| Plan Review Stops For Permit 22051470 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-09-06 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-09-06 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2022-09-06 10:45:18 | X ZONE | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-08-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-08-15 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-08-15 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-23 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-23 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2022-07-23 11:18:16 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. ES8000 AND MULLION PRODUCT APPROVAL - UPLOAD AS ONE | | | PDF THE COVER SHEET, EVALUATION REPORT, AND | | | INSTALLATION INSTRUCTIONS. THE COVER PAGE SHOWS THE | | | STATUS, CODE VERSION, PRODUCT APPROVAL NUMBER. FBC R | | | 301. | | | | | | THIS SHOULD BE REVIEWED BY DESIGNER OF RECORD PRIOR TO | | | UPLOADING, FS107. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-09-15 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-09-15 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-09-15 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-08-16 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-16 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-16 |
Time |
13:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-07-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-07-01 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-07-01 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-09-22 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-09-22 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-09-07 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-09-07 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2022-09-07 12:01:51 | 3RD REVIEW FBC-2020 RES. GAS | | | PERMIT- 22051470 | | | 9/7/22 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. COMMENTS BELOW ARE BASED | | | ON REVISED PLAN SHEETS P-1 & P-2. | | | | | | 1) THE RISER SHOWS AN EXISTING 18 FT. SECTION OF ?-INCH | | | PE PIPE FROM THE METER TO THE FIRST TEE WHICH MUST BE | | | INCREASED IN SIZE TO 1-INCH BASED ON TABLE 402.4(22) | | | FBC FG. THE ?-INCH CAN SUPPLY A MAXIMUM 949,000 BTUS AT | | | 125FT. TOTAL DEVELOPED LENGTH. THE TOTAL LOAD OF SYSTEM | | | SHOWN IN THE RISER IS 1,348,000 BTUS. PLEASE NOTE THE | | | RISER APPROVED UNDER PREVIOUS PERMIT 17110370 SHOWS TWO | | | TEES OFF THE MAIN SUPPLY PIPE AT THE METER- ONE TEE FOR | | | THE UNDERGROUND PE, AND ONE FOR THE INTERIOR SCHEDULE | | | 40 METALLIC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | CCOLE@WPB. | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-08-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-12 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-12 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2022-08-12 16:20:32 | 2ND REVIEW FBC-2020 RES. GAS | | | PERMIT- 22051470 | | | 8/12/22 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. COMMENTS BELOW ARE BASED | | | ON REVISED PLAN SHEETS P-1 & P-2. | | | | | | 1) THE NEW RISER SPECIFYING SCHEDULE 40 METALLIC GAS | | | PIPING THROUGHOUT THE ENTIRE SYSTEM, INCLUDING | | | UNDERGROUND, DOES NOT MATCH THE PREVIOUS RISER DRAWING | | | APPROVED UNDER PERMIT 17110370 FOR THE 48KW GENERATOR | | | WHICH SHOWS PE UNDERGROUND OUTSIDE OF THE HOUSE AND | | | CSST INSIDE THE RESIDENCE SUPPLYING THE DRYERS AND TWO | | | OF THE TANKLESS WATER HEATERS- SEC. 107.2.1 WPB. PLEASE | | | NOTE THAT STEEL PIPING MAY ONLY BE RUN UNDERGROUND IF | | | PROPERLY PROTECTED FROM CORROSION IN ACCORDANCE WITH | | | SEC. G2415.11.2 FBC RES: | | | G2415.11.2 PROTECTION METHODS. | | | UNDERGROUND PIPING SHALL COMPLY WITH ONE OR MORE OF THE | | | FOLLOWING: | | | 1.THE PIPING SHALL BE MADE OF CORROSION-RESISTANT | | | MATERIAL THAT IS SUITABLE FOR THE ENVIRONMENT IN WHICH | | | IT WILL BE INSTALLED. | | | 2.PIPE SHALL HAVE A FACTORY-APPLIED, ELECTRICALLY | | | INSULATING COATING. FITTINGS AND JOINTS BETWEEN | | | SECTIONS OF COATED PIPE SHALL BE COATED IN ACCORDANCE | | | WITH THE COATING MANUFACTURER?S INSTRUCTIONS. | | | 3.THE PIPING SHALL HAVE A CATHODIC PROTECTION SYSTEM | | | INSTALLED AND THE SYSTEM SHALL BE MONITORED AND | | | MAINTAINED IN ACCORDANCE WITH AN APPROVED PROGRAM. | | | | | | REFER TO SECS. G2412.3 & G2412.4 FBC RES AND PROVIDE A | | | COMPLETE GAS RISER AND PLAN FOR THE RESIDENCE THAT | | | INCLUDES THE FOLLOWING INFORMATION: | | | A) DELIVERY PRESSURE AT THE METER. | | | B) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. | | | C) TYPES AND SIZES OF PIPING SUPPLYING THE EXISTING | | | APPLIANCES AND THE NEW WATER HEATER. | | | D) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER | | | TO THE MOST REMOTE APPLIANCE OUTLET. | | | E) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. | | | F) LOCATIONS OF REGULATORS AND SHUTOFF VALVES. | | | G) OUTLET PRESSURES AT REGULATORS. | | | H) LOCATIONS AND TYPES OF PIPE SLEEVES. | | | I) PIPE SIZING TABLES | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | CCOLE@WPB. | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-06-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-22 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-22 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2022-06-22 07:43:51 | 1ST REVIEW FBC-2020 RES. GAS | | | | | | PERMIT- 22051470 | | | | | | 6/22/22 | | | | | | CODES IN EFFECT: | | | | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | | | | FS- FLORIDA STATUTES | | | | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS P-1, P-2: PROVIDE A GAS RISER DRAWING FOR THE | | | RELOCATED TANKLESS WATER HEATER- SEC. 107.3.5.3 WPB. | | | | | | 2) P-1: THE RELOCATED GAS WATER HEATER APPEARS TO BE | | | WITHIN THE REQUIRED 4 FT. HORIZONTAL CLEARANCE TO THE | | | WINDOW. PLEASE PROVIDE CLEARANCE DISTANCE MEASUREMENTS | | | ON THE PLAN TO COMPLY WITH SECS. G2427.8 & G2448.1 FBC | | | RES. | | | | | | 3) P-1: PROVIDE A NOTE ON PLACE A NOTE INDICATE | | | CONDENSATE FROM THE WATER HEATER WILL BE NEUTRALIZED | | | PER THE MANUFACTURER'S SPECIFICATIONS AND CONVEY TO A | | | DISPOSAL LOCATION A MINIMUM OF 12-INCHES FROM THE | | | BUILDING- SEC. 307.2 FBC FG. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | | | | 401 CLEMATIS STREET | | | | | | WEST PALM BEACH FL 33401 | | | | | | 561-805-6719 | | | | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-09-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-09-21 |
Time |
07:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-09-20 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-09-02 |
Time |
07:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-08-25 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-08-25 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-08-11 |
Time |
12:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-23 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-06-16 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-06-21 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-06-21 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-06-21 |
Time |
15:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-09-22 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-09-22 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-09-07 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-09-07 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-12 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-12 |
Time |
12:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-06-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-22 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-21 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-09-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-09-22 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-09-22 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-09-06 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-09-06 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-08-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-12 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-12 |
Time |
16:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-07-01 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-07-01 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-07-01 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2022-07-01 11:20:23 | ALL PLANS PASSED SIGNATURE REVIEW. MP |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-09-20 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-09-20 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-09-20 |
Time |
14:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-25 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-08-25 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-08-25 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-06-23 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-06-23 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-06-23 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|