| Plan Review Stops For Permit 22060591 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-08-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-08-03 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-08-03 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2022-08-03 12:05:57 | PROVISO - POOL EQUIPMENT TO MATCH HOUSE FINISHED FLOOR | | | ELEVATION | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-20 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-20 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2022-07-20 15:42:49 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FBC 107, PROVIDE THE SOILS REPORT. I WAS UNABLE TO | | | QUICKLY LOCATE IT IN THE BUILDING PERMIT FILE. | | | | | | 2. GENERAL NOTE #13 STATES THAT NO SOILS REPORT WAS | | | PROVIDED, PLEASE REMOVE, FBC107, SHEET 6. | | | | | | 3. REVISE GENERAL NOTE #10, REFERENCES ARE NOT | | | CONSISTENT WITH VERSION REQUIRED BY FBC R CHAPTER 46. | | | PLAN STATES 2013 VERSION, THIS IS NOT THE CORRECT | | | VERSION FOR THREE OF THE REFERENCES. | | | | | | 4. SHEET 6 STATES THAT EQUIPMENT WILL BE ANCHORED PER | | | NOA. TO MY KNOWLEDGE THERE IS NO NOA FOR THE POOL | | | EQUIPMENT. EITHER PROVIDE A STRUCTURAL DETAIL FOR | | | ANCHORING OR PROVIDE THE NOA REFERENCED, FBC R 301. | | | | | | 5. THIS PERMIT WILL BE ISSUED WITH PROVISO, POOL | | | EQUIPMENT TO MATCH HOUSE FINISHED FLOOR. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-08-22 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-08-19 |
Time |
09:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-08-08 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-08-08 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-08-08 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2022-08-08 09:08:45 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-07-11 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-07-11 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2022-07-11 09:42:16 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-27 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-27 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2022-06-27 16:46:34 | THE GAS POOL HEATER AND GAS PIPING SHALL BE INSTALLED | | | UNDER A SEPARATE PERMIT. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-07-05 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-07-05 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-07-05 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
P |
Date |
2022-08-22 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-08-22 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-08-12 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-08-08 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-08-08 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-07-29 |
Time |
06:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-20 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-06-21 |
Time |
09:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-01 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-01 |
Time |
07:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-27 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-27 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-08-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-08-03 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-08-03 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2022-08-03 12:04:51 | ORIGINAL SOILS ENGINEERING WITH HOUSE PERMIT | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-07-11 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-07-11 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-06-24 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-06-24 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|