| Plan Review Stops For Permit 22060698 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-07-12 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-07-12 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-07-12 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-07-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-07-06 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-07-06 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-07-12 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-07-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2022-07-12 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2022-07-12 10:28:27 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-06-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2022-06-16 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2022-06-24 09:49:42 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-07-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-07-08 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-07-08 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-24 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-24 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2022-06-24 14:22:29 | 1ST REVIEW FBC-2020 FUEL GAS | | | PERMIT- 22060698 | | | 6/24/2022 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) GAS RISER DRAWING: THE 3/4-INCH STEEL PIPE RISER | | | FROM THE MAIN TO THE UG PE FOR THE GENERATOR IS | | | UNDERSIZED BASED ON THE SIZING TABLE ON THE PLAN- TABLE | | | 6.2.1 (E) NFPA 54. BASED ON THE TABLE, A MINIMUM 1-INCH | | | PIPE IS REQUIRED. | | | | | | 2) GAS RISER: PROVIDE THE SIZE OF THE STEEL PIPE FROM | | | THE METER TO THE 1ST TEE- TABLE 6.2.1(E) NFPA 54. | | | | | | 3) GAS RISER: CORRECT THE TOTAL LOAD TO INDICATE | | | 2,760,000 BTU'S- SEC. 402.2 & 402.3 FBC FG. | | | | | | 4) PROVIDE A SITE PLAN SHOWING THE LOCATIONS OF THE | | | GENERATOR AND PE SUPPLY PIPE RUN FROM THE METER- SEC. | | | 404.17.1 FBC FG. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-07-15 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-07-15 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-07-06 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-15 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2022-07-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-07-08 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-07-08 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-24 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-24 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-24 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-24 |
Time |
14:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-07-15 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-07-15 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-06-24 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-06-24 |
Time |
09:24 |
Sent To |
|
|
| Notes |
|
|