Plan Review Details - Permit 22051468
Plan Review Stops For Permit 22051468
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-06-10 Cont ID  
Sent By cpuell Date 2022-06-10 Time 08:20 Rev Time 0.00
Received By cpuell Date 2022-06-10 Time 08:20 Sent To  
Notes
2022-06-10 08:22:06ADDRESS OF 1225 PALM BEACH LAKES BLVD HAD PREVIOUSLY
 BEEN AGREED UPON FOR DUNKIN DONUTS ON THIS SITE

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status N Date 2022-07-18 Cont ID  
Sent By scwelter Date 2022-07-18 Time 13:31 Rev Time 0.00
Received By scwelter Date 2022-07-18 Time 13:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-10-19 Cont ID  
Sent By rmcphers Date 2022-10-19 Time 09:40 Rev Time 0.00
Received By rmcphers Date 2022-10-19 Time 09:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-08-30 Cont ID  
Sent By rmcphers Date 2022-08-30 Time 11:56 Rev Time 0.00
Received By rmcphers Date 2022-08-30 Time 11:48 Sent To  
Notes
2022-08-30 11:56:19NEW COMMERCIAL BLDG
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) IN THE PRODUCT APPROVAL PROVIDED FOR THE ROOF FLAT
 DECK - PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN
 THE ROOFING PRODUCT APPROVAL - ROOFING SYSTEM TO BE
 USED ON THE PROVIDED PRODUCT APPROVAL MAY REQUIRE
 ADDITIONAL SIGNED AND SEALED ATTACHMENT DETAILS FROM AN
 ARCHITECT OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH
 REQUIRE A HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE
 PRODUCT APPROVAL.
  
 2) DRAWING A-7.0 - DETAIL 4 - THE TOILET PAPER
 DISPENSER DIMENSIONS FROM THE FACE OF THE TOILET SHOULD
 BE SHOWN TO THE CENTER OF THE TOILET PAPER DISPENSER.
 FBC A 604.7
  
 3) DRAWING A-7.0 - DETAIL 4 - GRAB BAR DIMENSIONS FROM
 THE FLOOR NEED TO BE SHOWN TO THE TOP OF THE GRAB BAR
 GRIPPING SURFACE - NOT THE CENTER. FBC 609.4
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-07-06 Cont ID  
Sent By rmcphers Date 2022-07-06 Time 13:32 Rev Time 0.00
Received By rmcphers Date 2022-07-06 Time 13:05 Sent To  
Notes
2022-07-06 13:31:56NEW COMMERCIAL BLDG
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, DOORS AND
 ROOFING SYSTEMS - ALL PRODUCT APPROVALS NEED TO BE
 REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER
 OF RECORD. FBC WPB 107.3.4
  
 2) PLEASE PROVIDE A SOIL (GEOTECHNICAL) REPORT FBC
 1803.1
  
 3) PLEASE SHOW THE SITE DRAINAGE ON THE SITE PLAN OR
 PROVIDE A STORM WATER DRAINAGE PLAN FBC WPB 107.2.5
  
 4) PLEASE PROVIDE A SURVEY.
  
 5) DRAWING A-7.0 - DETAIL 4 - THE TOILET PAPER
 DISPENSER DIMENSIONS FROM THE FACE OF THE TOILET SHOULD
 BE SHOWN TO THE CENTER OF THE TOILET PAPER DISPENSER.
 FBC A 604.7
  
 6) DRAWING A-7.0 - DETAIL 4 - GRAB BAR DIMENSIONS FROM
 THE FLOOR NEED TO BE SHOWN TO THE TOP OF THE GRAB BAR
 GRIPPING SURFACE - NOT THE CENTER. FBC 609.4
  
 7) A SEPARATE PERMIT IS REQUIRED FOR SIGNS, PARKING
 LOT, DUMPSTER.
  
 8) CANOPIES, ROOFING SYSTEMS, WINDOW AND DOOR PRODUCT
 APPROVALS MAY BE DEFERRED SUBMITTALS BY LISTING ITEMS
 TO BE DEFERRED ON THE CONSTRUCTION DOCUMENTS -
 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR
 DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING
 OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE
 IN GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING.
 THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED
 UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN
 APPROVED BY THE BUILDING OFFICIAL.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-09-16 Cont ID  
Sent By jleahy Date 2022-09-16 Time 14:15 Rev Time 0.00
Received By jleahy Date 2022-09-16 Time 13:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-07-15 Cont ID  
Sent By jleahy Date 2022-07-15 Time 14:24 Rev Time 0.00
Received By jleahy Date 2022-07-15 Time 13:55 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2022-06-14 Cont ID  
Sent By rrossano Date 2022-06-14 Time   Rev Time  
Received By rrossano Date 2022-06-14 Time   Sent To  
Notes
2022-06-14 14:27:06PASSED WITH PROVISO: UPLOAD CIVIL ENGINEERING PLANS AS
 APPROVED FOR FORMAL ENGINEERING SUBMITTAL E21020005.
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORDINATOR, CITY OF WPB
 ENGINEERING SERVICES DEPARTMENT
 (561) 494-1098, FAX: (561) 494-1116 EMAIL:
 [email protected]
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-08-15 Cont ID  
Sent By cwalker Date 2022-08-15 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-06-14 Cont ID  
Sent By cwalker Date 2022-06-14 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-06-14 12:18:14FIRE COMMENTS:
  
 PROVIDE DETAIL ON DOOR LOCKING HARDWARE FROM THE SIDE
 OF EGRESS FOR ALL INTERIOR AND EXTERIOR DOORS. NFPA
 101, 7.2.1.5
  
 PROVIDE DOOR WIDTH (DOOR OPENING CLEAR WIDTH) FOR
 WALK-IN FREEZER AND DRY STORAGE ROOM DOORS. NFPA
 7.2.1.2.3
  
 PROVIDE EXIT SIGNS AND EMERGENCY LIGHTS FOR THE WALK-IN
 FREEZER AND DRY STORAGE ROOM. NFPA 101 7.9 & 7.10
  
 PROVIDE LISTING INFORMATION/ TEST DATA FOR THE TORNADO
 OVEN FOR VENTLESS APPLICATIONS. NFPA 96 12.1
  
 C. WALKER
 561-804-4762
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2022-11-04 Time   Rev Time 0.00
Received By lmarchan Date 2022-10-20 Time 15:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-10-19 Cont ID  
Sent By rmcphers Date 2022-10-19 Time 09:55 Rev Time 0.00
Received By rmcphers Date 2022-09-27 Time 07:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-09-16 Cont ID  
Sent By jleahy Date 2022-09-16 Time 14:15 Rev Time 0.00
Received By jleahy Date 2022-08-14 Time 09:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-19 Cont ID  
Sent By aoliver Date 2022-07-19 Time 07:29 Rev Time 0.00
Received By aoliver Date 2022-06-09 Time 09:54 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-01-04 Cont ID  
Sent By aoliver Date 2023-01-04 Time 16:44 Rev Time 0.00
Received By aoliver Date 2022-11-18 Time 09:12 Sent To  
Notes
2023-01-04 16:44:29NO IMPCAT FEES DUE, SEE EMAIL UPLOADED AO
2022-11-18 09:12:2611/18/22 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-07-06 Cont ID  
Sent By rmcphers Date 2022-07-06 Time 13:32 Rev Time 0.00
Received By rmcphers Date 2022-07-06 Time 13:32 Sent To  
Notes
2022-07-06 13:33:20PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-10-18 Cont ID  
Sent By medwards Date 2022-10-18 Time 06:07 Rev Time 0.00
Received By medwards Date 2022-10-18 Time 06:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-08-29 Cont ID  
Sent By medwards Date 2022-08-29 Time 06:06 Rev Time 0.00
Received By medwards Date 2022-08-29 Time 06:05 Sent To  
Notes
2022-08-29 06:07:17PLEASE ADDRESS 1ST CYCLE COMMENTS BELOW. THE RESPONSE
 LETTER SUBMITTED THIS CYCLE INDICATED CORRECTIONS WERE
 MADE BUT THEY WERE NOT SUBMITTED.
  
