Plan Review Details - Permit 22050069
Plan Review Stops For Permit 22050069
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-07-11 Cont ID  
Sent By cthroop Date 2022-07-11 Time 11:12 Rev Time 0.00
Received By cthroop Date 2022-07-07 Time 13:30 Sent To  
Notes
2022-07-11 11:18:19PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SH WINDOW PRODUCT APPROVAL FL15329-R5 IS FOR
 NON-IMPACT RATED WINDOWS. OPENING PROTECTION IS
 REQUIRED.
 1609.1.2 PROTECTION OF OPENINGS.
 IN WIND-BORNE DEBRIS REGIONS, GLAZED OPENINGS IN
 BUILDINGS SHALL BE IMPACT RESISTANT OR PROTECTED WITH
 AN IMPACT-RESISTANT COVERING MEETING THE REQUIREMENTS
 OF ANSI/DASMA 115 (FOR GARAGE DOORS AND ROLLING DOORS)
 OR TAS 201, 202 AND 203, AAMA 506, ASTM E1996 AND ASTM
 E1886 REFERENCED HEREIN, OR AN APPROVED
 IMPACT-RESISTANT STANDARD AS FOLLOWS:
 GLAZED OPENINGS LOCATED WITHIN 30 FEET (9144 MM) OF
 GRADE SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE
 TEST OF ASTM E1996.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-05-27 Cont ID  
Sent By jleahy Date 2022-05-27 Time 09:54 Rev Time 0.00
Received By jleahy Date 2022-05-27 Time 09:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-11 Cont ID  
Sent By cthroop Date 2022-07-11 Time 11:18 Rev Time 0.00
Received By cthroop Date 2022-05-03 Time 16:34 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-07-11 Cont ID  
Sent By cthroop Date 2022-07-11 Time 11:11 Rev Time 0.00
Received By cthroop Date 2022-07-11 Time 11:09 Sent To  
Notes
2022-07-11 11:11:57IMPACT FEE QUESTIONNAIRE
  
 PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT
 LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO
 THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF.
 THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ
 B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE
 RECEIPT TO PROJECT DOX OR EMAIL IT TO
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-05-11 Cont ID  
Sent By rwbrown Date 2022-05-11 Time 15:02 Rev Time 0.00
Received By rwbrown Date 2022-05-11 Time 14:28 Sent To  
Notes
2022-05-11 15:17:251ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. V7 FRC P2705.1 - WITH A DIMENSION OF 4'2" IN THE
 BATHROOM, DEPENDING ON WHAT TYPE OF WATER CLOSET YOU
 INTEND TO INSTALL, YOU MAY OR MAY NOT HAVE 21" OF
 REQUIRED CLEARANCE TO THE FRONT. PLEASE SHOW THE
 INTENDED WATER CLOSET WITH DIMENSIONS.
  
 2. V7 FRC P2708.1.1 - ACCESS TO THE SHOWER IS REQUIRED
 TO BE A CLEAR AND UNOBSTRUCTED 22" WIDE. WITH THE
 DIMENSION OF 4'2" AND THE WATER CLOSET IN FRONT COULD
 IMPEDE ON THE REQUIRED 22" UNOBSTRUCTED OPENING.
  
 3. 2017 WPB AMEND 109.3 BUILDING PERMIT VALUATIONS -
 THE VALUE STATED ON THE PERMIT AT $2400 IS LOW. PLEASE
 PROVIDE DOCUMENTATION SHOWING A MORE ACCURATE VALUE.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-07-11 Cont ID  
Sent By cthroop Date 2022-07-11 Time 11:12 Rev Time 0.00
Received By cthroop Date 2022-07-07 Time 13:30 Sent To  
Notes
2022-07-11 11:12:33OWNER/BUILDER SIGNED ALL PLAN SHEETS. CT


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved