Plan Review Details - Permit 22050069
| Plan Review Stops For Permit 22050069 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-11 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-07 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2022-07-11 11:18:19 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | BU1635 BN4338 | | | ASFPM CFM US-21-11935 | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SH WINDOW PRODUCT APPROVAL FL15329-R5 IS FOR | | | NON-IMPACT RATED WINDOWS. OPENING PROTECTION IS | | | REQUIRED. | | | 1609.1.2 PROTECTION OF OPENINGS. | | | IN WIND-BORNE DEBRIS REGIONS, GLAZED OPENINGS IN | | | BUILDINGS SHALL BE IMPACT RESISTANT OR PROTECTED WITH | | | AN IMPACT-RESISTANT COVERING MEETING THE REQUIREMENTS | | | OF ANSI/DASMA 115 (FOR GARAGE DOORS AND ROLLING DOORS) | | | OR TAS 201, 202 AND 203, AAMA 506, ASTM E1996 AND ASTM | | | E1886 REFERENCED HEREIN, OR AN APPROVED | | | IMPACT-RESISTANT STANDARD AS FOLLOWS: | | | GLAZED OPENINGS LOCATED WITHIN 30 FEET (9144 MM) OF | | | GRADE SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE | | | TEST OF ASTM E1996. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-05-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-05-27 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-05-27 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-11 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-03 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-11 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-11 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2022-07-11 11:11:57 | IMPACT FEE QUESTIONNAIRE | | | | | | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-05-11 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-05-11 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-05-11 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2022-05-11 15:17:25 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. V7 FRC P2705.1 - WITH A DIMENSION OF 4'2" IN THE | | | BATHROOM, DEPENDING ON WHAT TYPE OF WATER CLOSET YOU | | | INTEND TO INSTALL, YOU MAY OR MAY NOT HAVE 21" OF | | | REQUIRED CLEARANCE TO THE FRONT. PLEASE SHOW THE | | | INTENDED WATER CLOSET WITH DIMENSIONS. | | | | | | 2. V7 FRC P2708.1.1 - ACCESS TO THE SHOWER IS REQUIRED | | | TO BE A CLEAR AND UNOBSTRUCTED 22" WIDE. WITH THE | | | DIMENSION OF 4'2" AND THE WATER CLOSET IN FRONT COULD | | | IMPEDE ON THE REQUIRED 22" UNOBSTRUCTED OPENING. | | | | | | 3. 2017 WPB AMEND 109.3 BUILDING PERMIT VALUATIONS - | | | THE VALUE STATED ON THE PERMIT AT $2400 IS LOW. PLEASE | | | PROVIDE DOCUMENTATION SHOWING A MORE ACCURATE VALUE. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-07-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-11 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-07 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2022-07-11 11:12:33 | OWNER/BUILDER SIGNED ALL PLAN SHEETS. CT |
|
|
|
Account Summary | Usage Policy | Privacy Policy