| Plan Review Stops For Permit 22060290 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-06-07 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-06-07 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-06-07 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2022-06-07 11:36:08 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-06-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-06-01 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-06-01 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2023-06-01 17:51:20 | NEW SINGLE FAMILY RESIDENCE(R3) FOURTH BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22060290 | | | 1001 WINDSOR AVE | | | | | | PROVISO NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO ONCE | | | CLEAR/LEGIBLE PLANS ARE UPLOADED TO PROJECTDOX. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES APPLY (EXCEPT FOR | | | PRODUCT APPROVALS DEFERRED SUBMITTAL). | | | | | | ***IMPORTANT | | | ****CONTRACTOR TO ADVICE IF PROVISO OPTION IS PREFERRED | | | AT THIS TIME OR IF RE-SUBMITTING REQUIRED INFORMATION | | | BEFORE PERMIT ISSUANCE. | | | | | | | | | 7- NEW ENERGY CALCULATIONS SUBMITTED: | | | A)FORM 401-10 WAS SUBMITTED. NEED TO SUBMIT CURRENT | | | 405-2020 FORM. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | B)ITEM #5 ON PAGE 1 SPECIFIES WORST CASE SCENARIO. | | | ENERGY CALCULATIONS NEED TO BE SITE SPECIFIC AS | | | REQUIRED BY SEC. R405.4.2.1 (4) FBC- ENERGY | | | CONSERVATION. | | | REVISE AS REQUIRED. | | | | | | C)CONCRETE BLOCK INSULATION R-VALUE DOESN???T MATCH | | | R-VALUE SPECIFIED ON TYPICAL WALL SECTION. REVISE AS | | | REQUIRED TO MATCH. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | D)REVISE SPACE INFORMATION ON PAGE 2. NUMBER OF | | | OCCUPANTS CAN NOT BE 3.5. NEED TO ROUND UP THE NUMBER. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | E)REVISE DOOR ORIENTIN ON PAGE 3. ENTRY DOO IS ON THE | | | EAST SIDE. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | F)REVISE WINDOWS INFORMATION TO MATCH PLANS. REVISE | | | WINDOWS ORIENTATION, WINDOWS FRAME TYPE (ALUMINUM, NOT | | | VINYL), WINDOWS AREA AND WINDOWS OVERHANG DEPTH AND | | | SEPARATION TO MATCH PLANS. ALSO, THERE IS NOT GLASS | | | BLOCK ON PLANS. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | | | | | | 8- ALL RESUBMITTED PLANS ARE NOT LEGIBLE. NEED TO | | | UPLOAD CLEAR AND LEGIBLE DRAWINGS. SEC. 107.2.1 CITY | | | AMENDMENTS. SEC. 107.2.1.3 CITY AMENDMENTS. | | | | | | RESPONSE: | | | PLANS ARE STILL NOT LEGIBLE. | | | | | | 9- ENGINEER TO REVISE SITE DRAINAGE PLAN ON SHEET 8. | | | THE PROPOSED GRADE AT THE SWALE AREA IS HIGHER THAN THE | | | ADJACENT GRADE. ALSO, IT DOESN'T MATCH SECTION DETAILS | | | A-A, B-B AND C-C. | | | ACCORDING TO SECTION DETAILS A-A, B-B AND C-C THE GRADE | | | IS HIGHER AT THE PERIMETER OF THE LOT. ENGINEER OF | | | RECORD TO PROVIDE DETAILS AND SPECIFICATIONS SHOWING | | | HOW THE RAISED GRADE IS SUPPORTED. IF RETAINING WALLS | | | ARE REQUIRED, THEN SEPARATE PERMIT IS REQUIRED. SEC. | | | 105.1 CITY AMENDMENTS, SEC. 105.2.5 CITY AMENDMENTS. | | | SEC. R401.3 FC-RESIDENTIAL. | | | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED | | | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | RESPONSE: | | | UNABLE TO READ THE PLANS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-03-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-03 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-03 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2023-03-03 17:37:27 | NEW SINGLE FAMILY RESIDENCE (R3) THIRD BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22060290 | | | 1001 WINDSOR AVE | | | | | | 7- ENERGY CALCULATIONS SUBMITTED: | | | PREVIOUS COMMENT: | | | A) NEED TO COMPLETE THE "INSTALLED" INFORMATION ON PAGE | | | 1 AS REQUIRED BY THE GENERAL INSTRUCTIONS ON SAME | | | SHEET. SEC. R101.5.1.1.1 FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | NOTE: IF ALL OF THE VALUES LISTED UNDER CLIMATE ZONE 1 | | | ARE NOT INSTALLED, THEN THIS PRESCRIPTIVE FORM CANNOT | | | BE USED. SEE SCOPE INFORMATION ON TOP OF GENERAL | | | INSTRUCTIONS OF FORM 402-2020 SUBMITTED. | | | | | | PREVIOUS COMMENT: | | | B)NEED TO COMPLETE THE "INSTALLED EFFICIENCY LEVEL" | | | INFORMATION ON PAGE 2 AS REQUIRED BY THE NOTE ON TOP OF | | | SAME SHEET. SPECIFY THE DUCT R-VALUE. SEC. R101.5.1.1.1 | | | FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | R-VALUE SPECIFIED IS INCORRECT. DUCTS R-VALUE IN | | | UNCONDITIONED ATTICS IS R-8 NOT R-6. | | | ALSO, SPECIFY LOCATION OF AIR HANDLER. | | | | | | PREVIOUS COMMENT: | | | 8- ALL RESUBMITTED PLANS ARE NOT LEGIBLE. NEED TO | | | UPLOAD CLEAR AND LEGIBLE DRAWINGS. SEC. 107.2.1 CITY | | | AMENDMENTS. SEC. 107.2.1.3 CITY AMENDMENTS. | | | | | | RESPONSE: | | | PLANS NEED TO BE CLEAR TO BE REVIEWED AND STAMPED. | | | THOSE WILL BE THE OFFICIAL APPROVED PLANS. IF THE | | | ORIGINALS RE NOT CLEAR, THEN THE PLANS WILL NOT BE | | | LEGIBLE WHEN PRINTING FOR THE JOB SITE EITHER. | | | MECHANICAL REVIEWER HAS COMMENTS REGARDING THIS ISSUE | | | ALSO. | | | WE NEED LEGIBLE COPIES FOR RECORDS MANAGEMENT. SEC. | | | 107.2.1.3 CITY AMENDMENTS. | | | | | | PREVIOUS COMMENT: | | | 9- ENGINEER TO REVISE SITE DRAINAGE PLAN ON SHEET 8. | | | THE PROPOSED GRADE AT THE SWALE AREA IS HIGHER THAN THE | | | ADJACENT GRADE. ALSO, IT DOESN'T MATCH SECTION DETAILS | | | A-A, B-B AND C-C. | | | ACCORDING TO SECTION DETAILS A-A, B-B AND C-C THE GRADE | | | IS HIGHER AT THE PERIMETER OF THE LOT. ENGINEER OF | | | RECORD TO PROVIDE DETAILS AND SPECIFICATIONS SHOWING | | | HOW THE RAISED GRADE IS SUPPORTED. IF RETAINING WALLS | | | ARE REQUIRED, THEN SEPARATE PERMIT IS REQUIRED. SEC. | | | 105.1 CITY AMENDMENTS, SEC. 105.2.5 CITY AMENDMENTS. | | | SEC. R401.3 FC-RESIDENTIAL. | | | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED | | | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | RESPONSE: | | | DRAINAGE PLAN IS NOT LEGIBLE. UNABLE TO REVIEW. | | | ALSO, ENGINEER DOESN'T SHOW HOW RAISING THE GRADE AT | | | THE PERIMETER OF THE LOT. RETAINING WALL REQUIRED? | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-01-25 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-02-23 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2023-01-25 14:23:42 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22060290 1001 WINDSOR AVE | | | | | | ARCHITECTS-ENGINEERS | | | FLORIDA STATUTE 553.80(2)(B): | | | ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN | | | PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT | | | NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | | REVIEW | | | | | | | | | ORIGINAL COMMENT: | | | 1- BEDROOM #3 AND BEDROOM #4. THE SPECIFIED WINDOW SIZE | | | DOESN'T SEEM TO COMPLY WITH EGRESS REQUIREMENTS OF SEC. | | | R310.2.1 FBC-RESIDENTIAL. TYPICALLY, 50-3/8" SINGLE | | | HUNG WINDOW DOESN'T PROVIDE THE REQUIRED 24" CLEAR | | | HEIGHT. REVISE SIZE OR PROVIDE MANUFACTURER'S | | | SPECIFICATIONS SHOWING COMPLIANCE WITH ALL THE EGRESS | | | CLEAR OPENINGS. | | | | | | RESPONSE: | | | WINDOW SIZE WAS NOT REVISED. NEED TO REVISE. TYPICALLY, | | | 37" X 63" WINDOWS AS SPECIFIED FOR BEDROOM #2 ARE THE | | | ONES COMPLYING WITH THE EGRESS REQUIREMENTS. REVISE AS | | | REQUIRED. | | | | | | ORIGINAL COMMENT: | | | 2- REVISE ROOF SHEATHING NAILING SPECIFICATIONS TO | | | COMPLY WITH NEW 2020 FBC-RESIDENTIAL NAILING SPACING | | | SPECIFICATIONS. ROOF SHEATHING NEEDS TO BE NAILED AT 4 | | | INCHES O.C. IN THE FIELD AND EDGES AS REQUIRED BY SEC. | | | R803.2.3.1 AND TABLE R803.2.3.1 FBC-RESIDENTIAL. | | | NOTE: REVISE SPECIFICATIONS OR PROVIDE CALCULATIONS | | | SHOWING THAT SPECIFIED NAIL TYPE AND SPACING MATCHES OR | | | EXCEEDS TABLE R803.2.3.1 FBC-RESIDENTIAL MINIMUM | | | REQUIREMENTS. | | | REVISE NOTE "C" ON PLYWOOD ROOF SHEATHING NOTES AND | | | NOTE #9 ON ROOF PLAN NOTES ON SHEET GN. TYPICAL