| Plan Review Stops For Permit 22051343 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
N |
Date |
2022-06-21 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2022-06-21 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2022-06-21 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2022-06-21 09:16:45 | SEE INT. DEMO 22061002 FOR ASBESTOS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-08-09 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-08-09 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2022-07-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-22 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-22 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-07-01 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-07-01 |
Time |
19:02 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-07-01 |
Time |
18:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-07-27 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-07-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-07-27 09:57:33 | FIRE PROVISO COMMENT: | | | INSTALL AN EXIT SIGN ON THE EGRESS SIDE OF THE DOOR | | | FROM TECH AREA (118) TO RECEPTION AREA (100), NOTE | | | ADDED TO SHEET E-2.1 | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-05-31 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-05-31 12:34:50 | FIRE COMMENTS: | | | THE COMMON PATH OF TRAVEL IN THE WAREHOUSE CANNOT | | | EXCEED 100 FEET. NFPA 101 42.2.4.1 & 42.2.5 | | | C. WALKER | | | 561-804-4762 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-24 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-09 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-08-09 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-26 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-22 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-27 |
Time |
06:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2022-07-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-22 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-22 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2022-07-22 14:43:33 | NO CHANGE OF OCCUPANCY TYPE - NO ADDED SQUARE FOOTAGE |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-24 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-24 |
Time |
08:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-07-28 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-28 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-28 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2022-07-28 11:32:17 | PROVIDE THE OUTDOOR AIR CALCULATIONS BASED ON FMC | | | 403.3.1.1 AND TABLE 403.3.1.1. THE MINIMUM OCCUPANTS | | | SHOULD COME FROM THE TABLE AND NOT FROM THE ARCHITECTS | | | EGRESS COUNTS. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-06-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-06-23 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-06-23 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2022-06-23 11:49:41 | 1ST REVIEW FMC | | | PERMIT: 22051343 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE OUTDOOR AIR CALCULATIONS BASED ON EACH | | | OCCUPANCY CLASSIFICATION IN THIS TENANT SPACE ACCORDING | | | TO FMC TABLE 403.3.1.1. THERE ARE TRAINING ROOMS, | | | CONFERENCE ROOMS STORAGE ROOMS AND A COPY ROOM IN THIS | | | TENANT SPACE. | | | | | | 2) PROVIDE A COMPLETE SCOPE OF WORK FOR THE MECHANICAL | | | SYSTEMS. FBC 107.2.1 | | | | | | 3) THE ENERGY CALCULATIONS DO NOT MATCH THE MECHANICAL | | | DRAWINGS. IS THERE ANY MECHANICAL UNITS BEING ADDED? | | | THE ENERGY CALCULATIONS ARE CALLING FOR BOTH RTU?S AND | | | AHU?S. THE ENERGY CALCULATIONS SHOW THE WAREHOUSE TO BE | | | UNCONDITIONED. | | | | | | 4) EXPLAIN THE NEW EF-4. FBC 107.2.1 | | | | | | 5) IS THE WALL SEPARATING THE OFFICE SPACE FROM THE | | | WAREHOUSE A RATED WALL? FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-06-22 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-06-22 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-06-22 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-24 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-24 |
Time |
08:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-07-28 11:34:32 | THE MECHANICAL DOCUMENTS ARE MISSING THE DIGITAL | | | SIGNATURE OF THE DESIGNER. PROVIDE DOCUMENTS WITH THE | | | DESIGNERS DIGITAL SIGNATURE. FS471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-07-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-22 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-22 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2022-06-23 11:50:13 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|