Plan Review Details - Permit 22060728
Plan Review Stops For Permit 22060728
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-10-12 Cont ID  
Sent By shill Date 2022-10-12 Time 12:32 Rev Time 0.00
Received By shill Date 2022-10-12 Time 12:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-07-20 Cont ID  
Sent By shill Date 2022-07-20 Time 14:42 Rev Time 0.00
Received By shill Date 2022-07-20 Time 13:14 Sent To  
Notes
2022-07-20 14:44:33****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. FBC 109, PROVIDE A NEW PERMIT APPLICATION WHICH
 SPECIFICALLY STATES WHAT ITEMS ARE INCLUDED. THE PLANS
 SHOW A POOL, SPA, POND, AND POOL DECK. VALUE IS TO
 INCLUDE ALL LABOR, MATERIALS, OVERHEAD, PROFIT,
 INCLUDING ITEMS PROVIDED BY OTHERS.
  
 WHEN RESUBMITTING, PLEASE REQUEST THAT FEES PAID ON
 22070095 AND 22070091 BE MOVED TO OTHER PERMITS. IF NO
 FEES ARE DUE ON ANY OTHER PERMITS, PLEASE REQUEST A
 REFUND IF NO OTHER PERMIT APPLICATIONS WILL BE
 SUBMITTED.
  
 2. THIS PERMIT WILL BE ISSUED WITH PROVISO, POOL
 EQUIPMENT TO MATCH HOUSE ELEVATION OF 9' NAVD88.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-10-06 Cont ID  
Sent By ppetty Date 2022-10-06 Time 08:37 Rev Time 0.00
Received By ppetty Date 2022-10-06 Time 08:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-07-06 Cont ID  
Sent By mpeterso Date 2022-07-06 Time 15:55 Rev Time 0.00
Received By mpeterso Date 2022-07-06 Time 15:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2022-12-22 Time   Rev Time 0.00
Received By lmarchan Date 2022-12-21 Time 16:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-10-12 Cont ID  
Sent By shill Date 2022-10-12 Time 12:32 Rev Time 0.00
Received By shill Date 2022-09-22 Time 08:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-20 Cont ID  
Sent By shill Date 2022-07-20 Time 14:44 Rev Time 0.00
Received By shill Date 2022-06-15 Time 10:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-12-22 Cont ID  
Sent By ccole Date 2022-12-22 Time 16:32 Rev Time 0.00
Received By ccole Date 2022-12-22 Time 15:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-09-26 Cont ID  
Sent By ccole Date 2022-09-26 Time 17:17 Rev Time 0.00
Received By ccole Date 2022-09-26 Time 16:46 Sent To  
Notes
2022-09-26 17:57:132ND REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22060728
 9/26/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. COMMENTS FROM THE 1ST
 REVIEW STILL EXIST. PLEASE C
  
 1) SHEET 6: PROVIDE TDH CALCULATIONS FOR THE POOL AND
 THE SPA- SECS. 4.4.9, 4.4.9.1 ANSI/APSP/ICC-7 &
 R4501.7.2 & R4501.7.3 FBC RES.
  
 2) SHEET 6: THE PERMIT APPLICATION INDICATES "PER PLAN"
 SO IT ASSUMED THAT THE POOL, SPA, AND POND SHOWN ON THE
 PLAN WILL BE PERMITTED TOGETHER. THE PLANS SHOW THE
 SAME RECIRCULATION PUMP USED FOR BOTH THE POOL AND SPA
 HOWEVER THE FLOW RATE CALCULATIONS SHOWN ON THE SHEET 6
 APPEAR TO BE FOR THE POOL ONLY. PLEASE REFER TO YOUR
 SPECIFICATIONS INFORMATION ON SHEET 2 WHICH LISTS THE
 SPA VOLUME AT 1,926 GALLONS AND 4309 GALLONS (POND
 GALLONS NOT PROVIDED). PLEASE REVISE THE FLOW RATE
 CALULATIONS TO INCLUDE THE SPA AND MARK UP THE PUMP
 CURVE ON THE SHEET TO SHOW THE TDH AND FLOW RATE OF THE
 SYSTEM- SECS. 4.4.9, 4.4.9.1 ANSI/APSP/ICC-7 &
 R4501.7.2 & R4501.7.3 FBC RES.
  
 3) THE POOL, SPA, AND POND ARE BEING CONSTRUCTED IN A
 FLOOD HAZARD ZONE. PLEASE PROVIDE HYDROSTATIC RELIEF
 DEVICES TO BE LOCATED AT THE LOW POINTS OF THE MAIN
 DRAINS- SEC. R4501.21.4 FBC RES.
  
 4) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE
 RECIRCULATION EQUIPMENT- PUMP, FILTER, CHLORINATOR- AND
 THE UNBLOCKABLE DRAIN- SECS. R4501.6.2 & R4501.6.6 FBC
 RES.
  
