Plan Review Details - Permit 22060816
| Plan Review Stops For Permit 22060816 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-08-31 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-08-31 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-08-31 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-08-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-08-10 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-08-10 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2022-08-10 14:31:05 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER; TO CORRECT ALL DATA. | | | DATA MUST REFERENCE MIAMI-DADE COUNTY NOA NO. | | | 20-0110.11 A FLAT ROOF SYSTEM NOT NOA NO. 20-0110.01 A | | | METAL PANEL ROOF SYSTEM. | | | 2. FBC B 107.2.1. PLEASE PROVIDE ENGINEER'S SIGNED AND | | | SEALED FASTENER SPACING DETAIL WITH CALCULATIONS FOR | | | PERIMETERS AND CORNERS AS PER PRODUCT APPROVAL | | | LIMITATIONS #7 OF MIAMI-DADE NOA NO.: 20-0110.11. | | | PLEASE NOTE THIS PROJECT IS LOCATED IN AN EXPOSURE C | | | CATEGORY AREA. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-07-29 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-07-29 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-07-29 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2022-07-29 09:30:57 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. SUBMITTED MIAMI-DADE COUNTY NOA 18-0409.06 COVERS | | | MULTIPLE PRODUCTS & APPROVED ASSEMBLIES: SYSTEMS E(1) | | | THROUGH E(4). SELECT SYSTEM TO BE USED ON PAGE 4 OR | | | PAGE 5. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE | | | CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | SECOND REQUEST. | | | 2. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER; TO CORRECT ALL DATA. | | | DATA MUST REFERENCE MIAMI-DADE COUNTY NOA NO. | | | 20-0110.11 A FLAT ROOF SYSTEM NOT NOA NO. 20-0110.01 A | | | METAL PANEL ROOF SYSTEM. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-06-21 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-06-21 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-06-21 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2022-06-21 08:16:26 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected]. | | | | | | 1. FBC B 107.2.1. SUBMITTED MIAMI-DADE COUNTY NOA | | | 18-0919.03 IS APPROVED FOR USE ON CONCRETE DECKS AND | | | NOT APPROVED FOR USE ON WOOD DECKS. | | | 2. FBC B 107.2.1. PLEASE PROVIDE ENGINEER'S SIGNED AND | | | SEALED FASTENER SPACING DETAIL WITH CALCULATIONS FOR | | | PERIMETERS AND CORNERS AS PER PRODUCT APPROVAL | | | LIMITATIONS #7 OF MIAMI-DADE NOA NO.: 20-0110.01. | | | PLEASE NOTE THIS PROJECT IS LOCATED IN AN EXPOSURE C | | | CATEGORY AREA. | | | 3. SUBMITTED MIAMI-DADE COUNTY NOA 18-0409.06 COVERS | | | MULTIPLE PRODUCTS & APPROVED ASSEMBLIES: SYSTEMS E(1) | | | THROUGH E(4). SELECT SYSTEM TO BE USED ON PAGE 4 OR | | | PAGE 5. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE | | | CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-08-31 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-08-31 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-08-24 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-08-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-08-10 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-08-03 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-07-29 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-07-29 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-07-22 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-06-21 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-06-21 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-06-17 |
Time |
09:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-08-31 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-08-31 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-08-31 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
|