Plan Review Details - Permit 22060637
Plan Review Stops For Permit 22060637
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-06-15 Cont ID  
Sent By cpuell Date 2022-06-15 Time 11:44 Rev Time 0.00
Received By cpuell Date 2022-06-15 Time 11:44 Sent To  
Notes
2022-06-15 11:45:04ADDRESS APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-11-18 Cont ID  
Sent By rmcdouga Date 2022-11-18 Time 13:41 Rev Time 0.00
Received By rmcdouga Date 2022-11-18 Time 13:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-10-18 Cont ID  
Sent By rmcdouga Date 2022-10-18 Time 10:39 Rev Time 0.00
Received By rmcdouga Date 2022-10-17 Time 12:54 Sent To  
Notes
2022-10-18 14:14:57THE PRODUCT APPROVALS FOR THE WINDOWS AND DOORS HAVE
 BEEN DEFERRED. THEY ARE REQUIRED TO BE SUBMITTED AND
 APPROVED BEFORE THE CAN BE INSTALLED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-09-08 Cont ID  
Sent By rmcdouga Date 2022-09-08 Time 17:33 Rev Time 0.00
Received By rmcdouga Date 2022-09-08 Time 16:16 Sent To  
Notes
2022-09-08 17:33:38PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE DESCRIPTION OF WORK NEEDS TO INCLUDE THE POOL
 CABANA IF IT IS TO BE PART OF THIS PERMIT. THE VALUE OF
 THE CABANA NEEDS TO BE INCLUDED WITH THIS PERMIT IF YOU
 WANT IT TO BE INCLUDED. YOU HAVE THE OPTION TO DO THE
 CABANA UNDER A SEPERATE IF YOU WANT. PLEASE CLARIFY.
 FBC 107.2.1
  
 2) VERIFY THE SQFT OF THE ATTACHED GARAGE. THE SQFT OF
 THE GARAGE IS SPECIFIED AS 488 SQFT ON THE ELEVATION
 CERTIFICATE. THIS IS DIFFERENT FROM THE FLOOR PLAN
 A.1.1 (BLDG DATA= 552 SQFT) AND THE SITE PLAN A.0.1 (
 FLOOD VENT CALCULATIONS= 546 SQFT). THE INSTRUCTIONS
 FOR COMPLETING THE ELEVATION CERTIFICATE FROM FEMA FOR
 ITEM A9 A) SAYS TO TAKE THE MEASUREMENTS FROM THE
 OUTSIDE OF THE GARAGE. FBC 107.2.1
  
 3) AN ELEVATION CERTIFICATE IS REQUIRED FOR EACH
 SEPARATE BUILDING. ONE FOR THE THE HOUSE AND ANOTHER
 FOR THE CABANA. [ THE ELEVATION CERTIFICATE THAT WAS
 SUBMITTED NEEDS CORRECTIONS. SEE THE NFIP REVIEW STOP.
 ] SUBMIT A PRE-CONSTRUCTION ELEVATION CERTIFICATE BASED
 ON THE CONSTRUCTION DRAWINGS THAT SHOWS COMPLIANCE WITH
 THE CITY'S FLOOD ORDINANCE. TWO ADDITIONAL ELEVATION
 CERTIFICATES WILL BE REQUIRES. AN UNDER CONSTRUCTION EC
 WILL BE REQUIRED WHEN THE FLOOR SLABS ARE IN PLACE AND
 A FINAL EC WHEN THE CONSTRUCTION IS FINISHED. CITY OF
 WEST PALM BEACH FLOOD ORDINANCE.
  
 4) SUBMIT THE MANUFACTURER'S SPECIFICATIONS AND
 INSTALLATION INSTRUCTIONS FOR THE PREFABRICATED
 VENTLESS FIREPLACES. FBC 107.2.1
  
 5) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH
 OF THE REVIEW COMMENTS HAS BEEN ADDRESSED.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-07-21 Cont ID  
Sent By rmcdouga Date 2022-07-21 Time 10:14 Rev Time 0.00
Received By rmcdouga Date 2022-07-20 Time 07:42 Sent To  
Notes
2022-07-21 08:30:21PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THERE ARE NOTES ON THE COVERSHEET (A-0.0) UNDER THE
 PRODUCT APPROVAL & SHOP DRAWING HEADER STATING THAT THE
 ROOFING, WINDOWS AND DOORS WILL BE UNDER SEPARATE
 PERMITS. IF YOU ARE GOING TO DO THIS YOU WILL NEED TO
 PROVIDE THE COST OF EACH OF THESE ITEMS SO THEY CAN BE
 DEDUCTED FROM THE COST OF THE MAIN HOUSE, GARAGE AND
 POOL CABANA. THE PRODUCT APPROVALS FOR THESE ITEMS WILL
 NEED TO BE SUBMITTED WHEN APPLICATIONS FOR THE SEPARATE
 ROOFING OR THE WINDOW/DOOR PERMITS ARE SUBMITTED. THE
 PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD BEFORE
 BEING SUBMITTED FOR PLAN REVIEW. THESE SEPARATE PERMITS
 WILL NOT BE TURN-AROUND SINCE THE PRODUCT APPROVALS ARE
 REQUIRED TO BE REVIEWED BY THE CITY PLAN EXAMINER.
 YOU ALSO HAVE THE OPTION TO DEFER THE PRODUCT APPROVAL
 SUBMITTALS AND SUBMIT THEM FOR REVIEW UNDER THE MAIN
 PERMIT AT A LATER DATE. IF YOU USE THIS OPTION THE
 DESIGNER WILL NEED TO LIST THE ITEMS THAT WILL BE
 DEFERRED ON THE PLANS. WHEN THE PRODUCT APPROVALS FOR
 THE ITEMS HAVE BEEN SUBMITTED AND APPROVED BT THE CITY
 THEN THE ROOFING SUB-PERMITS CAN BE ISSUED. THE WINDOWS
 AND DOORS WILL BE COVERED UNDER THE MASTER PERMIT. FBC
 AMENDMENTS 107.3.4.1 DEFERRED SUBMITTALS. FOR THE
 PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE
 DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT
 SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE
 TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
 SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL
 HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 2) THIS PROJECT IS LOCATED IN A SFHA (SPECIAL FLOOD
 HAZARD AREA). THE FLOOD ZONE IS AE AND THE BFE (BASE
 FLOOD ELEVATION) IS 6'/7' NAVD 88. AS OF OCTOBER 5TH,
 2017 THE CITY HAS ADOPTED NEW FLOOD INSURANCE RATE MAPS
 WHICH USE NAVD 88 AS THE VERTICAL DATUM. THE CITY ALSO
 ADOPTED A 2' FREEBOARD WHICH REQUIRES THE FINISH FLOOR
 AND EQUIPMENT TO BE A MINIMUM OF TWO FEET ABOVE THE
 BFE. THIS MEANS THAT THE DFE (DESIGN FLOOD ELEVATION)
 FOR THIS PROJECT IS 9' NAVD 88. THE LOWEST FINISH FLOOR
 ELEVATION FOR THE HABITABLE SPACE AND THE EQUIPMENT IS
 REQUIRED TO BE AT OR ABOVE 9' NAVD 88. THE GARAGE AND
 STORAGE CAN BE BELOW BFE, IF FLOOD VENTS ARE INSTALLED
 AND NO MATERIALS OR EQUIPMENT THAT CAN BE DAMAGED BY
 FLOOD WATERS ARE BELOW BFE. SHOW COMPLIANCE WITH THESE
 REQUIREMENTS ON THE PLANS. SPECIFY ALL ELEVATIONS IN
 NAVD 88. FBC-R 322
  
