| Plan Review Stops For Permit 22050195 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2022-09-26 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-09-26 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-09-26 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2022-09-26 16:51:36 | PER ZONING THE NEW BUILDING IS AN EXTENSION OF 516 26TH | | | ST DUE TO THE ROOFED BREEZE WAY AND AS SUCH THE PROJECT | | | WOULD HAVE THE 516 26TH ST ADDRESS FOR THE PROJECT. | | | SHOULD THE PARCEL BE SUB DIVED THEN AN ADDRESS MAY BE | | | APPROPRIATE FOR THIS BUILDING. PLEASE CONTACT | | | [email protected] SHOULD THE PARCEL BE DIVIDED. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2022-09-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-09-14 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-09-14 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2022-09-14 13:52:07 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2022-05-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-05-11 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-05-11 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2022-05-11 16:10:41 | CURRENTLY THERE ARE 2 BUILDINGS WITH UNIQUE ADDRESSES | | | 516 26TH ST (NORTH EAST BLDG) AND 518 26TH ST (SOUTH | | | EAST BLDG), DUE TO MULTIPLE BUILDINGS ON PROPERTY | | | PLEASE COORDINATE WITH [email protected] OR CALL | | | 561-805-6659 FOR THE HABITABLE BUILDING TO BE GIVEN AN | | | ADDRESS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-11-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-07 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-11-07 |
Time |
10:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-09-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-16 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-16 |
Time |
14:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-11 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-08 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2022-07-11 08:31:49 | NEW GARAGE AND GUEST HOUSE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVAL FOR THE OVERHEAD GARAGE DOOR - ALL | | | PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE BUILDING DESIGNER OF RECORD OR THE | | | PRODUCT APPROVAL NUMBER NEEDS TO BE SHOWN ON THE | | | DRAWINGS. | | | | | | 2) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVAL FOR THE ROOF TILE ADHESIVE. | | | | | | 3) PLEASE SHOW THE REQUIRED EMERGENCY EGRESS FROM THE | | | BED ROOMS - WINDOW "C" HAS RAILING BLOCKING THE EGRESS | | | - WINDOW "A" DOES NOT MEET THE EMERGENCY EGRESS SIZE | | | FBC R310.1 | | | | | | 4) THE DRAWINGS SHOW 1/2 INCH DRYWALL ON THE GARAGE | | | CEILING - WITH DWELING SPACE ABOVE SHOULD BE 5/8 INCH | | | PER FBC TABLE R302.6 | | | | | | 5) R30 BATT INSULATION MAY NOT HAVE THE 1 INCH | | | VENTILATION SPACE PER FBC R806.3 VENT AND INSULATION | | | CLEARANCE. | | | WHERE EAVE OR CORNICE VENTS ARE INSTALLED, BLOCKING, | | | BRIDGING AND INSULATION SHALL NOT BLOCK THE FREE FLOW | | | OF AIR. NOT LESS THAN A 1-INCH (25 MM) SPACE SHALL BE | | | PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING | | | AND AT THE LOCATION OF THE VENT. | | | | | | 6) ROOF VENTILATION IS REQUIRED PER FBC R806.1 | | | VENTILATION REQUIRED. | | | ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE | | | CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF | | | RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE | | | SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE | | | ENTRANCE OF RAIN OR SNOW. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-06-01 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-06-01 |
Time |
20:05 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-06-01 |
Time |
18:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-05-31 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-05-31 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-11-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-11-07 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-10-29 |
Time |
07:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-10-11 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-10-11 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-09-08 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-11 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-11 |
Time |
05:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-11-02 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-11-02 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-10-18 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2022-11-02 11:42:40 | NO IMPACT FEES DUE, SEE EMAIL UPLOADED AO | | 2022-10-18 13:57:47 | 10/18/22 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-11 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-11 |
Time |
08:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-09-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-14 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-14 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-05-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-24 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-24 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2022-05-24 10:35:42 | PROVIDE THE ENERGY CALCULATIONS FOR THIS PROJECT. FEC | | | | | | PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | | FOR THIS PROJECT. FEC R403.7.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-05-21 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-05-21 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-05-21 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-09-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-16 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-16 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-11 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-11 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2022-07-11 08:33:14 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-09-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-09-16 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-09-16 |
Time |
14:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-07-11 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-07-11 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2022-05-24 10:36:21 | DIGITAL SIGNATURES FOR MECHANICAL DOCUMENTS APPROVED ME | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-10-06 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2022-10-06 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-10-06 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2022-10-06 13:40:32 | UPDATED APPRAISAL PROVIDED SHOWS IMPROVEMENT VALUE AS | | | $800,000 FOR PROPERTY, THEREFORE, LANDSCAPE PERMIT IS | | | NO LONGER REQUIRED. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
ahamilto |
Date |
2022-05-31 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2022-05-31 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2022-05-31 16:31:12 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | THE VALUE OF CONSTRUCTION EXCEEDS 50% OF THE | | | IMPROVEMENT VALUE OF THE STRUCTURE, THEREFORE A | | | SEPERATE LANDSCAPE PERMIT IS REQUIRED AND MUST BE | | | SUBMITTED FOR ZONING APPROVAL TO MOVE FORWARD | | | | | | ALL LANDSCAPE, DRIVEWAY, MECHANICAL AND FENCES TO BE | | | APPROVED UNDER SEPARATE PERMITS. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|