 1ST REVIEW FMC
 PERMIT: 22051468
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE THE ENERGY CALCULATIONS. FEC C402
  
 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FEC C403.2.1
  
 3) ADD A NOTE ON THE MECHANICAL DRAWING STATING THE
 REFRIGERATION WILL NEED A SEPARATE PERMIT AND REVIEW AS
 IT WILL NOT BE REVIEWED UNDER THIS PERMIT.
  
 4) ADD A NOTE TO THE MECHANICAL DRAWING STATING THE
 HOODS SYSTEMS WILL NEED A SEPARATE PERMIT AND REVIEW AS
 IT WILL NOT BE REVIEWED UNDER THIS PERMIT.
  
 5) PROVIDE GUARD PROTECTION FOR EQUIPMENT ON THE ROOF.
 FMC 304.11
  
 6) PROVIDE THE OCCUPANCY CLASSIFICATION FOR THE OUTDOOR
 AIR CALCULATIONS BASE ON USE OF SPACE FROM FMC
 403.3.1.1 AND TABLE 403.3.1.1
  
 7) PROVIDE SPECS. FOR THE COOKING EQUIPMENT. FMC 507.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-06-30 Cont ID  
Sent By medwards Date 2022-06-30 Time 13:48 Rev Time 0.00
Received By medwards Date 2022-06-30 Time 13:48 Sent To  
Notes
2022-06-30 13:48:231ST REVIEW FMC
 PERMIT: 22051468
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE THE ENERGY CALCULATIONS. FEC C402
  
 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FEC C403.2.1
  
 3) ADD A NOTE ON THE MECHANICAL DRAWING STATING THE
 REFRIGERATION WILL NEED A SEPARATE PERMIT AND REVIEW AS
 IT WILL NOT BE REVIEWED UNDER THIS PERMIT.
  
 4) ADD A NOTE TO THE MECHANICAL DRAWING STATING THE
 HOODS SYSTEMS WILL NEED A SEPARATE PERMIT AND REVIEW AS
 IT WILL NOT BE REVIEWED UNDER THIS PERMIT.
  
 5) PROVIDE GUARD PROTECTION FOR EQUIPMENT ON THE ROOF.
 FMC 304.11
  
 6) PROVIDE THE OCCUPANCY CLASSIFICATION FOR THE OUTDOOR
 AIR CALCULATIONS BASE ON USE OF SPACE FROM FMC
 403.3.1.1 AND TABLE 403.3.1.1
  
 7) PROVIDE SPECS. FOR THE COOKING EQUIPMENT. FMC 507.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2022-11-04 Cont ID  
Sent By ccole Date 2022-11-04 Time 10:26 Rev Time 0.00
Received By ccole Date 2022-11-04 Time 10:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2022-10-10 Cont ID  
Sent By rwbrown Date 2022-10-10 Time 13:50 Rev Time 0.00
Received By rwbrown Date 2022-10-10 Time 13:50 Sent To  
Notes
2022-10-10 13:57:43PENDING SIGNATURE ON PAGES P5.0 AND P6.0

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-08-29 Cont ID  
Sent By ccole Date 2022-08-29 Time 14:42 Rev Time 0.00
Received By ccole Date 2022-08-29 Time 13:31 Sent To  
Notes
2022-08-29 14:43:362ND REVIEW FBC-2020 PLUMBING
 PERMIT- 22051468
 8/29//2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES.
 BASED ON THE NARRATIVE RESPONSE TO COMMENTS IT APPEARS
 THAT SOME OF THE CORRECTED PLANS WERE NOT UPLOADED.
  
 1) FAILED. A-1.0: PROVIDE THE CLEAR FLOOR SPACE
 DIMENSIONS FOR THE ACCESSIBLE WATER CLOSET AND LAVATORY
 SINK- SECS. 604.3 & 606.2 FBC ACCO
 REQUESTED CLEAR FLOOR SPACE DIMENSIONS NOT PROVIDED
  
 2) FAILED. A-7.0: SHOW THE HEIGHT OF THE WATER CLOSET
 MEASURED FROM THE FINISHED FLOOR TO THE TOP OF THE
 SEAT- SEC. 604.4 FBC ACC.
 NOT PROVIDED. THE DETAIL 4 SHOWS THE HEIGHT DIMENSION
 MESURED TO THE RIM OF THE WATER CLOSET AND NOT THE SEAT
 AS REQUIRED.
  