 3) THE ELEVATION OF THE GARAGE IS SPECIFIED AS 8.5'
 NAVD WHICH IS BELOW THE REQUIRED 9' DFE. SUBMIT
 CONSTRUCTION DRAWINGS THAT SHOW FLOOD VENTS AND THAT
 EVERYTHING BELOW THE DFE IS OF MATERIALS THAT ARE NOT
 SUSCEPTIBLE TO DAMAGE FROM FLOOD WATERS. FBC-R322.2.2
  
 4) SUBMIT A PRE-CONSTRUCTION ELEVATION CERTIFICATE
 BASED ON THE CONSTRUCTION DRAWINGS THAT SHOWS
 COMPLIANCE WITH THE CITY'S FLOOD ORDINANCE. TWO
 ADDITIONAL ELEVATION CERTIFICATES WILL BE REQUIRES. AN
 UNDER CONSTRUCTION EC WILL BE REQUIRED WHEN THE FLOOR
 SLABS ARE IN PLACE AND A FINAL EC WHEN THE CONSTRUCTION
 IS FINISHED. CITY OF WEST PALM BEACH FLOOD ORDINANCE.
  
 5) THE ELEVATION DRAWINGS ON SHEET A-6.1, A-6.2, A-6.3
 AND THE BUILDING SECTIONS ON SHEETS A-7.1, A-7.2 AND
 A-7.3 SPECIFY THAT THE TOP OF THE FIRST FLOOR SLAB IS
 BFE + 1' . IT IS ACTUALLY REQUIRED TO BE BFE + 2' PER
 THE CITY'S FLOOD ORDINANCE. PLEASE CORRECT.
  
 6) SUBMIT A SIGNED AND SEALED COPY OF THE SOILS REPORT
 MENTIONED IN THE FOUNDATION NOTES ON SHEET S-4. FBC
 107.2.1
  
 7) AN EGRESS DOOR THAT MEETS THE REQUIREMENTS OF
 FBC-R311.2 IS REQUIRED. R311.2 EGRESS DOOR. NOT LESS
 THAN ONE EGRESS DOOR SHALL BE PROVIDED FOR EACH
 DWELLING UNIT. THE EGRESS DOOR SHALL BE SIDE-HINGED,
 AND SHALL PROVIDE A CLEAR WIDTH OF NOT LESS THAN 32
 INCHES (813 MM) WHERE MEASURED BETWEEN THE FACE OF THE
 DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES (1.57
 RAD). THE CLEAR HEIGHT OF THE DOOR OPENING SHALL BE NOT
 LESS THAN 78 INCHES (1981 MM) IN HEIGHT MEASURED FROM
 THE TOP OF THE THRESHOLD TO THE BOTTOM OF THE STOP.
 OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE
 MINIMUM DIMENSIONS. EGRESS DOORS SHALL BE READILY
 OPENABLE FROM INSIDE THE DWELLING WITHOUT THE USE OF A
 KEY OR SPECIAL KNOWLEDGE OR EFFORT.
  
 8) SUBMIT THE MANUFACTURER'S SPECIFICATIONS AND
 INSTALLATION INSTRUCTIONS FOR THE VENTLESS FIREPLACES.
 FBC 107.2.1
  
 9) SUBMIT THE MANUFACTURER'S SPECIFICATIONS AND
 INSTALLATION INSTRUCTIONS FOR THE GAS GRILL AT THE
 SUMMER KITCHEN. FBC 107.2.1
  
 10) SUBMIT THE MANUFACTURER'S SPECIFICATIONS AND
 INSTALLATION INSTRUCTIONS FOR THE ELEVATOR AND SPECIFY
 THE LOCATION OF THE ELEVATOR EQUIPMENT. INDICATE HOW
 THE EQUIPMENT CAN BE ACCESSED FOR SERVICE AND
 REPLACEMENT. FBC 107.2.1
  
 11) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH
 OF THE REVIEW COMMENTS HAS BEEN ADDRESSED.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-07-04 Cont ID  
Sent By fgiaquin Date 2022-07-04 Time 13:56 Rev Time 0.00
Received By fgiaquin Date 2022-07-01 Time 21:34 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2022-08-23 Cont ID  
Sent By rrossano Date 2022-08-23 Time   Rev Time 0.00
Received By rrossano Date 2022-08-23 Time   Sent To  
Notes
2022-08-23 10:17:46UTILITY TIE-INS TO EXISTING SERVICES ARE BEING
 COORDINATED WITH MARK HURLEY AT PUBLIC UTILITIES
 CUSTOMER SERVICES.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2022-06-27 Cont ID  
Sent By rrossano Date 2022-06-27 Time   Rev Time 0.00
Received By rrossano Date 2022-06-27 Time   Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2022-08-23 Cont ID  
Sent By ccole Date 2022-08-23 Time 15:28 Rev Time 0.00
Received By ccole Date 2022-08-23 Time 12:18 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-06-24 Cont ID  
Sent By ccole Date 2022-06-24 Time 07:43 Rev Time 0.00
Received By ccole Date 2022-06-23 Time 14:43 Sent To  
Notes
2022-06-24 07:45:181ST REVIEW FBC-2020 RES. GAS
 PERMIT- 22060637
 6/23/22
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. PLEASE REVIEW THE COMMENTS
 AND NOTE THAT INSTALLATIONS OF THE GAS PIPING AND
 GAS-FIRED APPLIANCES CAN BE UNDER A SEPARATE PERMIT BY
 REQUEST.
  
