Plan Review Details - Permit 22041513
Plan Review Stops For Permit 22041513
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2022-07-05 Cont ID  
Sent By jwitmer Date 2022-07-05 Time 15:28 Rev Time 0.00
Received By jwitmer Date 2022-07-05 Time 15:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-07-19 Cont ID  
Sent By jwitmer Date 2022-07-19 Time 17:07 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-07-05 Cont ID  
Sent By jwitmer Date 2022-07-05 Time 15:49 Rev Time 0.00
Received By jwitmer Date 2022-07-05 Time 15:27 Sent To  
Notes
2022-07-05 15:49:40WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22041513
 ADD: 2000 PRESIDENTIAL WAY # 406
 CONT: O & D TOTAL HOME REPAIR
 TEL: 561-969-3121
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JULY 05TH/2022
 ACTION: DENIED
  
 1) THE CONTRACTOR HAS SUBMITTED A UNDERLAYMENT BROCHURE
 FOR PROFLEX MSC. PLEASE NOTE THE PROFLEX MSC HAS ONLY
 BEEN TESTED ON 8-INCH CONCRETE SLABS WITH DROPPED
 CEILINGS FOR PORCELAIN TILE, SEE PAGE 2.
 FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE,
 STONE, MARBLE, VINYL (LYT/ LYP), LAMINATE FLOORING AND
 WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND
 UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING
 STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH
 OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/
 NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR
 TYPE II BUILDINGS SHOWING COMPLIANCE WITH:
  
 1A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 1B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 1C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2. (TILE
 & MARBLE) INSULATION INSTALLED BETWEEN A FINISHED FLOOR
 AND SOLID DECKING WITHOUT INTERVENING AIRSPACE SHALL BE
 ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN
 200.
  
 2) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-07-25 Cont ID  
Sent By mpeterso Date 2022-07-25 Time 15:26 Rev Time 0.00
Received By mpeterso Date 2022-07-25 Time 15:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-06-08 Cont ID  
Sent By mpeterso Date 2022-06-08 Time 13:07 Rev Time 0.00
Received By mpeterso Date 2022-06-08 Time 13:07 Sent To  
Notes
2022-06-08 13:11:52ELECTRIC REVIEW FAILED
 1) ELECTRIC PANEL LOCATION APPEARS THAT IS DOES NOT
 COMPLY WITH NEC 110.26 FOR WORKING SPACE CLEARANCES.
 PLEASE DETAIL THE CLEARANCES TO SHOW COMPLIANCE.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-05-03 Cont ID  
Sent By cwalker Date 2022-05-03 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-05-03 13:41:39FIRE PROVISO COMMENTS:
 (1) ENSURE SMOKE ALARM INSTALLATION IN THE MAIN BEDROOM
 (2) ANY MODIFICATION TO THE FIRE SPRINKLER SYSTEM SHALL
 BE PERFORMED UNDER SEPARATE PERMIT AND SHOP DRAWINGS
 AND THE WORK IS BE PERFORMED ONLY BY PROPERLY LICENSED
 CONTRACTORS FOR THIS WORK.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-08-01 Cont ID  
Sent By rwbrown Date 2022-08-01 Time 06:20 Rev Time 0.00
Received By rwbrown Date 2022-07-29 Time 15:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-07-25 Cont ID  
Sent By mpeterso Date 2022-07-25 Time 15:26 Rev Time 0.00
Received By mpeterso Date 2022-07-13 Time 08:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-05 Cont ID  
Sent By jwitmer Date 2022-07-05 Time 15:50 Rev Time 0.00
Received By jwitmer Date 2022-05-02 Time 11:25 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-07-05 Cont ID  
Sent By jwitmer Date 2022-07-05 Time 15:28 Rev Time 0.00
Received By jwitmer Date 2022-07-05 Time 15:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-05-27 Cont ID  
Sent By medwards Date 2022-05-27 Time 06:23 Rev Time 0.00
Received By medwards Date 2022-05-27 Time 06:23 Sent To  
Notes
2022-05-27 06:24:46APPROVED WITH PRIVISO:
 EXISTING DRYER DUCT MUST BE CAPPED AND THE
 SPECIFICATIONS FOR THE VENTLESS DRYER MUST BE ONSITE AT
 TIME OF INSPECTION. ME

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-08-01 Cont ID  
Sent By rwbrown Date 2022-08-01 Time 06:19 Rev Time 0.00
Received By rwbrown Date 2022-08-01 Time 06:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-07-15 Cont ID  
Sent By rwbrown Date 2022-07-15 Time 13:13 Rev Time 0.00
Received By rwbrown Date 2022-07-15 Time 13:13 Sent To  
Notes
2022-07-15 13:13:332ND PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. NOT CORRECTED - 2020 FPC 918.3.1 - THE STUDOR VENT
 CANNOT BE USED BECAUSE IT IS MORE THAN 4 BRANCH
 INTERVALS FROM THE TOP FLOOR, UNLESS THERE IS A RELIEF
 VENT THAT CONNECTS BACK TO A STACK VENT OR VENT STACK
 OR GOES TO THE OUTDOORS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-05-25 Cont ID  
Sent By rwbrown Date 2022-05-25 Time 14:08 Rev Time 0.00
Received By rwbrown Date 2022-05-25 Time 13:58 Sent To  
Notes
2022-05-25 14:08:031ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FPC 918.3.1 - THE STUDOR VENT CANNOT BE USED
 BECAUSE IT IS MORE THAN 4 BRANCH INTERVALS FROM THE TOP
 FLOOR, UNLESS THERE IS A RELIEF VENT THAT CONNECTS BACK
 TO A STACK VENT OR VENT STACK OR GOES TO THE OUTDOORS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-07-29 Cont ID  
Sent By jgomez Date 2022-07-29 Time 17:26 Rev Time 0.00
Received By jgomez Date 2022-07-29 Time 17:17 Sent To  
Notes
2022-07-29 17:27:30HARD COPY DWGS 5 OF 8 AND 6 OF 8 WITH EMBOSSED SEAL AND
 WET SIGNATURE. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-07-14 Cont ID  
Sent By mpeterso Date 2022-07-14 Time 13:56 Rev Time 0.00
Received By mpeterso Date 2022-07-14 Time 13:56 Sent To  
Notes
2022-07-14 13:56:277/14/22 SIGNATURE REVIEW OF PAPER PLANS/DOCUMENTS
 PASSED AND ROUTED TO STORAGE.MP

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-02 Cont ID  
Sent By mpeterso Date 2022-05-02 Time 14:52 Rev Time 0.00
Received By mpeterso Date 2022-05-02 Time 14:52 Sent To  
Notes
2022-05-02 14:53:195/2/22 SIGNATURE REVIEW OF PAPER PLANS PASSED AND
 ROUTED TO STORAGE. M.P.