERIAL EASEMENT AGREEMENT WILL BE
 FINALIZED.
  
 3. PRIOR TO ISSUANCE OF THEIR BUILDING PERMIT: THIS
 DEVELOPMENT IS SUBJECT TO THE PUBLIC ART REQUIREMENT,
 HOWEVER THE 1% IS MINIMAL. THEY DO NEED TO COMPLETE AN
 ART ASSESSMENT APPLICATION, SELECT OPTION#2
 CONTRIBUTION INTO THE ART FUND, WHICH MUST BE
 COMPLETED, AND PAID BEFORE, OR AT TIME OF BUILDING
 PERMIT FEES.
  
 4. THE GARBAGE CONTAINERS SHALL BE FRONT-LOAD TYPE TO
 BE COMPATIBLE WITH THE CITY'S SANITATION COLLECTION
 VEHICLES.
  
 5. ALL POOL DISCHARGE MIST BE DECHLORINATED PRIOR TO
 ENTERING THE CITY'S STORMWATER DRAINAGE SYSTEM. NO POOL
 DISCHARGE MAY ENTER THE CITY'S SANITARY SYSTEM.
  
 6. NEW AND EXISTING ROOF DRAIN LEADERS ARE TO BE
 DIRECTLY CONNECTED TO THE DRAINAGE SYSTEM IN THE ALLEY.
 NO OPEN CONNECTIONS TO THE ALLEY SURFACE.
  
 7. ANY WORK WITHIN THE PUBLIC RIGHT OF WAY (ALLEY,
 CLEMATIS ST.) WILL REQUIRE AN ENGINEERING PERMIT.
  
 8. A RIGHT-OF-WAY (ROW) PERMIT IS REQUIRED.
  
 9. THE APPLICANT WILL COORDINATE WITH THE PARKING
 DEPARTMENT AND WILL COPY THE ENGINEERING DEPARTMENT IN
 THE CORRESPONDENCE, WITH THE RESPECT TO THE IMPACTED
 PARKING STALLS WITHIN THE 300 BLOCK.
  
 10. THE DEVELOPER SHALL BE RESPONSIBLE FOR ANY
 INFRASTRUCTURE IMPROVEMENTS REQUIRED TO SERVE THE
 PROJECT.
  
 11. ANY REQUIRED EASEMENTS (I.E. DRAINAGE, UTILITIES,
 PUBLIC ACCESS, OUTFALL, ETC.) SHALL BE PROVIDED VIA
 PLAT OR SEPARATE LEGAL INSTRUMENT.
  
 12. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
 13. UPON APPLICATION FOR A BUILDING PERMIT, THE
 DEVELOPER SHALL SUBMIT TO THE CITY A CONSTRUCTION
 PARKING MANAGEMENT PLAN PER THE PROVISIONS OF CHAPTER
 86, ARTICLE IV, DIVISION 1, SEC. 86-245 OF THE CITY'S
 CODE OF ORDINANCES.
  
 14. ALL CONDITIONS OF APPROVAL INCLUDED IN THE DAC
 FINAL ORDER FOR FSPR 22-24 APPROVED BY THE COMMITTEE ON
 MAY 10, 2023, ARE PART OF THIS SITE PLAN APPROVAL.

Review Stop Z ZONING
Rev No 11 Status P Date 2023-06-28 Cont ID  
Sent By cibaven Date 2023-06-28 Time 17:11 Rev Time 0.00
Received By cibaven Date 2023-06-28 Time 17:10 Sent To  
Notes
2023-06-28 17:11:18PROVISO:
 THE PERMIT NEEDS TO BE REVISED BEFORE INSPECTIONS. ALL
 FLOOR PLANS SHOWING ON ELECTRICAL, PLUMBING,
 FOUNDATION, AND ALL DRAWINGS ARE REQUIRED TO BE UPDATED
 AND MATCH APPROVED FLOOR PLANS OUTLINED IN THE SITE
 PLAN APPROVAL LETTER FOR FSPR CASE NO. 22-24.
  
 IN ADDITION, THE FOLLOWING CONDITIONS WILL ALSO NEED TO
 BE ADDRESSED:
  
 1. PRIOR ISSUANCE OF THE TEMPORARY CERTIFICATE OF
 OCCUPANCY, A REVISED TPS LETTER WILL NEED TO BE
 SUBMITTED TO THE PLANNING DIVISION.
  
 2. PRIOR TO ISSUANCE OF THE TEMPORARY CERTIFICATE OF
 OCCUPANCY, AN AERIAL EASEMENT AGREEMENT WILL BE
 FINALIZED.
  
 3. PRIOR TO ISSUANCE OF THEIR BUILDING PERMIT: THIS
 DEVELOPMENT IS SUBJECT TO THE PUBLIC ART REQUIREMENT,
 HOWEVER THE 1% IS MINIMAL. THEY DO NEED TO COMPLETE AN
 ART ASSESSMENT APPLICATION, SELECT OPTION#2
 CONTRIBUTION INTO THE ART FUND, WHICH MUST BE
 COMPLETED, AND PAID BEFORE, OR AT TIME OF BUILDING
 PERMIT FEES.
  
 4. THE GARBAGE CONTAINERS SHALL BE FRONT-LOAD TYPE TO
 BE COMPATIBLE WITH THE CITY???S SANITATION COLLECTION
 VEHICLES.
  
 5. ALL POOL DISCHARGE MIST BE DECHLORINATED PRIOR TO
 ENTERING THE CITY???S STORMWATER DRAINAGE SYSTEM. NO
 POOL DISCHARGE MAY ENTER THE CITY???S SANITARY SYSTEM.
  
 6. NEW AND EXISTING ROOF DRAIN LEADERS ARE TO BE
 DIRECTLY CONNECTED TO THE DRAINAGE SYSTEM IN THE ALLEY.
 NO OPEN CONNECTIONS TO THE ALLEY SURFACE.
  
 7. ANY WORK WITHIN THE PUBLIC RIGHT OF WAY (ALLEY,
 CLEMATIS ST.) WILL REQUIRE AN ENGINEERING PERMIT.
  
 8. A RIGHT-OF-WAY (ROW) PERMIT IS REQUIRED.
  
 9. THE APPLICANT WILL COORDINATE WITH THE PARKING
 DEPARTMENT AND WILL COPY THE ENGINEERING DEPARTMENT IN
 THE CORRESPONDENCE, WITH THE RESPECT TO THE IMPACTED
 PARKING STALLS WITHIN THE 300 BLOCK.
  
 10. THE DEVELOPER SHALL BE RESPONSIBLE FOR ANY
 INFRASTRUCTURE IMPROVEMENTS REQUIRED TO SERVE THE
 PROJECT.
  
 11. ANY REQUIRED EASEMENTS (I.E. DRAINAGE, UTILITIES,
 PUBLIC ACCESS, OUTFALL, ETC.) SHALL BE PROVIDED VIA
 PLAT OR SEPARATE LEGAL INSTRUMENT.
  
 12. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
 13. UPON APPLICATION FOR A BUILDING PERMIT, THE
 DEVELOPER SHALL SUBMIT TO THE CITY A CONSTRUCTION
 PARKING MANAGEMENT PLAN PER THE PROVISIONS OF CHAPTER
 86 ??? ARTICLE IV ??? DIVISION 1 ??? SEC. 86-245 OF THE
 CITY???S CODE OF ORDINANCES.
  
 14. ALL CONDITIONS OF APPROVAL INCLUDED IN THE DAC
 FINAL ORDER FOR FSPR 22-24 APPROVED BY THE COMMITTEE ON
 MAY 10, 2023, ARE PART OF THIS SITE PLAN APPROVAL.
  
  

Review Stop Z ZONING
Rev No 10 Status F Date 2023-06-20 Cont ID  
Sent By cibaven Date 2023-06-20 Time 17:19 Rev Time 0.00
Received By cibaven Date 2023-06-20 Time 17:18 Sent To  
Notes
2023-06-20 17:19:14PLANS DO NOT MATCH APPROVED SET OF PLANS REFERENCE ON
 THE SITE PLAN APPOVAL LETTER, FOR THE FORMAL SITE PLAN
 REVIEW CASE NO. 22-24 (Z22120027)- 309/613 CLEMATIS
 STREET, ISSUED ON JUNE 12, 2023.

Review Stop Z ZONING
Rev No 9 Status F Date 2023-06-12 Cont ID  
Sent By cibaven Date 2023-06-12 Time 15:54 Rev Time 0.00
Received By cibaven Date 2023-06-12 Time 15:51 Sent To  
Notes
2023-06-12 15:53:13PLANS DO NOT MATCH APPROVED SET OF PLANS REFERENCE ON
 THE SITE PLAN APPOVAL LETTER, FOR THE FORMAL SITE PLAN
 REVIEW CASE NO. 22-24 (Z22120027)- 309/613 CLEMATIS
 STREET, ISSUED ON JUNE 12, 2023.

Review Stop Z ZONING
Rev No 8 Status F Date 2023-05-12 Cont ID  
Sent By ckimmerl Date 2023-05-12 Time 08:54 Rev Time 0.00
Received By ckimmerl Date 2023-05-12 Time 08:54 Sent To  
Notes
2023-05-12 08:54:23PROJECT NEEDS SITE PLAN APPROVAL BEFORE BUILDING
 PERMITS CAN BE REVIEWED AND APPROVED. APPLICATION FSPR
 22-24 (Z22120027) IS IN REVIEW.

Review Stop Z ZONING
Rev No 7 Status F Date 2023-04-26 Cont ID  
Sent By cibaven Date 2023-04-26 Time 08:57 Rev Time 0.00
Received By cibaven Date 2023-04-26 Time 08:57 Sent To  
Notes
2023-04-26 08:57:20PROJECT NEEDS SITE PLAN APPROVAL BEFORE BUILDING
 PERMITS CAN BE REVIEWED AND APPROVED. APPLICATION FSPR
 22-24 (Z22120027) IS IN REVIEW.
  
 CLAUDIA IBAVEN, CITY URBAN DESIGNER
 PLANNING DIVISION
 [email protected]
 516-822-1402

Review Stop Z ZONING
Rev No 6 Status F Date 2023-03-24 Cont ID  
Sent By cibaven Date 2023-03-24 Time 17:10 Rev Time 0.00
Received By cibaven Date 2023-03-24 Time 17:09 Sent To  
Notes
2023-03-24 17:10:26PROJECT NEEDS SITE PLAN APPROVAL BEFORE BUILDING
 PERMITS CAN BE REVIEWED AND APPROVED. APPLICATION FSPR
 22-24 (Z22120027) IS IN REVIEW.
  
 CLAUDIA IBAVEN, CITY URBAN DESIGNER
 PLANNING DIVISION
 [email protected]
 516-822-1402

Review Stop Z ZONING
Rev No 5 Status F Date 2023-02-27 Cont ID  
Sent By cibaven Date 2023-02-27 Time 16:56 Rev Time 0.00
Received By cibaven Date 2023-02-27 Time 16:56 Sent To  
Notes
2023-02-27 16:56:02PROJEC NEEDS SITE PLAN APPROVAL BEFORE PERMITS CAN BE
 APPROVED. APPLICATION FSPR 22-24 (Z22120027) IN REVIEW.
  
 CLAUDIA D. IBAVEN
 CITY URBAN DESIGNER
 [email protected], 561-822-1402

Review Stop Z ZONING
Rev No 4 Status F Date 2023-02-08 Cont ID  
Sent By cibaven Date 2023-02-08 Time 10:22 Rev Time 0.00
Received By cibaven Date 2023-02-08 Time 10:21 Sent To  
Notes
2023-02-08 10:21:52PROJECTS NEED SITE PLAN APPROVAL BEFORE PERMITS CAN BE
 APPROVED. APPLICATION FSPR 22-24 (Z22120027) IN REVIEW.
  
 CLAUDIA D. IBAVEN
 CITY URBAN DESIGNER
 [email protected], 561-822-1402

Review Stop Z ZONING
Rev No 3 Status F Date 2022-12-08 Cont ID  
Sent By ckimmerl Date 2022-12-08 Time 09:46 Rev Time 0.00
Received By ckimmerl Date 2022-12-08 Time 09:46 Sent To  
Notes
2022-12-08 09:46:54REPEAT COMMENT:
  
 1. PROPOSED PROJECT TRIGGERS REQUIREMENTS FOR A FORMAL
 SITE PLAN REVIEW. PLEASE SUBMIT AN 2022 DOWNTOWN MASTER
 PLAN (DMP) DEVELOPMENT APPLICATION.
  
 - PERMIT ADDS MORE THAN 1000 GROSS SF BETWEEN FLOOR
 ADDITIONS, BATHROOM SPACES, AND BAR/RESTAURANT
 AMENITIES.
 - PERMIT INVOLVES IMPROVEMENTS AND ALTERATIONS TO MORE
 THAN ONE PROPERTY, BOTH 313 AND 309 CLEMATIS.
 - SCOPE OF WORK WITHIN THE PERMIT APPEARS TO INCLUDE
 THE REQUEST FOR VARIANCES FROM ESTABLISHED SETBACKS.
  
 WILL REQUIRE PLANS PLATS & REVIEW COMMITTEE ASSESSMENT,
 AND WILL BE SUBJECT TO DOWNTOWN ACTION COMMITTEE
 SPECIAL REVIEW AND VARIANCE APPROVAL.
  
 CHRIS KIMMERLY, AICP
 URBAN DESIGN PLANNER
 822.1426 [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2022-11-07 Cont ID  
Sent By ckimmerl Date 2022-11-07 Time 11:45 Rev Time 0.00
Received By ckimmerl Date 2022-11-07 Time 11:45 Sent To  
Notes
2022-11-07 11:45:41REPEAT COMMENT:
  
 1. PROPOSED PROJECT TRIGGERS REQUIREMENTS FOR A FORMAL
 SITE PLAN REVIEW. PLEASE SUBMIT AN 2022 DOWNTOWN MASTER
 PLAN (DMP) DEVELOPMENT APPLICATION.
  
 - PERMIT ADDS MORE THAN 1000 GROSS SF BETWEEN FLOOR
 ADDITIONS, BATHROOM SPACES, AND BAR/RESTAURANT
 AMENITIES.
 - PERMIT INVOLVES IMPROVEMENTS AND ALTERATIONS TO MORE
 THAN ONE PROPERTY, BOTH 313 AND 309 CLEMATIS.
 - SCOPE OF WORK WITHIN THE PERMIT APPEARS TO INCLUDE
 THE REQUEST FOR VARIANCES FROM ESTABLISHED SETBACKS.
  
 WILL REQUIRE PLANS PLATS & REVIEW COMMITTEE ASSESSMENT,
 AND WILL BE SUBJECT TO DOWNTOWN ACTION COMMITTEE
 SPECIAL REVIEW AND VARIANCE APPROVAL.
  
 CHRIS KIMMERLY, AICP
 URBAN DESIGN PLANNER
 822.1426 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2022-08-22 Cont ID  
Sent By ckimmerl Date 2022-08-22 Time 14:47 Rev Time 0.00
Received By ckimmerl Date 2022-08-22 Time 14:37 Sent To  
Notes
2022-08-22 14:47:011. PROPOSED PROJECT TRIGGERS REQUIREMENTS FOR A FORMAL
 SITE PLAN REVIEW. PLEASE SUBMIT AN 2022 DOWNTOWN MASTER
 PLAN (DMP) DEVELOPMENT APPLICATION.
  
 - PERMIT ADDS MORE THAN 1000 GROSS SF BETWEEN FLOOR
 ADDITIONS, BATHROOM SPACES, AND BAR/RESTAURANT
 AMENITIES.
 - PERMIT INVOLVES IMPROVEMENTS AND ALTERATIONS TO MORE
 THAN ONE PROPERTY, BOTH 313 AND 309 CLEMATIS.
 - SCOPE OF WORK WITHIN THE PERMIT APPEARS TO INCLUDE
 THE REQUEST FOR VARIANCES FROM ESTABLISHED SETBACKS.
  
 WILL REQUIRE PLANS PLATS & REVIEW COMMITTEE ASSESSMENT,
 AND WILL BE SUBJECT TO DOWNTOWN ACTION COMMITTEE
 SPECIAL REVIEW AND VARIANCE APPROVAL.
  
 CHRIS KIMMERLY, AICP
 URBAN DESIGN PLANNER
 822.1426 [email protected]