|
 |
 |
 |
 |
 |
Plan Review Details - Permit 22050546
| Plan Review Stops For Permit 22050546 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-06-07 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-07 |
Time |
06:17 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-07 |
Time |
06:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-05-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-05-27 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-05-27 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2022-05-27 15:16:43 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 1.) FBC B /WPB AMENDMENTS 109.3, THE VALUATION APPEARS | | | TO BE LOW. PLEASE RE-EVALUATE, SHOW SQUARE FOOTAGE, AND | | | PROVIDE A FLOOR PLAN WITH DIMENSIONS AND INDICATIONS | | | FOR THE AREAS OF WORK/NEW FLOORING. | | | | | | 2.) FBC B/WPB AMENDMENTS 107.2.1,THE SUBMITTED PLAN | | | SHEET APPEARS TO BE FROM THE BUILDING DESIGN. THIS IS | | | OK AS A SUPPORTING DOCUMENT. PLEASE PROVIDE A NEW FLOOR | | | PLAN THAT DOES NOT HAVE A TITLE BLOCK. | | | | | | 3.) FBC B/WPB AMENDMENTS 107.2.1 THIS NEW FLOOR PLAN | | | MUST HAVE THE NAME, THE SIGNATURE, AND CONTRACTOR'S | | | LICENSE FROM THE INDIVIDUAL RESPONSIBLE FOR THE NEW | | | SUBMITTED FLOOR PLAN. | | | | | | 4.) FBC B 107.2.1, PROVIDE INFORMATION INCLUDING | | | MANUFACTURER'S SPECIFICATIONS OF TILE TO BE INSTALLED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-05-24 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-05-20 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-05-24 09:51:26 | THE FLOORING IS A PORCELAIN TILE. | | | | | | THANK YOU, | | | | | | | | | | | | ALICIA PIZZI | | | PRESIDENT | | | PZ CONSTRUCTION AND CONSULTING, INC | | | CGC1511677 | | | 561-815-9333 | | | | | | PER THE CONTRACTOR, THE FLOORING IS PORCELAIN TILE, | | | REVIEW IS CHANGED TO PASS BY FIRE. | | | | | | C. WALKER | | | | | | [email protected] | | | | | | 561-804-4762 | | 2022-05-20 10:46:39 | PROVIDE INFORMATION ON THE TYPE OF TILE (CERAMIC, | | | PORCELEIN, VINYL, WOOD, ETC.) TO BE INSTALLED. NFPA 101 | | | 10.2.7 | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-05-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-05-27 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-05-18 |
Time |
06:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-05-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-05-27 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-05-27 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |