Review Stop AD ADDRESSING
Rev No 2 Status F Date 2023-02-14 Cont ID  
Sent By cpuell Date 2023-02-14 Time 16:35 Rev Time 0.00
Received By cpuell Date 2023-02-14 Time 16:35 Sent To  
Notes
2023-02-14 16:35:56ELECTRICAL PLANS SHOW THAT A RANGE WILL BE INSTALLED,
 AN ADDRESS WILL NEED TO BE ESTABLISHED IS ZONING
 ALLOWED FOR AN ADDITIONAL UNIT.PLEASE CONTACT
 DS_ADDRESSING OR CALL 561-805-6659 ONCE ZONING APPROVES
 THE BUILDING

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-07-07 Cont ID  
Sent By cpuell Date 2022-07-07 Time 10:23 Rev Time 0.00
Received By cpuell Date 2022-07-07 Time 10:23 Sent To  
Notes
2022-07-07 10:29:29ELECTRICAL PLANS SHOW THAT A RANGE WILL BE INSTALLED,
 AN ADDRESS WILL NEED TO BE ESTABLISHED IS ZONING
 ALLOWED FOR AN ADDITIONAL UNIT.PLEASE CONTACT
 DS_ADDRESSING OR CALL 561-805-6659 ONCE ZONING APPROVES
 THE BUILDING

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-02-08 Cont ID  
Sent By cthroop Date 2023-02-08 Time 10:46 Rev Time 0.00
Received By cthroop Date 2023-02-08 Time 06:31 Sent To  
Notes
2023-02-08 10:48:41BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1.PROVIDE A COPY OF THE CURRENT FLORIDA PRODUCT
 APPROVALS APPROVED UNDER THE 2020 FBC, FOR THE PROPOSED
 WINDOWS AND EXT. DOORS.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-08-03 Cont ID  
Sent By jgomez Date 2022-08-03 Time 17:05 Rev Time 0.00
Received By jgomez Date 2022-08-02 Time 17:44 Sent To  
Notes
2022-08-03 17:06:20RESIDENTIAL (R3) ADDITION BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22061077 809 VALLEY FORGE RD
  
 1- PROPOSED WORK AFFECTS THE LOT DRAINAGE. PROVIDE
 DRAINAGE PLAN SHOWING HOW THE SURFACE DRAINAGE IS KEPT
 WITHIN THE LOT AND NOT DIVERTED TO ADJACENT PROPERTIES.
 PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING SECTIONS: R401.3 FBC-RESIDENTIAL. SEC.
 107.2.5 CITY AMENDMENTS AND SEC. 110.9 CITY AMENDMENTS.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 2- -PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.5 FBC-ENERGY CONSERVATION.
 NOTE: PLEASE MAKE SURE CALCULATIONS ARE SIGNED BY ALL
 THE REQUIRED PARTIES, INCLUDING THE OWNER OR AUTHORIZED
 AGENT TO AVOID CONFLICT/DELAYS.
  
 3- OFFICE DOESN'T COMPLY WITH THE MINIMUM ROOM
 DIMENSION REQUIRED BY SEC. R304.2 FBC-RESIDENTIAL.
 REVISE AS REQUIRED.
  
 4- SPECIFY HOW PROVIDING HEAT TO ALL HABITABLE AREAS AS
 REQUIRED BY SEC. R303.10 FBC-RESIDENTIAL.
  
 5- ENGINEER OF RECORD TO SPECIFY ALL ROOF LIVE AND DEAD
 LOADS. CLEARLY SPECIFY TRUSS TOP CHORD LIVE AND DEAD
 LOADS AND BOTTOM CHORD LIVE AND DEAD LOADS. NOTE:
 INCLUDE THE ATTIC LIVE LOAD AS REQUIRED BY TABLE R301.5
 FBC-RESIDENTIAL. SEE FOOTNOTES "B" AND "G".
  
 6- SOUTH ELEVATION ON SHEET A-1: WINDOWS ARE LOCATED IN
 THE END ZONE NOT INTERIOR ZONE. REVISE AS REQUIRED.
 FIGURE R301.2(7) FBC-RESIDENTIAL.
 NOTE: SAME COMMENT APPLIES TO KITCHEN WINDOW ON EAST
 ELEVATION.
  