 3) FAILED. A-7.0: SHOW THE HEIGHT OF THE GRAB BARS
 MEASURED FROM THE FINISHED FLOORS TO THE TOPS OF THE
 GRIPPING SURFACES- SEC. 609.4 FBC ACC.
 NOT PROVIDED. THE DETAIL 4 SHOWS THE HEIGHT DIMENSION
 MEASURED TO THE CENTER OF THE GRAB BARS AND NOT THE
 TOPS AS REQUIRED.
  
  
 4) FAILED. A-7.0: SHOW THE LOCATION OF THE TOILET PAPER
 DISPENSER MEASURED FROM THE FRONT OF THE WATER CLOSET
 TO THE CENTERLINE OF THE DISPENSER- SEC. 604.7 FBC ACC.
 THE DETAIL 4 SHOWS THE DIMENSION TO THE SIDE EDGE OF
 THE DISPENSER AND NOT THE CENTER AS REQUIRED.
  
 5) FAILED. P-1.0: THE DISCHARGES FROM THE HAND SINK,
 ICE MAKER, AND ICE BIN SHALL NOT DRAIN INTO THE GREASE
 INTERCEPTOR- SEC. 1003.3.1 FBC P.
 THE CORRECTIONS WERE NOT MADE TO THE PLAN.
  
 7) FAILED. P1.0: PROVIDE CLEANOUTS AT THE JUNCTIONS OF
 THE 2 AND 3-INCH SANITARY BUILDING DRAINS AND THE
 4-INCH SEWER LINE- SEC. 708.1.3 FBC P.
 THE CORRECTIONS WERE NOT MADE TO THE PLAN.
 10) FAILED. P-2.0 THE 1-INCH HOT WATER SUPPLY LINE TO
 THE LAVATORY IS EXCEEDING THE MAXIMUM .5 FT. DISTANCE
 FROM THE HOT WATER SOURCE- TABLE C404.5.1 FBC EC.
 THE CORRECTION WAS NOT MADE TO THE PLAN.
  
 14) FAILED. A- 4: PROVIDE ROOF DRAINAGE PLANS AND
 CALCULATIONS- SECS. 1101.2, 1101.7, 1105.1, 1106.1, &
 1108.1 FBC P.
 CALCULATIONS BASED ON RAINFALL RATE NOT PROVIDED. AREA
 AND GPM FLOW CALCULATIONS NOT PROVIDED.
 A) PROVIDE DOWNSPOUT SIZES. NOT PROVIDED
 C) PROVIDE AN OVERFLOW SCUPPER DETAIL. NOT PROVIDED.
 D) SHOW THE DRAINAGE FROM THE DOWNSPOUTS WILL DISCHARGE
 A MINIMUM OF 12-INCHES FROM THE BUILDING AND WILL BE
 CONVEYED TO AN APPROVED PLACE OF DISPOSAL.
  
 15) P-5.0: CORRECT THE 3-COMPARTMENT SINK DETAIL TO
 SHOW EACH WELL OF THE FIXTURE DRAINING INDIVIDUALLY
 INTO THE FLOOR SINK- SEC. 802.1.1 FBC P
  
 THE DETAIL SHOWS ONE OF THE THREE DRAINS DISCHARGING TO
 THE FLOOR SINK AND NOT TO THE GREASE INTERCEPTOR.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-06-28 Cont ID  
Sent By ccole Date 2022-06-28 Time 17:30 Rev Time 0.00
Received By ccole Date 2022-06-28 Time 16:59 Sent To  
Notes
2022-06-28 17:30:511ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22051468
 6/28/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) A-1.0: PROVIDE THE CLEAR FLOOR SPACE DIMENSIONS FOR
 THE ACCESSIBLE WATER CLOSET AND LAVATORY SINK- SECS.
 604.3 & 606.2 FBC ACC.
  
 2) A-7.0: SHOW THE HEIGHT OF THE WATER CLOSET MEASURED
 FROM THE FINISHED FLOOR TO THE TOP OF THE SEAT- SEC.
 604.4 FBC ACC.
  
