| Plan Review Stops For Permit 22060616 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2022-06-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-06-30 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-06-30 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2022-06-30 15:11:27 | FRONT BUILDING GIVEN THE NEW ADDRESS OF 505 KANUGA DR | | | AND THE REAR GARAGE APARTMENT GIVEN THE ADDRESS OF 507 | | | KANUGA DR, WORK TO BE DON ONE BOTH BUILDINGS. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2022-06-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-06-30 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-06-30 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2022-06-30 13:24:54 | PLANS APPEAR TO BE FOR BOTH BUILDINGS. UPSTAIRS GARAGE | | | APARTMENT NEEDS TO BE ASSIGNED AN ADDRESS, SHOULD HAVE | | | BEEN ASSIGNED A UNIQUE ADDRESS ORIGINALLY. PLEASE HAVE | | | THE OWNER CONTACT [email protected] OR CALL | | | 561-805-6659 TO READDRESS THE HALF ADDRESS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-09-06 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-09-06 |
Time |
11:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-09-02 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-09-02 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-08-29 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-08-29 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2022-08-30 16:46:07 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | REVIEW WILL BE PASSED AFTER UPLOAD FOR OTHER ADDRESS IS | | | COMPLETE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2022-07-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-23 |
Time |
19:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-23 |
Time |
19:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-08-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-30 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-30 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-07-15 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-07-15 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-22 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-22 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-07-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-07-01 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-07-01 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2022-07-01 09:18:58 | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 22060616 | | | 7/1/22 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. PLEASE NOTE THAT SEPARATE | | | PERMITS ARE REQUIRED FOR THE MAIN HOUSE AND GUEST | | | HOUSE. THE FOLLOWING REVIEW APPLIES TO BOTH | | | OCCUPANCIES. | | | | | | 1) SHEETS P-1 & P-3: PROVIDE EQUIPMENT SCHEDULES FOR | | | THE TANKLESS WATER HEATERS AND SUBMIT MANUFACTURER'S | | | SPECIFICATIONS AND INSTALLATION MANUALS- SEC.G2448.1 | | | FBC RES. | | | | | | 2) P-1 & P-3: PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW | | | RANGE AND SUBMIT MANUFACTURER'S SPECIFICATIONS- SECTION | | | G2447.1 FBC RES. A) PROVIDE COMBUSTION AIR CALCULATIONS | | | AND INDICATE HOW THE AIR WILL BE PROVIDED- SECTION | | | G2407.1 FBC RES. | | | | | | 3) P-1 & P-3: PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW | | | DRYER AND SUBMIT MANUFACTURER'S SPECIFICATIONS- SECTION | | | G2447.1 FBC RES. A) INDICATE HOW MAKEUP AIR WILL BE | | | PROVIDED IN ACCORDANCE WITH G2407.1 & G2439.5 FBC RES. | | | | | | 4) P-1 & P-3: THE PLANS SHOW AN EXISTING FIREPLACE. | | | VERIFY IT IS NOT A GAS FIREPLACE, OR SHOW THE GAS | | | PIPING ON THE RISER DRAWING- SEC. 107.2.1 WPB. | | | | | | 5) P-3: SHOW THE CUT PIPING LENGTHS AND TOTAL PIPING | | | RUN LENGTHS FROM THE LOW-PRESSURE REGULATORS TO THE | | | RANGE AND THE DRYER- SEC. G2413.4.1 FBC RES. | | | | | | 6) P3: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | REGULATORS MARKED UP TO SHOW THE SELECTED MODELS, AND | | | INPUT AND OUT PIPE SIZES AND PRESSURES- SECTION G2421.2 | | | FBC RES. | | | | | | 7) P-1 & P-3: PROVIDE CONDENSATE DISPOSAL PIPING | | | DETAILS FOR THE WATER HEATERS- SEC. 307.2 FBC FG. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-09-06 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-09-06 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-09-01 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-09-01 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-09-01 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2022-09-01 15:54:35 | PLANS FOR GUEST HOUSE NOT PROVIDED |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-07-29 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-07-29 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-07-29 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2022-07-29 11:55:12 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PER HISTORIC PRESERVATION DECISION LETTER, "THE | | | ACCESSORY STRUCTURE SHALL NOT HAVE AN OVEN OR RANGE AND | | | CANNOT BE CONSIDERED A FULLY SEPARATE UNIT DUE TO LOT | | | WIDTH AND OVERALL SF OF REAR BUILDING." PLEASE REVISE | | | PLANS TO REMOVE OVEN/RANGE. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-09-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-09-06 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-09-02 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-09-02 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-08-21 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-08-01 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-06-30 |
Time |
06:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2022-08-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-08-29 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-08-29 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-07-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-23 |
Time |
19:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-23 |
Time |
19:42 |
Sent To |
|
|
| Notes |
| 2022-07-23 19:42:46 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION WILL OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE EMAIL THE RECEIPT | | | TO [email protected]. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-22 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-22 |
Time |
14:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-01 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-01 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2022-07-01 12:20:08 | 1ST REVIEW FMC | | | PERMIT: 22060616 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 1 OF 13 OF THE ENERGY CALCULATIONS INDICATES 1 | | | STRUCTURE WITH 2482 SQ FT. THE DRAWINGS SUBMITTED | | | INDICATE A MAIN HOUSE AND A 2 STORY GARAGE WITH | | | STORAGE. THE GARAGE WITH STORAGE IS BEING CONVERTED SO | | | A SEPARATE PERMIT WILL BE REQUIRED FOR THIS CHANGE OF | | | USE. THE ENERGY CODE MUST REFLECT THE 2 SEPARATE | | | STRUCTURES. PROVIDE AN ENERGY CALCULATION FOR THE MAIN | | | HOUSE AND ONE FOR THE GUEST HOUSE SEPARATELY. FBC | | | 107.2.1 | | | | | | 2) THE MECHANICAL EQUIPMENT SIZING CALCULATIONS SHOULD | | | CLEARLY DISTINGUISH THE MAIN HOUSE FROM THE GUEST | | | HOUSE. SUBMIT A MECHANICAL CALCULATION FOR EACH. FBC | | | 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-22 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-22 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-07-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-07-01 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-07-01 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2022-07-01 08:17:36 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 22060616 | | | 7/1/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC EC- FLORIDA ENERGY EFFICIENCY DODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE ENERGY COMPLIANCE FORM R405-2020 DOES NOT | | | PROVIDE ANY DATA FOR THE HW PIPE INSULATION AND WATER | | | HEATER EFFICIENCY RATINGS- SECS. R403.5.3, R403.5.6.2 & | | | TABLES C403.2.10 & C404.2 FBC EC. | | | | | | 2) PLEASE NOTE SEPARATE PERMITS ARE REQUIRED FOR THE | | | MAIN HOUSE AND GUEST HOUSE. THE CURRENT REVIEW COMMENTS | | | APPLY TO BOTH OCCUPANCIES- SEC. 105.1 & 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-09-06 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-09-06 |
Time |
11:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-22 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-22 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2022-08-22 14:24:28 | SHEETS S2, S5 AND S6 ARE MISSING THE ARCHITECTURAL | | | DIGITAL SIGNATURE. SUBMIT DRAWINGS WITH THE DESIGNERS | | | DIGITAL SIGNATURES. FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-07-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-23 |
Time |
19:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-23 |
Time |
19:41 |
Sent To |
|
|
| Notes |
| 2022-07-15 12:12:54 | DIGITAL SIGNATURE FOR ELECTRIC IS APPROVED JLEAHY | | 2022-07-01 12:20:42 | DIGITAL SIGNATURES FOR MECHANICAL APPROVED ME | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-09-06 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-09-06 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-09-01 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2022-09-01 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2022-09-01 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2022-09-01 15:54:57 | NO GUEST HOUSE PLANS PROVIDED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-07-29 |
|
|
Cont ID |
|
| Sent By |
ahamilto |
Date |
2022-07-29 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-07-29 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2022-07-29 11:54:56 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PER HISTORIC PRESERVATION DECISION LETTER, "THE | | | ACCESSORY STRUCTURE SHALL NOT HAVE AN OVEN OR RANGE AND | | | CANNOT BE CONSIDERED A FULLY SEPARATE UNIT DUE TO LOT | | | WIDTH AND OVERALL SF OF REAR BUILDING." PLEASE REVISE | | | PLANS TO REMOVE OVEN/RANGE. | | | | | | ADDITIONALLY, THE VALUE OF CONSTRUCTION EXCEEDS 50% OF | | | THE IMPROVEMENT VALUE OF THE STRUCTURE AS DETERMINED BY | | | THE PBC PROPERTY APPRAISER, THEREFORE A SEPERATE | | | LANDSCAPE PERMIT IS REQUIRED AND MUST BE SUBMITTED FOR | | | ZONING APPROVAL TO MOVE FORWARD. PLEASE APPLY FOR A | | | SEPARATE LANDSCAPE PERMIT IN ORDER FOR ZONING APPROVAL | | | TO MOVE FORWARD. SEC 94-441 (B) | | | | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 |
|
|