| Plan Review Stops For Permit 22050702 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-08-01 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-08-01 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-18 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-18 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2022-07-18 08:57:50 | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. | | | | | | THE PAGES HAVE THE IMAGE OF THE DIGITAL SIGNATURE BUT | | | THE ACTUAL DIGITAL SIGNATURE CERTIFICATE WAS REMOVED | | | FROM THE DOCUMENT. THIS CAN OCCUR IF THE DOCUMENT WAS | | | ALTERED, FOR INSTANCE IF A MULTIPAGE PDF WAS SPLIT INTO | | | INDIVIDUAL PDFS. | | | | | | PLEASE HAVE THE ENGINEER PROVIDE SINGLE PAGE PDFS, EACH | | | DIGITALLY SIGNED. IF YOU WOULD LIKE FOR US TO CONFIRM | | | THE DIGITAL SIGNATURE BEFORE YOU RESUBMIT, EMAIL A PAGE | | | TO: | | | | | | [email protected] | | | [email protected] | | | | | | AND REQUEST THAT WE VERIFY THAT THE PAGES ARE DIGITALLY | | | SIGNED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-04 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-08-04 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-06-07 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-07 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-07 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2022-06-07 13:53:34 | ELECTRIC REVIEW FAILED | | | 1) PANEL SCHEDULE DETAILS 200 AMP MAIN BREAKER PANEL. | | | RISE DIAGRAM DETAILS AN UNKNOWN PANEL INSIDE FED BY #1 | | | CU CONDUCTORS FROM EQIPMENT DETAILED ONLY AS 200 METER | | | MAIN. PLEASE DETAIL CORRECT RISER DIAGRAM DETAILING | | | EITHER CORRECTLY SIZED CONDUCTORS OR APPROPRIATE | | | OVERCURRENT PROTECTION. NEC 215.5 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-08-01 |
Time |
05:55 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-08-01 |
Time |
05:55 |
Sent To |
|
|
| Notes |
| 2022-08-01 05:55:34 | GAS SUB PERMIT REQUIRED |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-05-25 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-05-25 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2022-05-25 12:24:11 | 1ST GAS REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMENDS 107.2.1 - YOU HAVE DETAILED A GAS | | | RANGE. PLEASE INCLUDE THE GAS RISER INCLUDING PIPE | | | SIZES, PIPE LENGTHS, PIPE SIZING CHART FOR BTU LOAD, | | | AND TYPE OF GAS. IF YOU INTEND TO DO THE GAS ON A | | | SEPERATE PERMIT, PLEASE INDICATE THE CORRESPONDING | | | PERMIT NUMBER. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-08-04 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-07-29 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-18 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-05-23 |
Time |
07:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-08-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2022-08-02 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2022-08-02 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-25 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-25 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2022-05-25 15:39:39 | PROVIDE A MECHANICAL DRAWING THAT SHOWS ALL MECHANICAL | | | WORK BEING COMPLETED UNDER THIS PERMIT INCLUDING NEW | | | SUPPLY AND RETURN DUCTS. THE DRYER DUCT INSTALLATION IN | | | THE NEW LAUNDRY ROOM AND IF A KITCHEN HOOD IS BEING | | | INSTALLED ABOVE THE NEW RANGE PROVIDE DETAILS SUCH AS | | | THE CFM'S OF EXHAUST AND IF MAKE UP AIR IS REQUIRED. | | | FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-08-01 |
Time |
05:55 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-08-01 |
Time |
05:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-05-25 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-05-25 |
Time |
12:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-08-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-08-01 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-08-01 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-07-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-18 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-18 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2022-07-18 08:58:10 | SEE BUILDING REVIEW | | | |
|
|