Plan Review Details - Permit 22060380
Plan Review Stops For Permit 22060380
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2022-07-27 Cont ID  
Sent By shill Date 2022-07-27 Time 12:23 Rev Time 0.00
Received By shill Date 2022-07-27 Time 12:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-08-10 Cont ID  
Sent By rmcdouga Date 2022-08-10 Time 13:34 Rev Time 0.00
Received By rmcdouga Date 2022-08-10 Time 13:34 Sent To  
Notes
2022-08-10 13:35:38REMODEL BATHROOMS. SCOPE OF WORK PER CONTRACT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-08-01 Cont ID  
Sent By shill Date 2022-08-01 Time 13:50 Rev Time 0.00
Received By shill Date 2022-08-01 Time 13:50 Sent To  
Notes
2022-08-01 13:53:46****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 FROM PREVIOUS LIST:
  
 1. FBC 107 PROVIDE A PLAN SHOWING THE AREA OF WORK. THE
 AREA TO BE RETILED SHOULD BE CLEARLY MARKED WITH A NOTE
 DESCRIBING WORK. IT APPEARS THAT ONLY FLOOR TILE IS
 PROPOSED, IS THAT CORRECT? PLAN SHOULD BE CLEAR AS TO
 SCOPE.
  
 2ND REVIEW :
  
 THE CONTRACT WAS UPLOADED AND SHOWS MORE WORK THAN
 DESCRIBED IN THE APPLICATION. SCOPE WHICH APPEARS TO BE
 INCLUDED:
  
 REMOVE LIGHT
 REROUTE PLUMBING TO OPPOSING WALL, NEW VALVE, REBUILD
 SHOWER PAN, WIDEN SHOWER
 INSTALL NEW SINK, VALVE, ETC
 INSTALL SHOWER BENCH
 MARBLE ON FLOOR AND WALLS
 OTHER WORK
  
 FBC 107, PROVIDE AN ARCHITECTURAL QUALITY PLAN, TO
 SCALE, WHICH SHOWS ALL PROPOSED IMPROVEMENTS. SUBMIT A
 NEW APPLICATION WHICH REFLECTS SCOPE (CURRENTLY STATES
 "REPLACE BATHROOM TILE).
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-07-27 Cont ID  
Sent By shill Date 2022-07-27 Time 12:23 Rev Time 0.00
Received By shill Date 2022-07-27 Time 12:23 Sent To  
Notes
2022-07-27 12:25:24****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. FBC 107 PROVIDE A PLAN SHOWING THE AREA OF WORK. THE
 AREA TO BE RETILED SHOULD BE CLEARLY MARKED WITH A NOTE
 DESCRIBING WORK. IT APPEARS THAT ONLY FLOOR TILE IS
 PROPOSED, IS THAT CORRECT? PLAN SHOULD BE CLEAR AS TO
 SCOPE.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2022-08-05 Cont ID  
Sent By jleahy Date 2022-08-05 Time 15:44 Rev Time 0.00
Received By jleahy Date 2022-08-05 Time 15:43 Sent To  
Notes
2022-08-05 15:44:58NO ELECTRICAL WORK SHOWN OR APPROVED JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-07-14 Cont ID  
Sent By cwalker Date 2022-07-14 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-08-10 Cont ID  
Sent By rmcdouga Date 2022-08-10 Time 13:36 Rev Time 0.00
Received By rmcdouga Date 2022-08-08 Time 16:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-08-05 Cont ID  
Sent By jleahy Date 2022-08-05 Time 15:47 Rev Time 0.00
Received By jleahy Date 2022-07-28 Time 07:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-27 Cont ID  
Sent By shill Date 2022-07-27 Time 12:25 Rev Time 0.00
Received By shill Date 2022-07-11 Time 06:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-08-10 Cont ID  
Sent By rmcdouga Date 2022-08-10 Time 13:35 Rev Time 0.00
Received By rmcdouga Date 2022-08-10 Time 13:35 Sent To  
Notes
2022-08-10 13:36:48SCOPE OF WORK PER CONTRACT. PLUMBING SUB-PERMIT IS
 REQUIRED.

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-08-04 Cont ID  
Sent By ccole Date 2022-08-04 Time 10:28 Rev Time 0.00
Received By ccole Date 2022-08-04 Time 10:24 Sent To  
Notes
2022-08-04 10:38:391ST REVIEW FBC-2020 PLUMBING
 PERMIT-22060380
 8/4/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE A DIMENSIONED PLUMBING FLOOR PLAN DRAWING
 WITH NOTES INDICATING THE SCOPE OF PLUMBING WORK FOR
 THE REMODELED BATHROOM- SECS. 107.2.1 & 107.3.5.1.3
 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-07-27 Cont ID  
Sent By shill Date 2022-07-27 Time 12:25 Rev Time 0.00
Received By shill Date 2022-07-27 Time 12:25 Sent To  
Notes
***NONE***