Plan Review Details - Permit 22050234
Plan Review Stops For Permit 22050234
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-07-14 Cont ID  
Sent By rmcdouga Date 2022-07-14 Time 16:14 Rev Time 0.00
Received By rmcdouga Date 2022-07-14 Time 16:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-05-26 Cont ID  
Sent By ppetty Date 2022-05-26 Time 13:23 Rev Time 0.00
Received By ppetty Date 2022-05-26 Time 12:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-07-20 Time   Rev Time 0.00
Received By lmarchan Date 2022-07-18 Time 10:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-14 Cont ID  
Sent By rmcdouga Date 2022-07-14 Time 16:14 Rev Time 0.00
Received By rmcdouga Date 2022-05-06 Time 07:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-07-20 Cont ID  
Sent By ccole Date 2022-07-20 Time 10:48 Rev Time 0.00
Received By ccole Date 2022-07-20 Time 10:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-05-17 Cont ID  
Sent By ccole Date 2022-05-17 Time 12:48 Rev Time 0.00
Received By ccole Date 2022-05-17 Time 11:56 Sent To  
Notes
2022-05-17 12:49:211ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22050234
 5/17/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 3: THE TDH CALCS SHOW FRICTION LOSS FOR A
 HEATER. PLEASE SHOW THE HEATER LOCATION AND PIPING IN
 THE SCHEMATIC, AND PROVIDE AN EQUIPMENT SCHEDULE- MAKE,
 MODEL, ELECTRIC OR GAS POWER, EFFICIENCY RATING- SEC.
 107.2.1 WPB. PLEASE NOTE THAT A SEPARATE PERMIT IS
 REQUIRED FOR A GAS WATER HEATER- SEC. 105.1 WPB.
  
 2) SHEETS 2 OR 3: INDICATE THE WATER SUPPLY SOURCE FOR
 THE POOL- SEC. R4501.9 FBC RES. PLEASE NOTE
 INSTALLATION OF AN AUTO FILL AND THE REQUIRED AVB
 BACKFLOW PREVENTER AT THE DEVICE SHALL BE INSTALLED BY
 A FL. LICENSED PLUMBER- CFC NOT CPC. THE INSTALLATION
 CAN BE DONE AS A SUB-PERMIT FOR THE MASTER, OR UNDER A
 SEPARATE PERMIT.
  
 3) INSTALLATION OF THE NEW POOL AT THE RESIDENCE
 REQUIRES INSTALLATION OF A POTABLE WATER SERVICE RPZ
 BACKFLOW PREVENTER IN ACCORDANCE WITH SEC. D & E WPB
 CROSS CONNECTION MANUAL.
 A FL. LICENSED PLUMBING CONTRACTOR SHALL OBTAIN A
 SEPARATE PERMIT FOR INSTALLATION OF THE BACKFLOW
 PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB AND SEC.
 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL BE
 TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT
 PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT.
 PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS
 DEPT.AT 561-822-2210 FOR FURTHER INFORMATION
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-07-20 Cont ID  
Sent By ccole Date 2022-07-20 Time 10:53 Rev Time 0.00
Received By ccole Date 2022-07-20 Time 10:36 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-26 Cont ID  
Sent By ppetty Date 2022-05-26 Time 13:23 Rev Time 0.00
Received By ppetty Date 2022-05-26 Time 13:23 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-05-12 Cont ID  
Sent By asangele Date 2022-05-12 Time 13:17 Rev Time 0.00
Received By asangele Date 2022-05-12 Time 13:17 Sent To  
Notes
***NONE***