 7- SPECIFY ATTIC ACCESS SIZE AND LOCATION. SEC. R807.1
 FBC-RESIDENTIAL.
  
 8- SHEET S-2:
 A) CLARIFY CONSTRUCTION AT THE GABLE END. ROOF FRAMING
 PLAN SPECIFIES STRUCTURAL GABLE END TRUSS BUT IT ALSO
 CALLS FOR DETAIL 2/S-3. THERE IS NO DETAIL 2/S-3 BUT
 THERE IS DETAIL 1-S-3 FOR RAKE BEAM. REVISE/CLARIFY AS
 REQUIRED AND CORRECT DETAIL NUMBER IF USING RAKE BEAM
 DETAIL. SEC. 107.2.1 CITY AMENDMENTS.
  
 B) WIND RESISTANCE OF EXTERIOR SOFFITS: ENGINEER OF
 RECORD TO PROVIDE COMPLETE DETAILS AND SPECIFICATIONS
 FOR THE SOFFIT CONSTRUCTION AT PORCH AND ROOF EAVES
 SHOWING COMPLIANCE WITH SEC. R704 FBC-RESIDENTIAL.
 NOTE: IF USING STUCCO, THEN, PROVIDE SPECIFICATIONS
 SHOWING COMPLIANCE WITH ASTM C1063 (SEE TABLE 3 OF ASTM
 C1063).
  
 C) ATTIC VENTILATION CALCULATIONS CALL FOR SOFFIT VENTS
 AND RIDGE VENTS. CLEARLY SPECIFY SIZE AND LOCATION OF
 VENTS. NOTE: TYPICAL WALL SECTION ON SHEET S-3 CALL FOR
 CONTINUOUS SOFFIT VENT. SPECIFY SIZE OF SOFFIT VENT AND
 SPECIFY SIZE AND LOCATION OF RIDGE VENTS ON THE ROOF
 FRAMING PLAN.
 SEC. R806 FBC-RESIDENTIAL.
  
 9-ROOFING UNDERLAYMENT
 PROVIDE SPECIFICATIONS SHOWING HOW COMPLYING WITH THE
 NEW 2020 CODE REQUIREMENT FOR ROOFING UNDERLAYMENT.
 SEC. R905.1.1.1 FBC-RESIDENTIAL.
 NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1
 FBC-RESIDENTIAL IS GOING TO BE USED.
  
 10- BUILDING DIMENSIONS SHOWN ON THE FLOOR PLAN ON
 SHEET A-3 AND BUILDING DIMENSIONS SHOWN ON THE SURVEY
 SUBMITTED DON'T MATCH. REVISE AS REQUIRED TO MATCH.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 11- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)METAL ROOF.
  
 B)RIDGE VENTS FOR METAL ROOF AS SPECIFIED ON PLANS.
  
 C)ENTRY DOOR WITH SIDELITE AS SHOWN ON PLANS.
  
 D)SINGLE HUNG WINDOWS.
  
 E)FIXED WINDOWS.
  
 F)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
  
 G)ROOFING UNDERLAYMENT SPECIFIED ON PLANS.
  
 12- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 13- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. VALUATION WAS UPDATED TO $118,287.00. THE
 PERMIT FEE BALANCE IS $753.83
  
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-02-10 Cont ID  
Sent By jleahy Date 2023-02-10 Time 06:25 Rev Time 0.00
Received By jleahy Date 2023-02-09 Time 17:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-07-27 Cont ID  
Sent By jleahy Date 2022-07-27 Time 09:51 Rev Time 0.00
Received By jleahy Date 2022-07-27 Time 09:41 Sent To  
Notes
2022-07-27 09:55:25FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) GORUNDING ELECTRODE PER 250.32 REQUIRED AT SEPARATE
 BUILDING.
  
 2) SMOKE ALARMS REQUIRED BY FBC R314.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-09 Cont ID  
Sent By avolcy Date 2023-03-09 Time 13:19 Rev Time 0.00
Received By avolcy Date 2023-02-07 Time 12:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-08-03 Cont ID  
Sent By jgomez Date 2022-08-03 Time 17:10 Rev Time 0.00
Received By jgomez Date 2022-07-06 Time 11:10 Sent To I
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-08-03 Cont ID  
Sent By jgomez Date 2022-08-03 Time 17:10 Rev Time 0.00
Received By jgomez Date 2022-08-03 Time 17:09 Sent To  
Notes
2022-08-03 17:10:23IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-02-14 Cont ID  
Sent By medwards Date 2023-02-14 Time 10:28 Rev Time 0.00
Received By medwards Date 2023-02-14 Time 10:28 Sent To  
Notes
2023-02-14 10:29:21SEE 1ST CYCLE REVIEW COMMENTS BELOW:
  
 1) PROVIDE THE ENERGY CALCULATIONS. FEC 101.5.1.1.2
  
 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FRC R403.7.1
  
 3) PROVIDE A MECHANICAL DRAWING SHOWING THE DRYER
 EXHAUST DUCT AND TERMINATION LOCATION. FFC 107.2.1
  
 4) SHOW THE BATH EXHAUST FANS, DUCTWORK AND TERMINATION
 LOCATION. FRC M1507.4
  
 5) PROVIDE THE ANCHORING DETAILS FOR THE CONDENSATE
 UNITS. FRC M1307.2
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-07-12 Cont ID  
Sent By medwards Date 2022-07-12 Time 14:11 Rev Time 0.00
Received By medwards Date 2022-07-12 Time 14:11 Sent To  
Notes
2022-07-12 14:20:021) PROVIDE THE ENERGY CALCULATIONS. FEC 101.5.1.1.2
  
 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FRC R403.7.1
  
 3) PROVIDE A MECHANICAL DRAWING SHOWING THE DRYER
 EXHAUST DUCT AND TERMINATION LOCATION. FFC 107.2.1
  
 4) SHOW THE BATH EXHAUST FANS, DUCTWORK AND TERMINATION
 LOCATION. FRC M1507.4
  
 5) PROVIDE THE ANCHORING DETAILS FOR THE CONDENSATE
 UNITS. FRC M1307.2
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-02-09 Cont ID  
Sent By ccole Date 2023-02-09 Time 14:23 Rev Time 0.00
Received By ccole Date 2023-02-09 Time 13:58 Sent To  
Notes
2023-02-09 14:26:172ND REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22061077
 2/9/23
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET E-1 WHICH HAS THE PLUMBING RISER AND WATER
 HEATER SCHEDULE WAS SUBMITTED ELECTRONICALLY HOWEVER
 THE PLAN SHEET IS NOT DIGITALLY SIGNED AND SEALED BY
 THE ENGINEER OF RECORD AS REQUIRED BY FL. STATUTE
 471.025 AND SECTION 61G15-23.005 FAC. AS PREVIOUSLY
 NOTED THE WASHING MACHINE STANDPIPE SHALL BE 2-INCH
 HOWEVER THE PLAN IS STILL SHOWING 1-1/2 INCH- TABLE
 P3201.7 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-07-13 Cont ID  
Sent By ccole Date 2022-07-13 Time 13:30 Rev Time 0.00
Received By ccole Date 2022-07-13 Time 12:38 Sent To  
Notes
2022-07-13 13:30:301ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22061077
 7/13/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) TWO DWELLINGS ON THE SAME LOT WILL REQUIRE WATER
 USERS TO INSTALL A BACKFLOW PREVENTION ASSEMBLY AT THE
 POINT OF DELIVERY. A REDUCED PRESSURE ZONE BACKFLOW
 DEVICE WILL BE REQUIRED FOR THE WATER METER PER SECS.
 C, D, & E WEST PALM BEACH UTILITIES CROSS-CONNECTION
 MANUAL. PLEASE ADD THE MAKE AND MODEL OF THE DEVICE TO
 THE BACKFLOW PREVENTION DEVICE SCHEDULE ON SHEET P801,
 AND SUBMIT THE CIVIL PLANS REFERENCED IN THE SCHEDULE.
 PLEASE NOTE THAT A FL. LICENSED PLUMBING CONTRACTOR
 SHALL OBTAIN A SEPARATE PERMIT FOR INSTALLATION OF THE
 BACKFLOW PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB
 AND SEC. 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL
 BE TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT
 PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT.
 PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS
 DEPT.AT 561-822-2210 FOR FURTHER INFORMATION.
  
 2) E-1: CORRECT THE RISER TO SHOW A 2-INCH TRAP FOR THE
 STANDPIPE- TABLE P3101.7 FBC RES.
 3) SHEET E-1: SHOW THE LOCATION OF THE NEW WATER
 HEATER- SEC. P2801.1 FBC RES. AND PROVIDE AN EQUIPMENT
 SCHEDULE- SEC. P2801.4 FBC RES. THE EQUIPMENT SCHEDULE
 SHALL INDICATE THE MAKE AND MODEL, TYPE- TANK OR
 TANKLESS, GALLON SIZE, EFFICIENCY RATING, AND
 ELECTRICAL CIRCUITRY. A) PAN AND PAN DRAIN DETAILS ARE
 REQUIRED FOR STORAGE TANK INSTALLATIONS- SEC. P2801.6
 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2023-02-08 Cont ID  
Sent By cthroop Date 2023-02-08 Time 10:50 Rev Time 0.00
Received By cthroop Date 2023-02-08 Time 06:31 Sent To  
Notes
2023-02-08 10:53:11CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 COMMENTS FROM 1ST ROOFING REVIEW HAVE NOT BEEN
 ADDRESSED. (SEE BELOW)
  
 ROOFING REVIEW:
  
 1- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)METAL ROOF.
  
 B)RIDGE VENTS FOR METAL ROOF AS SPECIFIED ON PLANS.
  
 C)ROOFING UNDERLAYMENT SPECIFIED ON PLANS.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-08-03 Cont ID  
Sent By jgomez Date 2022-08-03 Time 17:08 Rev Time 0.00
Received By jgomez Date 2022-08-03 Time 17:07 Sent To  
Notes
2022-08-03 17:09:14ROOFING REVIEW:
  
 1- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)METAL ROOF.
  
 B)RIDGE VENTS FOR METAL ROOF AS SPECIFIED ON PLANS.
  
 C)ROOFING UNDERLAYMENT SPECIFIED ON PLANS.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-02-08 Cont ID  
Sent By cthroop Date 2023-02-08 Time 10:48 Rev Time 0.00
Received By cthroop Date 2023-02-08 Time 06:31 Sent To  
Notes
2023-02-08 10:50:002ND SIGNATURE REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: ALL PLAN PAGES
  
 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A
 VALID DIGITAL SIGNATURE.
 A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE
 IS NOT CONSIDERED A VALID DIGITAL SIGNATURE.
  
 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S.
 668.003 (3);
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
 F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS)
 F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS)
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-07-07 Cont ID  
Sent By mpeterso Date 2022-07-07 Time 13:33 Rev Time 0.00
Received By mpeterso Date 2022-07-07 Time 13:33 Sent To  
Notes
2022-07-07 13:33:437/7/22 SIGNATURE REVIEW OF PAPER PLANS/DOCUMENTS PASSED
 AND ROUTED TO STORAGE.MP

Review Stop Z ZONING
Rev No 2 Status F Date 2023-03-09 Cont ID  
Sent By AVolcy Date 2023-03-09 Time 13:09 Rev Time 0.00
Received By avolcy Date 2023-03-09 Time 13:09 Sent To  
Notes
2023-03-09 13:10:5203.09.2023 - FAILED
 THIS PROPERTY IS IN SF7. NO SECOND KITCHEN ALLOWED IN
 THE NEW GUEST HOUSE. A KITCHENETTE WITH NO STOVE IS
 PERMITTED.
 UPDATE PLANS TO CHANGE "KITCHEN" TO "KITCHENETTE" AND
 MAKE A NOTE THAT THERE WILL BE NO STOVE.
  
 **** REVIEWD BY ****
 GAISHA (ANNE CLERISSE) VOLCY
 PLANNER
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2022-07-11 Cont ID  
Sent By afowlkes Date 2022-07-11 Time 13:19 Rev Time 0.00
Received By afowlkes Date 2022-07-11 Time 13:19 Sent To  
Notes
2022-07-11 13:20:1107/11/22 PASSED - SEE NOTES ON FLOORPLAN
  
 ALEXANDER FOWLKES
 [email protected]
 5618221431


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved