Plan Review Details - Permit 22060203
| Plan Review Stops For Permit 22060203 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-26 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-26 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-06-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-06-30 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-06-30 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2022-06-30 09:24:43 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | GROUNDING ELECTRODE SYSTEM TO BE INSTALLED PER | | | 250.32(A) AT EACH BUILDING. | | | | | | 250.32 BUILDINGS OR STRUCTURES SUPPLIED BY A FEEDER(S) | | | OR BRANCH CIRCUIT(S). | | | (A) GROUNDING ELECTRODE. BUILDING(S) OR STRUCTURE(S) | | | SUPPLIED BY FEEDER(S) OR BRANCH CIRCUIT(S) SHALL HAVE A | | | GROUNDING | | | ELECTRODE OR GROUNDING ELECTRODE SYSTEM INSTALLED IN | | | ACCORDANCE WITH PART III OF ARTICLE 250. THE GROUNDING | | | ELECTRODE | | | CONDUCTOR(S) SHALL BE CONNECTED IN ACCORDANCE WITH | | | 250.32(B) OR (C). WHERE THERE IS NO EXISTING GROUNDING | | | ELECTRODE, | | | THE GROUNDING ELECTRODE(S) REQUIRED IN 250.50 SHALL BE | | | INSTALLED. | | | | | | HAND DRYERS TO BE GFCI PROTECTED PER 210.8(B) WITHIN 6' | | | OF A SINK. | | | | | | RECEPTACLE. A CONTACT DEVICE INSTALLED AT THE OUTLET | | | FOR THE CONNECTION OF AN ATTACHMENT PLUG, OR FOR THE | | | DIRECT CONNECTION | | | OF ELECTRICAL UTILIZATION EQUIPMENT DESIGNED TO MATE | | | WITH THE CORRESPONDING CONTACT DEVICE. A SINGLE | | | RECEPTACLE IS A SINGLE | | | CONTACT DEVICE WITH NO OTHER CONTACT DEVICE ON THE SAME | | | YOKE A MULTIPLE RECEPTACLE IS TWO OR MORE CONTACT | | | DEVICES ON THE | | | SAME YOKE. (CMP-18) | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-26 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-04 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-06-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-06-30 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-06-07 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
REV |
REVISIONS |
| Rev No |
1 |
Status |
P |
Date |
2022-06-07 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-06-07 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-06-07 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2022-06-07 13:10:02 | OK TO PASS STOP ONCE FEES HAVE BEEN PAID TO ISSUE. LEM |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-26 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-06-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-06-30 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-06-30 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2022-06-30 09:41:40 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGES SEEM TO BE COPIES OF THE ORIGINALS. | | | | | | | | | PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON | | | RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A | | | DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY | | | VERIFICATION. SELF-CERTIFICATION IS NOT ACCEPTABLE. WPB | | | FBC 107.1; FS 471/481 | | | | | | |
|
|
|