Plan Review Details - Permit 22050169
Plan Review Stops For Permit 22050169
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2022-10-18 Cont ID  
Sent By pvalenti Date 2022-10-18 Time 07:39 Rev Time 0.00
Received By pvalenti Date 2022-10-18 Time 07:39 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-09-07 Cont ID  
Sent By pvalenti Date 2022-09-07 Time 16:20 Rev Time 0.00
Received By pvalenti Date 2022-09-07 Time 16:20 Sent To  
Notes
2022-09-07 16:22:312ND ASBESTOS REVIEW:
  
 FAILED PLAN REVIEW:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-08-04 Cont ID  
Sent By pvalenti Date 2022-08-04 Time 07:54 Rev Time 0.00
Received By pvalenti Date 2022-08-04 Time 07:21 Sent To  
Notes
2022-08-04 07:54:50ASBESTOS REVIEW:
  
 FAILED PLAN REVIEW:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2023-01-09 Cont ID  
Sent By pvalenti Date 2023-01-09 Time 06:56 Rev Time 0.00
Received By pvalenti Date 2023-01-09 Time 06:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2022-12-30 Cont ID  
Sent By pvalenti Date 2022-12-30 Time 07:26 Rev Time 0.00
Received By pvalenti Date 2022-12-30 Time 07:03 Sent To  
Notes
2022-12-30 07:35:40PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 5TH BUILDING REVIEW DENIED:
  
 1.) FBC B 107.2.1, THE FLOORING UNDERLAYMENT SUBMITTED
 IS FOR THE AREAS TO BE TILED. PLEASE PROVIDE THE
 UNDERLAYMENT PRODUCT THAT WILL BE USED FOR THE PROPOSED
 WOOD FLOORING, AS INDICATED ON THE SCOPE OF WORK,
 INCLUDING THE TESTING REPORTS FOR THE HARDWOOD FLOORING
 AS PER THE NOTES BELOW:
  
  
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2022-12-06 Cont ID  
Sent By pvalenti Date 2022-12-06 Time 08:13 Rev Time 0.00
Received By pvalenti Date 2022-12-06 Time 07:28 Sent To  
Notes
2022-12-06 08:14:28PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1.) FBC B 107.2.1, THE FLOORING UNDERLAYMENT SUBMITTED
 IS FOR THE AREAS TO BE TILED. PLEASE PROVIDE THE
 UNDERLAYMENT PRODUCT THAT WILL BE USED FOR THE PROPOSED
 WOOD FLOORING, AS INDICATED ON THE SCOPE OF WORK,
 INCLUDING THE TESTING REPORTS AS PER THE NOTES BELOW:
  
  
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-10-18 Cont ID  
Sent By pvalenti Date 2022-10-18 Time 08:50 Rev Time 0.00
Received By pvalenti Date 2022-10-18 Time 07:53 Sent To  
Notes
2022-10-18 08:51:22PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1.) FBC B 107.2.1, THE FLOORING UNDERLAYMENT SUBMITTED
 IS FOR THE AREAS TO BE TILED. PLEASE PROVIDE THE
 UNDERLAYMENT PRODUCT THAT WILL BE USED FOR THE PROPOSED
 WOOD FLOORING INCLUDING THE TESTING REPORTS AS PER THE
 NOTES BELOW:
  
  
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
  
  
 2.) FBC B 107.2.1/FBC B 107.3.4.1, PROVIDE THE
 HORIZONTAL SLIDING WINDOW PRODUCT APPROVAL TO CORRELATE
 WITH PLAN SHEET A-2 OPENINGS B & E. THE WINDOW/DOOR
 FLOOR PLAN NEEDS TO MATCH PLAN SHEET A-2 OR PLAN SHEET
 A-2 NEEDS TO BE REVISED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-09-07 Cont ID  
Sent By pvalenti Date 2022-09-07 Time 16:37 Rev Time 0.00
Received By pvalenti Date 2022-09-07 Time 16:37 Sent To  
Notes
2022-09-07 16:44:01PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1.) FBC B 107.2.1, PROVIDE THE TESTING REPORTS THAT ARE
 REQUIRED FOR THE NEW FLOORING/UNDERLAYMENT THAT IS TO
 BE USED AS PER THE NOTES BELOW:
  
  
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
  
  
 2.) FBC B 107.2.1/FBC B 107.3.4.1, PROVIDE THE WINDOW,
 DOOR, & MULLION PRODUCT APPROVALS TO CORRELATE WITH
 PLAN SHEET A-2 OR LIST ON PLAN SHEET THE PRODUCT
 APPROVALS THAT ARE TO BE DEFERRED.
  
