Plan Review Details - Permit 22051265
Plan Review Stops For Permit 22051265
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 5 Status P Date 2022-08-30 Cont ID  
Sent By pvalenti Date 2022-08-30 Time 16:33 Rev Time 0.00
Received By pvalenti Date 2022-08-30 Time 16:20 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 4 Status F Date 2022-08-25 Cont ID  
Sent By pvalenti Date 2022-08-25 Time 15:52 Rev Time 0.00
Received By pvalenti Date 2022-08-25 Time 15:52 Sent To  
Notes
2022-08-25 15:55:32PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 FAILED ASBESTOS REVIEW:
  
 MISSING ADDRESS OF PROJECT LOCATION ON ASBESTOS
 ACKNOWLEDGEMENT LETTER.
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION
 -RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status F Date 2022-08-25 Cont ID  
Sent By pvalenti Date 2022-08-25 Time 08:03 Rev Time 0.00
Received By pvalenti Date 2022-08-25 Time 07:41 Sent To  
Notes
2022-08-25 08:05:21PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 3RD ASBESTOS REVIEW DENIED:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-08-05 Cont ID  
Sent By pvalenti Date 2022-08-05 Time 16:01 Rev Time 0.00
Received By pvalenti Date 2022-08-05 Time 07:09 Sent To  
Notes
2022-08-05 16:03:24PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 ASBESTOS REVIEW DENIED:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-06-06 Cont ID  
Sent By pvalenti Date 2022-06-06 Time 10:23 Rev Time 0.00
Received By pvalenti Date 2022-06-02 Time 16:10 Sent To  
Notes
2022-06-06 10:25:24PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 ASBESTOS REVIEW:
  
 FAILED PLAN REVIEW, COMMERCIAL:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
2022-06-02 16:12:46JESMITH SIGNED IN BY ACCIDENT JS

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-08-30 Cont ID  
Sent By pvalenti Date 2022-08-30 Time 17:09 Rev Time 0.00
Received By pvalenti Date 2022-08-30 Time 16:20 Sent To  
Notes
2022-08-30 17:16:17PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW APPROVED WITH PROVISO:
  
 SOUND TRANSMISSION, IMPACT INSULATION, & FLAME SPREAD
 TEST REPORTS FOR THE FLOORING/FLOORING UNDERLAYMENT
 MUST BE APPROVED BY THE BUILDING OFFICIAL PRIOR TO
 FLOORING WORK. SEE CONSTRUCTION NOTES ON PLAN SHEETS
 A-0.1 & A-0.2.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-08-25 Cont ID  
Sent By pvalenti Date 2022-08-25 Time 09:01 Rev Time 0.00
Received By pvalenti Date 2022-08-25 Time 07:41 Sent To  
Notes
2022-08-25 09:21:38PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 3.) FBC B 107.2.1/FBC B 107.3.4.1, THE PROPOSED
 FLOORING/FLOORING UNDERLAYMENT TEST REPORTS ARE
 REQUIRED FOR:
 A.) SOUND TRANSMISSION (NOT LESS THAN 50) ASTM E-90.
 B.) IMPACT INSULATION (NOT LESS THAN 50) ASTM E-492.
 C.) FLAME SPREAD SPECIFICATION (NOT MORE THAN 200) ASTM
 E-84.
  
 FBC B 107.3.4.1, IF THE INTENTION IS TO DEFER THESE
 SUBMITTALS, PLEASE LIST THESE SUBMITTAL ITEMS ON THE
 CONSTRUCTION DOCUMENTS/PLANS. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-08-11 Cont ID  
Sent By pvalenti Date 2022-08-11 Time 12:50 Rev Time 0.00
Received By pvalenti Date 2022-08-05 Time 07:09 Sent To  
Notes
2022-08-11 12:50:39PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING 2ND REVIEW DENIED:
  
 1.) FBC B 310.4, THE OCCUPANCY INDICATED ON THESE PLAN
 SHEETS IS "R-1" BUT THE FLORIDA BUILDING CODE SHOWS
 THIS AS AN "R-2".
  
 2.) FBC R 101.2 & FBC B 101.2, ON PLAN SHEETS A-01&
 A-02, UNDER CONSTRUCTION NOTES, THE INDICATION IS THAT
 THE INFORMATION IS UNDER THE REQUIREMENTS OF THE
 RESIDENTIAL CODE. IT APPEARS THAT THIS PROJECT FALLS
 UNDER THE REQUIREMENTS OF THE FLORIDA BUILDING CODE
 "BUILDING" NOT RESIDENTIAL.
  
 3.) FBC B 107.2.1, THE NEW FLOORING, INCLUDING THE
 UNDERLAYMENT, NEEDS TO COMPLY WITH THE FOLLOWING:
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
  
 4.) FBC A 611, PROVIDE THE MEASUREMENTS WITHIN THE
 LAUNDRY ROOMS TO SHOW COMPLIANCE WITH ACCESSIBLE
 REQUIREMENTS INCLUDING CLEAR FLOOR, WHEEL CHAIR
 APPROACH AND REACH REQUIREMENTS.
  
 5.) FBC B 2403.1, 2403.2, 2403.3, & 2403.4, PROVIDE THE
 REQUIRED DETAILS FOR THE GLASS SHOWER ENCLOSURE AS PER
 THE GLASS & GLAZING SECTIONS OF THE FLORIDA BUILDING
 CODE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-06-06 Cont ID  
Sent By pvalenti Date 2022-06-06 Time 09:49 Rev Time 0.00
Received By pvalenti Date 2022-06-03 Time 16:46 Sent To  
Notes
2022-06-06 10:04:35PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1.) FBC B 310.4, THE OCCUPANCY INDICATED ON THESE PLAN
 SHEETS IS "R-1" BUT THE FLORIDA BUILDING CODE SHOWS
 THIS AS AN "R-2".
  
 2.) FBC R 101.2 & FBC B 101.2, ON PLAN SHEETS A-01&
 A-02, UNDER CONSTRUCTION NOTES, THE INDICATION IS THAT
 THE INFORMATION IS UNDER THE REQUIREMENTS OF THE
 RESIDENTIAL CODE. IT APPEARS THAT THIS PROJECT FALLS
 UNDER THE REQUIREMENTS OF THE FLORIDA BUILDING CODE
 "BUILDING" NOT RESIDENTIAL.
  
 3.) FBC B 107.2.1, THE NEW FLOORING, INCLUDING THE
 UNDERLAYMENT, NEEDS TO COMPLY WITH THE FOLLOWING:
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
  
 4.) FBC A 611, PROVIDE THE MEASUREMENTS WITHIN THE
 LAUNDRY ROOMS TO SHOW COMPLIANCE WITH ACCESSIBLE
 REQUIREMENTS INCLUDING CLEAR FLOOR, WHEEL CHAIR
 APPROACH AND REACH REQUIREMENTS.
  
 5.) FBC B 2403.1, 2403.2, 2403.3, & 2403.4, PROVIDE THE
 REQUIRED DETAILS FOR THE GLASS SHOWER ENCLOSURE AS PER
 THE GLASS & GLAZING SECTIONS OF THE FLORIDA BUILDING
 CODE.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-08-29 Cont ID  
Sent By jleahy Date 2022-08-29 Time 14:29 Rev Time 0.00
Received By jleahy Date 2022-08-29 Time 14:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-07-23 Cont ID  
Sent By jleahy Date 2022-07-23 Time 12:28 Rev Time 0.00
Received By jleahy Date 2022-07-23 Time 12:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-06-03 Cont ID  
Sent By jleahy Date 2022-06-03 Time 16:13 Rev Time 0.00
Received By jleahy Date 2022-06-03 Time 15:58 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2022-08-31 Cont ID  
Sent By pleduc Date 2022-08-31 Time   Rev Time 0.00
Received By pleduc Date 2022-08-31 Time 07:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2022-08-26 Cont ID  
Sent By pleduc Date 2022-08-26 Time   Rev Time 0.00
Received By pleduc Date 2022-08-26 Time 10:12 Sent To  
Notes
2022-08-26 10:12:29FIRE PROVISO:
  
 THE FIRE ALARM & FIRE SPRINKLER SYSTEMS REQUIRE
 MODIFICATION AS A RESULT OF THIS PROJECT.
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-08-22 Cont ID  
Sent By pleduc Date 2022-08-22 Time   Rev Time 0.00
Received By pleduc Date 2022-08-22 Time 12:18 Sent To  
Notes
2022-08-22 12:18:49FIRE PROVISO:
  
 THE FIRE ALARM & FIRE SPRINKLER SYSTEMS REQUIRE
 MODIFICATION AS A RESULT OF THIS PROJECT.
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-07-19 Cont ID  
Sent By pleduc Date 2022-07-19 Time   Rev Time 0.00
Received By pleduc Date 2022-07-19 Time 15:10 Sent To  
Notes
2022-07-19 15:22:20FIRE PROVISO:
  
 THE FIRE ALARM & FIRE SPRINKLER SYSTEMS REQUIRE
 MODIFICATION AS A RESULT OF THIS PROJECT.
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-05-27 Cont ID  
Sent By pleduc Date 2022-05-27 Time   Rev Time 0.00
Received By pleduc Date 2022-05-27 Time 15:15 Sent To  
Notes
2022-05-27 15:18:16FIRE PROVISO:
  
 THE FIRE ALARM & FIRE SPRINKLER SYSTEMS REQUIRE
 MODIFICATION AS A RESULT OF THIS PROJECT.
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-08-31 Cont ID  
Sent By pvalenti Date 2022-08-31 Time 13:45 Rev Time 0.00
Received By pvalenti Date 2022-08-31 Time 13:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-08-31 Cont ID  
Sent By jleahy Date 2022-08-31 Time 08:19 Rev Time 0.00
Received By jleahy Date 2022-08-30 Time 15:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-08-29 Cont ID  
Sent By jleahy Date 2022-08-29 Time 14:29 Rev Time 0.00
Received By jleahy Date 2022-08-21 Time 09:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-08-11 Cont ID  
Sent By pvalenti Date 2022-08-11 Time 12:51 Rev Time 0.00
Received By pvalenti Date 2022-07-18 Time 10:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-06-08 Cont ID  
Sent By aoliver Date 2022-06-08 Time 07:07 Rev Time 0.00
Received By aoliver Date 2022-05-26 Time 07:01 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2022-08-31 Cont ID  
Sent By pvalenti Date 2022-08-31 Time 13:44 Rev Time 0.00
Received By pvalenti Date 2022-08-31 Time 13:44 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-06-06 Cont ID  
Sent By pvalenti Date 2022-06-06 Time 10:46 Rev Time 0.00
Received By pvalenti Date 2022-06-03 Time 16:46 Sent To  
Notes
2022-06-06 10:47:33PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-08-25 Cont ID  
Sent By medwards Date 2022-08-25 Time 06:34 Rev Time 0.00
Received By medwards Date 2022-08-25 Time 06:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-07-19 Cont ID  
Sent By medwards Date 2022-07-19 Time 10:31 Rev Time 0.00
Received By medwards Date 2022-07-19 Time 10:31 Sent To  
Notes
2022-07-19 10:30:591) PROVIDE THE CHILLED WATER PIPING DETAILS FOR THE NEW
 FCU'S. FBC 107.2.1
  
 2) PROVIDE THE BATH EXHAUST TIE IN DETAIL TO THE
 EXHISTING EXHAUST SYSTEM. FBC 107.2.1
  
 3) PROVIDE THE DRYER DUCT DETAILS, SIZING MATERIAL AND
 LENGTH OF EXHAUST DUCT ALONG WITH THE TERMINATION
 LOCATION. FMC 504
  
 4) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR THESE DORM
 ROOMS AND HOW IT WILL BE INTRODUCED. FMC 403.3.1.1 AND
 TABLE 403.3.1.1
  
 5) PROVIDE A CONDENSATE DETAIL SHOWING THE PIPE
 MATERIAL, SIZE AND LOCATION OF TERMINATION LOCATION.
 FMC 307
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-05-31 Cont ID  
Sent By medwards Date 2022-05-31 Time 07:05 Rev Time 0.00
Received By medwards Date 2022-05-31 Time 07:05 Sent To  
Notes
2022-05-31 07:06:34PROVIDE A COMPLETE MECHANICAL DESIGN FOR THIS CHANGE OF
 USE OF SPACE IN THE EXISTING BUILDING. FBC 107.2.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 5 Status P Date 2022-08-25 Cont ID  
Sent By rwbrown Date 2022-08-25 Time 14:17 Rev Time 0.00
Received By rwbrown Date 2022-08-25 Time 14:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2022-08-24 Cont ID  
Sent By rwbrown Date 2022-08-24 Time 12:27 Rev Time 0.00
Received By rwbrown Date 2022-08-24 Time 12:27 Sent To  
Notes
2022-08-24 12:28:00SIMPLIFIED COMMENTS
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FPC 315.1 - PLEASE ADD TO YOUR FIRE STOPPING
 DETAILS PROVISIONS FOR PVC PENETRATIONS. IT APPEARS
 THAT ALL OF THEM ARE FOR "METALLIC" PIPE. MAKE SURE YOU
 HAVE A UL RATED LISTING FOR EACH TYPE OF PIPE
 PENETRATION. THE INSPECTOR WILL NEED THESE AND HAVING
 THEM SUBMITTED NOW WILL SAVE TIME WITH REVISIONS LATER.
  
 2. 2020 FEC TABLE C403.2.10 - CHANGE NOTE 14 TO STATE
 THE MINIMUM PIPE INSULATION THICKNESS IS 1", NOT 1/2".
  
 3. 2017 WPB AMENDS 107.2.1 - YOU'VE SPEC'D OUT TOILETS
 THAT ARE 10.5" TALL. CAN YOU CLARIFY THAT THESE ARE FOR
 CHILDREN? IF NOT, CHANGE THE TOILET SPECIFICATION.
 ALSO, PLEASE CORRECT THE TAGS ON THE RISER DIAGRAMS TO
 CORRESPOND WITH THE ACTUAL FIXTURES INSTALLED.
  
 4. 2020 FPC TABLE 709.1 - THE RISER SHOWS A TRAP SIZE
 OF 1" FOR THE FLOOR DRAIN. THE MINIMUM TRAP SIZE IS 2",
 PLEASE CHANGE.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2022-08-23 Cont ID  
Sent By jesmith Date 2022-08-23 Time 17:06 Rev Time 0.00
Received By jesmith Date 2022-08-23 Time 16:44 Sent To  
Notes
2022-08-23 16:55:55CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22051265 300 PEMBROKE PL
  
 3RD REVIEW
 PLUMBING COMMENTS: DENIED
  
 8. THIRD REQUEST:P-05/PLUMBING NOTES: PER WPB FBC
 107.2.1, REVISE THE FOLLOWING
 ***A) NOTES 6 & 7 "PVC DRAINAGE (DWV) SCHEDULE 40 PIPE
 AND FITTINGS" ORIGINAL NOTE 7 ADDRESSED SANITARY PIPE
 SPECIFICATIONS WHICH WAS PVC SCHEDULE 40 PIPE AND
 FITTINGS. NOTE 7 NOW ADDRESSES CONDENSATE PIPE; PROVIDE
 SANITARY DWV DRAINAGE PIPING SPECIFICATION. PLEASE NOTE
 THAT P-10 AND P-11 DETAILS DO NOT PROVIDE A RATED
 ASSEMBLY FOR PVC THROUGH THE FLOOR PENETRATIONS AND IF
 PVC IS TO BE USED A RATED ASSEMBLY SHALL BE PROVIDED.
 ***D) NOTE 16 "HOT WATER PIPING TO BE INSULATED IN
 ACCORDANCE WITH FBC EC C404.4 (A-E) AND TABLE
 C403.2.10" TABLE C403.2.10 INDICATES MINIMUM THICKNESS
 SHALL BE 1" NOT 1/2" AS NOTED IN NEW NOTE 14 WHICH
 CALLS FOR 1/2 " ARMAFLEX; MAKE CORRECTION. PROVISION
 FOR WATER HAMMER ARRESTORS TO COMPLY WITH ASSE 1010 PER
 604.9 IS CORRECT.
  
 10. THIRD REQUEST: PARTIALLY COMPLIED. RESPONSE WAS
 LISTED ON P-05, NOTE 29(A), (B) P-05; NO DETAIL WAS
 PROVIDED PER WPB FBC 107.2.1, PROVIDE A CROSS-SECTION
 SHOWER WALL/FLOOR/DRAIN AND THRESHOLD DETAIL.
  
 13. THIRD REQUEST: PER WPB FBC 107.2.1, PROVIDE
 APPLICABLE RATED WALL/FLOOR DETAILS FOR PLUMBING
 PENETRATIONS COMPLYING WITH THE REQUIREMENTS OF FBC
 CHAPTER 7. PARTIALLY COMPLIED. SEE COMMENT 8/***A)
 NOTES 6 & 7 "PVC DRAINAGE (DWV) SCHEDULE 40 PIPE AND
 FITTINGS" ORIGINAL NOTE 7 ADDRESSED SANITARY PIPE
 SPECIFICATIONS WHICH WAS PVC SCHEDULE 40 PIPE AND
 FITTINGS. NOTE 7 NOW ADDRESSES CONDENSATE PIPE; PROVIDE
 SANITARY DWV DRAINAGE PIPING SPECIFICATION. PLEASE NOTE
 THAT P-10 AND P-11 DETAILS DO NOT PROVIDE A RATED
 ASSEMBLY FOR PVC THROUGH THE FLOOR PENETRATIONS AND IF
 PVC IS TO BE USED A RATED ASSEMBLY SHALL BE PROVIDED.
  
 18. THIRD REQUEST: P-01/EXISTING FLOOR DRAIN: PER WPB
 FBC 107.2.1, CONFIRM THAT THE EXISTING FLOOR DRAIN IN
 THE NEW BATHROOM HAS A TRAP PRIMER AND INDICATE ON THE
 PLAN HOW IT IS PROVIDED. IF NOT, THEN PER FBC PL
 1002.4.1, PROVIDE TRAP SEAL PROTECTION IN ACCORDANCE
 WITH ONE OF THE METHODS IN SECTIONS 1002.4.1.1 THROUGH
 1002.4.1.4. ADDITIONALLY, PROVIDE A SCHEMATIC DETAIL.
 RESPONSE REFERENCES NEW FIXTURE SCHEDULE BUT NOTED
 FLOOR DRAIN DOES NOT CORRESPOND WITH FIXTURE SCHEDULE.
 PLEASE SHOW TRAP PIMER CONNECTION TO FLOOR DRAIN AND
 PROVIDE SPEC AND DETAIL
  
 20. THIRD REQUEST: P-05/SANITARY RISER SERVICING ONLY
 FLOORS 2 THROUGH 4: PER FBC PL 912.1.1, THE SHOWER
 DRAIN ON THE FOURTH FLOOR SHALL CONNECT TO THE STACK AT
 OR ABOVE THE WATER CLOSET ELEVATION. PLEASE NOTE ALSO
 THAT ANY TIME A WATER CLOSET AND OTHER BATHROOM GROUP
 FIXTURES ARE CONNECTED TO ANY VERTICAL WET VENT, THE
 OTHER FIXTURES SHALL CONNECT AT OR ABOVE THE ELEVATION
 WITH THE WATER CLOSET AS NOTED IN 912.1.1. CLARIFY;
 EACH BATHROOM GROUP ON SECOND AND THIRD FLOOR SHALL BE
 VENTED BEFORE CONNECTING TO THE STACK. THE SHOWER SHALL
 CONNECT AT OR ABOVE THE WATER CLOSET.
  
 23. SECOND REQUEST: PER WPB FBC 107.2.1, ID/TAG THE
 SANITARY AND WATER RISERS ON BOTH RISER DIAGRAMS AND
 FLOOR PLANS. ID/TAG SHALL MATCH ON THE CORRESPONDING
 DRAWINGS. SEE COMMENT 7 REGARDING THE FIXTURE SCHEDULE.
 PARTIALLY COMPLIED
 NEW COMMENTS
 ***A) REGARDING THE WATER CLOSETS, P-06 SANITARY RISERS
 SHOWS WC-2/A.S. 2315228 10-1/4 INCH HIGH BOWL ON RISER
 SERVICING ONLY FLOORS 2, 3 AND 4; WC-1/KOHLER 3544EB
 HANDICAP ARE SHOWN ON RISER SERVICING FLOORS 1, 2, 3
 AND 4. P-01 AND P-02 FLOOR PLANS SHOW WC-2/A.S. 2315228
 10-1/4 INCH HIGH BOWL IN ALL LOCATIONS
 ***B) REGARDING THE LAVATORIES, P-06 SANITARY RISERS
 SHOWS L-3/A.S.0614000 UNDERMOUNT ON RISER SERVICING
 ONLY FLOORS 2, 3 AND 4; L-1/KOHLER 2032 WALL HUNG ARE
 SHOWN ON RISER SERVICING FLOORS 1, 2, 3 AND 4. P-01 AND
 P-02 FLOOR PLANS SHOW L-3/A.S.0614000 UNDERMOUNT IN ALL
 LOCATIONS.
 ***C) PER WPB FBC 107.2.1, PLEASE CLARIFY AND RECONCILE
 ***D) REGARDING THE FLOOR DRAIN, MINIMUM SIZE FLOOR
 DRAIN IS 2" PER FBC PL TABLE 709.1. P-06 SHOWS 1-1/2"
 SIZE; ADDITIONALLY, PROVIDE A P-TRAP ON DRAWING.
  
 25. SECOND REQUEST: PER WPB FBC 107.2.1, PLEASE
 INDICATE ON THE PLANS IF THE HOT WATER SYSTEM IS
 RECIRCULATED OR HEAT TRACED; PROVIDE THE TEMPERATURE OF
 THE HOT WATER.
 TO BE CLEAR, PER FBC PL 607.2, THE DEVELOPED LENGTH OF
 HOT OR TEMPERED WATER PIPING FROM THE SOURCE OF HOT
 WATER TO THE FIXTURE SHALL NOT EXCEED 50 FEET.
 RECIRCULATING SYSTEMS AND HEAT TRACED SYSTEMS ARE
 CONSIDERED TO BE SOURCES OF HOT OR TEMPERED WATER.
 PLEASE SHOW THAT THE HOT OR TEMPERED WATER FROM THE
 SOURCE TO THE FIXTURES DOES NOT EXCEED 50 FEET OR
 PROVIDE MEANS TO COMPLY. PARTIALY COMPLIED
 P-07/WATER RISER DISTRIBUTION NOTES A CLOSED LOOP
 RECIRCULATION BETWEEN THE WATER HEATER AND A HOT WATER
 STORAGE TANK WITH A NON RECIRCULATED WATER LINE TO HOT
 WATER DISTRIBUTION. PER FBC PL 607.2 AND FBC RES
 P2601.1, THE DEVELOPED LENGTH OF HOT OR TEMPERED WATER
 PIPING FROM THE SOURCE OF HOT WATER TO THE FIXTURE
 SHALL NOT EXCEED 50 FEET. RECIRCULATING SYSTEMS AND
 HEAT TRACED SYSTEMS ARE CONSIDERED TO BE SOURCES OF HOT
 OR TEMPERED WATER. PLEASE SHOW THAT THE HOT OR TEMPERED
 WATER FROM THE SOURCE TO THE FIXTURES DOES NOT EXCEED
 50 FEET OR PROVIDE MEANS TO COMPLY.
 PER WPB FBC 107.2.1, PROVIDE A COMPLIANT SYSTEM. PLEASE
 NOTE THAT A TANKLESS WATER HEATER CAPABLE OF SUPPORTING
 ADEQUATE HOT WATER DEMAND IN EACH NEW BATHROOM IS
 CONSIDERED AN ADEQUATE SOURCE OF HOT WATER. THE UNIT
 WOULD REQUIRE A SCHEDULE WITH GPM AND ELECTRICAL
 CHARACTERISTICS. LOCATION(S) ON FLOOR PLANS, RISER
 DIAGRAM AND A DETAIL WOULD BE REQUIRED. ADDITIONALLY, A
 NEW ELECTRICAL REVIEW WOULD BE REQUIRED.
  
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 PLEASE PROVIDE A DETAILED RESPONSE LETTER ADDRESING
 EACH ITEM/COMMENT.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 PLUMBING INSPECTOR BN2148
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-07-21 Cont ID  
Sent By jesmith Date 2022-07-19 Time 15:37 Rev Time 0.00
Received By jesmith Date 2022-07-19 Time 10:46 Sent To  
Notes
2022-07-19 15:35:23CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22051265 300 PEMBROKE PL
  
 2ND REVIEW
 PLUMBING COMMENTS: DENIED
  
 RESPONSE AND/OR CORRECTIONS IN RESPONSE TO THE FIRST
 REVIEW WERE NOT PROVIDED BY THE DESIGN PROFESSIONAL(S).
 IN ADDITION TO THE ORIGINAL COMMENTS, NEW COMMENTS HAVE
 BEEN ADDED. IT IS IMPORTANT THAT ALL COMMENTS ARE
 RESPONDED TO, AND CORRECTIONS MADE FOR APPROVAL. PLEASE
 BE SURE TO PROVIDE A RESPONSE LETTER ADDRESSING EACH
 COMMENT, NOTING THE PLAN PAGE SHOWING THE CORRECTIONS.
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1. SECOND REQUEST: PLEASE NOTE FBC ACC 202.4.1,
 DISPROPORTIONATE COST: ALTERATIONS MADE TO PROVIDE AN
 ACCESSIBLE PATH OF TRAVEL TO THE ALTERED AREA WILL BE
 DEEMED DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN
 THE COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO
 THE PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS
 EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING
 AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING
 RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS,
 ENLARGING TOILET STALLS, INSULATING PIPES, OR
 INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS
 ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH
 AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT,
 INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT
 TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING
 AN INACCESSIBLE DRINKING FOUNTAIN.
 TO BE CLEAR, A RESPONSE IS REQUIRED.
  
 ***A) PER WPB FBC 107.2.1, PROVIDE DIMENSIONED PLAN AND
 ELEVATION VIEW OF EXISTING MEN AND WOMEN TOILET ROOMS
 SHOWING COMPLIANCE WITH FBC ACC CHAPTERS 2, 3 AND 6 AS
 FOLLOWS:
 *****1) THE WATER CLOSET SHALL BE POSITIONED WITH A
 WALL OR PARTITION TO THE REAR AND TO ONE SIDE. THE
 CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES
 MINIMUM TO 18 INCHES MAXIMUM FROM THE SIDE WALL OR
 PARTITION PER FBC ACC 604.2
 *****2) CLEARANCE AROUND A WATER CLOSET SHALL BE 60
 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES DEEP MINIMUM FOR WALL HUNG WATER
 CLOSETS AND 59 INCHES DEEP MINIMUM FOR FLOOR MOUNTED
 WATER CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL
 PER FBC ACC 604.3.1 AND 604.8.1.1
 *****3) THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG
 MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM THE
 REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR
 WALL PER FBC ACC 604.5.1
 *****4) THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES
 MINIMUM ON THE OTHER SIDE PER FBC ACC 604.5.2
 *****5) FLUSH CONTROLS SHALL BE HAND OPERATED OR
 AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY
 WITH 309. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN
 SIDE OF THE WATER CLOSET PER FBC ACC 604.6
 *****6) PER FBC ACC 604.8, TOILET PAPER DISPENSERS
 SHALL COMPLY WITH 309.4 AND SHALL BE 7 INCHES MINIMUM
 AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET
 MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET
 OF THE DISPENSER SHALL BE 15 INCHES MINIMUM AND 48
 INCHES MAXIMUM ABOVE THE FINISH FLOOR AND SHALL NOT BE
 LOCATED BEHIND GRAB BARS.
 *****7) THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE
 FINISH FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19
 INCHES (485 MM) MAXIMUM MEASURED TO THE TOP OF THE
 SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED
 POSITION PER FBC ACC 604.4.
 *****8) PER FBC ACC 609.4, GRAB BARS SHALL BE INSTALLED
 IN A HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36
 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE
 TOP (NOT THE CENTER) OF THE GRIPPING SURFACE.
 *****9) LAVATORIES AND SINKS SHALL BE INSTALLED WITH
 THE FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE
 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER
 FBC ACC 606.3, ADDITIONALLY SHOW TOE AND KNEE CLEARANCE
 AS REQUIRED BY FBC ACC 306.2 AND 306.3
 *****10) PER FBC 606.5 EXPOSED PIPES AND SURFACES.
 WATER SUPPLY & DRAINPIPES UNDER LAVATORIES AND SINKS
 SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT
 AGAINST CONTACT.
 *****11) UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE
 COMPLYING WITH 305 POSITIONED FOR A FORWARD APPROACH
 AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED PER FBC ACC 602.2.
 *****12) MIRRORS LOCATED ABOVE LAVATORIES OR
 COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF
 THE REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE
 FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE
 LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE
 BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES (890
 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC
 ACC 603.3.
 TO BE CLEAR, PLEASE CLARIFY ON PLANS THAT DIMENSION IS
 TO THE REFLECTING SURFACE OF THE MIRROR.
 *****13) SHOW TURNING SPACE COMPLYING WITH FBC ACC
 304.3.1 OR 304.3.2.
 *****14) PER FBC 606.5 EXPOSED PIPES AND SURFACES.
 WATER SUPPLY & DRAINPIPES UNDER LAVATORIES AND SINKS
 SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT
 AGAINST CONTACT.
 AS INDICATED IN FBC ACC 202.4.1, UPGRADE AS REQUIRED.
 ***B) PLEASE NOTE THE DRINKING FOUNTAIN ON PLAN SHEET
 A-01, P-01 AND THE REQUIREMENTS OF FBC ACC 211.1,
 211.2; WHERE DRINKING FOUNTAINS ARE PROVIDED, NO FEWER
 THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. ONE
 DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH 602.6
 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.7. PER
 WPB FBC 107.2.1, AN ELEVATION AND PLAN DETAIL OF THE
 UPGRADED FIXTURE(S) IS REQUIRED.
 AS INDICATED IN FBC ACC 202.4.1, UPGRADE AS REQUIRED.
 ***C) PER WPB FBC 107.2.1, PROVIDE ELEVATION AND PLAN
 DETAIL FOR WASHER(S) AND DRYER(S) SHOWING COMPLIANCE
 WITH FBC ACC 214 AND 611. TOP LOADING MACHINES SHALL
 HAVE THE DOOR TO THE LAUNDRY COMPARTMENT LOCATED 36
 INCHES MAXIMUM ABOVE THE FINISH FLOOR. FRONT LOADING
 MACHINES SHALL HAVE THE BOTTOM OF THE OPENING TO THE
 LAUNDRY COMPARTMENT LOCATED 15 INCHES MINIMUM AND 36
 INCHES MAXIMUM ABOVE THE FINISH FLOOR.
 AS INDICATED IN FBC ACC 202.4.1, UPGRADE AS REQUIRED.
 ***D) COST OF SUGGESTED UPGRADES IN EXCESS OF 20% OF
 THE COST OF THE ALTERATION TO THE PRIMARY FUNCTION AREA
 SHALL BE DEEMED DISPROPORTIONATE.
  
 2. SECOND REQUEST: WHERE SINKS ARE PROVIDED, AT LEAST 5
 PERCENT, BUT NO FEWER THAN ONE, OF EACH TYPE PROVIDED
 IN EACH ACCESSIBLE ROOM OR SPACE SHALL COMPLY WITH 606
 PER FBC ACC 212.3. PER WPB FBC 107.2.1, IDENTIFY
 ACCESSIBLE DORMITORY UNIT(S) AND PROVIDE ELEVATION AND
 PLAN DETAILS FOR NEW SINK SHOWING COMPLIANCE.
  
 3. SECOND REQUEST: PER FBC ACC 213.2, WHERE BATHING
 ROOMS ARE PROVIDED, EACH BATHING ROOM SHALL COMPLY WITH
 603. PER WPB FBC 107.2.1, IDENTIFY ACCESSIBLE DORMITORY
 UNIT(S) AND PROVIDE ELEVATION AND PLAN DETAILS FOR NEW
 BATHING ROOM(S) SHOWING COMPLIANCE WITH FBC ACC 603.
 NEW COMMENT: SEE FBC ACC 809.4 FOR ADDED CLARIFICATION
 WHICH CLEARLY INDICATES REQUIREMENTS IN RESIDENTIAL
 DWELLING UNIT(S)
 213.3.2WATER CLOSETS.
 WHERE WATER CLOSETS ARE PROVIDED, AT LEAST ONE SHALL
 COMPLY WITH 604.
 213.3.4LAVATORIES.
 WHERE LAVATORIES ARE PROVIDED, AT LEAST ONE SHALL
 COMPLY WITH 606 AND SHALL NOT BE LOCATED IN A TOILET
 COMPARTMENT.
 213.3.5MIRRORS.
 WHERE MIRRORS ARE PROVIDED, AT LEAST ONE SHALL COMPLY
 WITH 603.3.
 213.3.6BATHING FACILITIES.
 WHERE BATHTUBS OR SHOWERS ARE PROVIDED, AT LEAST ONE
 BATHTUB COMPLYING WITH 607 OR AT LEAST ONE SHOWER
 COMPLYING WITH 608 SHALL BE PROVIDED.
  
 4. SECOND REQUEST: PLAN SHEET A-0/APPLICABLE CODES: PER
 WPB FBC 107.2.1, PLEASE ADD 2020 FLORIDA PLUMBING CODE
 7TH EDITION AND 2020 FLORIDA MECHANICAL CODE 7TH
 EDITION TO THE LIST OF APPLICABLE CODES.
  
 5. SECOND REQUEST: PLAN SHEET A-0/APPLICABLE CODES: PER
 FBC 310.4, THE OCCUPANCY FOR THIS FACILITY IS R-2
 RESIDENTIAL.
  
 6. SECOND REQUEST: PLAN SHEET A-01, A-02/CONSTRUCTION
 NOTE 4: PER WPB FBC 107.2.1, 107.3.5.1.3 AND 107.3.5.3,
 PLUMBING FIXTURE SPACING SHALL COMPLY WITH FLORIDA
 PLUMBING CODE 2020 7TH EDITION, NOT THE FLORIDA
 RESIDENTIAL CODE 2020 7TH EDITION
 ADDITIONALLY, AS NOTED IN COMMENT 3, COMPLY WITH FBC
 ACC 213.2 AND 809.4.
  
 7. SECOND REQUEST: PER WPB FBC 107.2.1, PLEASE IDENTIFY
 AND TAG ALL NEW PLUMBING FIXTURES ON PLUMBING FLOOR
 PLANS AND ISOMETRICS. TAG AND ID SHALL MATCH PLUMBING
 FIXTURE SCHEDULE ON P-05.
  
 8. SECOND REQUEST:P-05/PLUMBING NOTES: PER WPB FBC
 107.2.1, REVISE THE FOLLOWING
 ***A) NOTES 6 & 7 "PVC DRAINAGE (DWV) SCHEDULE 40 PIPE
 AND FITTINGS"
 ***B) NOTE 13 "COPPER WATER PIPING JOINTS TO BE MADE
 WITH LEAD FREE SOLDER"
 ***C) NOTE 14 "VALVES TO BE LEAD FREE"
 ***D) NOTE 16 "HOT WATER PIPING TO BE INSULATED IN
 ACCORDANCE WITH FBC EC C404.4 (A-E) AND TABLE
 C403.2.10"
 PROVIDE A SPEC THAT COMPLIES
 ***E) NOTE 19 "IN ACCORDANCE WITH FBC PL 604.9, PROVIDE
 WATER HAMMER ARRESTORS AT EACH FIXTURE GROUP CONFORMING
 TO ASSE 1010"
 ***F) ADD NOTE "ALL COMPONENTS IN THE DOMESTIC WATER
 SYSTEM SHALL BE LEAD FREE IN ACCORDANCE WITH FBC PL
 605.2 AND 605.2.1"
  
 9. SECOND REQUEST: P-05/PLUMBING FIXTURE SCHEDULE: PER
 WPB FBC 107.2.1, PROVIDE SPEC AND ID/TAG FOR SHOWER.
 INCLUDE DRAIN, SHOWER CONTROL VALVE AND TRIM. PER FBC
 PL 412.3, INDIVIDUAL SHOWER AND TUB-SHOWER COMBINATION
 VALVES SHALL BE BALANCED-PRESSURE, THERMOSTATIC OR
 COMBINATION BALANCED-PRESSURE/THERMOSTATIC VALVES THAT
 CONFORM TO THE REQUIREMENTS OF ASSE 1016/ASME
 A112.1016/CSA B125.16 OR ASME A112.18.1/CSA B125.1 AND
 SHALL BE INSTALLED AT THE POINT OF USE.
  
 10. SECOND REQUEST: PER WPB FBC 107.2.1, PROVIDE A
 CROSS-SECTION SHOWER WALL/FLOOR/DRAIN AND THRESHOLD
 DETAIL
 ***A) DETAIL SHALL INCLUDE ALL COMPONENTS OF FBC PL
 421.5.2 AS FOLLOWS
 LINERS SHALL TURN UP ON ALL SIDES NOT LESS THAN 2
 INCHES ABOVE THE FINISHED THRESHOLD LEVEL
 LINERS SHALL BE RECESSED AND FASTENED TO AN APPROVED
 BACKING
 LINERS SHALL NOT BE NAILED OR PERFORATED AT ANY POINT
 LESS THAN 1 INCH ABOVE THE FINISHED THRESHOLD
 LINERS SHALL BE PITCHED ONE-FOURTH UNIT VERTICAL IN 12
 UNITS HORIZONTAL (2-PERCENT SLOPE) AND SHALL BE SLOPED
 TOWARD THE FIXTURE DRAIN
 LINERS SHALL BE SECURELY FASTENED TO THE WASTE OUTLET
 AT THE SEEPAGE ENTRANCE, MAKING A WATER-TIGHT JOINT
 BETWEEN THE LINER AND THE OUTLET
 FLOORS OR RECEPTORS UNDER SHOWER COMPARTMENTS SHALL BE
 LAID ON, AND SUPPORTED BY, A SMOOTH AND STRUCTURALLY
 SOUND BASE.
 ***B) LINER MATERIAL (SPECIFY LINER MATERIAL COMPLYING
 WITH ONE OF THE FOLLOWING FBC PL SECTIONS-421.5.2.1,
 421.5.2.2, 421.5.2.3, 421.5.2.4, 421.5.2.5 OR
 421.5.2.6.) NOTE THAT FBC PL 421.5.2.1 PLASTICIZED
 POLYVINYL CHLORIDE (PVC) SHEETS MEETING THE
 REQUIREMENTS OF ASTM D4551 IS A COMMON LINER USED.
 ***C) FBC PL 421.4.1: WALLS IN SHOWER COMPARTMENTS
 SHALL BE CONSTRUCTED OF SMOOTH, CORROSION-RESISTANT AND
 NONABSORBENT WATERPROOF MATERIALS NOT LESS THAN 6 FEET
 ABOVE THE ROOM FLOOR LEVEL, AND NOT LESS THAN 70 INCHES
 ABOVE THE DRAIN OF THE SHOWER.
  
 11. SECOND REQUEST: PER WPB FBC 107.2.1, PROVIDE PIPE
 HANGER DETAIL WITH A NOTE STATING, "HORIZONTAL PIPE
 SHALL BE SUPPORTED IN ACCORDANCE WITH FBC PL TABLE
 308.5."
  
 12. SECOND REQUEST: PER WPB FBC 107.2.1, PROVIDE A SLAB
 REPAIR DETAIL ON THE PLANS. SHOW THE WIDTH OF THE
 REPAIR, THE MINIMUM THICKNESS AND PSI OF THE CONCRETE
 TO BE REPLACED. SHOW SIZE, LENGTH, SPACING (ON CENTER),
 MINIMUM EMBEDMENT AND ANCHORING/ADHESIVE MATERIAL FOR
 DOWELS. THE REPAIR SHALL ALSO INCLUDE TERMITE TREATMENT
 OF THE SOIL AS WELL AS THE REQUIRED VAPOR BARRIER OVER
 WELL COMPACTED SOIL. A COPY OF THE TERMITE CERTIFICATE
 SHALL BE ONSITE FOR FINAL INSPECTION.
  
 13. SECOND REQUEST: PER WPB FBC 107.2.1, PROVIDE
 APPLICABLE RATED WALL/FLOOR DETAILS FOR PLUMBING
 PENETRATIONS COMPLYING WITH THE REQUIREMENTS OF FBC
 CHAPTER 7.
  
 14. SECOND REQUEST: PER WPB FBC 107.2.1, TO SHOW
 COMPLIANCE WITH FBC PL 704.1, PROVIDE NOTE STATING
 "HORIZONTAL DRAINAGE PIPING LESS THAN 3 INCH DIAMETER
 SHALL HAVE A MINIMUM SLOPE OF 1/4 INCH PER FOOT. 3 INCH
 TO 6 INCH DIAMETER SHALL HAVE A MINIMUM SLOPE OF 1/8
 INCH PER FOOT".
  
 15. SECOND REQUEST: P-07/RISER DIAGRAM: PER FBC PL
 606.1(6) PROVIDE A FULL OPEN VALVE TO EACH HOT AND COLD
 WATER SUPPLY TO EACH NEW UNIT. THE LAVATORIES SHALL BE
 INSTALLED DOWNSTREAM OF SAID VALVES.
  
 16. SECOND REQUEST: P-07/RISER DIAGRAM: PER WPB FBC
 107.2.1, IDENTIFY THE WATER HAMMER ARRESTORS (TAG WHA)
 ON THE WATER RISER DIAGRAMS.
  
 17. SECOND REQUEST: PER FBC PL 604.1, THE DESIGN OF THE
 WATER DISTRIBUTION SYSTEM SHALL CONFORM TO ACCEPTED
 ENGINEERING PRACTICE. METHODS UTILIZED TO DETERMINE
 PIPE SIZES SHALL BE APPROVED. PER WPB FBC 107.2.1 AND
 107.3.5.1.3, PROVIDE CALCULATIONS FOR SIZING OF WATER
 DISTRIBUTION. FBC PL APPENDIX E, SIZING OF WATER PIPING
 SYSTEM IS AN APPROVED METHOD.
  
 18. SECOND REQUEST: P-01/EXISTING FLOOR DRAIN: PER WPB
 FBC 107.2.1, CONFIRM THAT THE EXISTING FLOOR DRAIN IN
 THE NEW BATHROOM HAS A TRAP PRIMER AND INDICATE ON THE
 PLAN HOW IT IS PROVIDED. IF NOT, THEN PER FBC PL
 1002.4.1, PROVIDE TRAP SEAL PROTECTION IN ACCORDANCE
 WITH ONE OF THE METHODS IN SECTIONS 1002.4.1.1 THROUGH
 1002.4.1.4. ADDITIONALLY, PROVIDE A SCHEMATIC DETAIL.
  
 19. SECOND REQUEST: P-05/SANITARY RISER DIAGRAM: PER
 FBC PL 909.1, EACH FIXTURE TRAP SHALL HAVE A PROTECTING
 VENT LOCATED SO THAT THE SLOPE AND THE DEVELOPED LENGTH
 IN THE FIXTURE DRAIN FROM THE TRAP WEIR TO THE VENT
 FITTING ARE WITHIN THE REQUIREMENTS SET FORTH IN TABLE
 909.1. THE WATER CLOSETS AND SHOWERS ON THE FIRST,
 SECOND AND THIRD FLOORS DO NOT COMPLY. PER WPB FBC
 107.2.1, VENT EACH OF THE WATER CLOSETS AND SHOWERS IN
 ACCORDANCE WITH ONE OF THE PRESCRIBED METHODS IN
 CHAPTER 9.
  
 20. SECOND REQUEST: P-05/SANITARY RISER SERVICING ONLY
 FLOORS 2 THROUGH 4: PER FBC PL 912.1.1, THE SHOWER
 DRAIN ON THE FOURTH FLOOR SHALL CONNECT TO THE STACK AT
 OR ABOVE THE WATER CLOSET ELEVATION. PLEASE NOTE ALSO
 THAT ANY TIME A WATER CLOSET AND OTHER BATHROOM GROUP
 FIXTURES ARE CONNECTED TO ANY VERTICAL WET VENT, THE
 OTHER FIXTURES SHALL CONNECT AT OR ABOVE THE ELEVATION
 WITH THE WATER CLOSET AS NOTED IN 912.1.1.
  
 21. SECOND REQUEST: P-05/SANITARY RISER GROUND FLOOR:
 THE BRANCH BETWEEN THE FLOOR DRAIN AND THE CONNECTION
 RECEIVING THE BATHROOM GROUPS DISCHARGE IS INCORRECTLY
 TAGGED VTR. PER WPB FBC 107.2.1, PLEASE CORRECT.
  
 22. SECOND REQUEST: P-05/SANITARY RISER WITH GROUND
 FLOOR BATHROOM: WATER CLOSET FIXTURE DRAIN SHALL BE 3
 INCH MINIMUM SIZE PER FBC PL 704.2, TABLE 709.1(D) AND
 710.1(2)-A
  
 23. SECOND REQUEST: PER WPB FBC 107.2.1, ID/TAG THE
 SANITARY AND WATER RISERS ON BOTH RISER DIAGRAMS AND
 FLOOR PLANS. ID/TAG SHALL MATCH ON THE CORRESPONDING
 DRAWINGS. SEE COMMENT 7 REGARDING THE FIXTURE SCHEDULE.
  
 24. SECOND REQUEST: P-05/SANITARY RISER: BATHROOM
 GROUPS PER FBC PL TABLE 710.1, HAVE A FIXTURE UNIT
 VALUE OF 5 PER GROUP. WATER CLOSETS, PRIVATE, 1.6 GPF
 OR LESS HAVE A VALUE OF 3. SHOWERS HAVE A VALUE OF 2.
 PER WPB FBC 107.2.1, PLEASE REVIEW YOUR CALCULATIONS
 AND MODIFY AS IS APPROPRIATE.
  
 25. PER WPB FBC 107.2.1, PLEASE INDICATE ON THE PLANS
 IF THE HOT WATER SYSTEM IS RECIRCULATED OR HEAT TRACED;
 PROVIDE THE TEMPERATURE OF THE HOT WATER.
 TO BE CLEAR, PER FBC PL 607.2, THE DEVELOPED LENGTH OF
 HOT OR TEMPERED WATER PIPING FROM THE SOURCE OF HOT
 WATER TO THE FIXTURE SHALL NOT EXCEED 50 FEET.
 RECIRCULATING SYSTEMS AND HEAT TRACED SYSTEMS ARE
 CONSIDERED TO BE SOURCES OF HOT OR TEMPERED WATER.
 PLEASE SHOW THAT THE HOT OR TEMPERED WATER FROM THE
 SOURCE TO THE FIXTURES DOES NOT EXCEED 50 FEET OR
 PROVIDE MEANS TO COMPLY.
  
 26.NEW COMMENT: FBC ACC 611, PROVIDE THE MEASUREMENTS
 WITHIN THE LAUNDRY ROOMS TO SHOW COMPLIANCE WITH
 ACCESSIBLE REQUIREMENTS INCLUDING CLEAR FLOOR, WHEEL
 CHAIR APPROACH AND REACH REQUIREMENTS.
  
 27. NEW COMMENT: IT APPEARS THAT THE PLUMBING FIXTURE
 SCHEDULE ON P-05 IS FROM THE ORIGINAL CONSTRUCTION AND
 IS NOT APPLICABLE TO THE NEW WORK; SOME PRODUCTS ARE
 DISCONTINUED. PER WPB FBC 107.2.1, PROVIDE AN
 APPLICABLE FIXTURE SCHEDULE; TAG TO MATCH DRAWINGS. SEE
 COMMENT 7 AND 23.
  
 28. NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE CORRECT
 OCCUPANCY (PER FBC 310.4, R-2) AND THE OCCUPANT LOAD
 FOR THE BUILDING.
  
 29. NEW COMMENT: PER WPB FBC 107.2.1, PROVIDE A
 PLUMBING FIXTURE SCHEDULE FOR THE BUILDING SHOWING THE
 REQUIRED PLUMBING FIXTURES (SEE FBC PL TABLE 403.1) AND
 THE PROVIDED PLUMBING FIXTURES. THIS DOES NOT APPLY TO
 THE DWELLING UNITS. PLEASE NOTE THAT THE REQUIRED
 DRINKING FOUNTAIN QUANTITY FOR R-2 IS 1 PER 100
 PERSONS. ADDITIONALLY, IN ACCORDANCE WITH FBC PL 410.3
 AND FBC ACC 211.2, A BI-LEVEL DRINKING FOUNTAIN
 CONSTITUTES 2 DRINKING FOUNTAINS.
  
 30. NEW COMMENT: IT APPEARS THAT THE PLUMBING FIXTURE
 SCHEDULE ON P-05 IS FROM THE ORIGINAL CONSTRUCTION AND
 IS NOT APPLICABLE TO THE NEW WORK; SOME PRODUCTS ARE
 DISCONTINUED. PER WPB FBC 107.2.1, PROVIDE AN
 APPLICABLE FIXTURE SCHEDULE; TAG TO MATCH DRAWINGS. SEE
 COMMENT 7 AND 23.
  
 31. NEW COMMENT: PLAN SHEET A-0/APPLICABLE CODES: PER
 WPB FBC 107.2.1, PLEASE ADD 2020 FLORIDA BUILDING CODE,
 EXISTING BUILDING, 7TH EDITION AND PROVIDE THE
 APPLICABLE LEVEL OF OPERATION.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 PLEASE PROVIDE A DETAILED RESPONSE LETTER ADDRESING
 EACH ITEM/COMMENT.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 PLUMBING INSPECTOR BN2148
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-06-07 Cont ID  
Sent By jesmith Date 2022-06-07 Time 15:23 Rev Time 0.00
Received By jesmith Date 2022-06-02 Time 16:11 Sent To  
Notes
2022-06-07 15:19:08CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22051265 300 PEMBROKE PL
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1. PLEASE NOTE FBC ACC 202.4.1, DISPROPORTIONATE COST:
 ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL TO THE ALTERED AREA WILL BE DEEMED
 DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE
 COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE
 PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS
 EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF
 TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING
 AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE
 ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING
 RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS,
 ENLARGING TOILET STALLS, INSULATING PIPES, OR
 INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS
 ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH
 AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT,
 INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT
 TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING
 AN INACCESSIBLE DRINKING FOUNTAIN.
 ***A) PER WPB FBC 107.2.1, PROVIDE DIMENSIONED PLAN AND
 ELEVATION VIEW OF EXISTING MEN AND WOMEN TOILET ROOMS
 SHOWING COMPLIANCE WITH FBC ACC CHAPTERS 2, 3 AND 6 AS
 FOLLOWS:
 *****1) THE WATER CLOSET SHALL BE POSITIONED WITH A
 WALL OR PARTITION TO THE REAR AND TO ONE SIDE. THE
 CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES
 MINIMUM TO 18 INCHES MAXIMUM FROM THE SIDE WALL OR
 PARTITION PER FBC ACC 604.2
 *****2) CLEARANCE AROUND A WATER CLOSET SHALL BE 60
 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES DEEP MINIMUM FOR WALL HUNG WATER
 CLOSETS AND 59 INCHES DEEP MINIMUM FOR FLOOR MOUNTED
 WATER CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL
 PER FBC ACC 604.3.1 AND 604.8.1.1
 *****3) THE SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG
 MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM THE
 REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR
 WALL PER FBC ACC 604.5.1
 *****4) THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES
 MINIMUM ON THE OTHER SIDE PER FBC ACC 604.5.2
 *****5) FLUSH CONTROLS SHALL BE HAND OPERATED OR
 AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY
 WITH 309. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN
 SIDE OF THE WATER CLOSET PER FBC ACC 604.6
 *****6) PER FBC ACC 604.8, TOILET PAPER DISPENSERS
 SHALL COMPLY WITH 309.4 AND SHALL BE 7 INCHES MINIMUM
 AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET
 MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET
 OF THE DISPENSER SHALL BE 15 INCHES MINIMUM AND 48
 INCHES MAXIMUM ABOVE THE FINISH FLOOR AND SHALL NOT BE
 LOCATED BEHIND GRAB BARS.
 *****7) THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE
 FINISH FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19
 INCHES (485 MM) MAXIMUM MEASURED TO THE TOP OF THE
 SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED
 POSITION PER FBC ACC 604.4.
 *****8) PER FBC ACC 609.4, GRAB BARS SHALL BE INSTALLED
 IN A HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36
 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE
 TOP (NOT THE CENTER) OF THE GRIPPING SURFACE.
 *****9) LAVATORIES AND SINKS SHALL BE INSTALLED WITH
 THE FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE
 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER
 FBC ACC 606.3, ADDITIONALLY SHOW TOE AND KNEE CLEARANCE
 AS REQUIRED BY FBC ACC 306.2 AND 306.3
 *****10) PER FBC 606.5 EXPOSED PIPES AND SURFACES.
 WATER SUPPLY & DRAINPIPES UNDER LAVATORIES AND SINKS
 SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT
 AGAINST CONTACT.
 *****11) UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE
 COMPLYING WITH 305 POSITIONED FOR A FORWARD APPROACH
 AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED PER FBC ACC 602.2.
 *****12) MIRRORS LOCATED ABOVE LAVATORIES OR
 COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF
 THE REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE
 FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE
 LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE
 BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES (890
 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND PER FBC
 ACC 603.3.
 TO BE CLEAR, PLEASE CLARIFY ON PLANS THAT DIMENSION IS
 TO THE REFLECTING SURFACE OF THE MIRROR.
 *****13) SHOW TURNING SPACE COMPLYING WITH FBC ACC
 304.3.1 OR 304.3.2.
 *****14) PER FBC 606.5 EXPOSED PIPES AND SURFACES.
 WATER SUPPLY & DRAINPIPES UNDER LAVATORIES AND SINKS
 SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT
 AGAINST CONTACT.
 AS INDICATED IN FBC ACC 202.4.1, UPGRADE AS REQUIRED.
 ***B) PLEASE NOTE THE DRINKING FOUNTAIN ON PLAN SHEET
 A-01, P-01 AND THE REQUIREMENTS OF FBC ACC 211.1,
 211.2; WHERE DRINKING FOUNTAINS ARE PROVIDED, NO FEWER
 THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. ONE
 DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH 602.6
 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.7. PER
 WPB FBC 107.2.1, AN ELEVATION AND PLAN DETAIL OF THE
 UPGRADED FIXTURE(S) IS REQUIRED.
 AS INDICATED IN FBC ACC 202.4.1, UPGRADE AS REQUIRED.
 ***C) PER WPB FBC 107.2.1, PROVIDE ELEVATION AND PLAN
 DETAIL FOR WASHER(S) AND DRYER(S) SHOWING COMPLIANCE
 WITH FBC ACC 214 AND 611. TOP LOADING MACHINES SHALL
 HAVE THE DOOR TO THE LAUNDRY COMPARTMENT LOCATED 36
 INCHES MAXIMUM ABOVE THE FINISH FLOOR. FRONT LOADING
 MACHINES SHALL HAVE THE BOTTOM OF THE OPENING TO THE
 LAUNDRY COMPARTMENT LOCATED 15 INCHES MINIMUM AND 36
 INCHES MAXIMUM ABOVE THE FINISH FLOOR.
 AS INDICATED IN FBC ACC 202.4.1, UPGRADE AS REQUIRED.
 ***D) COST OF SUGGESTED UPGRADES IN EXCESS OF 20% OF
 THE COST OF THE ALTERATION TO THE PRIMARY FUNCTION AREA
 SHALL BE DEEMED DISPROPORTIONATE.
  
 2. WHERE SINKS ARE PROVIDED, AT LEAST 5 PERCENT, BUT NO
 FEWER THAN ONE, OF EACH TYPE PROVIDED IN EACH
 ACCESSIBLE ROOM OR SPACE SHALL COMPLY WITH 606 PER FBC
 ACC 212.3. PER WPB FBC 107.2.1, IDENTIFY ACCESSIBLE
 DORMITORY UNIT(S) AND PROVIDE ELEVATION AND PLAN
 DETAILS FOR NEW SINK SHOWING COMPLIANCE.
  
 3. PER FBC ACC 213.2, WHERE BATHING ROOMS ARE PROVIDED,
 EACH BATHING ROOM SHALL COMPLY WITH 603. PER WPB FBC
 107.2.1, IDENTIFY ACCESSIBLE DORMITORY UNIT(S) AND
 PROVIDE ELEVATION AND PLAN DETAILS FOR NEW BATHING
 ROOM(S) SHOWING COMPLIANCE WITH FBC ACC 603.
 EXCEPTIONS:
 ***1) IN ALTERATIONS WHERE IT IS TECHNICALLY INFEASIBLE
 TO COMPLY WITH 603, ALTERING EXISTING TOILET OR BATHING
 ROOMS SHALL NOT BE REQUIRED WHERE A SINGLE UNISEX
 TOILET ROOM OR BATHING ROOM COMPLYING WITH 213.2.1 IS
 PROVIDED AND LOCATED IN THE SAME AREA AND ON THE SAME
 FLOOR AS EXISTING IN ACCESSIBLE TOILET OR BATHING
 ROOMS.
 ***2) WHERE EXCEPTIONS FOR ALTERATIONS TO QUALIFIED
 HISTORIC BUILDINGS OR FACILITIES ARE PERMITTED BY
 202.5, NO FEWER THAN ONE TOILET ROOM FOR EACH SEX
 COMPLYING WITH 603 OR ONE UNISEX TOILET ROOM COMPLYING
 WITH 213.2.1 SHALL BE PROVIDED.
 ***3) WHERE MULTIPLE SINGLE USER PORTABLE TOILET OR
 BATHING UNITS ARE CLUSTERED AT A SINGLE LOCATION, NO
 MORE THAN 5 PERCENT OF THE TOILET UNITS AND BATHING
 UNITS AT EACH CLUSTER SHALL BE REQUIRED TO COMPLY WITH
 603. PORTABLE TOILET UNITS AND BATHING UNITS COMPLYING
 WITH 603 SHALL BE IDENTIFIED BY THE INTERNATIONAL
 SYMBOL OF ACCESSIBILITY COMPLYING WITH 703.7.2.1.
 ***4) WHERE MULTIPLE SINGLE USER TOILET ROOMS ARE
 CLUSTERED AT A SINGLE LOCATION, NO MORE THAN 50 PERCENT
 OF THE SINGLE USER TOILET ROOMS FOR EACH USE AT EACH
 CLUSTER SHALL BE REQUIRED TO COMPLY WITH 603.
  
 4. PLAN SHEET A-0/APPLICABLE CODES: PER WPB FBC
 107.2.1, PLEASE ADD 2020 FLORIDA PLUMBING CODE 7TH
 EDITION AND 2020 FLORIDA MECHANICAL CODE 7TH EDITION TO
 THE LIST OF APPLICABLE CODES.
  
 5. PLAN SHEET A-0/APPLICABLE CODES: PER FBC 310.4, THE
 OCCUPANCY FOR THIS FACILITY IS R-2 RESIDENTIAL.
  
 6. PLAN SHEET A-01, A-02/CONSTRUCTION NOTE 4: PER WPB
 FBC 107.2.1, 107.3.5.1.3 AND 107.3.5.3, PLUMBING
 FIXTURE SPACING SHALL COMPLY WITH FLORIDA PLUMBING CODE
 2020 7TH EDITION, NOT THE FLORIDA RESIDENTIAL CODE 2020
 7TH EDITION
  
 7. PER WPB FBC 107.2.1, PLEASE IDENTIFY AND TAG ALL NEW
 PLUMBING FIXTURES ON PLUMBING FLOOR PLANS AND
 ISOMETRICS. TAG AND ID SHALL MATCH PLUMBING FIXTURE
 SCHEDULE ON P-05.
  
 8. P-05/PLUMBING NOTES: PER WPB FBC 107.2.1, REVISE THE
 FOLLOWING
 ***A) NOTES 6 & 7 "PVC DRAINAGE (DWV) SCHEDULE 40 PIPE
 AND FITTINGS"
 ***B) NOTE 13 "COPPER WATER PIPING JOINTS TO BE MADE
 WITH LEAD FREE SOLDER"
 ***C) NOTE 14 "VALVES TO BE LEAD FREE"
 ***D) NOTE 16 "HOT WATER PIPING TO BE INSULATED IN
 ACCORDANCE WITH FBC EC C404.4 (A-E) AND TABLE
 C403.2.10"
 PROVIDE A SPEC THAT COMPLIES
 ***E) NOTE 19 "IN ACCORDANCE WITH FBC PL 604.9, PROVIDE
 WATER HAMMER ARRESTORS AT EACH FIXTURE GROUP CONFORMING
 TO ASSE 1010"
 ***F) ADD NOTE "ALL COMPONENTS IN THE DOMESTIC WATER
 SYSTEM SHALL BE LEAD FREE IN ACCORDANCE WITH FBC PL
 605.2 AND 605.2.1"
  
 8. P-05/PLUMBING FIXTURE SCHEDULE: PER WPB FBC 107.2.1,
 PROVIDE SPEC AND ID/TAG FOR SHOWER. INCLUDE DRAIN,
 SHOWER CONTROL VALVE AND TRIM. PER FBC PL 412.3,
 INDIVIDUAL SHOWER AND TUB-SHOWER COMBINATION VALVES
 SHALL BE BALANCED-PRESSURE, THERMOSTATIC OR COMBINATION
 BALANCED-PRESSURE/THERMOSTATIC VALVES THAT CONFORM TO
 THE REQUIREMENTS OF ASSE 1016/ASME A112.1016/CSA
 B125.16 OR ASME A112.18.1/CSA B125.1 AND SHALL BE
 INSTALLED AT THE POINT OF USE.
  
 9. PER WPB FBC 107.2.1, PROVIDE A CROSS-SECTION SHOWER
 WALL/FLOOR/DRAIN AND THRESHOLD DETAIL
 ***A) DETAIL SHALL INCLUDE ALL COMPONENTS OF FBC PL
 421.5.2 AS FOLLOWS
 LINERS SHALL TURN UP ON ALL SIDES NOT LESS THAN 2
 INCHES ABOVE THE FINISHED THRESHOLD LEVEL
 LINERS SHALL BE RECESSED AND FASTENED TO AN APPROVED
 BACKING
 LINERS SHALL NOT BE NAILED OR PERFORATED AT ANY POINT
 LESS THAN 1 INCH ABOVE THE FINISHED THRESHOLD
 LINERS SHALL BE PITCHED ONE-FOURTH UNIT VERTICAL IN 12
 UNITS HORIZONTAL (2-PERCENT SLOPE) AND SHALL BE SLOPED
 TOWARD THE FIXTURE DRAIN
 LINERS SHALL BE SECURELY FASTENED TO THE WASTE OUTLET
 AT THE SEEPAGE ENTRANCE, MAKING A WATER-TIGHT JOINT
 BETWEEN THE LINER AND THE OUTLET
 FLOORS OR RECEPTORS UNDER SHOWER COMPARTMENTS SHALL BE
 LAID ON, AND SUPPORTED BY, A SMOOTH AND STRUCTURALLY
 SOUND BASE.
 ***B) LINER MATERIAL (SPECIFY LINER MATERIAL COMPLYING
 WITH ONE OF THE FOLLOWING FBC PL SECTIONS-421.5.2.1,
 421.5.2.2, 421.5.2.3, 421.5.2.4, 421.5.2.5 OR
 421.5.2.6.) NOTE THAT FBC PL 421.5.2.1 PLASTICIZED
 POLYVINYL CHLORIDE (PVC) SHEETS MEETING THE
 REQUIREMENTS OF ASTM D4551 IS A COMMON LINER USED.
 ***C) FBC PL 421.4.1: WALLS IN SHOWER COMPARTMENTS
 SHALL BE CONSTRUCTED OF SMOOTH, CORROSION-RESISTANT AND
 NONABSORBENT WATERPROOF MATERIALS NOT LESS THAN 6 FEET
 ABOVE THE ROOM FLOOR LEVEL, AND NOT LESS THAN 70 INCHES
 ABOVE THE DRAIN OF THE SHOWER.
  
 10. PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL
 WITH A NOTE STATING, "HORIZONTAL PIPE SHALL BE
 SUPPORTED IN ACCORDANCE WITH FBC PL TABLE 308.5."
  
 11. PER WPB FBC 107.2.1, PROVIDE A SLAB REPAIR DETAIL
 ON THE PLANS. SHOW THE WIDTH OF THE REPAIR, THE MINIMUM
 THICKNESS AND PSI OF THE CONCRETE TO BE REPLACED. SHOW
 SIZE, LENGTH, SPACING (ON CENTER), MINIMUM EMBEDMENT
 AND ANCHORING/ADHESIVE MATERIAL FOR DOWELS. THE REPAIR
 SHALL ALSO INCLUDE TERMITE TREATMENT OF THE SOIL AS
 WELL AS THE REQUIRED VAPOR BARRIER OVER WELL COMPACTED
 SOIL. A COPY OF THE TERMITE CERTIFICATE SHALL BE ONSITE
 FOR FINAL INSPECTION.
  
 12. PER WPB FBC 107.2.1, PROVIDE APPLICABLE RATED
 WALL/FLOOR DETAILS FOR PLUMBING PENETRATIONS COMPLYING
 WITH THE REQUIREMENTS OF FBC CHAPTER 7.
  
 13. PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC PL
 704.1, PROVIDE NOTE STATING ?HORIZONTAL DRAINAGE PIPING
 LESS THAN 3 INCH DIAMETER SHALL HAVE A MINIMUM SLOPE OF
 1/4 INCH PER FOOT. 3 INCH TO 6 INCH DIAMETER SHALL HAVE
 A MINIMUM SLOPE OF 1/8 INCH PER FOOT.
  
 14. P-07/RISER DIAGRAM: PER FBC PL 606.1(6) PROVIDE A
 FULL OPEN VALVE TO EACH HOT AND COLD WATER SUPPLY TO
 EACH NEW UNIT. THE LAVATORIES SHALL BE INSTALLED
 DOWNSTREAM OF SAID VALVES.
  
 15. P-07/RISER DIAGRAM: PER WPB FBC 107.2.1, IDENTIFY
 THE WATER HAMMER ARRESTORS (WHA) ON THE WATER RISER
 DIAGRAMS.
  
 16. PER FBC PL 604.1, THE DESIGN OF THE WATER
 DISTRIBUTION SYSTEM SHALL CONFORM TO ACCEPTED
 ENGINEERING PRACTICE. METHODS UTILIZED TO DETERMINE
 PIPE SIZES SHALL BE APPROVED. PER WPB FBC 107.2.1 AND
 107.3.5.1.3, PROVIDE CALCULATIONS FOR SIZING OF WATER
 DISTRIBUTION. FBC PL APPENDIX E, SIZING OF WATER PIPING
 SYSTEM IS AN APPROVED METHOD.
  
 17. P-01/EXISTING FLOOR DRAIN: PER WPB FBC 107.2.1,
 CONFIRM THAT THE EXISTING FLOOR DRAIN IN THE NEW
 BATHROOM HAS A TRAP PRIMER AND INDICATE ON THE PLAN HOW
 IT IS PROVIDED. IF NOT, THEN PER FBC PL 1002.4.1,
 PROVIDE TRAP SEAL PROTECTION IN ACCORDANCE WITH ONE OF
 THE METHODS IN SECTIONS 1002.4.1.1 THROUGH 1002.4.1.4.
 ADDITIONALLY, PROVIDE A SCHEMATIC DETAIL.
  
 18. P-05/SANITARY RISER DIAGRAM: PER FBC PL 909.1, EACH
 FIXTURE TRAP SHALL HAVE A PROTECTING VENT LOCATED SO
 THAT THE SLOPE AND THE DEVELOPED LENGTH IN THE FIXTURE
 DRAIN FROM THE TRAP WEIR TO THE VENT FITTING ARE WITHIN
 THE REQUIREMENTS SET FORTH IN TABLE 909.1. THE WATER
 CLOSETS AND SHOWERS ON THE FIRST, SECOND AND THIRD
 FLOORS DO NOT COMPLY. PER WPB FBC 107.2.1, VENT EACH OF
 THE WATER CLOSETS AND SHOWERS IN ACCORDANCE WITH ONE OF
 THE PRESCRIBED METHODS IN CHAPTER 9. TYPICALLY, THE
 PROVISIONS OF FBC PL SECTION 912, WOULD BE A SUITABLE
 METHOD FOR THIS APPLICATION.
  
 19. P-05/SANITARY RISER SERVICING ONLY FLOORS TWO
 THROUGH 4: PER FBC PL 912.1.1, THE SHOWER DRAIN ON THE
 FOURTH FLOOR SHALL CONNECT TO THE STACK AT OR ABOVE THE
 WATER CLOSET ELEVATION. PLEASE NOTE ALSO THAT ANY TIME
 A WATER CLOSET AND OTHER BATHROOM GROUP FIXTURES ARE
 CONNECTED TO ANY VERTICAL WET VENT, THE OTHER FIXTURES
 SHALL CONNECT AT OR ABOVE THE ELEVATION WITH THE WATER
 CLOSET AS NOTED IN 912.1.1.
  
 20. P-05/SANITARY RISER GROUND FLOOR: THE BRANCH
 BETWEEN THE FLOOR DRAIN AND THE CONNECTION RECEIVING
 THE BATHROOM GROUPS DISCHARGE IS INCORRECTLY TAGGED
 VTR. PER WPB FBC 107.2.1, PLEASE CORRECT.
  
 21. P-05/SANITARY RISER WITH GROUND FLOOR BATHROOM:
 WATER CLOSET FIXTURE DRAIN SHALL BE 3 INCH MINIMUM SIZE
 PER FBC PL 704.2, TABLE 709.1(D) AND 710.1(2)-A
  
 22. PER WPB FBC 107.2.1, ID/TAG THE SANITARY AND WATER
 RISERS ON BOTH RISER DIAGRAMS AND FLOOR PLANS. ID/TAG
 SHALL MATCH ON THE CORRESPONDING DRAWINGS.
  
 23. P-05/SANITARY RISER: BATHROOM GROUPS PER FBC PL
 TABLE 710.1, HAVE A FIXTURE UNIT VALUE OF 5 PER GROUP.
 WATER CLOSETS, PRIVATE, 1.6 GPF OR LESS HAVE A VALUE OF
 3. SHOWERS HAVE A VALUE OF 2. PER WPB FBC 107.2.1,
 PLEASE REVIEW YOUR CALCULATIONS AND MODIFY AS IS
 APPROPRIATE.
  
 24. PER WPB FBC 107.2.1, PLEASE INDICATE ON THE PLANS
 IF THE HOT WATER SYSTEM IS RECIRCULATED OR HEAT TRACED;
 PROVIDE THE TEMPERATURE OF THE HOT WATER.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 PLUMBING INSPECTOR BN2148
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-08-30 Cont ID  
Sent By pvalenti Date 2022-08-30 Time 17:22 Rev Time 0.00
Received By pvalenti Date 2022-08-30 Time 16:20 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-08-25 Cont ID  
Sent By pvalenti Date 2022-08-25 Time 07:58 Rev Time 0.00
Received By pvalenti Date 2022-08-25 Time 07:58 Sent To  
Notes
2022-08-25 06:35:42MECHANICAL DIGITAL SIGNATURES APPROVED ME
2022-08-23 16:46:08PLUMBING PLANS HAVE VALID DIGITAL SIGNATURES. JS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-07-19 Cont ID  
Sent By medwards Date 2022-07-19 Time 10:32 Rev Time 0.00
Received By medwards Date 2022-07-19 Time 10:32 Sent To  
Notes
2022-07-19 15:45:39SIGNATURES FOR PLUMBING ARE VALID. JS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-06-03 Cont ID  
Sent By jleahy Date 2022-06-03 Time 16:15 Rev Time 0.00
Received By jleahy Date 2022-06-03 Time 16:15 Sent To  
Notes
***NONE***