WALL | | | SECTION ON SHEET 4. | | | | | | RESPONSE: | | | ROOF SHEATHING SPECIFICATIONS ON TYPICAL WALL SECTION | | | ON SHEET 4 WAS NOT REVISED TO SHOW COMPLIANCE. NEED TO | | | REVISE AS REQUIRED. | | | | | | ORIGINAL COMMENT: | | | 3- ATTIC VENTILATION SPECIFIED ON ATTIC VENTILATION | | | CALCULATION ON SHEET 1 AND VENTED ALUMINUM SOFFIT | | | SPECIFICATION SHOWN ON THE TYPICAL WALL SECTION ON | | | SHEET 4 DON'T MATCH. REVISE AS REQUIRED TO MATCH. SEC. | | | R806 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | 4- OK. | | | 5- OK. | | | 6- OK. | | | | | | 7- ENERGY CALCULATIONS SUBMITTED: | | | ORIGINAL COMMENT: | | | A) NEED TO COMPLETE THE "INSTALLED" INFORMATION ON PAGE | | | 1 AS REQUIRED BY THE GENERAL INSTRUCTIONS ON SAME | | | SHEET. SEC. R101.5.1.1.1 FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | ORIGINAL COMMENT: | | | B)NEED TO COMPLETE THE "INSTALLED EFFICIENCY LEVEL" | | | INFORMATION ON PAGE 2 AS REQUIRED BY THE NOTE ON TOP OF | | | SAME SHEET. SPECIFY THE DUCT R-VALUE. SEC. R101.5.1.1.1 | | | FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | R-VALUE SPECIFIED IS INCORRECT. DUCTS DIAMETER IS | | | GREATER THAN 3 IN. | | | ALSO, SPECIFY LOCATION OF AIR HANDLER. | | | | | | C)OK. | | | D)OK. | | | E)OK. | | | | | | NEW COMMENT BASED ON INFORMATION SUBMITTED: | | | 8- ALL RESUBMITTED PLANS ARE NOT LEGIBLE. NEED TO | | | UPLOAD CLEAR AND LEGIBLE DRAWINGS. SEC. 107.2.1 CITY | | | AMENDMENTS. SEC. 107.2.1.3 CITY AMENDMENTS. | | | | | | 9- ENGINEER TO REVISE SITE DRAINAGE PLAN ON SHEET 8. | | | THE PROPOSED GRADE AT THE SWALE AREA IS HIGHER THAN THE | | | ADJACENT GRADE. ALSO, IT DOESN'T MATCH SECTION DETAILS | | | A-A, B-B AND C-C. | | | ACCORDING TO SECTION DETAILS A-A, B-B AND C-C THE GRADE | | | IS HIGHER AT THE PERIMETER OF THE LOT. ENGINEER OF | | | RECORD TO PROVIDE DETAILS AND SPECIFICATIONS SHOWING | | | HOW THE RAISED GRADE IS SUPPORTED. IF RETAINING WALLS | | | ARE REQUIRED, THEN SEPARATE PERMIT IS REQUIRED. SEC. | | | 105.1 CITY AMENDMENTS, SEC. 105.2.5 CITY AMENDMENTS. | | | SEC. R401.3 FC-RESIDENTIAL. | | | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED | | | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM | | | ADJACENT PROPERTIES. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-08-01 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-07-29 |
Time |
18:22 |
Sent To |
|
|
| Notes |
| 2022-08-01 10:18:17 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22060290 1001 WINDSOR AVE | | | | | | 1- BEDROOM #3 AND BEDROOM #4. THE SPECIFIED WINDOW SIZE | | | DOESN'T SEEM TO COMPLY WITH EGRESS REQUIREMENTS OF SEC. | | | R310.2.1 FBC-RESIDENTIAL. TYPICALLY, 50-3/8" SINGLE | | | HUNG WINDOW DOESN'T PROVIDE THE REQUIRED 24" CLEAR | | | HEIGHT. REVISE SIZE OR PROVIDE MANUFACTURER'S | | | SPECIFICATIONS SHOWING COMPLIANCE WITH ALL THE EGRESS | | | CLEAR OPENINGS. | | | | | | 2- REVISE ROOF SHEATHING NAILING SPECIFICATIONS TO | | | COMPLY WITH NEW 2020 FBC-RESIDENTIAL NAILING SPACING | | | SPECIFICATIONS. ROOF SHEATHING NEEDS TO BE NAILED AT 4 | | | INCHES O.C. IN THE FIELD AND EDGES AS REQUIRED BY SEC. | | | R803.2.3.1 AND TABLE R803.2.3.1 FBC-RESIDENTIAL. | | | NOTE: REVISE SPECIFICATIONS OR PROVIDE CALCULATIONS | | | SHOWING THAT SPECIFIED NAIL TYPE AND SPACING MATCHES OR | | | EXCEEDS TABLE R803.2.3.1 FBC-RESIDENTIAL MINIMUM | | | REQUIREMENTS. | | | REVISE NOTE "C" ON PLYWOOD ROOF SHEATHING NOTES AND | | | NOTE #9 ON ROOF PLAN NOTES ON SHEET GN. TYPICAL WALL | | | SECTION ON SHEET 4. | | | | | | 3- ATTIC VENTILATION SPECIFIED ON ATTIC VENTILATION | | | CALCULATION ON SHEET 1 AND VENTED ALUMINUM SOFFIT | | | SPECIFICATION SHOWN ON THE TYPICAL WALL SECTION ON | | | SHEET 4 DON'T MATCH. REVISE AS REQUIRED TO MATCH. SEC. | | | R806 FBC-RESIDENTIAL. | | | | | | 4- NORTH ARROW ORIENTATION SHOWN ON ALL PLANS SUBMITTED | | | IS INCORRECT. SEE SURVEY AND REVISE AS REQUIRED. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | 5- PRODUCT APPROVALS | | | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 | | | FOR: | | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | | | A)VENTED ALUMINUM SOFFIT SPECIFIED ON THE TYPICAL WALL | | | SECTION. | | | | | | 6- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | | | 7- ENERGY CALCULATIONS SUBMITTED: | | | A) NEED TO COMPLETE THE "INSTALLED" INFORMATION ON PAGE | | | 1 AS REQUIRED BY THE GENERAL INSTRUCTIONS ON SAME | | | SHEET. SEC. R101.5.1.1.1 FBC-ENERGY CONSERVATION. | | | | | | B)NEED TO COMPLETE THE "INSTALLED EFFICIENCY LEVEL" | | | INFORMATION ON PAGE 2 AS REQUIRED BY THE NOTE ON TOP OF | | | SAME SHEET. SPECIFY THE DUCT R-VALUE. SEC. R101.5.1.1.1 | | | FBC-ENERGY CONSERVATION. | | | | | | C)DUCT TESTING IS REQUIRED. REVISE INFORMATION ON PAGE | | | 2. SEC. R101.5.1.1.1 FBC-ENERGY CONSERVATION. | | | | | | D)THERE IS NOT PTAC INSTALLED IN THIS HOUSE. REVISE | | | INFORMATION SHOWN ON PAGE 2. SEC. R101.5.1.1.1 | | | FBC-ENERGY CONSERVATION. | | | | | | E)WATER HEATER INFORMATION ON PAGE 2 DOESN'T MATCH | | | PLANS. SEC. R101.5.1.1.1 FBC-ENERGY CONSERVATION. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-03-09 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2023-03-09 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2023-03-07 |
Time |
22:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-01-12 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2023-01-12 |
Time |
21:09 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2023-01-12 |
Time |
21:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-06-24 |
Time |
23:25 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-06-24 |
Time |
19:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-06-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-06-01 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-02 |
Time |
18:56 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-03-09 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2023-03-09 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2023-02-22 |
Time |
07:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-01-25 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-01-05 |
Time |
08:07 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-08-01 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-06-07 |
Time |
10:14 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-01-25 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-01-25 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2023-01-25 14:24:35 | NOTE: IMPACT FEES QUESTIONNAIRE IS ALREADY UPLOADED TO | | | PROJECTDOX. THE PERMIT LIBRARIAN WILL EMAIL THE COUNTY | | | WHEN THE PERMIT IS CLOSE TO BE APPROVED. JG. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-07-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-07-29 |
Time |
18:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-07-29 |
Time |
18:23 |
Sent To |
|
|
| Notes |
| 2022-07-29 18:27:23 | NOTE: IMPACT FEES QUESTIONNAIRE IS ALREADY UPLOADED TO | | | PROJECTDOX. THE PERMIT LIBRARIAN WILL EMAIL THE COUNTY | | | WHEN THE PERMIT IS CLOSE TO BE APPROVED. JG. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2023-05-09 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-09 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-09 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2023-05-09 07:40:05 | THE MECHANICAL DRAWING IS A COPY OF THE ORIGINAL. IT | | | CANNOT BE READ. PROVIDE A CLEAR DRAWING THAT CAN BE | | | READ. FBC 107.3.5 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-27 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-27 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2023-02-27 10:38:08 | PLEASE UNDERSTAND THAT I CANNOT SEE THE INFORMATION ON | | | THIS MECHANICAL DRAWING. | | | | | | THE DRAWING SUBMITTED IS NOT READABLE. PROVIDE THE | | | ORIGINAL SIGNED AND SEALED MECHANICAL DRAWING. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-06 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-06 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2023-01-06 16:34:17 | THE DRAWING SUBMITTED IS NOT READABLE. PROVIDE THE | | | ORIGINAL SIGNED AND SEALED MECHANICAL DRAWING. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-06-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-06-17 |
Time |
05:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-06-17 |
Time |
05:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2023-05-03 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-03 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-03 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2023-05-03 13:48:12 | 1ST PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMEND 107.3.5.3 (12) - FOR SOME REASON THE | | | PLUMBING DIAGRAMS PREVIOUSLY APPROVED ARE CROSSED OUT. | | | PLEASE RECTIFY. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-06 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-06-08 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-06-08 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-06-08 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-01-25 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-01-25 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2023-01-25 14:32:22 | 1-SHINGLES GFA NOA 21-1209.01 | | | 2-ROOF UNDERLAYMENT POLYGLASS POLYSTICK NOA 21-1217.02 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-08-01 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-08-01 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2022-08-01 10:43:28 | 1-SHINGLES NOA 21-1209.01 | | | 2-ROOF UNDERLAYMENT NOA 21-0602.14 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-05-02 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-05-02 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2023-05-02 12:19:24 | SIGNATURE REVIEW FBC- 2020 | | | PERMIT- 22060290 | | | 5/2/23 | | | | | | CODES IN EFFECT: | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE SUBMITTED PLAN SHEETS GN, 1, 4, & 8 APPEAR TO BE | | | PRINTED COPIES OF DIGITALLY SIGNED AND SEALED PLANS. | | | PLANS PREPARED BY FL. LICENSED ENGINEERS THAT ARE | | | TRANSMITTED ELECTRONICALLY SHALL BEAR VERIFIABLE | | | DIGITAL SEALS AND SIGNATURES OF THE ENGINEERS- FL. | | | STATUTE 471.025, AND SECTION 61G15-23.005 FAC. PLANS | | | SUBMITTED IN PAPER FORM TO THE FRONT COUNTER OF THE WPB | | | BUILDING DEPT. SHALL BEAR EITHER RAISED OR INK SEALS | | | AND THE WET SIGNATURES OF THE ENGINEER OF RECORD. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-03-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-03 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-03 |
Time |
17:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-01-25 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-01-25 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-08-01 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-08-01 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2022-08-01 10:48:29 | SIGNATURE REVIEW | | | | | | 1- ALL DRAWINGS NEED THE ORIGINAL SEAL AND SIGNATURE OF | | | THE ENGINEER AS REQUIRED BY CHAPTER 471 FLORIDA | | | STATUTES WHEN SUBMITTING DOCUMENTS/PLANS FOR PUBLIC | | | RECORDS. | | | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH ENGINEER'S | | | VERIFIABLE DIGITAL SIGNATURE | | | | | | ENGINEERS | | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2023-05-16 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-05-16 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-05-16 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-03-06 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-03-06 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-01-18 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-01-18 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-01-18 |
Time |
12:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |