| Plan Review Stops For Permit 22050464 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2022-07-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-07-01 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-07-01 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2022-07-01 12:01:04 | WORK IS FOR BOTH BUILDINGS, HALF ADDRESS AND PRIMARY | | | ADDRESS READDRESSED. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-06-29 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-06-29 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2022-06-29 16:53:02 | WHICH BUILDING IS THE WORK TO BE DONE, EAST OR WEST? | | | THE EAST BUILDING HAS A HALF ADDRESS WHICH WILL NEED TO | | | BE READDRESSED. PRIMARY ADDRESS OF 3718 GREENWOOD AVE | | | WILL ALSO NEED TO BE CHANGED DUE TO IT HAVING AN ODD | | | NUMBER AND IT IS ON THE EVEN SIDE OF THE STREET, NEEDS | | | TO HAVE AN EVEN ADDRESS. PLEASE HAVE THE OWNER CONTACT | | | [email protected] OR CALL 561-805-6659 TO READDRESS | | | THE HALF ADDRESS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-07-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-25 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-25 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-07-12 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-07-12 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-07-12 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2022-07-12 13:51:41 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER TO CORRECT DESIGN | | | PRESSURES & NAILING PATTERNS. EXPOSURE CATEGORY C ZONE | | | 3 MINIMUM DESIGN PRESSURE IS -108.17 AS PER CHAPTER 3 | | | FBC R 7TH EDITION (2020) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-06-29 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-06-29 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2022-06-29 09:15:34 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. CITY OF WEST PALM BEACH IS NOT | | | LOCATED IN A HVHZ AND HAS NOT ADOPTED RAS 128. GENERAL | | | LIMITATION #7 IS SPECIFICALLY REFERRED TO IN THIS NOA. | | | SUBMIT FASTENER DENSITY CALCULATIONS PREPARED, SIGNED | | | AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL | | | ENGINEER, REGISTERED ARCHITECT, OR REGISTERED ROOF | | | CONSULTANT. NOTE: THIS PROJECT IS LOCATED IN A CATEGORY | | | C AREA. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-07-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-25 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-18 |
Time |
17:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-07-12 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-07-12 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-06-29 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-06-29 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-06-28 |
Time |
10:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-07-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-25 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-25 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-07-12 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-07-12 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-07-12 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2022-07-12 13:50:56 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | SUBMITTED SIGNED AND SEALED ENHANCED NAILING | | | CALCULATIONS IS A COPY OF A WET SIGNATURE. PLEASE | | | UPLOAD A VALID ELECTRONICALLY SIGNED PLAN/DOCUMENT TO | | | PROJECTDOX | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|