Plan Review Details - Permit 22050183
Plan Review Stops For Permit 22050183
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-06-06 Cont ID  
Sent By pvalenti Date 2022-06-06 Time 16:20 Rev Time 0.00
Received By pvalenti Date 2022-06-06 Time 16:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-06-03 Cont ID  
Sent By pvalenti Date 2022-06-03 Time 06:17 Rev Time 0.00
Received By pvalenti Date 2022-06-03 Time 06:17 Sent To  
Notes
2022-06-03 06:21:06PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, PROVIDE ENGINEER'S CALCULATIONS AS TO
 THE WIND PRESSURES AND MECHANICAL FASTENING FOR THE
 TARCO BASE SHEET AS SELECTED FOR DECK TYPE 1, SYSTEM
 E(6) ON SHEET 12 OF NOA 21-1130.01
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-25 Cont ID  
Sent By jbrooks Date 2022-05-25 Time 11:01 Rev Time 0.00
Received By jbrooks Date 2022-05-25 Time 07:58 Sent To  
Notes
2022-05-25 11:02:08JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected].
  
 1. PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT
 APPROVALS/NOA'S FOR THE PROPOSED ROOF UNDERLAYMENT TO
 BE USED. INCLUDE COVER PAGE, EVALUATION REPORTS AND
 INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING
 2. FBC B 107.2.1. SUBMITTED MIAMI-DADE COUNTY NOA
 20-1124.07 HAS EXPIRED AND IS NO LONGER VALID. PLEASE
 PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT
 APPROVALS/NOA?S FOR THE PROPOSED ROOFING TILE ADHESIVE
 TO BE USED. INCLUDE COVER PAGE, EVALUATION REPORTS AND
 INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-06-06 Cont ID  
Sent By pvalenti Date 2022-06-06 Time 16:20 Rev Time 0.00
Received By pvalenti Date 2022-06-06 Time 06:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-03 Cont ID  
Sent By pvalenti Date 2022-06-03 Time 07:25 Rev Time 0.00
Received By pvalenti Date 2022-05-26 Time 15:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-25 Cont ID  
Sent By jbrooks Date 2022-05-25 Time 11:02 Rev Time 0.00
Received By jbrooks Date 2022-05-24 Time 08:41 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved