| 2022-05-05 13:21:56 | JONATHAN BROOKS JR. |
| | BUILDING PLANS EXAMINER |
| | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| | PHONE (561) 805-6656 |
| | EMAIL: [email protected] |
| | |
| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR EMAIL [email protected]. |
| | |
| | 1. FBC B 107.2.1. SUBMITTED FLORIDA DBPR PRODUCT |
| | APPROVAL FL16709-R9 HAS BEEN REVISED TO FL16709-R10. |
| | PLEASE PROVIDE THE FOLLOWING: INCLUDE COVER PAGE, |
| | EVALUATION REPORT PAGES 1-4 AND INSTALLATION |
| | INSTRUCTIONS FOR SYSTEM USED. ALL APPLICABLE DETAILS |
| | AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE |
| | PRODUCT APPROVAL DRAWINGS. |
| | 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT |
| | APPROVAL FL16709-R9 SELECTED SYSTEM NO W-5; EXPOSURE |
| | (C; ENCLOSURE (ENCLOSED); ROOF HEIGHT (H < 15); |
| | ULTIMATE WIND SPEED 180 IS NOT CORRECT. THE CORRECT |
| | EXPOSURE CATEGORY FOR THE LISTED ADDRESS IS EXPOSURE D, |
| | WIND SPEED IS 170 MPH. PLEASE SELECT THE CORRECT |
| | OPTIONS. PRODUCT APPROVAL FL16709-R9 WILL NOT SATISFY |
| | EXPOSURE CATEGORY D ENCLOSED AREAS WITHOUT USING |
| | INSULATION OR PROVIDING ENGINEERED ENHANCED NAILING. |
| | 3. FBC R 905.1.1 ASPHALT SHINGLE, METAL, MINERAL |
| | SURFACE, SLATE AND SLATE-TYPE ROOFING MUST COMPLY WITH |
| | NEW 2020 BUILDING CODE UNDERLAYMENT REQUIREMENTS. |
| | PROVIDE METHOD OF COMPLIANCE. (IF USING DOUBLE 30# FELT |
| | INDICATE ON ROOF DRAWING/SKETCH). |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. |
| | |