Plan Review Details - Permit 22050008
Plan Review Stops For Permit 22050008
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-06-24 Cont ID  
Sent By rmcdouga Date 2022-06-24 Time 09:58 Rev Time 0.00
Received By rmcdouga Date 2022-06-24 Time 09:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-05-24 Cont ID  
Sent By mpeterso Date 2022-05-24 Time 12:35 Rev Time 0.00
Received By mpeterso Date 2022-05-24 Time 12:35 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2022-07-19 Cont ID  
Sent By ccole Date 2022-07-19 Time 09:47 Rev Time 0.00
Received By ccole Date 2022-07-19 Time 09:47 Sent To  
Notes
2022-07-19 09:48:15GAS APPROVED UNDER PERMIT- 22070677.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-05-05 Cont ID  
Sent By ccole Date 2022-05-05 Time 17:09 Rev Time 0.00
Received By ccole Date 2022-05-05 Time 15:55 Sent To  
Notes
2022-05-05 17:09:51 
 1ST REVIEW FBC-2020 RES. GAS
 PERMIT- 22050008
 5/5/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 2: PROVIDE A GAS RISER DRAWING THAT INCLUDES
 THE NEW GAS PIPING TO THE GRILL AND THE FOLLOWING
 INFORMATION:
 A) DELIVERY PRESSURE OF THE SYSTEM.
 B) TYPES AND SIZE OF EXISTING PIPING.
 C) LOCATIONS OF SHUTOFF VALVES AND REGULATORS.
 D) INLET AND OUTLET PRESSURES AT REGULATORS.
 E) LOCATIONS AND TYPES OF PIPE SLEEVES.
 F) PIPE SIZING TABLES.
  
 2) SHEET 2: THE SUBMITTED GRILL SPECIFICATIONS ARE
 INCOMPLETE. PLEASE SUBMIT SPECS AND INSTALLATION MANUAL
 THAT SHOW THE BTU LOAD, GAS INPUT PRESSURE, CLEARANCES
 TO COMBUSTIBLE AND OVERHEAD CONSTRUCTION, COMBUSTION
 AIR AND VENTILATION, AND EXHAUST VENTING GUIDELINES.
 PLEASE NOTE THAT AN EXHAUST HOOD AND DUCT SYSTEM MAY BE
 REQUIRED- SEC. G2448.1 FBC RES. PROVIDE PLAN DETAILS
 THAT REFLECT THE INSTALL MANUAL RECOMMENDATIONS AND
 RESTRICTIONS.
  
 3) SHEET 2: SHOW THE CLEARANCE DISTANCES FROM THE GRILL
 EXHAUST TO GRAVITY AND MECHANICAL AIR INTAKES INTO THE
 BUILDING- SEC. R303.5.1 FBC RES. MINIMUM 10 FT.
 CLEARANCES REQUIRED.
  
 4) PROVIDE A PLUMBING SUB-PERMIT APPLICATION- SEC.105.1
 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-07-19 Cont ID  
Sent By ccole Date 2022-07-19 Time 09:46 Rev Time 0.00
Received By ccole Date 2022-07-19 Time 09:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-06-24 Cont ID  
Sent By rmcdouga Date 2022-06-24 Time 09:58 Rev Time 0.00
Received By rmcdouga Date 2022-05-04 Time 08:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2022-07-19 Cont ID  
Sent By ccole Date 2022-07-19 Time 09:46 Rev Time 0.00
Received By ccole Date 2022-07-19 Time 09:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-05-05 Cont ID  
Sent By ccole Date 2022-05-05 Time 17:13 Rev Time 0.00
Received By ccole Date 2022-05-05 Time 15:55 Sent To  
Notes
2022-05-05 17:17:121ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22050008
 5/5/22
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 1: IDENTIFY THE LOCATIONS OF ANY FIXTURES
 REQUIRING WATER SUPPLY OR DRAINAGE DISPOSAL AND PROVIDE
 DETAILS INCLUDING RISER DRAWINGS- SECS. 107.2.1 AND
 107.3.5.3 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-05 Cont ID  
Sent By mpeterso Date 2022-05-05 Time 10:30 Rev Time 0.00
Received By mpeterso Date 2022-05-05 Time 10:30 Sent To  
Notes
2022-05-05 10:36:085/5/22 SIGNATURE REVIEW OF PAPER PLANS AND DOCUMENTS
 PASSED. MP

Review Stop Z ZONING
Rev No 1 Status P Date 2022-05-12 Cont ID  
Sent By asangele Date 2022-05-12 Time 09:39 Rev Time 0.00
Received By asangele Date 2022-05-12 Time 09:39 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy