| Plan Review Stops For Permit 22050161 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-02-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-22 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-02-22 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-11-02 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-11-02 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-11-02 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2022-11-02 10:27:33 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 2.) FBC B 107.2.1, PLAN SHEET A-4 (PORTICO DETAIL) IS | | | NOT CLEAR FOR THE FOOTINGS AS THE FOOTING WIDTH APPEARS | | | TO SHOW TWO DIFFERENT WIDTH MEASUREMENTS OF 18" TYPICAL | | | NOTE AND 22" MEASUREMENT INDICATED. PLEASE CORRECT ON | | | PLAN. | | | 3.) FBC B 107.2.1, PLAN SHEET A-4 (PORTICO COLUMNS | | | DETAIL) IS NOT CLEAR AS THESE COLUMNS ARE LOAD BEARING, | | | PLEASE PROVIDE STRUCTURAL DETAIL. | | | 7.) FBC B 107.2.1/FBC B 107.3.4.1/FBC R TABLE | | | 301.2.1.3, PLAN SHEET A-1 (PRODUCT APPROVALS), PLEASE | | | ADD TO TITLE OF PRODUCT APPROVAL SECTION A NOTE | | | INDICATING THAT THESE ARE TO BE DEFERRED SUBMITTALS AND | | | CORRECT THE WINDLOAD SPEEDS FROM 150 VULT & 116 VASD TO | | | 170 VULT & 132 VASD. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-06-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-25 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-25 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2022-06-25 12:16:23 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 1.) FBC B 107.2.6, PROVIDE A SITE-PLAN THAT INCLUDES, | | | FOR PROPOSED NEW WORK, DISTANCES TO LOT LINES. | | | 2.) FBC B 107.2.1, PROVIDE CLARITY FOR THE FOOTING | | | DETAILS THAT ARE TO BE USED AT EACH LOCATION. FOR | | | EXAMPLE, IT IS NOT CLEAR AS TO WHICH FOOTING WILL BE | | | USED AT THE NEW FRONT "PORTICO" AREA. | | | 3.) FBC B 107.2.1, PROVIDE DETAILS FOR THE FRONT | | | COLUMNS OF THE PORTICO. | | | 4.) FBC B 107.2.1, PLEASE CLARIFY OR PROVIDE WHAT | | | APPEARS TO BE MISSING STRUCTURAL PLAN SHEETS AS PLAN | | | SHEET A-2 HAS REFERENCING "SLAB EDGE DETAILS" | | | IDENTIFIED AS A/S-1 & B/S-1. | | | 5.) FBC B 107.2.1, PROVIDE OPENING IDENTIFICATION | | | NUMBERS ON PROPOSED FLOOR PLAN AND ELEVATION SHEETS TO | | | MATCH WITH THE PRODUCT APPROVAL SCHEDULE SHOWN ON PLAN | | | SHEET A-1. | | | 6.) FBC R 905.1.1.1, PROVIDE THE METHOD OF ROOFING | | | UNDERLAYMENT FOR SHINGLES ( SELF ADHERING BITUMEN | | | UNDERLAYMENT, 4" WIDE STRIPS, FLASHING TAPE, OR | | | 2-LAYERS OF FELT) THAT WILL MEET THE CODE REQUIREMENTS | | | IN ADDITION TO THE FELT PAPER THAT IS NOTED UNDER THE | | | ROOFING ASSEMBLY DETAILS ON PLAN SHEET A-14. | | | 7.) FBC B 107.2.1/FBC B 107.3.4.1, SUBMIT ALL OF THE | | | PRODUCT APPROVALS(WITH ENGINEER OF RECORD REVIEW STAMP) | | | TO BE USED INCLUDING ALL ROOFING MATERIALS. IF THE | | | PRODUCT APPROVALS ARE TO BE DEFERRED, PLEASE INCLUDE | | | ALL ON PLAN SHEET. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-01-30 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-30 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-30 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-10-13 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-13 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-13 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-06-22 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-22 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-22 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2022-06-22 15:29:14 | ELECTRIC REVIEW FAILED | | | 1) ELECTRIC PANEL IS DETAILED INSIDE A BATHROOM NOT IN | | | COMPLIANCE WITH NEC 240.24 (E). PLEASE RELOCATE IN A | | | NEC COMPLIANT LOCATION. | | | 2) NO OUTDOOR RECEPTACLES ARE DETAILED AT FRONT AND | | | REAR PATIOS AS REQUIRED PER NEC 210.52 (E) (1) AND (3) | | | 3) NO SMOKE ALARM IS DETAILED OUTSIDE MASTER BEDROOM AS | | | REQUIRED PER FBC R314.3 | | | $) RECEPTACLE IS DETAILED IN MASTER BATHROOM SHOWER NOT | | | IN COMPLIANCE WITH NEC 406.9(C) PLEASE REMOVE AS | | | APPLICABLE | | | 6) NO RECEPTACLE IS DETAILED AT POWDER ROOM SINK BASIN | | | AS REQUIRED PER NEC 210.52 (D) PLEASE CORRECT AS | | | APPLICABLE | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-03-06 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-03-01 |
Time |
10:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-02-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-02-22 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-01-27 |
Time |
12:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-11-02 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-11-02 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-10-04 |
Time |
11:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-06-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-25 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-07 |
Time |
13:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2023-04-06 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-04-06 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-03-16 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2023-04-04 16:00:32 | RECEIPT MU-2023-012457 - $1897.60 PAID | | 2023-03-16 14:48:00 | 3/16/23 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-06-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-25 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-25 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2022-06-25 11:33:48 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2023-03-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-02 |
Time |
06:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-02 |
Time |
06:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2023-01-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-30 |
Time |
06:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-30 |
Time |
06:34 |
Sent To |
|
|
| Notes |
| 2023-01-30 06:34:42 | 3RD REVIEW FMC | | | PERMIT: 22050161 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | PLEASE SUBMIT WHAT I HAVE ASKED FOR IN THE LAST 2 | | | REVIEW CYCLE. I AM STILL WAITING FOR THE DUCT SIZES, | | | GRILLE SIZES AND CFM???S FOR EACH GRILLE. FBC 107.3.5 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-05 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-05 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2022-10-05 10:24:25 | THE MECHANICAL EQUIPMENT SIZE HAS BEEN CORRECTED. I DO | | | NOT SEE THE LOCATION OF THE AHU OR THE DUCT SIZES WITH | | | THE CFM'S REQUIRED AT EACH GRILLE. | | | PLEASE ADDRESS COMMENT 2 OF PREVIOUS REVIEW COMMENTS. | | | | | | 2) REVISE THE MECHANICAL DRAWING TO IDENTIFY THE AHU | | | LOCATION, PROVIDE DUCT SIZES ON ALL DUCTWORK, PROVIDE | | | CFM?S AND GRILLE SIZES FOR ALL GRILLES. FBC 107.2.1 | | | THE MECHANICAL DRAWING DOES NOT HAVE JOSEPH SIMMONS | | | DIGITAL SIGNATURE. PROVIDE THE ORIGIMAL DIGITAL | | | SIGNATURE FROM THE DESIGNER. 471/481 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-06-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-06-11 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-06-11 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2022-06-11 10:44:00 | 1ST REVIEW FMC | | | PERMIT: 22050161 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE MECHANICAL EQUIPMENT SIZING CALCULATIONS CALL | | | FOR A 3.5 TON SYSTEM BUT THE MECHANICAL DRAWING | | | SPECIFIES A 5 TON SYSTEM. THE 2 NEED TO BE CONSISTENT. | | | | | | R403.7.1.2.1 HEAT PUMPS. HEAT PUMP SIZING SHALL BE | | | BASED ON THE COOLING REQUIREMENTS AS CALCULATED | | | ACCORDING TO SECTION R403.7.1.1, AND THE HEAT PUMP | | | TOTAL COOLING CAPACITY SHALL NOT BE MORE THAN 1.15 | | | TIMES GREATER THAN THE DESIGN COOLING LOAD EVEN IF THE | | | DESIGN HEATING LOAD IS 1.15 TIMES GREATER THAN THE | | | DESIGN COOLING LOAD. | | | | | | 2) REVISE THE MECHANICAL DRAWING TO IDENTIFY THE AHU | | | LOCATION, PROVIDE DUCT SIZES ON ALL DUCTWORK, PROVIDE | | | CFM?S AND GRILLE SIZES FOR ALL GRILLES. FBC 107.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2023-01-30 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-30 |
Time |
06:08 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-30 |
Time |
06:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-10-05 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-10-05 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-10-05 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2022-10-05 11:41:38 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FRC P3101 - YOUR WASTE AND VENT SYSTEM IS NOT | | | TYPICAL. SEVERAL ITEMS DO NOT MEET CODE. THE SHOWER IN | | | THE MASTER BATH AND THE KING SWEET BATH SHOWER ARE NOT | | | VENTED (P3101.2.1), THE WATER CLOSET IN THE MASTER BATH | | | SHOWS THE TRAP (AND A WATER CLOSET TYPICALLY DOES NOT | | | SHOW THE TRAP ON THE ISO) WITH THE VENT ON THE HIGH | | | SIDE OF THE TRAP, THE HALL BATH WATER CLOSET AND THE | | | HALL BATH SHOWER SHOWS AN ILLEGAL DRY VENT (THE VENT | | | CANNOT BE HORIZONTAL UNTIL IT IS 6" ABOVE THE FLOOD RIM | | | OF THE FIXTURE SERVED - P3104.4). PLEASE RECONFIGURE | | | THE DRAIN AND VENT SYSTEM TO SHOW A COMPLIANT SYSTEM. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-06-08 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-06-08 |
Time |
06:52 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-06-08 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2022-06-08 06:52:20 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMENDS 107.3.5.3 (12) - PLEASE PROVIDE A | | | PLUMBING RISER SHOWING THE DRAIN, WASTE, AND VENT | | | CONFIGURATION. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-11-02 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-11-02 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-11-02 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2022-11-02 10:33:50 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | ROOFING REVIEW APPROVED | | | | | | NOTE: ROOFING SUB-PERMIT MUST BE APPROVED PRIOR TO | | | ROOFING WORK. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-06-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-25 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-25 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2022-06-25 12:20:43 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | ROOFING REVIEW DENIED: | | | | | | 1.) FBC R 905.1.1.1, PROVIDE THE METHOD OF ROOFING | | | UNDERLAYMENT FOR SHINGLES ( SELF ADHERING BITUMEN | | | UNDERLAYMENT, 4" WIDE STRIPS, FLASHING TAPE, OR | | | 2-LAYERS OF FELT) THAT WILL MEET THE CODE REQUIREMENTS | | | IN ADDITION TO THE FELT PAPER THAT IS NOTED UNDER THE | | | ROOFING ASSEMBLY DETAILS ON PLAN SHEET A-14. | | | | | | 2.) FBC B 107.2.1/FBC B 107.3.4.1, SUBMIT ALL OF THE | | | PRODUCT APPROVALS FOR ROOFING MATERIAL TO BE USED (WITH | | | ENGINEER OF RECORD REVIEW STAMP). IF THE PRODUCT | | | APPROVALS ARE TO BE DEFERRED, PLEASE INCLUDE ALL ON | | | PLAN SHEET. | | | | | | NOTE: THE ROOFING SUB-PERMIT MUST BE OBTAINED PRIOR TO | | | ANY ROOF WORK. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-03-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-02 |
Time |
06:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-02 |
Time |
06:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-01-30 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-01-30 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-01-30 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2023-01-27 12:37:14 | COMBINED DIGITALLY SIGNED FILE IN SIGNATURES FOLDER |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-10-13 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-10-13 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-10-13 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2022-10-13 15:02:45 | SIGNATURE REVIEW FAILED | | | | | | DIGITAL SIGNATURES ON ALL DRAWINGS/PLANS ARE NOT ABLE | | | TO BE VERIFIED USING BLUEBEAM OR ADOBE SOFTWARE. PLEASE | | | CORRECT AS OUTLINED BELOW. | | | | | | FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF | | | RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | DIGITALLY SEALED AND SIGNED. | | | | | | PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS | | | FOLLOWING PROJECTDOX INSTRUCTIONS | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-06-25 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-25 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-25 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2022-06-25 11:02:41 | SIGNATURE REVIEW DENIED: | | | | | | ALL PLAN SHEETS ARE LACKING THE THIRD PARTY | | | SIGNATURE/SEAL. | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | | VERIFIED) PLAN: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | | | | | | | 2022-06-11 10:45:03 | ENGINEERS SEAL AND SIGNATURE IS A COPY OF A WET SEAL. | | | DIGITAL SIGNATURE WILL BE REQUIRED. ME |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2023-03-06 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-03-06 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-03-06 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-02-07 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-02-07 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2023-02-07 13:34:34 | LANDSCAPE PERMIT STILPL REQUIRED, PLEASE APPLY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-10-18 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-10-18 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2022-10-18 12:58:39 | 10/18/2022 FAILED | | | | | | SEPERATE PERMIT REQUIRED FOR LANDSCAPING, | | | | | | PLEASE SHOW THE SETBACK FROM THE PROPOSED ENTRY WAY TO | | | THE LOT LINE ALONG ERIE RD, A MINIMUM OF 25 IS REQUIRED | | | AS THIS SEEMS TO BE THE NARROWEST STREET AND CONSIDERED | | | THE REQUIERED FRONT SETBACK. | | | | | | PROPOSED BEDROOM IS NOT CONSISTANT WITH NOTED SETBACK | | | ON THE SURVEY AND SITE PLAN, PLEASE CLEARIFY IF SETBACK | | | IS 18 FEET OR 19 FEET | | | | | | **** REVIEWD BY **** | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-06-14 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-06-14 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-06-14 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2022-06-14 10:15:06 | 6/14/2022 FAILED | | | | | | PLEASE PROVIDE THE SETBACKS OF THE PROJECT ON THE SITE | | | PLAN | | | | | | THE VALUE OF THE CONSTRUCTION ($150,000) EXCEEDS 50% OF | | | THE STRUCTURE'S VALUE ($120,605) ACCORDING TO THE | | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | | TO SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE | | | IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | | ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO | | | ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN | | | DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE | | | PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO | | | ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS | | | PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION | | | PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE | | | SITE INTO CONFORMITY | | | | | | PLEASE APPLY FOR THE LANDSCAPE PERMIT TO ALLOW STAFF TO | | | MOVE THE PERMIT FORWARD | | | | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | |
|
|