 NEW COMMENT.
  
 1) SHEET 2 SHOWS POOL VOLUME AT 9824 GALLONS AND SPA
 VOLUME AT 1926 GALLONS- TOTAL- 11750 GALLONS
 RECIRCULATION SYSTEM. THE FLOW RATE CALCS ON SHEET 6
 SHOW THE POOL VOLUME AT 13156 GALLONS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-06-24 Cont ID  
Sent By ccole Date 2022-06-24 Time 14:57 Rev Time 0.00
Received By ccole Date 2022-06-24 Time 14:36 Sent To  
Notes
2022-06-24 14:57:561ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22060728
 6/24/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 6: PROVIDE TDH CALCULATIONS FOR THE POOL AND
 THE SPA- SECS. 4.4.9, 4.4.9.1 ANSI/APSP/ICC-7 &
 R4501.7.2 & R4501.7.3 FBC RES.
  
 2) SHEET 6: THE PERMIT APPLICATION INDICATES "PER PLAN"
 SO IT ASSUMED THAT THE POOL, SPA, AND POND SHOWN ON THE
 PLAN WILL BE PERMITTED TOGETHER. THE PLANS SHOW THE
 SAME RECIRCULATION PUMP USED FOR BOTH THE POOL AND SPA
 HOWEVER THE FLOW RATE CALCULATIONS SHOWN ON THE SHEET 6
 APPEAR TO BE FOR THE POOL ONLY. PLEASE REFER TO YOUR
 SPECIFICATIONS INFORMATION ON SHEET 2 WHICH LISTS THE
 SPA VOLUME AT 1,926 GALLONS AND 4309 GALLONS (POND
 GALLONS NOT PROVIDED). PLEASE REVISE THE FLOW RATE
 CALULATIONS TO INCLUDE THE SPA AND MARK UP THE PUMP
 CURVE ON THE SHEET TO SHOW THE TDH AND FLOW RATE OF THE
 SYSTEM- SECS. 4.4.9, 4.4.9.1 ANSI/APSP/ICC-7 &
 R4501.7.2 & R4501.7.3 FBC RES.
  
 3) THE POOL, SPA, AND POND ARE BEING CONSTRUCTED IN A
 FLOOD HAZARD ZONE. PLEASE PROVIDE HYDROSTATIC RELIEF
 DEVICES TO BE LOCATED AT THE LOW POINTS OF THE MAIN
 DRAINS- SEC. R4501.21.4 FBC RES.
  
 4) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE
 RECIRCULATION EQUIPMENT- PUMP, FILTER, CHLORINATOR- AND
 THE UNBLOCKABLE DRAIN- SECS. R4501.6.2 & R4501.6.6 FBC
 RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2022-11-17 Cont ID  
Sent By shill Date 2022-11-17 Time 09:26 Rev Time 0.00
Received By shill Date 2022-11-17 Time 09:26 Sent To  
Notes
2022-11-17 09:26:13INSPECTIONS
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-12-22 Cont ID  
Sent By ccole Date 2022-12-22 Time 16:32 Rev Time 0.00
Received By ccole Date 2022-12-22 Time 16:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-10-06 Cont ID  
Sent By ppetty Date 2022-10-06 Time 08:47 Rev Time 0.00
Received By ppetty Date 2022-10-06 Time 08:47 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-06-24 Cont ID  
Sent By ccole Date 2022-06-24 Time 15:37 Rev Time 0.00
Received By ccole Date 2022-06-24 Time 14:36 Sent To  
Notes
2022-06-24 15:38:21SIGNATURE REVIEW
 PERMIT- 22060728
 6/24/2022
  
 1) SHEET L1.1 IS NOT DIGITALLY SIGNED AND SEALED BY THE
 LANDSCAPE ARCHITECT OF RECORD WHO PREPARED THE DRAWING-
 FL. STATUTE 481.321AND SEC. 61G1-16.005 FAC.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2022-09-30 Cont ID  
Sent By afowlkes Date 2022-09-30 Time 13:21 Rev Time 0.00
Received By afowlkes Date 2022-09-30 Time 13:21 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-06-17 Cont ID  
Sent By afowlkes Date 2022-06-17 Time 15:08 Rev Time 0.00
Received By afowlkes Date 2022-06-17 Time 15:08 Sent To  
Notes
2022-06-17 15:12:1206/17/22 FAILED - NEED TO SHOW HOW FAR SET BACK THE
 POOL EQUIPMENT IS.
  
 ADDITIONALLY, PLEASE CLARIFY IF THE AREA BETWEEN THE
 POOL AND SOUTH WALL IS PAVED. IF SO, IT MUST BE
 DESIGNTATED TO DRAIN AWAY FROM THE POOL BUT NOT ONTO
 ADJACENT PROPERTIES
  
 ALEXANDER FOWLKES
 5618221431
 [email protected]


Account Summary | Usage Policy | Privacy Policy