 3) A-7.0: SHOW THE HEIGHT OF THE GRAB BARS MEASURED
 FROM THE FINISHED FLOORS TO THE TOPS OF THE GRIPPING
 SURFACES- SEC. 609.4 FBC ACC.
  
 4) A-7.0: SHOW THE LOCATION OF THE TOILET PAPER
 DISPENSER MEASURED FROM THE FRONT OF THE WATER CLOSET
 TO THE CENTERLINE OF THE DISPENSER- SEC. 604.7 FBC ACC.
  
 5) P-1.0: THE DISCHARGES FROM THE HAND SINK, ICE MAKER,
 AND ICE BIN SHALL NOT DRAIN INTO THE GREASE
 INTERCEPTOR- SEC. 1003.3.1 FBC P.
  
 6) P-1.0 & P2.0: SEPARATE PERMITS ARE REQUIRED FOR
 INSTALLATION OF THE GREASE INTERCEPTOR AND WATER
 SERVICE BACKFLOW PREVENTER- SECS. 105.1 & 107.2.1 WPB.
  
 DUE TO A CHANGE IN PROCESS, THE GREASE INTERCEPTOR AND
 BACKFLOW PREVENTER PERMITS ARE REQUIRED TO BE SUBMITTED
 PRIOR TO ISSUANCE OF THE PRIMARY PERMIT. YOU CAN SUBMIT
 AN APPLICATION ?TBD? (TO BE DETERMINED) IF YOU DO NOT
 HAVE A CONTRACTOR SELECTED BY EMAILING A COMPLETED
 PERMIT APPLICATION TO [email protected] . YOU
 WILL RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS.
 YOU MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT
 THE APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND
 THAT YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME.
 AFTER YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA
 EMAIL AND I WILL CHANGE THE REVIEW STATUS TO PASS.
  
 7) P1.0: PROVIDE CLEANOUTS AT THE JUNCTIONS OF THE 2
 AND 3-INCH SANITARY BUILDING DRAINS AND THE 4-INCH
 SEWER LINE- SEC. 708.1.3 FBC P.
  
 8) P-2.0: PROVIDE A MEANS OF LIMITING THE HOT WATER
 DELIVERY TEMPERATURE AT THE FIXTURES AND EQUIPMENT
 OTHER THAN THE WATER HEATER THERMOSTAT- SEC. 607.1.1
 FBC P. PROVIDE EITHER A MASTER THERMOSTATIC MIXING
 VALVE OR POINT OF USE MIXING VALVES.
  
 9) P-2.0: INDICATE HOW TEMPERED WATER WILL BE DELIVERED
 FROM THE LAVATORY- SEC. 419.4 & 607.1.2 FBC P.
  
 10) P-2.0 THE 1-INCH HOT WATER SUPPLY LINE TO THE
 LAVATORY IS EXCEEDING THE MAXIMUM .5 FT. DISTANCE FROM
 THE HOT WATER SOURCE- TABLE C404.5.1 FBC EC.
  
 11) P-2.0: SHOW THE LOCATIONS OF WATER HAMMER ARRESTORS
 FOR SUPPLY LINES TO FIXTURES AND EQUIPMENT WITH QUICK
 CLOSING VALVES- SECS. 604.9 FBC P.
  
 12) P-2.0 & P3.0: SHOW THE LOCATIONS OF BACKFLOW
 PREVENTERS FOR FILTERED WATER SUPPLY LINES TO THE
 COFFEE BREWERS, ESPRESSO MACHINE, SODA MACHINE, ICE
 MACHINE, ICE BIN, PROOFING CABINET, OVEN ETC.- SEC.
 608.3 FBC P. PLEASE INCLUDE A DEVICE SCHEDULE
 INDICATING THE MAKES, MODELS AND TYPES OF BACKFLOW
 PREVENTERSTO BE IINSTALLED.
  
 13) P2.0 P3.0: INDICATE HOW THE FILTRATION SYSTEM WILL
 PROTECTED FROM CONTAMINATION- SEC. 608.4 FBC P.
  
 14) A- 4: PROVIDE ROOF DRAINAGE PLANS AND CALCULATIONS-
 SECS. 1101.2, 1101.7, 1105.1, 1106.1, & 1108.1 FBC P.
 A) PROVIDE DOWNSPOUT SIZES.
 B) PROVIDE THE WIDTH DIMENSION OF THE SCUPPER ON DETAIL
 3.
 C) PROVIDE AN OVERFLOW SCUPPER DETAIL.
 D) SHOW THE DRAINAGE FROM THE DOWNSPOUTS WILL DISCHARGE
 A MINIMUM OF 12-INCHES FROM THE BUILDING AND WILL BE
 CONVEYED TO AN APPROVED PLACE OF DISPOSAL.
  
 14) P-5.0: CORRECT THE 3-COMPARTMENT SINK DETAIL TO
 SHOW EACH WELL OF THE FIXTURE DRAINING INDIVIDUALLY
 INTO THE FLOOR SINK- SEC. 802.1.1 FBC P
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2022-10-19 Cont ID  
Sent By rmcphers Date 2022-10-19 Time 09:40 Rev Time 0.00
Received By rmcphers Date 2022-10-19 Time 09:40 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2022-08-30 Cont ID  
Sent By rmcphers Date 2022-08-30 Time 11:56 Rev Time 0.00
Received By rmcphers Date 2022-08-30 Time 11:56 Sent To  
Notes
2022-08-30 11:57:09SEE BUILDING PLAN REVIEW

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-07-06 Cont ID  
Sent By rmcphers Date 2022-07-06 Time 13:33 Rev Time 0.00
Received By rmcphers Date 2022-07-06 Time 13:33 Sent To  
Notes
2022-07-06 13:34:02SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-11-04 Cont ID  
Sent By ccole Date 2022-11-04 Time 10:26 Rev Time 0.00
Received By ccole Date 2022-11-04 Time 10:26 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-10-19 Cont ID  
Sent By rmcphers Date 2022-10-19 Time 09:55 Rev Time 0.00
Received By rmcphers Date 2022-10-19 Time 09:52 Sent To  
Notes
2022-10-19 09:53:05SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) PLUMBING DRAWING P-5.0 AND THE CIVIL DRAWINGS
 PROVIDED DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE
 READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  
  
2022-10-18 06:07:50MECHANICAL DIGITAL SIGNATURES APPROVED ME
  
2022-10-10 13:56:41P-5.0 AND P-6.0 APPEAR TO HAVE NO SIGNATURE

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-08-30 Cont ID  
Sent By rmcphers Date 2022-08-30 Time 13:11 Rev Time 0.00
Received By rmcphers Date 2022-08-30 Time 13:10 Sent To  
Notes
2022-08-30 13:12:32SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) CIVIL DRAWINGS PROVIDED DO NOT SHOW AS DIGITALLY
 SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  
2022-08-29 14:49:34PLUMBING SHEETS OK.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-07-06 Cont ID  
Sent By rmcphers Date 2022-07-06 Time 13:36 Rev Time 0.00
Received By rmcphers Date 2022-07-06 Time 13:36 Sent To  
Notes
2022-06-30 13:49:01MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop Z ZONING
Rev No 3 Status P Date 2022-10-06 Cont ID  
Sent By vbroglia Date 2022-10-06 Time 11:28 Rev Time 0.00
Received By vbroglia Date 2022-10-06 Time 11:28 Sent To  
Notes
2022-10-06 11:30:14PASSED WITH PROVISO: UPLOAD APPROVAL LETTER FROM
 PLANNING AND ZONING SITE PLAN APPROVAL
  
  
  
 **** REVIEWD BY ****
 VALENTINA BROGLIA
 ASSOCIATE PLANNER
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2022-08-29 Cont ID  
Sent By vbroglia Date 2022-08-29 Time 10:55 Rev Time 0.00
Received By vbroglia Date 2022-08-29 Time 10:55 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-07-06 Cont ID  
Sent By vbroglia Date 2022-07-06 Time 16:17 Rev Time 0.00
Received By vbroglia Date 2022-07-06 Time 16:17 Sent To  
Notes
***NONE***