| Plan Review Stops For Permit 22050169 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-10-18 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-10-18 |
Time |
07:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-09-07 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-09-07 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2022-09-07 16:22:31 | 2ND ASBESTOS REVIEW: | | | | | | FAILED PLAN REVIEW: | | | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-08-04 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-08-04 |
Time |
07:21 |
Sent To |
|
|
| Notes |
| 2022-08-04 07:54:50 | ASBESTOS REVIEW: | | | | | | FAILED PLAN REVIEW: | | | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2023-01-09 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-01-09 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-01-09 |
Time |
06:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-12-30 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-12-30 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2022-12-30 07:35:40 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | 5TH BUILDING REVIEW DENIED: | | | | | | 1.) FBC B 107.2.1, THE FLOORING UNDERLAYMENT SUBMITTED | | | IS FOR THE AREAS TO BE TILED. PLEASE PROVIDE THE | | | UNDERLAYMENT PRODUCT THAT WILL BE USED FOR THE PROPOSED | | | WOOD FLOORING, AS INDICATED ON THE SCOPE OF WORK, | | | INCLUDING THE TESTING REPORTS FOR THE HARDWOOD FLOORING | | | AS PER THE NOTES BELOW: | | | | | | | | | PLEASE NOTE THAT TEST REPORTS ARE REQUIRED - | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2022-12-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-12-06 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-12-06 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2022-12-06 08:14:28 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 1.) FBC B 107.2.1, THE FLOORING UNDERLAYMENT SUBMITTED | | | IS FOR THE AREAS TO BE TILED. PLEASE PROVIDE THE | | | UNDERLAYMENT PRODUCT THAT WILL BE USED FOR THE PROPOSED | | | WOOD FLOORING, AS INDICATED ON THE SCOPE OF WORK, | | | INCLUDING THE TESTING REPORTS AS PER THE NOTES BELOW: | | | | | | | | | PLEASE NOTE THAT TEST REPORTS ARE REQUIRED - | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-10-18 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-10-18 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2022-10-18 08:51:22 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 1.) FBC B 107.2.1, THE FLOORING UNDERLAYMENT SUBMITTED | | | IS FOR THE AREAS TO BE TILED. PLEASE PROVIDE THE | | | UNDERLAYMENT PRODUCT THAT WILL BE USED FOR THE PROPOSED | | | WOOD FLOORING INCLUDING THE TESTING REPORTS AS PER THE | | | NOTES BELOW: | | | | | | | | | PLEASE NOTE THAT TEST REPORTS ARE REQUIRED - | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | | | | 2.) FBC B 107.2.1/FBC B 107.3.4.1, PROVIDE THE | | | HORIZONTAL SLIDING WINDOW PRODUCT APPROVAL TO CORRELATE | | | WITH PLAN SHEET A-2 OPENINGS B & E. THE WINDOW/DOOR | | | FLOOR PLAN NEEDS TO MATCH PLAN SHEET A-2 OR PLAN SHEET | | | A-2 NEEDS TO BE REVISED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-09-07 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-09-07 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2022-09-07 16:44:01 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 1.) FBC B 107.2.1, PROVIDE THE TESTING REPORTS THAT ARE | | | REQUIRED FOR THE NEW FLOORING/UNDERLAYMENT THAT IS TO | | | BE USED AS PER THE NOTES BELOW: | | | | | | | | | PLEASE NOTE THAT TEST REPORTS ARE REQUIRED - | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | | | | 2.) FBC B 107.2.1/FBC B 107.3.4.1, PROVIDE THE WINDOW, | | | DOOR, & MULLION PRODUCT APPROVALS TO CORRELATE WITH | | | PLAN SHEET A-2 OR LIST ON PLAN SHEET THE PRODUCT | | | APPROVALS THAT ARE TO BE DEFERRED. | | | | | | | | | | | | 4.) FBC EC C 103.1.1.1.2, THE OWNER OR THE OWNER'S | | | REPRESENTATIVE NEEDS TO SIGN THE SUBMITTED ENERGY | | | CALCULATIONS ON THE LINES THAT ARE FOR OWNER OR OWNER'S | | | REPRESENTATIVE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-08-04 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-08-04 |
Time |
07:22 |
Sent To |
|
|
| Notes |
| 2022-08-04 09:00:03 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 1.) FBC B 107.2.1, PROVIDE THE TESTING REPORTS THAT ARE | | | REQUIRED FOR THE NEW FLOORING/UNDERLAYMENT THAT IS TO | | | BE USED AS PER THE NOTES BELOW: | | | | | | TWO COMPLETE COLLATED SETS OF ALL DOCUMENTS REQUIRED | | | | | | PLEASE NOTE THAT TEST REPORTS ARE REQUIRED - | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. | | | THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM | | | CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED | | | GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT. | | | | | | C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | 2.) FBC B 107.2.1, PROVIDE THE WINDOW, DOOR, & MULLION | | | PRODUCT APPROVALS TO CORRELATE WITH PLAN SHEET A-2. | | | | | | 3.) FBC B 1603.1.4, PROVIDE THE SIGNED/SEALED DESIGN | | | WINDLOAD PRESSURES FOR EACH WINDOW AND DOOR OPENING. | | | | | | 4.) FBC EC C 103.1.1.1.2, THE OWNER OR THE OWNER'S | | | REPRESENTATIVE NEEDS TO SIGN THE SUBMITTED ENERGY | | | CALCULATIONS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-11-22 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-11-22 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2022-09-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-09-19 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-09-19 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2022-09-19 13:28:50 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | OUTLET SPACING ON WINDOW WALLS NEEDS TO BE PER 210.52 | | | | | | 210.52 (2) WALL SPACE. | | | | | | AS USED IN THIS SECTION, A WALL SPACE SHALL INCLUDE THE | | | FOLLOWING: | | | | | | (1) ANY SPACE 600 MM (2 FT) OR MORE IN WIDTH (INCLUDING | | | SPACE MEASURED AROUND CORNERS) AND UNBROKEN ALONG THE | | | FLOOR LINE BY DOORWAYS AND SIMILAR OPENINGS, | | | FIREPLACES, AND FIXED CABINETS THAT DO NOT HAVE | | | COUNTERTOPS OR SIMILAR WORK SURFACES | | | | | | (2) THE SPACE OCCUPIED BY FIXED PANELS IN WALLS, | | | EXCLUDING SLIDING PANELS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-26 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-26 |
Time |
16:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-07-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-07-20 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-07-20 |
Time |
07:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2022-11-08 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-11-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-11-08 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2022-11-08 11:33:52 | FIRE PROVISO: | | | | | | THE REMOVAL AND CONSTRUCTION OF NEW SPACES/AREAS | | | REQUIRE A REVIEW BY A FIRE SPRINKLER CONTRACTOR FOR | | | MODIFICATIONS. | | | | | | SPECIAL ATTENTION SHALL BE GIVEN TO THE EXTENSION OF | | | FIRE SPRINKLER HEAD COVERAGE WITHIN THE BALCONY | | | REMOVAL/LIVING ROOM EXTENSION. | | | | | | FIRE SPRINKLER PROTECTION SHALL BE EXTENDED INTO THIS | | | NEWLY OCCUPIED AREA. | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2022-09-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-09-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-09-14 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-08-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-08-24 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2022-08-24 11:14:39 | FIRE PROVISO: | | | | | | THE REMOVAL AND CONSTRUCTION OF NEW SPACES/AREAS | | | REQUIRE A REVIEW BY A FIRE SPRINKLER CONTRACTOR FOR | | | MODIFICATIONS. | | | | | | SPECIAL ATTENTION SHALL BE GIVEN TO THE EXTENSION OF | | | FIRE SPRINKLER HEAD COVERAGE WITHIN THE BALCONY | | | REMOVAL/LIVING ROOM EXTENSION. | | | | | | FIRE SPRINKLER PROTECTION SHALL BE EXTENDED INTO THIS | | | NEWLY OCCUPIED AREA. | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-07-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-07-11 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2022-07-11 15:50:21 | FIRE PROVISO: | | | THE REMOVAL AND CONSTRUCTION OF NEW SPACES/AREAS | | | REQUIRE A REVIEW BY A FIRE SPRINKLER CONTRACTOR FOR | | | MODIFICATIONS. | | | | | | SPECIAL ATTENTION SHALL BE GIVEN TO THE EXTENSION OF | | | FIRE SPRINKLER HEAD COVERAGE WITHIN THE BALCONY | | | REMOVAL/LIVING ROOM EXTENSION. | | | | | | FIRE SPRINKLER PROTECTION SHALL BE EXTENDED INTO THIS | | | NEWLY OCCUPIED AREA. | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2023-01-27 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-01-27 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-01-27 |
Time |
12:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-12-30 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-12-15 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-12-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-12-06 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-11-06 |
Time |
06:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-10-18 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-09-08 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-09-07 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-09-07 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-08-23 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-08-04 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-07-08 |
Time |
10:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2023-01-26 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-01-26 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-01-09 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2023-01-26 11:14:47 | 1/26/23 NO IMPACT FEES DUES, SEE UPLOADED EMAIL AO | | 2023-01-09 09:32:16 | 1/9/23 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-08-04 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-08-04 |
Time |
07:22 |
Sent To |
|
|
| Notes |
| 2022-08-04 07:48:54 | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-09-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-09-14 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-09-14 |
Time |
07:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-24 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-24 |
Time |
07:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-11 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-11 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-09-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-09-13 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-09-13 |
Time |
16:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-24 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-24 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-07-11 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-07-11 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-12-30 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-12-30 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-12-30 |
Time |
07:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2022-11-17 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-11-17 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-11-17 08:58:51 | SIGNATURE REVIEW FAILED - THE FILES SUBMITTED ARE NOT | | | ELECTRONICALLY SEALED | | | | | | * PROFESSIONAL ENGINEERS- ALL ELECTRONIC SUBMISSIONS | | | PREPARED BY AN ENGINEER MUST COMPLY WITH 61G15-23.001 | | | AND BE EITHER DIGITALLY SIGNED AND SEALED -OR- | | | ELECTRONICALLY SIGNED AND SEALED, IN ACCORDANCE WITH | | | 61G15-23.004 AND 61G15-23.005 F.A.C. RESPECTIVELY. | | | * ARCHITECTS- ALL ELECTRONIC SUBMISSIONS PREPARED BY AN | | | ARCHITECT MUST COMPLY WITH 61G1-16.004 F.A.C. AND BE | | | DIGITALLY SIGNED AND SEALED IN ACCORDANCE WITH | | | 61G1-16.005 F.A.C. | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-09-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-09-13 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-09-13 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-24 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-24 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2022-08-24 09:04:09 | 2ND SIGNATURE REVIEW | | | 8/24/22 | | | | | | RESULTS:DENIED. THIS IS THE 2ND REQUEST FOR DIGITALLY | | | SIGNED AND SEALED PLANS BY THE ENGINEER OF RECORD. THE | | | RESUBMITTED PLANS APPEAR TO BE SCANNED COPIES OF | | | DIGITALLY SIGNED SEALED PLANS. PLEASE NOTE THAT ALL | | | FL.. LICENSED ENGINEER'S PLAN AND DOCUMENTS TRANSMITTED | | | ELECTRONICALLY SHALL BEAR THE ENGINEER'S VERIFIABLE | | | DIGITAL SIGNATURES AND SEAL- FL. STATUTE 471.025 AND | | | FAC 61G15-23,005. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | 1ST REVIEW. | | | | | | PAGES ARE NOT ELECTRONICALLY SIGNED/SEALED | | | | | | ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR | | | ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH | | | 61G1-16 AND 61G15, F.A.C | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | ELECTRICAL SIGNATURE LOOKS LIKE A COPY FAILED JLEAHY | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-08-03 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-08-03 |
Time |
06:02 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-08-03 |
Time |
06:02 |
Sent To |
|
|
| Notes |
| 2022-08-03 06:04:03 | PAGES ARE NOT ELECTRONICALLY SIGNED/SEALED | | | | | | ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR | | | ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH | | | 61G1-16 AND 61G15, F.A.C | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | 2022-07-20 08:30:11 | ELECTRICAL SIGNATURE LOOKS LIKE A COPY FAILED JLEAHY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2023-01-27 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-01-27 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-01-27 |
Time |
12:17 |
Sent To |
|
|
| Notes |
| 2023-01-27 12:18:03 | APPROVED PER ANGELLA JONES VANN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2022-09-16 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-09-16 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-09-16 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2022-09-16 12:37:01 | 9/16/2022 | | | | | | APPROVAL PER ANGELLA VANN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-08-26 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-08-26 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2022-08-26 15:42:09 | 8/26/2022 | | | | | | APPROVED PER ANGELLA VANN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-03 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-08-03 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-08-03 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2022-08-03 08:51:12 | 8/3/2022 | | | APPROVED PER ANGELLA VANN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-07-28 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-07-28 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-07-28 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2022-07-28 15:12:41 | 7/28/2022 | | | FAIL | | | PLEASE PROVIDE THE TOTAL BUILDING FAR BOTH CURRENT AND | | | THE PROPOSED | | | | | | ARTICLE IV: SECTION 94-130 | | | D. | | | DEVELOPMENT INTENSITIES. IN THE CC-2 LAKEFRONT DISTRICT | | | THE DEVELOPMENT INTENSITY FOR RESIDENTIAL AND | | | NONRESIDENTIAL LAND USES SHALL BE REGULATED AS FOLLOWS: | | | THE DEVELOPMENT INTENSITY FOR NONRESIDENTIAL LAND USES | | | SHALL BE REGULATED BY THE FOLLOWING FLOOR AREA RATIO: | | | 2.5. | | | THE DEVELOPMENT INTENSITY FOR RESIDENTIAL LAND USES | | | SHALL BE REGULATED BY THE FOLLOWING FLOOR AREA RATIOS: | | | WITH LOT AREA CONTAINING 20,000 SQUARE FEET: 1.39. | | | WITH LOT AREA 80,000 OR GREATER SQUARE FEET: 2.42. | | | THE FLOOR AREA RATIO FOR LOTS CONTAINING MORE THAN | | | 20,000 SQUARE FEET BUT LESS THAN 80,000 SQUARE FEET | | | SHALL BE DETERMINED BY THE FOLLOWING FORMULA: LOT SIZE | | | (IN SQUARE FEET) MULTIPLIED BY 0.0000083 + 1.39. THE | | | FLOOR AREA RATIO CALCULATED USING THIS FORMULA SHALL | | | NOT EXCEED 2.42. | | | | | | | | | | | | | | | | | | ALEXIS SANGELEER | | | ASSOCIATE PLANNER | | | [email protected] |
|
|