| Plan Review Stops For Permit 22050716 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2022-09-23 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-09-23 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-09-23 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2022-09-23 11:21:35 | PER ALEXIS SANGELEER "NO THIS PROPERTY ISN???T AN | | | ADDITIONAL UNIT IT WOULD BE CLASSIFIED AS AN ACCESSORY | | | STRUCTURE". NO ADDITIONAL ADDRESS NEEDED. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2022-07-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-07-19 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-07-19 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2022-07-19 15:37:30 | PLEASE CONTACT [email protected] TO DISCUSS | | | ADDRESSING ONCE ZONING HAS APPROVED THE PROJECT. YOU | | | CAN ALSO CALL 561-805-6659 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2023-02-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-02-20 |
Time |
19:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-02-20 |
Time |
19:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-01-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-01-04 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-01-04 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2023-01-04 15:56:02 | RESIDENTIAL (R3) ALTERATION, FOURTH BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22050716 | | | 1222 ALPHA ST | | | | | | ARCHITECTS-ENGINEERS | | | FLORIDA STATUTE 553.80(2)(B): | | | ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN | | | PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT | | | NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | | REVIEW. | | | | | | 1- REVISE ENERGY CALCULATIONS: | | | | | | A)OK. | | | | | | PREVIOUS COMMENT: | | | B)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF | | | FORM. OWNER'S NAME IS INCORRECT. NEED BUILDER'S NAME, | | | PERMIT OFFICE AND JURISDICTION (THIS IS 604700 | | | JURISDICTION). SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | MISSING THE PERMIT OFFICE AND JURISDICTION NUMBER | | | (604700). ALSO, CORRECT ZIP CODE IS 33401 NOT 33304. | | | REVISE AS REQUIRED. | | | | | | C)OK. | | | D)OK. | | | E)OK. | | | | | | PREVIOUS COMMENT: | | | F)CEILING INSULATION SPECIFIED ON ITEM #11 DOESN'T | | | MATCH PLANS. REVISE AS REQUIRED. ALSO, THE CEILING OF | | | THIS STRUCTURE IS NOT FLAT. SEE PLANS AND REVISE AS | | | REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | THIS ITEM HAS TO BE COORDINATED WITH ITEM #2 BELOW. | | | PLANS NEED TO BE REVISED. | | | | | | PREVIOUS COMMENT: | | | G)ITEM #11 SPECIFY VENTED CEILING. PROVIDE DETAILS AND | | | SPECIFICATIONS SHOWING HOW THE CROSS VENTILATION IS | | | PROVIDED. PLANS DON'T SHOW THIS. ROOF NEEDS CROSS | | | VENTILATION AS REQUIRED BY SEC. R806.1 FBC-RESIDENTIAL. | | | R-19 BATT INSULATION DOESN'T FIT ON 2X6 ROOF JOISTS. IT | | | DOESN'T ALLOW ROOF CROSS VENTILATION. SEC. R806.3 | | | FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | | | RESPONSE: | | | ENERGY CALCULATIONS STILL SHOW VENTED ATTIC. PLANS | | | DON'T SHOW ANY ATTIC CROSS VENTILATION. COORDINATE WITH | | | ITEM # 2 BELOW. | | | | | | H)OK. | | | | | | PREVIOUS COMMENT: | | | I)PROVIDE THE NAME OF THE PERSON DOING THE CALCULATIONS | | | AS REQUIRED BY SEC. R405.4.2.1 FBC-ENERGY CONSERVATION. | | | | | | RESPONSE: | | | REPEAT COMMENT. | | | | | | J)OK. | | | | | | PREVIOUS COMMENT: | | | K)ROOF TYPE SPECIFIED ON PAGE 2 DOESN'T MATCH PLANS. | | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | RESPONSE: | | | REPEAT COMMENT. | | | | | | L)OK. | | | M)OK. | | | N(OK. | | | | | | NEW COMMENTS BASED ON REVISED ENERGY CALCULATIONS: | | | | | | 2- IT IS NOT CLEAR IF ENGINEER OF RECORD IS DESIGNING A | | | VENTED OR UNVENTED ATTIC. ENERGY CALCULATIONS SPECIFY | | | VENTED ATTIC BUT PLANS DON'T SHOW VENT INFORMATION. | | | ENGINEER TO READ SEC. R806 BC-RESIDENTIAL | | | AND PROVIDE COMPLETE INFORMATION ON PLANS SHOWING | | | COMPLIANCE WITH ATTIC CROSS VENTILATION SEC. R806.2 | | | FBC-RESIDENTIAL OR ENGINEER TO PROVIDE COMPLETE | | | INFORMATION ON PLANS SHOWING COMPLIANCE WITH UNVENTED | | | ATTIC SEC. R806.5 FBC-RESIDENTIAL. ENGINEER TO SPECIFY | | | TYPE OF INSULATION AND R-VALUE. | | | NOTE: IF USING BATT INSULATION, 2X6 ROOF RAFTERS DON'T | | | HAVE ENOUGH ROOM TO ALLOW INSULATION CLEARANCE FOR | | | CROSS VENTILATION (SEE SEC. R806.3 FBC-RESIDENTIAL). | | | TYPICALLY SPRAY FOAM INSULATION (LIKE ICYNENE) IS USED | | | FOR UNVENTED ATTICS. IF ENGINEER IS DESIGNING UNVENTED | | | ATTIC THEN PROVIDE ICC EVALUATION REPORT FOR THE | | | ICYNENE INSULATION (OR ANY OTHER ONE SPECIFIED BY THE | | | ENGINEER) TO VERIFY COMPLIANCE WITH SEC. R316 | | | FBC-RESIDENTIAL (NOTE: ENGINEER TO REVIEW AND APPROVE | | | THE REPORT IN WRITING PRIOR TO SUBMITTAL TO THIS | | | OFFICE). | | | | | | 3- ENERGY CALCULATIONS WERE REVISED FOR WORST CASE | | | SCENARIO. THIS IS NOT ALLOWED. ENERGY CALCULATIONS NEED | | | TO BE SITE SPECIFIC AS REQUIRED BY SEC. R405.4.2.1 (4) | | | FBC- ENERGY CONSERVATION. REVISE AS REQUIRED. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | | REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-12-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-12-06 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-12-05 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2022-12-06 10:41:23 | RESIDENTIAL (R3) ALTERATION, THIRD BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22050716 | | | 1222 ALPHA ST | | | | | | NOTE: | | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | | CONFLICTS/DELAYS. REVISION FEES APPLY. | | | | | | ***IMPORTANT****CONTRACTOR TO ADVICE IF PROVISO OPTION | | | IS PREFERRED AT THIS TIME OR IF RE-SUBMITTING REQUIRED | | | INFORMATION BEFORE PERMIT ISSUANCE. | | | | | | ***IMPORTANT*** | | | ENERGY CALCULATIONS NEED TO BE CERTIFIED AT THE BOTTOM | | | OF FORM BY THE OWNER/AGENT LINE BEFORE ISSUING THE | | | PERMIT. | | | | | | ORIGINAL COMMENT: | | | 1-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.5 FBC-ENERGY CONSERVATION. | | | NOTE: PLEASE MAKE SURE CALCULATIONS ARE SIGNED BY ALL | | | THE REQUIRED PARTIES, INCLUDING THE OWNER OR AUTHORIZED | | | AGENT TO AVOID CONFLICT/DELAYS. | | | | | | RESPONSE: | | | REVISE ENERGY CALCULATIONS: | | | | | | A)THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER | | | AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL | | | CERTIFY AT THE OWNER/AGENT LINE AT THE BOTTOM OF FORM | | | THAT THE BUILDING IS IN COMPLIANCE WITH THE CODE, AS | | | PER SECTION 553.907, FLORIDA STATUTES, PRIOR TO | | | RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR | | | RENOVATION AS REQUIRED BY SECTION R103.1.1.2 FBC-ENERGY | | | CONSERVATION. | | | | | | B)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF | | | FORM. OWNER'S NAME IS INCORRECT. NEED BUILDER'S NAME, | | | PERMIT OFFICE AND JURISDICTION (THIS IS 604700 | | | JURISDICTION). SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | C)ITEM # 2 IS INCORRECT. THE STRUCTURE IS NOT ATTACHED. | | | REVISE AS REQUIRED. | | | SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | D)ITEM #9(A) SPECIFIES R-19.0 SLAB ON GRADE EDGE | | | INSULATION. PLANS DON'T SHOW THIS INSULATION. PROVIDE | | | COMPLETE DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE | | | WITH THIS. REVISE PLANS AND ENERGY CALCULATIONS AS | | | REQUIRED TO MATCH. ALSO, CLARIFY WHY ITEM #9 SPECIFY | | | AREAS (A) AND (B). WHERE ARE THESE TWO AREAS LOCATED ON | | | THE FLOOR PLAN?. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | E)WALL INSULATION SPECIFIED ON ITEM #10 DOESN'T MATCH | | | PLANS. REVISE AS REQUIRED. ALSO, CLARIFY WHERE IS THE | | | INTERIOR WALL WITH INSULATION?. SEC. R101.5.1.1.2 | | | FBC-RESIDENTIAL. | | | NOTE: R-19 BATT INSULATION DOESN'T FIT ON 2X4 STUDS. | | | | | | F)CEILING INSULATION SPECIFIED ON ITEM #11 DOESN'T | | | MATCH PLANS. REVISE AS REQUIRED. ALSO, THE CEILING OF | | | THIS STRUCTURE IS NOT FLAT. SEE PLANS AND REVISE AS | | | REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | G)ITEM #11 SPECIFY VENTED CEILING. PROVIDE DETAILS AND | | | SPECIFICATIONS SHOWING HOW THE CROSS VENTILATION IS | | | PROVIDED. PLANS DON'T SHOW THIS. ROOF NEEDS CROSS | | | VENTILATION AS REQUIRED BY SEC. R806.1 FBC-RESIDENTIAL. | | | R-19 BATT INSULATION DOESN'T FIT ON 2X6 ROOF JOISTS. IT | | | DOESN'T ALLOW ROOF CROSS VENTILATION. SEC. R806.3 | | | FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | | | H)ENERGY CALCULATIONS ARE TAKING THE CEILING FAN AND | | | CROSS VENTILATION CREDITS ON ITEM #16. PROVIDE COMPLETE | | | DETAILS AND SPECIFICATIONS SHOWING HOW THE HOUSE | | | COMPLIES WITH BOTH CREDITS. SEE SEC. R405.7.6 AND SEC. | | | R405.7.4 FBC-ENERGY CONSERVATION FOR SPECIFIC | | | REQUIREMENTS. | | | | | | I)PROVIDE THE NAME OF THE PERSON DOING THE CALCULATIONS | | | AS REQUIRED BY SEC. R405.4.2.1 FBC-ENERGY CONSERVATION. | | | | | | J)SPACES INFORMATION ON PAGE 2 SPECIFIES THAT THERE IS | | | A KITCHEN IN THIS BUILDING. ACCORDING TO PLANS THERE IS | | | NOT A KITCHEN. ALSO, ZONING DOESN'T ALLOW A KITCHEN. | | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | K)ROOF TYPE SPECIFIED ON PAGE 2 DOESN'T MATCH PLANS. | | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | L)DOORS INFORMATION SPECIFIED ON PAGE 3 IS INCORRECT. | | | SEE PLANS AND PRODUCT APPROVAL AND REVISE AS REQUIRED. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | NOTE: GLAZING IN DOORS NEEDS TO BE INCLUDED IN THE | | | WINDOW GLAZING AREA. SEE SEC. R405.5.3 FBC-ENERGY | | | CONSERVATION). | | | | | | M)WINDOWS OVERHANG SEPARATION SPECIFIED ON PAGE 3 FOR | | | NORTH AND SOUTH ELEVATIONS IS INCORRECT. SEE PLANS AND | | | REVISES AS REQUIRED. SEC. R101.5.1.1.2 FBC-RESIDENTIAL. | | | | | | N) BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE | | | LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY | | | CONSERVATION. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | | REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-09-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-09-23 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-09-23 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2022-09-23 11:23:59 | RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22050716 | | | 1222 ALPHA ST | | | | | | ORIGINAL COMMENT: | | | 1-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.5 FBC-ENERGY CONSERVATION. | | | NOTE: PLEASE MAKE SURE CALCULATIONS ARE SIGNED BY ALL | | | THE REQUIRED PARTIES, INCLUDING THE OWNER OR AUTHORIZED | | | AGENT TO AVOID CONFLICT/DELAYS. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | 2-OK. | | | 3-OK. | | | | | | ORIGINAL COMMENT: | | | 4- BEDROOM EGRESS WINDOWS SIZE 36"X48" SINGLE HUNG | | | SPECIFIED DON'T SEEM TO COMPLY WITH THE MINIMUM CLEAR | | | OPENING REQUIREMENTS OF SEC. R310.2.1 FBC-RESIDENTIAL. | | | REVISE AS REQUIRED. TYPICALLY, 48" HEIGHT WINDOW | | | DOESN'T PROVIDE THE 24" CLEAR HEIGHT OPENING. REVISE | | | WINDOW SIZE AS REQUIRED OR PROVIDE MANUFACTURER'S | | | SPECIFICATIONS SHOWING COMPLIANCE. | | | | | | RESPONSE: | | | WINDOW #1 WAS REVISED WITH NEW SIZE 36"X49 5/8" SINGLE | | | HUNG WINDOW. THIS WINDOW DOESN'T SEEM TO COMPLY. | | | PROVIDE MANUFACTURER'S CUT SHEETS SHOWING COMPLIANCE | | | WITH ALL THE EGRESS REQUIREMENTS. | | | NOTE: FLOOR PLAN CALLS WINDOW #2 AS THE EGRESS WINDOW. | | | INFORMATION ON THE WINDOW SCHEDULE ON SAME SHEET | | | DOESN'T MATCH THIS. REVISE AS REQUIRED TO MATCH. | | | ALSO, TO AVOID CONFLICTS/DELAYS NEED TO COORDINATE | | | WINDOW NOA'S NUMBERS SPECIFIED ON THE WINDOW SCHEDULE | | | WITH WINDOWS NOA'S SUBMITTED. REVISE. | | | ALSO, WINDOWS NUMBER SHOWN ON THE EXTERIOR ELEVATIONS | | | DON'T MATCH THOSE SHOWN ON THE FLOOR PLAN. REVISE. | | | | | | 5- OK. | | | 6- OK. | | | 7- OK. | | | 8- OK. | | | 9- OK. | | | 10-OK. | | | 11-OK. | | | 12-OK. | | | 13-OK. | | | | | | ORIGINAL COMMENT: | | | 14- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | NOTE: SINGLE HUNG WINDOWS NOA SPECIFIED ON PLANS DON'T | | | MATCH NOA SUBMITTED. REVISE AS REQUIRED TO MATCH. | | | | | | RESPONSE: | | | NEED TO COORDINATE WINDOW NOA'S NUMBERS SPECIFIED ON | | | THE WINDOW SCHEDULE WITH WINDOWS NOA'S SUBMITTED. | | | REVISE AS REQUIRED TO MATCH. | | | | | | ORIGINAL COMMENT: | | | 15- FLOOD ZONE INFORMATION SHOWN ON SHEET 1 IS | | | INCORRECT. THE CURRENT FLOOD MAP WENT INTO EFFECT ON | | | 10/05/2017. REVISE ALL FLOOD INFORMATION AS REQUIRED. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | RESPONSE: | | | INFORMATION IS INCORRECT. THE CURRENT FLOOD MAP WENT | | | INTO EFFECT ON 10/05/2017. REVISE INFORMATION AS | | | REQUIRED BASED ON CURRENT MAPS. | | | NOTE: THIS HOUSE IS NO LOCATED ON A SPECIAL FLOOD ZONE. | | | FLOOD ZONE IS NOT REQUIRED TO BE SUBMITTED. PROVIDE | | | CORRECT INFORMATION OR DELETE TO AVOID | | | CONFLICTS/DELAYS. | | | | | | ORIGINAL COMMENT: | | | 16- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. REVISE VALUATION TO INCLUDE EVERYTHING , | | | INCLUDING THE DESIGN PROFESSIONAL FEES. | | | | | | RESPONSE: | | | REPEAT COMMENT. | | | | | | NEW COMMENT: | | | 17- IT WAS NOTED THAT SITE PLAN INFORMATION IS | | | INCORRECT. ENGINEER OF RECORD IS SHOWING THIS LOT AS A | | | CORNER LOT. ACCORDING TO PROPERTY APPRAISER RECORDS | | | THIS IS NOT CORNER LOT. THE CORNER LOT ADDRESS IS 1290 | | | ALPHA ST. AND BELONGS TO ANOTHER OWNER. THIS DRAWING IS | | | SUBMITTED FOR PUBLIC RECORDS AND NEEDS TO BE ACCURATE. | | | ENGINEER OF RECORD TO JUSTIFY WHY ALTERING THE | | | INFORMATION TO MAKE BELIEVE THE LOT IS 100 FEET WIDE | | | AND SHOWING ONLY ONE HOUSE AND THE ACCESSORY STRUCTURE. | | | REVISE SITE PLAN AND PROVIDE CURRENT SURVEY TO VERIFY | | | CORRECT INFORMATION. | | | SEC. 107.2.5 CITY AMENDMENTS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | | REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-07-21 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-07-20 |
Time |
18:03 |
Sent To |
|
|
| Notes |
| 2022-07-21 16:58:36 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #22050716 | | | 1222 ALPHA ST | | | | | | | | | NOTE: | | | CHANGE OF OCCUPANCY SEC. 605 AND SETC. 1001.2.1, SEC. | | | 604 AND SEC. 901.2, SEC. 801.3 FBC-EXISTING BUILDING. | | | ALL NEW WORK SHALL COMPLY WITH THE MATERIALS AND | | | METHODS REQUIREMENTS IN THE FLORIDA BUILDING CODE. | | | | | | NOTE: | | | LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING BUILDING. | | | SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 | | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | | | 1-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | R101.5 FBC-ENERGY CONSERVATION. | | | NOTE: PLEASE MAKE SURE CALCULATIONS ARE SIGNED BY ALL | | | THE REQUIRED PARTIES, INCLUDING THE OWNER OR AUTHORIZED | | | AGENT TO AVOID CONFLICT/DELAYS. | | | | | | 2-ENGINEER OF RECORD NEEDS TO SPECIFY COMPLETE DESIGN | | | CRITERIA: | | | A)BUILDING EXPOSURE. | | | B)ULTIMATE AND NOMINAL WIND SPEEDS. | | | C)DOORS AND WINDOWS DESIGN PRESSURES (NOMINAL | | | PRESSURES). | | | SEC. R301.2.1 FBC RESIDENTIAL. | | | | | | 3- PLANS ARE NOT CLEAR IF THE PROPOSED USE IS A | | | COMPLETE INDEPENDENT DWELLING UNIT WITH A KITCHEN OR | | | NOT. SCOPE OF WORK ON SHEET 1 SPECIFIES "EXISTING SHED | | | IN GUEST HOUSE WITH KITCHEN, LIVING ROOM, BATHROOM, | | | LAUNDRY ROOM, BEDROOM AND ATTIC". | | | BUILDING SECTION ON SHEET 1 IDENTIFY A KITCHEN AREA BUT | | | FLOOR PLANS AND ELECTRICAL PLANS AND CALCULATIONS DON'T | | | IDENTIFY THE KITCHEN. PLANS AND ELECTRICAL CALCULATIONS | | | DON'T SHOW THE RANGE. IN ORDER TO AVOID | | | CONFLICTS/DELAYS PLEASE CLEARLY NAME THE KITCHEN AREA | | | ON PLANS. THIS INCLUDES THE ELECTRICAL PLANS AND | | | CALCULATIONS. | | | NOTE: REVISE SCOPE OF WORK AND PLANS TO MATCH. SEC. | | | 102.2 CITY AMENDMENTS. ALSO, ENERGY CALCULATIONS ALSO | | | NEED TO CONSIDER THE KITCHEN. COORDINATE AS REQUIRED TO | | | AVOID CONFLICTS/DELAYS. | | | | | | 4- BEDROOM EGRESS WINDOWS SIZE 36"X48" SINGLE HUNG | | | SPECIFIED DON'T SEEM TO COMPLY WITH THE MINIMUM CLEAR | | | OPENING REQUIREMENTS OF SEC. R310.2.1 FBC-RESIDENTIAL. | | | REVISE AS REQUIRED. TYPICALLY, 48" HEIGHT WINDOW | | | DOESN'T PROVIDE THE 24" CLEAR HEIGHT OPENING. REVISE | | | WINDOW SIZE AS REQUIRED OR PROVIDE MANUFACTURER'S | | | SPECIFICATIONS SHOWING COMPLIANCE. | | | | | | 5- SPECIFY SIZE OF ENTRY DOOR TO VERIFY COMPLIANCE WITH | | | EGRESS SEC. R311.2 FBC-RESIDENTIAL. | | | | | | 6- PROPOSED HABITABLE ATTIC DOESN'T COMPLY. SEE | | | HABITABLE ATTIC DEFINITION ON CHAPTER 2 OF | | | FBC-RESIDENTIAL. NEED TO COMPLY WITH ALL THE | | | REQUIREMENTS. | | | NOTE: THERE MAY BE MORE COMMENTS BASED ON THE REVISED | | | PLANS SHOWING PROPOSED USE AND ACCESS TO THIS SPACE. | | | | | | 7- LADDER TO PROPOSED HABITABLE ATTIC IS NOT ALLOWED | | | BECAUSE PROPOSED HABITABLE ATTIC DOESN'T COMPLY. SEC. | | | R311.7.12 FBC-RESIDENTIAL. ALSO, PROPOSED LADDER | | | DOESN'T COMPLY EITHER. SEE SEC. R311.7.12 | | | FBC-RESIDENTIAL. | | | | | | 8- PROVIDE COMPLETE FRAMING PLAN FOR SPACE ABOVE | | | BEDROOM. SPECIFY ALL STRUCTURAL FRAMING MEMBERS, | | | SPACING AND ALL CONNECTORS. SEC. R301.1 | | | FBC-RESIDENTIAL. | | | | | | 9- PROVIDE COMPLETE FRAMING DETAIL AND SPECIFICATIONS | | | FOR ALL EXTERIOR DOORS AND WINDOWS OPENINGS. SPECIFY | | | ALL FRAMING MEMBERS AND CONNECTORS. EC. R301.1 | | | FBC-RESIDENTIAL. | | | | | | 10- PLANS DON'T SHOW HOW PROVIDING HEAT TO THE NEW | | | BEDROOM AND LIVABLE AREAS AS REQUIRED BY SEC. R303.10 | | | FBC-RESIDENTIAL. | | | | | | 11- ENGINEER OF RECORD NEEDS TO DEPICT THE BUILDING | | | THERMAL ENVELOPE AND SPECIFY INSULATION MATERIALS AND | | | THEIR R-VALUES.(ROOF, WALLS, RAISED FLOOR ABOVE GARAGE, | | | ETC.) AS REQUIRED BY SEC. R103.2 FBC-ENERGY | | | CONSERVATION. | | | NOTE: BUILDING SECTION 2 ONLY SHOWS INSULATION ABOVE | | | THE BEDROOM. NEED TO SHOW AND SPECIFY TYPE AND R-VALUE | | | INSULATION ON ALL EXTERIOR WALLS, CEILING, ETC. | | | | | | 12- THIS IS A CHANGE OF USE FROM GARAGE TO LIVABLE | | | SPACE. TYPICALLY, GARAGES ARE BUILT WITHOUT A FLOOR | | | VAPOR BARRIER. ENGINEER OF RECORD TO PROVIDE | | | SPECIFICATIONS SHOWING COMPLIANCE FOR THE CONCRETE SLAB | | | VAPOR BARRIER AS REQUIRED BY SEC. R506.2.3 | | | FBC-RESIDENTIAL. | | | | | | 13- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC | | | 61G20-3.001 FOR: | | | A)HURRICANE SHUTTERS. FRENCH DOORS NOA 20-0427.06 | | | SUBMITTED IS FOR NON IMPACT DOOR. NEED HURRICANE | | | SHUTTERS PRODUCT APPROVAL AND PROVIDE COMPLETE | | | INSTALLATION SCHEDULE. SEE CITY SAMPLE. | | | | | | 14- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | NOTE: SINGLE HUNG WINDOWS NOA SPECIFIED ON PLANS DON'T | | | MATCH NOA SUBMITTED. REVISE AS REQUIRED TO MATCH. | | | | | | 15- FLOOD ZONE INFORMATION SHOWN ON SHEET 1 IS | | | INCORRECT. THE CURRENT FLOOD MAP WENT INTO EFFECT ON | | | 10/05/2017. REVISE ALL FLOOD INFORMATION AS REQUIRED. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 16- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. REVISE VALUATION TO INCLUDE EVERYTHING , | | | INCLUDING THE DESIGN PROFESSIONAL FEES. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE | | | REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-01-06 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-01-06 |
Time |
15:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-12-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-12-06 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-12-06 |
Time |
07:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-09-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-26 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-26 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-06-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-06-02 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-06-02 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2022-06-02 13:59:34 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) BUILDING WILL REQUIRE A GROUNDING ELECTRODE SYSTEM | | | | | | 250.32 BUILDINGS OR STRUCTURES SUPPLIED BY A FEEDER(S) | | | OR | | | BRANCH CIRCUIT(S). | | | (A) GROUNDING ELECTRODE. BUILDING(S) OR STRUCTURE(S) | | | SUPPLIED BY FEEDER(S) OR BRANCH CIRCUIT(S) SHALL HAVE A | | | GROUNDING | | | ELECTRODE OR GROUNDING ELECTRODE SYSTEM INSTALLED IN | | | ACCORDANCE WITH PART III OF ARTICLE 250. THE GROUNDING | | | ELECTRODE | | | CONDUCTOR(S) SHALL BE CONNECTED IN ACCORDANCE WITH | | | 250.32(B) OR (C). WHERE THERE IS NO EXISTING GROUNDING | | | ELECTRODE, | | | THE GROUNDING ELECTRODE(S) REQUIRED IN 250.50 SHALL BE | | | INSTALLED. | | | | | | 2) SMOKE ALARMS ARE REQUIRED PER FBC R314 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-02-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-02-20 |
Time |
19:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-01-25 |
Time |
15:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-01-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-01-06 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-12-27 |
Time |
08:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-12-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-12-06 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-11-04 |
Time |
17:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-09-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-26 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-09 |
Time |
07:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-07-21 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-05-16 |
Time |
06:12 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2023-04-28 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-04-28 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-02-21 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2023-04-24 09:01:28 | RECEIPT MU-2023-007734 - $1945.04 PAID | | 2023-02-21 10:31:26 | EMAILED IMPACT FOR REVIEW-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2023-01-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-01-04 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-01-04 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2023-01-04 15:57:05 | NOTE: | | | IMPACT FEES QUESTIONNAIRE WAS UPLOADED TO PROJECTDOX. | | | PERMIT LIBRARIAN WILL EMAIL COUNTY FOR IMPACT FEES | | | ASSESSMENT ONCE PLANS ARE APPROVED. JG. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2022-09-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-09-23 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-09-23 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2022-09-23 11:26:43 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-07-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-07-20 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-07-20 |
Time |
18:15 |
Sent To |
|
|
| Notes |
| 2022-07-20 18:18:27 | IMPACT FEES | | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | | IMPACT FEE ASSESSMENT. | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2022-12-29 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-29 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-29 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-11-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-11 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-11 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-09-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-19 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-19 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2022-09-19 07:45:31 | ADDRESS THE FOLLOWING COMMENTS FROM PREVIOUS REVIEW | | | BELOW: | | | | | | 1) PROVIDE THE ENERGY CALCULATIONS FOR THIS PROJECT. | | | FEC R402 | | | | | | 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | FOR THE MECHANICAL SYSTEM FOR THIS PROJECT. FEC R403.7 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-05-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-24 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-23 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2022-05-23 16:40:26 | 1ST REVIEW FMC | | | PERMIT: 22050716 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE THE ENERGY CALCULATIONS FOR THIS PROJECT. | | | FEC R402 | | | | | | 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | FOR THE MECHANICAL SYSTEM FOR THIS PROJECT. FEC R403.7 | | | | | | 3) PROVIDE A MECHANICAL DRAWING FOR THE MECHANICAL | | | SYSTEMS FOR THIS PROJECT INCLUDING THE HEAT/AC, BATH | | | FAN EXHAUST, DRYER DUCT AND EXHAUST TERMINATION | | | LOCATION AND THE LOCATION OF THE CONDENSING UNIT AND | | | ANCHORING DETAIL. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | 2022-05-23 16:37:17 | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-11-07 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-11-07 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-11-07 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-09-19 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-09-19 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-09-19 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2022-09-19 07:48:15 | 2ND PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. DONE | | | | | | 2. COMMENT NOT ADDRESSED, IMPROPER VENTING | | | CONFIGURATION ------- 2020 FRC P3108.1 - THE KITCHEN | | | SINK AND LAUNDRY CANNOT BE INCLUDED IN WET VENTING. | | | ONLY BATHROOM GROUP FIXTURES CAN BE INCLUDED IN A WET | | | VENT SYSTEM. ALL OTHER FIXTURES MUST DISCHARGE | | | DOWNSTREAM. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-05-21 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-05-21 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-05-21 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2022-05-21 08:33:17 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMEND - 107.3.5.3 (12.) - PLEASE SHOW THE | | | DRAIN, WASTE AND VENT DIAGRAM IN ISOMETRIC FORM FOR | | | CLARITY. | | | | | | 2. 2020 FRC P3108.1 - THE KITCHEN SINK AND LAUNDRY | | | CANNOT BE INCLUDED IN WET VENTING. ONLY BATHROOM GROUP | | | FIXTURES CAN BE INCLUDED IN A WET VENT SYSTEM. ALL | | | OTHER FIXTURES MUST DISCHARGE DOWNSTREAM. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2023-02-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-02-20 |
Time |
19:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-02-20 |
Time |
19:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-01-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-01-04 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-01-04 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-11-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-11 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-11 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-09-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2022-09-23 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2022-09-23 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-05-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-23 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-23 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2023-01-31 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-01-31 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-01-31 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2022-12-29 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-12-29 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-12-29 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2022-11-30 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-11-30 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-11-30 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2022-11-21 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-11-21 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-11-21 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2022-11-21 12:09:41 | FAILED | | | 11/21/2022 | | | | | | | | | PLEASE PROVIDE A SURVEY WITH LABELED SETBACKS OF THE | | | PROPOSED GUEST HOUSE. | | | | | | | | | | | | ALEXIS SANGELEER | | | ASSOCIATE PLANNER | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-09-23 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-09-21 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-09-23 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2022-09-23 08:15:55 | FAILED | | | 9/23/2022 | | | | | | | | | THIS IS NOT THE CORRECT SITE PLAN/SURVEY FOR THE | | | ADDRESS OF 1222 ALPHA STREET PLEASE SUBMIT THE CORRECT | | | SURVEY. | | | | | | | | | ALEXIS SANGELEER | | | ASSOCIATE PLANNER | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-05-24 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-05-24 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-05-24 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2022-05-24 09:01:06 | 5/24/2022 | | | FAIL | | | PLEASE PROVIDE A SURVEY WITH THE SETBACKS OF THE | | | PROPOSED GUEST HOUSE. | | | | | | | | | | | | ARTICLE X SECTION 94-304 CITY ZONING AND LAND | | | DEVELOPMENT REGULATIONS: | | | ******************************************************* | | | ******************************* | | | FRONT: 25 FEET. | | | SIDE: FIVE FEET FROM THE LOT LINES. | | | CORNER: SAME AS REQUIRED FOR PRINCIPAL STRUCTURE. | | | REAR: FIVE FEET MINIMUM OR 15 FEET FROM THE CENTERLINE | | | OF THE ALLEY TO A GARAGE DOOR FACING THE ALLEY, | | | WHICHEVER IS GREATER. | | | | | | ARTICLE X. SECTION 9-303 CITY ZONING AND LAND | | | DEVELOPMENT REGULATIONS: | | | ******************************************************* | | | ****************************** | | | MINIMUM LOT AREA: 6,000 SQUARE FEET | | | ADDITIONAL STANDARDS. | | | ALL ACCESSORY APARTMENTS MUST COMPLY WITH THE | | | DEVELOPMENT STANDARDS FOR RESIDENTIAL ACCESSORY | | | STRUCTURES. | | | LOT WIDTH: 60 FEET | | | MAXIMUM UNIT SIZE: 800 SQUARE FEET. | | | PARKING: ONE PARKING SPACE SHALL BE PROVIDED FOR THE | | | APARTMENT AND TWO FOR THE PRINCIPAL STRUCTURE ON SITE. | | | MAXIMUM HEIGHT: ACCESSORY APARTMENTS SHALL NOT EXCEED | | | 25 FEET IN HEIGHT. | | | | | | | | | | | | | | | ALEXIS SANGELEER | | | ASSOCIATE PLANNER | | | [email protected] |
|
|