 1) P1.1. & P3.2: PLEASE NOTE THAT SEPARATE PERMITS ARE
 REQUIRED FOR THE GENERATOR AND THE POOL HEATER- SEC.
 105.1 & 107.2.1 WPB.
 2) P1.1 & P3.2- FLOOD ZONE HAZARD: THE PROPERTY APPEARS
 TO BE IN AN AE FLOOD HAZARD ZONE. ACCORDING TO SECTION
 R322.1.6 FBC RES THE GAS PIPING AND GAS-FIRED
 APPLIANCES AND EQUIPMENT SHALL BE INSTALLED AT OR ABOVE
 THE ELEVATION REQUIRED IN SECTION R322.2 FBC RES.
 PLEASE PROVIDE NOTES AND DETAILS VERIFYING COMPLIANCE
 FOR THE WATER HEATERS, POOL HEATERS, GENERATOR, FIRE
 PITS, AND BBQ GRILL
 3) P1.1 & P3.2: PROVIDE CLEARANCE DISTANCE MEASUREMENTS
 FOR THE GAS WATER HEATERS TO THE WINDOWS- SECS. G2427.8
 & G2448.1 FBC RES.
 4) P3.2 GAS RISER: PROVIDE THE CORRECT PIPE SIZING
 TABLES FOR THE NATURAL GAS SYSTEM. THE TABLES SHOWN ON
 THE PLAN- TABLE 16.1 NFPA 58 AND TABLE 402.4(28) FBC FG
 ARE FOR LP GAS- SECS. G2413.3 & G2413.4 FBC RES, &
 402.3 & 402.4 FBC FG. PLEASE INCLUDE THE TABLES FOR THE
 2.0 PSI PE AND SCHEDULE 40 METALLIC, AND THE LOW
 PRESSURE PE, SCHEDULE 40 METALLIC, AND ANY OTHER LO
 PRESSURE PIPING NOT IDENTIFIED ON THE RISER.
 5) P3.2: THE RISER APPEARS TO SHOW A 1-INCH SCHEDULE 40
 METALLIC SUPPLY PIPE FROM THE METER TO THE 2-INCH PE
 WHICH WOULD BE UNDERSIZED PER TABLE G2413.4(2) FBC RES
 & 402.4(5) FBC FG. BASED ON THE TABLE A 2-INCH PIPE IS
 REQUIRED.
 6) P3.2: SHOW THE TYPES AND SIZES OF SUPPLY PIPING FROM
 PE TO THE POOL HEATER, GENERATOR, BBQ GRILL,
 FIREPLACES, GAS WATER HEATERS- SECS.G2413.3 & G2413.4
 FBC RES & 402.3 & 402.4 FBC FG.
 7) P3.2: INDICATE THE MAKES AND MODELS OF REGULATORS TO
 BE INSTALLED ON THE SYSTEM AND SUBMIT MANUFACTURER'S
 SPECIFICATIONS MARKED UP TO SHOW THE SELECTED MODELS,
 AND INPUT AND OUT PIPE SIZES AND PRESSURES- SECTION
 G2421.2 FBC RES.
 8) P3.2: FIRE PITS ARE INCORRECTLY LABELED AS FIRE
 PLACES ON THE RISER- SEC. 107.2.1 WPB.
 9) P3.2: PROVIDE MANUFACTURER'S SPECIFICATIONS AND
 INSTALLATION MANUALS FOR THE VENTLESS FIREPLACES, BBQ
 GRILL, TANKLESS WATER HEATER, AND THE OUTDOOR FIRE
 PITS- SECS G2445.1, G2447.1, G2448.1, G2454.1 FBC RES.
 10) P3.2: INDICATE HOW COMBUSTION AIR WILL BE PROVIDED
 TO THE VENTLESS FIREPLACES AND PROVIDE CALCULATIONS-
 SEC. G22407.1 FBC RES.
 11) P3.2: PROVIDE AN ELEVATION VIEW DRAWING OF THE BBQ
 GRILL SHOWING CLEARANCES TO COMBUSTIBLES AND OVERHEAD
 CONSTRUCTION PER THE MANUFACTURER'S RECOMMENDATIONS.
 PLEASE NOTE THAT INSTALLATION OF AN EXHAUST HOOD AND
 DUCT SYSTEM MAY BE REQUIRED BASED ON MANUFACTURER'S
 INSTALLATION GUIDELINES- SECS. G2408.1 & G2447.1 FBC
 RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-07-13 Cont ID  
Sent By amhamilt Date 2022-07-13 Time 10:57 Rev Time 0.00
Received By amhamilt Date 2022-07-13 Time 10:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-11-18 Cont ID  
Sent By rmcdouga Date 2022-11-18 Time 13:41 Rev Time 0.00
Received By rmcdouga Date 2022-11-16 Time 10:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-10-20 Cont ID  
Sent By lmarchan Date 2022-10-20 Time 16:39 Rev Time 0.00
Received By lmarchan Date 2022-10-11 Time 15:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-09-14 Cont ID  
Sent By rmcdouga Date 2022-09-14 Time 17:15 Rev Time 0.00
Received By rmcdouga Date 2022-08-18 Time 07:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-21 Cont ID  
Sent By rmcdouga Date 2022-07-21 Time 10:14 Rev Time 0.00
Received By rmcdouga Date 2022-06-14 Time 07:26 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-11-02 Cont ID  
Sent By aoliver Date 2022-11-02 Time 11:07 Rev Time 0.00
Received By aoliver Date 2022-10-25 Time 13:25 Sent To  
Notes
2022-11-02 11:07:10RECEIPT MU-2022-048588-0000 - $22.46 PAID
2022-10-25 13:26:0410/25/22 EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-07-20 Cont ID  
Sent By rmcdouga Date 2022-07-20 Time 07:43 Rev Time 0.00
Received By rmcdouga Date 2022-07-20 Time 07:43 Sent To  
Notes
2022-07-20 07:46:40PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-08-22 Cont ID  
Sent By medwards Date 2022-08-22 Time 15:54 Rev Time 0.00
Received By medwards Date 2022-08-22 Time 15:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-06-23 Cont ID  
Sent By medwards Date 2022-06-23 Time 14:59 Rev Time 0.00
Received By medwards Date 2022-06-23 Time 14:59 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status P Date 2022-11-18 Cont ID  
Sent By rmcdouga Date 2022-11-18 Time 13:41 Rev Time 0.00
Received By rmcdouga Date 2022-11-18 Time 13:41 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2022-10-18 Cont ID  
Sent By rmcdouga Date 2022-10-18 Time 14:12 Rev Time 0.00
Received By rmcdouga Date 2022-10-18 Time 11:08 Sent To  
Notes
2022-10-18 14:12:37PLEASE MAKE THE FOLLOWING CORRECTIONS TO THE
 PRE-CONSTRUCTION ELEVATION CERTIFICATE.
  
 MAIN HOUSE
 - ITEM A1 CORRECT THE OWNER'S NAME TO AQUANTIS GROUP
 LLC. [THE E.C. FOR THE MAIN HOUSE HAS AQUANTIS GROUP,
 INC.]
 - ITEM A7 SHOULD BE 1B. [ THIS IS RAISED SLAB ON STEM
 WALL CONSTRUCTION. ]
  
 CABANA
 - ITEM A7 SHOULD BE 1B. [ THIS IS RAISED SLAB ON STEM
 WALL CONSTRUCTION. ]

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2022-09-14 Cont ID  
Sent By rmcdouga Date 2022-09-14 Time 16:16 Rev Time 0.00
Received By rmcdouga Date 2022-09-08 Time 17:33 Sent To  
Notes
2022-09-08 17:46:21PLEASE MAKE THE FOLLOWING CORRECTIONS TO THE
 PRE-CONSTRUCTION ELEVATION CERTIFICATE.
 - ITEM A1 CORRECT THE OWNER'S NAME TO AQUANTIS GROUP
 LLC.
 - ITEM A3 CORRECT PALM BEACH COMPANY'S TO PALM BEACH
 COUNTY'S.
 - ITEM A7 SHOULD BE 1B.
 - ITEM A9 A) THE SQFT OF THE GARAGE IS SPECIFIED AS 488
 SQFT. THIS IS DIFFERENT FROM THE FLOOR PLAN A.1.1 (BLDG
 DATA= 552 SQFT) AND THE SITE PLAN A.0.1 ( FLOOD VENT
 CALCULATIONS= 546 SQFT). THE INSTRUCTIONS FOR
 COMPLETING THE ELEVATION CERTIFICATE FROM FEMA FOR ITEM
 A9 A) SAYS TO TAKE THE MEASUREMENTS FROM THE OUTSIDE OF
 THE GARAGE. PLEASE VERIFY THE SQUARE FEET OF THE
 GARAGE.
 - ITEM A9 B) SHOULD BE 4.
 -ITEM A9 C) SHOULD BE THE NET AREA OF THE SMART VENTS.
 THE 200 SQFT COVERAGE PER SQFT SHOULD BE EXPLAINED IN
 THE COMMENTS FOR SECTION D.
 - ITEM A9 D) SHOULD BE MARKED YES FOR ENGINEERED FLOOD
 OPENINGS.
 -ITEM B4 HAS THE WRONG MAP/PANEL NUMBER. IT SHOULD BE
 12099C 0583.
 - SECTION D COMMENTS SHOULD SPECIFY (4) SMART VENTS
 MODEL # 1540-520 WITH 200 SQFT OF COVERAGE FOR EACH FOR
 A TOTAL OF 800 SQFT.
 - REMOVE THE FLOOR PLAN FROM THE PHOTO SECTION.
 - A SEPARATE ELEVATION CERTIFICATE IS REQUIRED FOR THE
 POOL CABANA BECAUSE IT IS A SEPARATE STRUCTURE.

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-08-23 Cont ID  
Sent By ccole Date 2022-08-23 Time 15:28 Rev Time 0.00
Received By ccole Date 2022-08-23 Time 12:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-06-23 Cont ID  
Sent By ccole Date 2022-06-23 Time 16:42 Rev Time 0.00
Received By ccole Date 2022-06-23 Time 14:43 Sent To  
Notes
2022-06-23 16:43:211ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22060637
 6/23/22
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE NOTE THAT SEPARATE PERMITS ARE REQUIRED FOR
 THE POTABLE WATER BACKFLOW PREVENTER, THE IRRIGATION
 SYSTEM AND IRRIGATION BACKFLOW PREVENTER, THE SWIMMING
 POOL, AND THE CABANA- SECS. 105.1 & 107.2.1 WPB.
 2) SHEET P1.1: PLEASE SHOW KEYNOTE 3, 4, 6, 7, 8, 9, 10
 LOCATIONS ON THE PLAN- SEC. 107.2.1 WPB.
 3) P1.2: THE PLAN APPEARS TO SHOW A BATHTUB IN THE
 SHOWER SPACE IN HER BATHROOM. PROVIDE AN ENLARGED
 DETAIL SHOWING THE WIDTH AND DEPTH OF THE SHOWER PAN
 AND PAN INSTALLATION DETAILS- SECS. P2709.1 & P2709.2
 FBC RES.
 4) P1.1 & P3.1: INDICATE HOW DRAINAGE FROM THE ICE
 MAKERS WILL BE CONVEYED TO THE SANITARY SYSTEM- SEC.
 P2601.2 FBC RES.
 5) P3.1: PROVIDE THE TEXT NOTES FOR KEYNOTES 1-6, A & B
 SHOWN ON THE RISER- SEC. 107.2.1 WPB.
 6) FLOOD ZONE HAZARD: THE PROPERTY APPEARS TO BE IN AN
 AE FLOOD HAZARD ZONE. ACCORDING TO SECTION R322.1.6 FBC
 RES, PLUMBING FIXTURES, APPLIANCES, PIPING ETC. SHALL
 BE INSTALLED AT OR ABOVE THE ELEVATION REQUIRED IN
 SECTION R322.2 FBC RES. PLEASE PLACE NOTES AND DETAILS
 ON THE PLANS SHOWING COMPLIANCE WITH R322.1.7:
 PROTECTION OF WATER SUPPLY AND SANITARY SEWAGE SYSTEMS
 NEW WATER SUPPLY AND SANITARY PIPING SYSTEMS. NEW AND
 REPLACEMENT WATER SUPPLY SYSTEMS SHALL BE DESIGNED TO
 MINIMIZE OR ELIMINATE INFILTRATION OF FLOOD WATERS INTO
 THE SYSTEMS IN ACCORDANCE WITH THE PLUMBING PROVISIONS
 OF THIS CODE. NEW AND REPLACEMENT SANITARY SEWAGE
 SYSTEMS SHALL BE DESIGNED TO MINIMIZE OR ELIMINATE
 INFILTRATION OF FLOODWATERS INTO SYSTEMS AND DISCHARGES
 FROM SYSTEMS INTO FLOODWATERS IN ACCORDANCE WITH THE
 PLUMBING PROVISIONS OF THIS CODE AND IN ACCORDANCE WITH
 CHAPTER 64E-6, FLORIDA ADMINISTRATIVE CODE, STANDARDS
 FOR ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS. SEE
 ALSO SECTION 7.3 ASCE 24-14.
 6) C-1 SISTERN 1 & 2- SEC. 107.2.1 WPB: A) PROVIDE
 ENLARGED INSTALLATION DETAILS INCLUDING FLOOD WATER
 ANCHORING DETAILS. B) INDICATE THE CAPACITIES OF THE
 TANKS AND SIZING CALCULATIONS. C) SUBMIT MANUFACTURER'S
 SPECIFICATIONS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P-IRRIGATE IRRIGATION REVIEW
Rev No 1 Status N Date 2022-06-23 Cont ID  
Sent By ccole Date 2022-06-23 Time 16:44 Rev Time 0.00
Received By ccole Date 2022-06-23 Time 16:44 Sent To  
Notes
2022-06-23 16:45:58IRRIGATION WAS NOT REVIEWED UNDER THIS PERMIT. A
 SEPARATE PERMIT IS REQUIRED FOR IRRIGATION AND
 INSTALLATION OF THE RAIN CISTERNS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2022-09-08 Cont ID  
Sent By rmcdouga Date 2022-09-08 Time 08:43 Rev Time 0.00
Received By rmcdouga Date 2022-09-08 Time 08:43 Sent To  
Notes
2022-09-08 08:44:53PRODUCT APPROVALS FOR THE ROOFING MATERIALS ARE TO BE
 SUBMITTED UNDER A SEPARATE PERMIT PER SHEET A-0-0 OF
 THE PLANS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-07-20 Cont ID  
Sent By rmcdouga Date 2022-07-20 Time 07:47 Rev Time 0.00
Received By rmcdouga Date 2022-07-20 Time 07:46 Sent To  
Notes
2022-07-20 08:07:22NO PRODUCT APPROVALS WERE SUBMITTED FOR THE ROOFING
 MATERIALS. THE PRODUCT APPROVAL NOTES ON THE COVER
 SHEET, A-0.0, STATES THAT THE ROOFING WILL BE UNDER A
 SEPARATE PERMIT. THE PRODUCT APPROVALS FOR THE ROOF
 WILL BE REQUIRED TO BE SUBMITTED WITH THE ROOFING
 PERMIT.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-10-18 Cont ID  
Sent By rmcdouga Date 2022-10-18 Time 09:49 Rev Time 0.00
Received By rmcdouga Date 2022-10-18 Time 09:49 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-09-08 Cont ID  
Sent By rmcdouga Date 2022-09-08 Time 10:49 Rev Time 0.00
Received By rmcdouga Date 2022-09-08 Time 10:49 Sent To  
Notes
2022-08-23 15:31:17DIGITAL SEALS AND SIGS. ON PLUMBING PLANS APPROVED.
2022-08-22 15:56:38MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-07-21 Cont ID  
Sent By rmcdouga Date 2022-07-21 Time 06:51 Rev Time 0.00
Received By rmcdouga Date 2022-07-21 Time 06:51 Sent To  
Notes
2022-06-23 15:00:31MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop Z ZONING
Rev No 3 Status P Date 2022-10-20 Cont ID  
Sent By amhamilt Date 2022-10-20 Time 14:28 Rev Time 0.00
Received By amhamilt Date 2022-10-20 Time 14:28 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2022-08-25 Cont ID  
Sent By amhamilt Date 2022-08-25 Time 11:19 Rev Time 0.00
Received By amhamilt Date 2022-08-25 Time 11:18 Sent To  
Notes
2022-08-25 11:20:30THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 SITE PLAN DETAIL 5 SHOWS WALL AS 6' AND INDICATES IT
 WILL BE LOCATED ALONG PROPERTY LINE, HOWEVER, SITE PLAN
 SHOWS IT SET BACK FURTHER. PLEASE REVISE FOR CLARITY
 AND LOWER HEIGHT TO 4'
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop Z ZONING
Rev No 1 Status F Date 2022-07-13 Cont ID  
Sent By ahamilto Date 2022-07-13 Time 10:47 Rev Time 0.00
Received By amhamilt Date 2022-07-13 Time 10:47 Sent To  
Notes
2022-07-13 10:49:24THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PLEASE DIMENSION SETBACKS OF POOL CABANA BUILDING TO
 NORTH PROPERTY LINE.
  
 NEW CONSTRUCTION REQUIRES A SEPARATE LANDSCAPE PERMIT
 TO BE FILED BEFORE ZONING APPROVAL CAN MOVE FORWARD,
 PLEASE APPLY FOR A LANDSCAPE PERMIT (SEC 94-441 (B))
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  


Account Summary | Usage Policy | Privacy Policy