| Plan Review Stops For Permit 22060778 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2022-09-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-30 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-30 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2022-09-30 13:58:37 | NO STRUCTURAL WORK SHOWN. SEPARATE PERMIT OR SUB-PERMIT | | | REQUIRED FOR STRUCTURAL WORK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-10-13 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-13 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-13 |
Time |
08:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-09-14 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-09-14 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-09-14 |
Time |
09:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-10-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-10-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-10-06 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-07-05 |
|
|
Cont ID |
|
| Sent By |
clfranci |
Date |
2022-07-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
clfranci |
Date |
2022-07-05 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-10-17 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-10-17 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-10-05 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-10-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-04 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-03 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-09-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-30 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-23 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-11 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-01 |
Time |
12:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2022-10-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-11 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-11 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2022-10-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-04 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-04 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2022-10-04 11:54:40 | PLEASE ADDRESS 1ST CYCLE REVIEW COMMENTS BELOW: | | | | | | 1ST REVIEW FMC | | | PERMIT: 22060778 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THERE ARE SEVERAL ISSUES WITH THE SUBMITTED DRAWING | | | FOR THE GREASE DUCT TERMINATION. THE DRAWING DOES NOT | | | GIVE ANY DETAILS FOR THE STRUCTURE THAT IS BEING | | | INSTALLED AROUND THE KEF-1, PROVIDE DETAILS AND | | | DRAWINGS FOR THIS STRUCTURE INCLUDING THE ACCESS DOORS | | | FOR THE SERVICE AND CLEANING OF THE EQUIPMENT AND | | | GREASE DUCT. THE DRAWING DOES NOT SHOW THE VEGETATION | | | IN THE AREA IN QUESTION. PROVIDE A DETAIL SHOWING THE | | | ACCESS DOORS ABOVE THIS AREA. SHEET H-7 INDICATES THIS | | | STRUCTURE IS SITTING ON THE CONCRETE SLAB AND THE | | | MEASUREMENT FROM THE SLAB TO THE BOTTOM OF THE LOUVER | | | IS A MINIMUM OF 10 FEET. THIS MEASUREMENT SHOULD BE | | | FROM THE WALKING PAVERS AND NOT FROM THE CONCRETE SLAB | | | AS WE HAVE NO WAY OF KNOWING HOW HIGH FROM THE SLAB THE | | | PAVERS ARE RAISED. WE DO KNOW THAT THE LOUVER SHOULD BE | | | AT LEAST 10 FEET FROM ADJOINING GRADE. FMC 506.3.13.3. | | | FBC 107.3.5 | | | | | | 2) HOW IS THIS STRUCTURE THAT IS SUPPORTING THE EXHAUST | | | LOUVER SECURED? FBC 107.3.5 | | | | | | 3) PROVIDE A DETAIL FOR THE SLEEVE WHERE THE GREASE | | | DUCT PENETRATES THE ROOF, HOW IS THIS CAPPED? FBC | | | 107.3.5 | | | | | | 4) PROVIDE A DETAIL SHOWING THE CLEARANCE FROM THE | | | BUILDING TO THE EXHAUST FAN AND THE GREASE EXHAUST | | | DUCTWORK. FBC 107.3.5 | | | | | | 5) SHOW THE DEPTH OF THE STRUCTURE FROM THE BUILDING. | | | | | | FMC 503.13.3 EXCEPTION: EXHAUST OUTLETS SHALL TERMINATE | | | NOT LESS THAN 5 FEET (1524 MM) HORIZONTALLY FROM PARTS | | | OF THE SAME OR CONTIGUOUS BUILDING, AN ADJACENT | | | BUILDING, ADJACENT PROPERTY LINE AND AIR INTAKE | | | OPENINGS INTO A BUILDING WHERE AIR FROM THE EXHAUST | | | OUTLET DISCHARGES AWAY FROM SUCH LOCATIONS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-08-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-29 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-29 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2022-08-29 11:49:53 | 1ST REVIEW FMC | | | PERMIT: 22060778 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THERE ARE SEVERAL ISSUES WITH THE SUBMITTED DRAWING | | | FOR THE GREASE DUCT TERMINATION. THE DRAWING DOES NOT | | | GIVE ANY DETAILS FOR THE STRUCTURE THAT IS BEING | | | INSTALLED AROUND THE KEF-1, PROVIDE DETAILS AND | | | DRAWINGS FOR THIS STRUCTURE INCLUDING THE ACCESS DOORS | | | FOR THE SERVICE AND CLEANING OF THE EQUIPMENT AND | | | GREASE DUCT. THE DRAWING DOES NOT SHOW THE VEGETATION | | | IN THE AREA IN QUESTION. PROVIDE A DETAIL SHOWING THE | | | ACCESS DOORS ABOVE THIS AREA. SHEET H-7 INDICATES THIS | | | STRUCTURE IS SITTING ON THE CONCRETE SLAB AND THE | | | MEASUREMENT FROM THE SLAB TO THE BOTTOM OF THE LOUVER | | | IS A MINIMUM OF 10 FEET. THIS MEASUREMENT SHOULD BE | | | FROM THE WALKING PAVERS AND NOT FROM THE CONCRETE SLAB | | | AS WE HAVE NO WAY OF KNOWING HOW HIGH FROM THE SLAB THE | | | PAVERS ARE RAISED. WE DO KNOW THAT THE LOUVER SHOULD BE | | | AT LEAST 10 FEET FROM ADJOINING GRADE. FMC 506.3.13.3. | | | FBC 107.3.5 | | | | | | 2) HOW IS THIS STRUCTURE THAT IS SUPPORTING THE EXHAUST | | | LOUVER SECURED? FBC 107.3.5 | | | | | | 3) PROVIDE A DETAIL FOR THE SLEEVE WHERE THE GREASE | | | DUCT PENETRATES THE ROOF, HOW IS THIS CAPPED? FBC | | | 107.3.5 | | | | | | 4) PROVIDE A DETAIL SHOWING THE CLEARANCE FROM THE | | | BUILDING TO THE EXHAUST FAN AND THE GREASE EXHAUST | | | DUCTWORK. FBC 107.3.5 | | | | | | 5) SHOW THE DEPTH OF THE STRUCTURE FROM THE BUILDING. | | | | | | FMC 503.13.3 EXCEPTION: EXHAUST OUTLETS SHALL TERMINATE | | | NOT LESS THAN 5 FEET (1524 MM) HORIZONTALLY FROM PARTS | | | OF THE SAME OR CONTIGUOUS BUILDING, AN ADJACENT | | | BUILDING, ADJACENT PROPERTY LINE AND AIR INTAKE | | | OPENINGS INTO A BUILDING WHERE AIR FROM THE EXHAUST | | | OUTLET DISCHARGES AWAY FROM SUCH LOCATIONS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-11 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-11 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2022-07-11 10:49:19 | SHEET H-6 SHOWS THE KEF-1 EXHAUST TERMINATION | | | APPROXIMATELY 6 FT. 3.75 INCHES FROM THE PARKING GARAGE | | | WALL AND 1 FT 8.75 INCHES FROM THE WALKING AREA OF THE | | | GREEN SPACE. THIS DOES NOT MEET FMC 506.3.13.3. THE | | | GREEN SPACE IS AN AREA ON THE ROOF THAT THE EMPLOYEES | | | CAN SIT AND ENJOY THE OUTDOORS. THIS WOULD BE | | | CONSIDERED GRADE LEVEL. PLEASE REVISE THE DRAWING SO | | | THAT IT REFLECTS FMC 506.3.13.3 | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-10-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-11 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-11 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2022-10-05 16:29:20 | DIGITALLY SIGNED FILE IN SIGNATURES FOLDER |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2022-10-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-04 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-04 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2022-10-04 11:55:44 | PLEASE ADDRESS 1ST CYCLE COMMENTS BELOW: | | | | | | SEE ORIGINAL COMMENT BELOW: | | | | | | THE DRAWINGS ARE MISSING THE DIGITAL SIGNATURE OF THE | | | DESIGNERS. FBC 107.2.1 FS 471/481 | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-08-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-29 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-29 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2022-08-29 12:01:27 | SEE ORIGINAL COMMENT BELOW: | | | | | | THE DRAWINGS ARE MISSING THE DIGITAL SIGNATURE OF THE | | | DESIGNERS. FBC 107.2.1 FS 471/481 | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-11 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-11 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2022-07-11 10:52:08 | THE DRAWINGS ARE MISSING THE DIGITAL SIGNATURE OF THE | | | DESIGNERS. FBC 107.2.1 FS 471/481 | | | | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-10-13 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2022-10-13 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2022-10-13 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2022-10-13 17:40:00 | PROVISO: ANY NEW MECHANICAL EQUIPMENT ON ROOF SHALL BE | | | SCREENES FROM VIEW WITH A SCREEN AS TALL AS THE | | | EQUIPMENT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
2022-09-22 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-09-22 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2022-09-22 11:22:38 | PROVISO: ALL NEW MECHANICAL OR ROOFTOP EQUIPMENT SHALL | | | BE ENCLOSED OR SCREENED FROM VIEW WITH A SCREEN EQUAL | | | TO THE HEIGHT OF THE EQUIPMENT. |
|
|