  
  
 4.) FBC EC C 103.1.1.1.2, THE OWNER OR THE OWNER'S
 REPRESENTATIVE NEEDS TO SIGN THE SUBMITTED ENERGY
 CALCULATIONS ON THE LINES THAT ARE FOR OWNER OR OWNER'S
 REPRESENTATIVE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-08-04 Cont ID  
Sent By pvalenti Date 2022-08-04 Time 08:58 Rev Time 0.00
Received By pvalenti Date 2022-08-04 Time 07:22 Sent To  
Notes
2022-08-04 09:00:03PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1.) FBC B 107.2.1, PROVIDE THE TESTING REPORTS THAT ARE
 REQUIRED FOR THE NEW FLOORING/UNDERLAYMENT THAT IS TO
 BE USED AS PER THE NOTES BELOW:
  
 TWO COMPLETE COLLATED SETS OF ALL DOCUMENTS REQUIRED
  
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC B 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 THE TEST REPORT CANNOT INCLUDE A DROPPED GYPSUM
 CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 B. FBC B 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. THE TEST REPORT CANNOT INCLUDE A DROPPED
 GYPSUM CEILING. PROVIDE A COPY OF THE TEST REPORT.
  
 C. FBC B 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
  
 2.) FBC B 107.2.1, PROVIDE THE WINDOW, DOOR, & MULLION
 PRODUCT APPROVALS TO CORRELATE WITH PLAN SHEET A-2.
  
 3.) FBC B 1603.1.4, PROVIDE THE SIGNED/SEALED DESIGN
 WINDLOAD PRESSURES FOR EACH WINDOW AND DOOR OPENING.
  
 4.) FBC EC C 103.1.1.1.2, THE OWNER OR THE OWNER'S
 REPRESENTATIVE NEEDS TO SIGN THE SUBMITTED ENERGY
 CALCULATIONS.
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2022-11-22 Cont ID  
Sent By jleahy Date 2022-11-22 Time 08:14 Rev Time 0.00
Received By jleahy Date 2022-11-22 Time 08:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2022-09-19 Cont ID  
Sent By jleahy Date 2022-09-19 Time 13:22 Rev Time 0.00
Received By jleahy Date 2022-09-19 Time 13:19 Sent To  
Notes
2022-09-19 13:28:50FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 OUTLET SPACING ON WINDOW WALLS NEEDS TO BE PER 210.52
  
 210.52 (2) WALL SPACE.
  
 AS USED IN THIS SECTION, A WALL SPACE SHALL INCLUDE THE
 FOLLOWING:
  
 (1) ANY SPACE 600 MM (2 FT) OR MORE IN WIDTH (INCLUDING
 SPACE MEASURED AROUND CORNERS) AND UNBROKEN ALONG THE
 FLOOR LINE BY DOORWAYS AND SIMILAR OPENINGS,
 FIREPLACES, AND FIXED CABINETS THAT DO NOT HAVE
 COUNTERTOPS OR SIMILAR WORK SURFACES
  
 (2) THE SPACE OCCUPIED BY FIXED PANELS IN WALLS,
 EXCLUDING SLIDING PANELS

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-08-26 Cont ID  
Sent By jleahy Date 2022-08-26 Time 16:21 Rev Time 0.00
Received By jleahy Date 2022-08-26 Time 16:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-07-20 Cont ID  
Sent By jleahy Date 2022-07-20 Time 08:03 Rev Time 0.00
Received By jleahy Date 2022-07-20 Time 07:18 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2022-11-08 Cont ID  
Sent By pleduc Date 2022-11-08 Time   Rev Time 0.00
Received By pleduc Date 2022-11-08 Time 11:32 Sent To  
Notes
2022-11-08 11:33:52FIRE PROVISO:
  
 THE REMOVAL AND CONSTRUCTION OF NEW SPACES/AREAS
 REQUIRE A REVIEW BY A FIRE SPRINKLER CONTRACTOR FOR
 MODIFICATIONS.
  
 SPECIAL ATTENTION SHALL BE GIVEN TO THE EXTENSION OF
 FIRE SPRINKLER HEAD COVERAGE WITHIN THE BALCONY
 REMOVAL/LIVING ROOM EXTENSION.
  
 FIRE SPRINKLER PROTECTION SHALL BE EXTENDED INTO THIS
 NEWLY OCCUPIED AREA.
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-09-14 Cont ID  
Sent By pleduc Date 2022-09-14 Time   Rev Time 0.00
Received By pleduc Date 2022-09-14 Time 13:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-08-24 Cont ID  
Sent By pleduc Date 2022-08-24 Time   Rev Time 0.00
Received By pleduc Date 2022-08-24 Time 10:59 Sent To  
Notes
2022-08-24 11:14:39FIRE PROVISO:
  
 THE REMOVAL AND CONSTRUCTION OF NEW SPACES/AREAS
 REQUIRE A REVIEW BY A FIRE SPRINKLER CONTRACTOR FOR
 MODIFICATIONS.
  
 SPECIAL ATTENTION SHALL BE GIVEN TO THE EXTENSION OF
 FIRE SPRINKLER HEAD COVERAGE WITHIN THE BALCONY
 REMOVAL/LIVING ROOM EXTENSION.
  
 FIRE SPRINKLER PROTECTION SHALL BE EXTENDED INTO THIS
 NEWLY OCCUPIED AREA.
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-07-11 Cont ID  
Sent By pleduc Date 2022-07-11 Time   Rev Time 0.00
Received By pleduc Date 2022-07-11 Time 15:25 Sent To  
Notes
2022-07-11 15:50:21FIRE PROVISO:
 THE REMOVAL AND CONSTRUCTION OF NEW SPACES/AREAS
 REQUIRE A REVIEW BY A FIRE SPRINKLER CONTRACTOR FOR
 MODIFICATIONS.
  
 SPECIAL ATTENTION SHALL BE GIVEN TO THE EXTENSION OF
 FIRE SPRINKLER HEAD COVERAGE WITHIN THE BALCONY
 REMOVAL/LIVING ROOM EXTENSION.
  
 FIRE SPRINKLER PROTECTION SHALL BE EXTENDED INTO THIS
 NEWLY OCCUPIED AREA.
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2023-01-27 Cont ID  
Sent By pvalenti Date 2023-01-27 Time 12:18 Rev Time 0.00
Received By asangele Date 2023-01-27 Time 12:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-12-30 Cont ID  
Sent By pvalenti Date 2022-12-30 Time 08:09 Rev Time 0.00
Received By pvalenti Date 2022-12-15 Time 07:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-12-06 Cont ID  
Sent By pvalenti Date 2022-12-06 Time 08:18 Rev Time 0.00
Received By pvalenti Date 2022-11-06 Time 06:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-10-18 Cont ID  
Sent By pvalenti Date 2022-10-18 Time 09:06 Rev Time 0.00
Received By pvalenti Date 2022-09-08 Time 09:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-09-07 Cont ID  
Sent By pvalenti Date 2022-09-07 Time 16:44 Rev Time 0.00
Received By pvalenti Date 2022-08-23 Time 16:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-08-04 Cont ID  
Sent By pvalenti Date 2022-08-04 Time 09:47 Rev Time 0.00
Received By pvalenti Date 2022-07-08 Time 10:53 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-01-26 Cont ID  
Sent By aoliver Date 2023-01-26 Time 11:46 Rev Time 0.00
Received By aoliver Date 2023-01-09 Time 09:32 Sent To  
Notes
2023-01-26 11:14:471/26/23 NO IMPACT FEES DUES, SEE UPLOADED EMAIL AO
2023-01-09 09:32:161/9/23 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-08-04 Cont ID  
Sent By pvalenti Date 2022-08-04 Time 07:46 Rev Time 0.00
Received By pvalenti Date 2022-08-04 Time 07:22 Sent To  
Notes
2022-08-04 07:48:54IMPACT FEES - DIGITAL SUBMITTALS
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-09-14 Cont ID  
Sent By medwards Date 2022-09-14 Time 07:45 Rev Time 0.00
Received By medwards Date 2022-09-14 Time 07:45 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-08-24 Cont ID  
Sent By medwards Date 2022-08-24 Time 07:28 Rev Time 0.00
Received By medwards Date 2022-08-24 Time 07:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-07-11 Cont ID  
Sent By medwards Date 2022-07-11 Time 11:02 Rev Time 0.00
Received By medwards Date 2022-07-11 Time 11:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-09-13 Cont ID  
Sent By ccole Date 2022-09-13 Time 16:03 Rev Time 0.00
Received By ccole Date 2022-09-13 Time 16:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-08-24 Cont ID  
Sent By ccole Date 2022-08-24 Time 08:49 Rev Time 0.00
Received By ccole Date 2022-08-24 Time 08:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-07-11 Cont ID  
Sent By ccole Date 2022-07-11 Time 11:07 Rev Time 0.00
Received By ccole Date 2022-07-11 Time 10:33 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2022-12-30 Cont ID  
Sent By pvalenti Date 2022-12-30 Time 08:09 Rev Time 0.00
Received By pvalenti Date 2022-12-30 Time 07:03 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2022-11-17 Cont ID  
Sent By rwbrown Date 2022-11-17 Time 08:58 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
2022-11-17 08:58:51SIGNATURE REVIEW FAILED - THE FILES SUBMITTED ARE NOT
 ELECTRONICALLY SEALED
  
 * PROFESSIONAL ENGINEERS- ALL ELECTRONIC SUBMISSIONS
 PREPARED BY AN ENGINEER MUST COMPLY WITH 61G15-23.001
 AND BE EITHER DIGITALLY SIGNED AND SEALED -OR-
 ELECTRONICALLY SIGNED AND SEALED, IN ACCORDANCE WITH
 61G15-23.004 AND 61G15-23.005 F.A.C. RESPECTIVELY.
 * ARCHITECTS- ALL ELECTRONIC SUBMISSIONS PREPARED BY AN
 ARCHITECT MUST COMPLY WITH 61G1-16.004 F.A.C. AND BE
 DIGITALLY SIGNED AND SEALED IN ACCORDANCE WITH
 61G1-16.005 F.A.C.
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-09-13 Cont ID  
Sent By ccole Date 2022-09-13 Time 16:03 Rev Time 0.00
Received By ccole Date 2022-09-13 Time 16:03 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-08-24 Cont ID  
Sent By ccole Date 2022-08-24 Time 08:52 Rev Time 0.00
Received By ccole Date 2022-08-24 Time 08:48 Sent To  
Notes
2022-08-24 09:04:092ND SIGNATURE REVIEW
 8/24/22
  
 RESULTS:DENIED. THIS IS THE 2ND REQUEST FOR DIGITALLY
 SIGNED AND SEALED PLANS BY THE ENGINEER OF RECORD. THE
 RESUBMITTED PLANS APPEAR TO BE SCANNED COPIES OF
 DIGITALLY SIGNED SEALED PLANS. PLEASE NOTE THAT ALL
 FL.. LICENSED ENGINEER'S PLAN AND DOCUMENTS TRANSMITTED
 ELECTRONICALLY SHALL BEAR THE ENGINEER'S VERIFIABLE
 DIGITAL SIGNATURES AND SEAL- FL. STATUTE 471.025 AND
 FAC 61G15-23,005.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6719
 [email protected]
  
  
 1ST REVIEW.
  
 PAGES ARE NOT ELECTRONICALLY SIGNED/SEALED
  
 ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR
 ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH
 61G1-16 AND 61G15, F.A.C
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
 ELECTRICAL SIGNATURE LOOKS LIKE A COPY FAILED JLEAHY
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-08-03 Cont ID  
Sent By rwbrown Date 2022-08-03 Time 06:02 Rev Time 0.00
Received By rwbrown Date 2022-08-03 Time 06:02 Sent To  
Notes
2022-08-03 06:04:03PAGES ARE NOT ELECTRONICALLY SIGNED/SEALED
  
 ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR
 ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH
 61G1-16 AND 61G15, F.A.C
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
2022-07-20 08:30:11ELECTRICAL SIGNATURE LOOKS LIKE A COPY FAILED JLEAHY

Review Stop Z ZONING
Rev No 5 Status P Date 2023-01-27 Cont ID  
Sent By asangele Date 2023-01-27 Time 12:17 Rev Time 0.00
Received By asangele Date 2023-01-27 Time 12:17 Sent To  
Notes
2023-01-27 12:18:03APPROVED PER ANGELLA JONES VANN

Review Stop Z ZONING
Rev No 4 Status P Date 2022-09-16 Cont ID  
Sent By asangele Date 2022-09-16 Time 12:36 Rev Time 0.00
Received By asangele Date 2022-09-16 Time 12:36 Sent To  
Notes
2022-09-16 12:37:019/16/2022
  
 APPROVAL PER ANGELLA VANN

Review Stop Z ZONING
Rev No 3 Status P Date 2022-08-26 Cont ID  
Sent By asangele Date 2022-08-26 Time 15:41 Rev Time 0.00
Received By asangele Date 2022-08-26 Time 15:41 Sent To  
Notes
2022-08-26 15:42:098/26/2022
  
 APPROVED PER ANGELLA VANN

Review Stop Z ZONING
Rev No 2 Status P Date 2022-08-03 Cont ID  
Sent By asangele Date 2022-08-03 Time 08:50 Rev Time 0.00
Received By asangele Date 2022-08-03 Time 08:50 Sent To  
Notes
2022-08-03 08:51:128/3/2022
 APPROVED PER ANGELLA VANN

Review Stop Z ZONING
Rev No 1 Status F Date 2022-07-28 Cont ID  
Sent By asangele Date 2022-07-28 Time 15:06 Rev Time 0.00
Received By asangele Date 2022-07-28 Time 15:06 Sent To  
Notes
2022-07-28 15:12:417/28/2022
 FAIL
 PLEASE PROVIDE THE TOTAL BUILDING FAR BOTH CURRENT AND
 THE PROPOSED
  
 ARTICLE IV: SECTION 94-130
 D.
 DEVELOPMENT INTENSITIES. IN THE CC-2 LAKEFRONT DISTRICT
 THE DEVELOPMENT INTENSITY FOR RESIDENTIAL AND
 NONRESIDENTIAL LAND USES SHALL BE REGULATED AS FOLLOWS:
 THE DEVELOPMENT INTENSITY FOR NONRESIDENTIAL LAND USES
 SHALL BE REGULATED BY THE FOLLOWING FLOOR AREA RATIO:
 2.5.
 THE DEVELOPMENT INTENSITY FOR RESIDENTIAL LAND USES
 SHALL BE REGULATED BY THE FOLLOWING FLOOR AREA RATIOS:
 WITH LOT AREA CONTAINING 20,000 SQUARE FEET: 1.39.
 WITH LOT AREA 80,000 OR GREATER SQUARE FEET: 2.42.
 THE FLOOR AREA RATIO FOR LOTS CONTAINING MORE THAN
 20,000 SQUARE FEET BUT LESS THAN 80,000 SQUARE FEET
 SHALL BE DETERMINED BY THE FOLLOWING FORMULA: LOT SIZE
 (IN SQUARE FEET) MULTIPLIED BY 0.0000083 + 1.39. THE
 FLOOR AREA RATIO CALCULATED USING THIS FORMULA SHALL
 NOT EXCEED 2.42.
  
  
  
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]