Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2022-05-12 Cont ID  
Sent By rmcphers Date 2022-05-12 Time 15:56 Rev Time 0.00
Received By rmcphers Date 2022-05-12 Time 15:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-06-06 Cont ID  
Sent By rmcphers Date 2022-06-06 Time 11:14 Rev Time 0.00
Received By rmcphers Date 2022-06-06 Time 11:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-12 Cont ID  
Sent By rmcphers Date 2022-05-12 Time 15:56 Rev Time 0.00
Received By rmcphers Date 2022-05-12 Time 15:56 Sent To  
Notes
2022-05-12 16:06:59OFFICE RENOVATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE A NOTE ON THE DRAWINGS REFERRING TO
 THE FIRE CLASSIFICATION FOR THE FLOOR, WALL AND CEILING
 FINISHES - FBC CHAPTER 8
  
 2) DRAWING G-002 SHOWS CORRIDOR WALLS ARE 0 FIRE RATED
 - PLEASE PROVIDE A NOTE AS TO HOW THE ELEVATOR
 HOISTWAYS ARE PROTECTED - FBC 3006.3
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-05-19 Cont ID  
Sent By jleahy Date 2022-05-19 Time 16:17 Rev Time 0.00
Received By jleahy Date 2022-05-19 Time 16:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-05-05 Cont ID  
Sent By pleduc Date 2022-05-05 Time   Rev Time 0.00
Received By pleduc Date 2022-05-05 Time 15:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-06 Cont ID  
Sent By rmcphers Date 2022-06-06 Time 11:14 Rev Time 0.00
Received By rmcphers Date 2022-05-26 Time 08:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-19 Cont ID  
Sent By jleahy Date 2022-05-19 Time 16:17 Rev Time 0.00
Received By jleahy Date 2022-05-04 Time 06:20 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-05-12 Cont ID  
Sent By rmcphers Date 2022-05-12 Time 16:07 Rev Time 0.00
Received By rmcphers Date 2022-05-12 Time 16:07 Sent To  
Notes
2022-05-12 16:07:56NO CHANGE OF OCCUPANCY CLASSIFICATION - NO ADDED SQUARE
 FOOTAGE

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-05-17 Cont ID  
Sent By medwards Date 2022-05-17 Time 14:33 Rev Time 0.00
Received By medwards Date 2022-05-17 Time 14:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-05-31 Cont ID  
Sent By ccole Date 2022-05-31 Time 16:47 Rev Time 0.00
Received By ccole Date 2022-05-31 Time 16:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-05-13 Cont ID  
Sent By ccole Date 2022-05-13 Time 07:23 Rev Time 0.00
Received By ccole Date 2022-05-13 Time 06:49 Sent To  
Notes
2022-05-13 07:24:151ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22050098
 5/13/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-118: SHOW THE CLEAR FLOOR SPACE DIAGRAMS
 WITH DIMENSIONS FOR THE COFFEE SINK, DISHWASHER, AND
 REFRIGERATOR- SECS. 606.2, 804.6.1, 804.6.3, & 804.6.6
 FBC ACC.
  
 2) P-201, P-301, P-401: A MEANS OF LIMITING THE HOT
 WATER DELIVERY TEMPERATURE AT FIXTURES IS REQUIRED AND
 IT CANNOT BE A THERMOSTAT ON A WATER HEATER. A MASTER
 THERMOSTATIC OR POINT OF USE MIXING VALVE SHALL BE
 INSTALLED- SEC. 607.1.1 FBC P. PLEASE DO NOT CONFUSE
 THE CODE REQUIREMENT WITH THE TEMPERED WATER DELIVERY
 REQUIRED FOR PUBLIC LAVATORIES. HOT WATER AT A MINIMUM
 OF 110 DEGREES F IS REQUIRED AT THE SINK AND
 DISHWASHER- SEC. 607.1.
  
 3) P-201, P-301: PROVIDE BACKFLOW PREVENTERS AT THE
 INDIVIDUAL WATER SUPPLY LINES TO THE DISHWASHER AND
 REFRIGERATOR ICE MAKER- SEC. 608.3 FBC P.
  
 4) P-401: THE WATER HEATER DRAIN PAN PIPE SHALL
 TERMINATE OVER A SUITABLY LOCATED INDIRECT WASTE
 RECEPTOR OR FLOOR DRAIN, OR EXTEND TO THE EXTERIOR OF
 THE BUILDING AND TERMINATE ABOVE THE ADJACENT GROUND
 SURFACE- SEC. 504.7.2 FBC P.
  
 5) P-401: PROVIDE UL TESTED AND APPROVED FIRESTOPPING
 ASSEMBLIES FOR PIPES PENETRATING THROUGH THE FLOOR
 SLAB- SECS. 315.1 FBC P AND 714.4.1.2 FBC B.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-05-31 Cont ID  
Sent By ccole Date 2022-05-31 Time 16:48 Rev Time 0.00
Received By ccole Date 2022-05-31 Time 16:48 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-12 Cont ID  
Sent By rmcphers Date 2022-05-12 Time 16:14 Rev Time 0.00
Received By rmcphers Date 2022-05-12 Time 16:14 Sent To  
Notes
***NONE***